01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 December 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel was due for drydock examination on November 20th, 2025 and has yet to receive a drydock exam. Vessel shall not operate with passengers until a drydock inspection has been completed.
46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2025
Resolved 15 December 2025
Resolution: Completed Credit Drydock and Internal Structural Examination.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 March 2025
Resolved
MI observed vessel with 7 total Flares. Vessel required to have 12 Total Flares onboard (6 Day/6 Night), vessel only had 4 Night Flares and 3 Smoke Flares. Vessel Rep purchased 6 additional Night/Day Flares to be in compliance. Corrected on the spot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2025
Resolved 3 April 2025
Resolution: Corrected on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 November 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel was due for drydock examination on 31OCT23 and has yet to receive a drydock exam.
46CFR176.600(c)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2023
Resolved 28 November 2023
Resolution: Credit DD/ISE completed.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 23 February 2023
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry -Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. A hand red flare distress signal may be substituted for any of the hand orange smoke distress signals required under paragraph (a) or (b) of this section.
Four red hand flares were found expired. The vessel has eight red hand flares onboard for distress signals.
46 CFR 180.68
Action required: 705 - Other - as specified
Due 23 February 2023
Resolved 23 February 2023
Resolution: The operator purchased four new red hand flares. The vessel now has 12 red hand flares onboard.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 February 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed.
The hydrostatic release was found expired.
46 CFR 185.740
Action required: 705 - Other - as specified
Due 23 February 2023
Resolved 23 February 2023
Resolution: The operator purchased and installed a new hydrostatic release for the EPIRB.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 February 2023
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section.
The COI requires the vessel to carry one 2-A portable fire extinguisher. One 1-A portable fire extinguisher was found onboard.
46 CFR 181.500
Action required: 705 - Other - as specified
Due 23 February 2023
Resolved 23 February 2023
Resolution: The operator purchased a new 2-A portable fire extinguisher and placed it into service onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 February 2023
Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation.
Two 8 AWG conductors were found in the engine room, used as a jumper from terminal strip to stud, without overcurrent protection. The conductor must be protected IAW its current carrying capacity.
46 CFR 183.380(l)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2023
Resolved 7 March 2023
Resolution: The operator installed a UL listed cartridge fuse on the 8 AWG conductor below the current carrying capacity of the conductor.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 February 2022
Resolved
A Certificate of Inspection is valid for 5 years. During administrative inspection, MI found vessel's COI to be expired. Vessel shall not carry passengers until MI issues renewal COI.
46CFR176.107(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2022
Resolved 9 February 2022
Resolution: Renewal COI was issued after a complete inspection was conducted. New COI issued this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2022
Resolved
A vessel must be provided with a main steering gear that is: Of adequate strength and capable of steering the vessel at all service speeds; Designed to operate at maximum astern speed without being damaged or jammed; and Capable of moving the rudder from 35 degrees on one side to 30 degrees on the other side in not more than 28 seconds with the vessel moving ahead at maximum service speed. The vessel lost steering and movement of the rudder while conducting a man overboard recovery drill underway during a COI inspection. A technician is scheduled to attend on February 11, 2022. 46 CFR § 182.610
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2022
Resolved 18 February 2022
Resolution: Inspected steering wheel helm hydraulic unit and associated gear. Third party technician replaced all internal seals and one hose. Conduted operational test at dock and underway of the system - all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 February 2022
Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Operator failed to test the EPIRB monthly in Nov and Dec 2021 and Jan 2022. EPIRB tested on the inspection this date and logged. 46 CFR § 185.728
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 9 February 2022
Resolution: EPIRB tested on the inspection this date and logged.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 9 February 2022
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The crew failed to conduct a drill every three months. The last recorded dril was on October 4, 2021. 46 CFR § 185.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2022
Resolved 18 February 2022
Resolution: Master and crew conducted underway drills to include manoverboard, fire drill in port engine compartment and abandonship, all drills sat. Told crew to document drills conducted this day in log.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 February 2022
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The FCC Safety Certificate is expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2022
Resolved 18 February 2022
Resolution: A new FCC Communications Act Safety Radiotelephony Certificate was issued February 15, 2022 with an expiration of February 15, 2027 - all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 February 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The first aid kit onboard did not have all provisions from 160.041 and several items were expired. 46 CFR § 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2022
Resolved 3 March 2022
Resolution: A new first aid kit that complies with regulations is onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2022
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. The conductors from the battery switch to the DC panel have blade automotive fuses installed instead of UL listed cartridge type fuses. 46 CFR § 183.380(L)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2022
Resolved 18 February 2022
Resolution: Cartridge type fuses and holder were replaced at the DC panel that previously had blade fuses installed - all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 February 2022
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. An aux sail preventative maintenance plan shall be in place and completed by the crew. The PMP shall be logged by the crew upon completion. The crew established a PMP after the previous USCG Annual inspection but crew members failed to log the PMP maintenance conducted over the past year. 46 CFR § 176.840
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2022
Resolved 3 March 2022
Resolution: The operator provided proof of logging the PMP for the sail rigging for February and March 2022.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 February 2021
Resolved
The preventative maintenance plan (PMP) should address the following at a minimum: the maintenance schedule of the rigging and associated equipment to include detailed protocol for examinations and inventory of rigging components including age of component as well as size and replacement schedule. The vessel's PMP does not contain the age of components or replacement schedules. The vessel's PMP is missing detailed protocol for examinations to be conducted by the crew. Identified the following during a visual inspection of the deck level standing rigging: 1/2" fracture in the starboard shroud chainplate. The third party rigging inspection completed on Feb. 22, 2021 shall establish a baseline to create the vessel's PMP. Provide a PMP for this vessel. The PMP shall include at a minimum: the maintenance schedule of the rigging and associated equipment to include detailed protocol for examinations, inventory of rigging components including age of component as well as size, and replacement schedule (life cycle). A third party rigging survey does not substitute for the vessel owner/operator from implementing a PMP or conducting/documenting preventative maintenance. 46 CFR 176.840
Action required: 705 - Other - as specified
Due 22 April 2021
Resolved 14 May 2021
Resolution: The operator created a preventative maintenance plan that includes: the standing rigging components, the age of the standing rigging components, the maintenance of the standing rigging components, the replacement cycle of the standing rigging components.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2021
Resolved
Rigging component was found with evidence of a fracture. Starboard shroud chainplate found with 1/2" long fracture. The fracture was found 2" above the bottom of the chainplate and traveled in a horizontal direction. Due to the location of the fracture being found at the bottom of the chainplate, scantling of the chainplate (3/4"), the continued monitoring of the fracture by the master/owner, and recommendations from the attending third party surveyor, the chainplate may remain in service until the next scheduled dry dock where it shall be replaced. Evidence of the fracture continuing to grow or creating new fractures above this area will require the chainplate to be replaced immediately. It is the owner/master's responsibility to monitor this area for further damage. 46 CFR 176.600
Action required: 705 - Other - as specified
Due 31 October 2021
Resolved 28 October 2021
Resolution: The chain plate was cleaned by the crew members and a dye penetrant non destructive test was observed by the MI. The chain plate was found with no evidence of a fracture and placed back into service.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 22 February 2021
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. VHF radio will not broadcast GPS position due to a faulty GPS. Renew GPS installation and connect to the VHF for DSC broadcast. Contact inspector for re-inspection when installed. Vessel is restricted to routes no further than 1000 feet from shore until rectified.
46CFR184.52
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2021
Resolved 23 February 2021
Resolution: The operator purchased a new GPS unit and connected it to the existing VHF radio. The VHF was tested and has the capability to broadcast position under DSC feature.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2021
Resolved
The mast is structurally supported by a transverse crossbeam made of FRP visible on the main deck which is fastened to each hull using a chain plate. Visually inspected the chainplates for the mast crossbeam and identified pitting corrosion under the bolts/washers used for fastening. The mast crossbeam chainplates were 3/4" thick and appeared servicable until the next dry dock in the corroded condition. The pitting corrosion depth measured up to 3/8" in some areas but the pitting diameter was less than 1/8" in these heavily pitted areas. The owner shall replace the chainplates or submit a proposal to repair and leave the chainplates in service.
46 CFR 176.600
Action required: 705 - Other - as specified
Due 31 October 2021
Resolved 28 October 2021
Resolution: The chain plate was cleaned by the crew. The crew used an epoxy resing to fill the pitting corrosion. The fasteners were isolated from the chain plate using a plastic washer to prevent further corrosion. The area will be monitored under the PMP.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2021
Resolved
Structural support for starboard side trampoline net was found fractured at the bolt fastener connection. Structural support is bowed out in several areas due to weight on the trampoline net and the fractured support. Passengers are not permitted to use the starboard trampoline netting. Make satisfactory repairs to the trampoline net structural support. 46 CFR 176.600
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 14 May 2021
Resolution: The operator replaced the structural support for the trampline net. The area was inspected by the MI and found to be satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 January 2020
Resolved
Each ring life buoy on a vessel must: be approved in accordance with 160.050 in subchapter Q of this chapter. The ring life buoy's grab line was deteriorated and no longer serviceable. Replace.
46 CFR 180.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2020
Resolved 14 February 2020
Resolution: Operator purchased, marked, and installed new ring life buoy.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 January 2020
Resolved
Provide proof that operator has implemented a preventative maintenance plan IAW NVIC 02-16.
46 CFR 176.802
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2020
Resolved 16 August 2020
Resolution: Vessel failed to implement preventative maintenance plan IAW NVIC 02-16, recommend annual third party surveys on standing and running rigging.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 7 March 2019
Resolved
VHF radio missing GPS input and FCC license expired. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 22 March 2019
Resolution: Operator provided GPS to radio.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2019
Resolved
Missing previous year's MIS report. 46 CFR 16.500(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 22 March 2019
Resolution: Operator has current report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 March 2019
Resolved
Bilge high level alarm visual alarm inoperable. 46 CFR 182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 8 March 2019
Resolution: Completed satisfactory test of bilge high level visual alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 March 2019
Resolved
Child sized life jackets not separated from adult life jackets. 46 CFR 180.78
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 8 March 2019
Resolution: Child sized life jackets stowed separate from adult life jackets.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 7 March 2019
Resolved
Owner could not provide drill log for man overboard and fire fighting. 46 CFR 185.410
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 8 March 2019
Resolution: Owner provided drill log.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 March 2019
Resolved
Owner could not provide monthly EPIRB testing log. 46 CFR 185.728
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 22 March 2019
Resolution: Operator provided testing log.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 March 2019
Resolved
Portable fire extinguishers were not permanently mounted. 46 CFR 181.500(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 22 March 2019
Resolution: Operator mounted fire extinguishers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 March 2019
Resolved
Portable fire extinguisher under bar area not clearly visible. 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 22 March 2019
Resolution: Operator posted label.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 March 2019
Resolved
Port side engine space pre-engineered fixed gas fire extinguishing system did not automatically shut down the engine. 46 CFR 181.420(a)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2019
Resolution: Completed satisfactory test of port side engine space pre-engineered fixed gas fire extinguishing system.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 7 March 2019
Resolved
Both pre-engineered fixed gas fire extinguishing systems must be installed to manufacturer's instructions and operate independently of one another. 46 CFR 181.420(a)(3)/(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 22 March 2019
Resolution: Operator installed new Fireboy control for port side.
Communications › Radio Communications › EPIRB
Issued 31 January 2018
Resolved
Replace expired EPIRB battery. 46CFR180.64
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 1 February 2018
Resolution: Operator purchased new EPIRB.
Communications › Radio Communications › EPIRB
Issued 31 January 2018
Resolved
Provide valid NOAA decal on EPIRB. 46CFR180.64
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 13 March 2018
Resolution: Placed registration decal on EPIRB
Communications › Radio Communications › VHF Radiotelephone
Issued 31 January 2018
Resolved
Provide GPS input to VHF-FM radio. 46CFR184.502
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 30 April 2018
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 January 2018
Resolved
Replace life line for ring buoy with 5/16 inch buoyant line 60 feet in length. 46CFR180.70(c)
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 2 February 2018
Resolution: Operator replaced life line meeting regulation.
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 31 January 2018
Resolved
Replace missing cotter pins on turnbuckles; lower spreader bar. 46CFR176.802(a)(3)
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 2 February 2018
Resolution: Operator replaced missing cotter pins.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 31 January 2018
Resolved
Provide proof that operator has implemented a preventative maintenance plan IAW NVIC 02-16. 46CFR176.802(a)(3)
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 16 August 2020
Resolution: Vessel Operator has not implemented Preventative maintenance plan IAW NVIC 02-16. Recommend third party survey on standing and running rigging at each annual inspection and COI to ensure safety of components.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 31 January 2018
Resolved
Provide company drug testing policy and proof employees have read and signed policy. 46CFR16.113
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 13 March 2018
Resolution: Received record of training.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 31 January 2018
Resolved
Provide proof of supervisor and employee EAP training. 46CFR16.401
Action required: 705 - Other - as specified
Due 14 February 2018
Resolved 13 March 2018
Resolution: Received proof of training.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 20 October 2017
Resolved
Provide correct size (> 127 cu ft), fire extinguishing system. Vessel currently has the wrong size bottle for the engine space. 46CFR181.400(1)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 14 December 2017
Resolution: Deficiency tested and cleared, starboard side fixed fire sys in the engine room updated to new T 14-dec-17.
Sail Rigging › Catamaran › Dolphin/Pelican Striker and Bridle Arrangement
Issued 4 October 2017
Resolved
Replace metal for Dolphin striker on frwd longitudinal mount. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 5 October 2017
Resolution: Replaced metal for Dolphin striker on frwd longitudinal mount to the satisfaction of the Marine Inspector.
Construction/Loadline › Penetrations › Valve Flange
Issued 4 October 2017
Resolved
Repair port side valve in head space. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 12 October 2017
Resolution: Replaced valve.
Sail Rigging › Catamaran › Dolphin/Pelican Striker and Bridle Arrangement
Issued 4 October 2017
Resolved
Repair crack in head stay bridle on strbd side. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 12 October 2017
Resolution: Replaced turnbuckle in kind.
Sail Rigging › Running Rigging › Halyards
Issued 4 October 2017
Resolved
Repair crack in jib halyard sheave. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 12 October 2017
Resolution: Special note added. This deficiency will be corrected in the future. Alternate jib halyard sheave is currently being used.
Sail Rigging › Stays/Shrouds › Terminals/End Fittings
Issued 4 October 2017
Resolved
Repair cracked weld in main port shroud. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 12 October 2017
Resolution: Repaired crack in port shroud via welding.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 January 2017
Resolved
COI expired 09DEC2016. Complete COI inspection per 46CFR176.105
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2017
Resolution: Attending marine inspectors conducted initial COI inspection and endorsed COI.
Sail Rigging › Winches › Mast Mounted
Issued 31 March 2016
Resolved
Prepare mast for visual inspection of mast bracket to boom and repair proposal.
Due 15 April 2016
Resolved 6 April 2016
Resolution: Elongated hole of bottom gooseneck bracket drilled out and replaced with aluminum bushing with SS washers on both sides.