Records from 1992 to 2017. Most recent: inspection, 6 February 2017.
Inspection history · 43
6 February 2017
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6082726
29 November 2016
COC-CVE Annual · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6048609
22 February 2016
COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5818861
19 January 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5799141
14 December 2015
PII Safety Exam · Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5780637
14 December 2010
Deficiency Check · COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3910249
15 November 2010
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3891394
29 March 2010
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3704626
22 December 2009
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3653875
15 December 2008
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3379842
2 February 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3140605
21 January 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3132628
10 December 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3112854
8 December 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3111759
16 November 2007
PII Safety Exam · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3099489
21 March 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2892244
12 December 2005
MARPOL Annex V Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2549746
30 December 2004
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2264700
26 November 2004
Ballast Water Examination · MARPOL Annex I Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2248288
23 February 2004
Administrative Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2011551
1 December 2003
Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1957443
25 November 2002
Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1683257
28 January 2002
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1481708
27 November 2001
Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1366677
7 March 2000
MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1365632
14 December 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 435870
9 December 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 812310
24 November 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 810293
31 March 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 488608
13 January 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 424505
16 December 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 423705
16 December 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 423877
20 October 1995
Administrative
Administrative · Marine Safety Center (MSC) · Activity 883498
1 September 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 370456
1 September 1994
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 864385
15 September 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 360889
16 June 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 358950
16 June 1993
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 842291
19 April 1993
Administrative
Administrative · Commandant (CG-CVC) · Activity 1149671
15 February 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 690101
17 December 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 831722
28 November 1992
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1141821
27 November 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 354788
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 November 2016
No resolution recorded
Fire Control Plan has not been kept up to date. Two new crew cabins have been added in a space that used to be a sauna /spa area, SFP was on final review stage for Flag approval. Vessel representative was waiting for final flag approval to sent the SFP to MSC for review.
Action required: 705 - Other - as specified
Due 6 May 2017 — due date passed with no resolution recorded
Fire Fighting › Structural - A Class Divisions › Doors
Issued 29 November 2016
Resolved
PSCO found fire door not closing and blocked by the floor carpet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 29 November 2016
Resolution: Carper was removed and witnessed the correct operation of fire door. Corrected on the Spot.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 14 December 2015
Resolved
Doors and door frames in B class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that division. PSCO found a B-15 fire screen door adjacent to garbage room on portside damaged and not closing properly. 74 SOLAS 97 II-2/31.1.1.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 19 January 2016
Resolution: Crew adjusted and repaired door, as well as the doorstep, which properly renewed the necessary fire resistance of the door.
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 December 2015
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger. PSCO found excessive wastage on drainage elbow attached to the overboard discharge valve in the A/C room. 74 SOLAS 97 I/11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 19 January 2016
Resolution: Vessel's crew replaced noted piping with a new section of piping.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 14 December 2015
Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks, the minimum fire integrity of all bulkheads and decks shall be as prescribed in table 26.2. PSCO found section valve 8 space on deck D, and portside bunkering station to be missing of required fire protection insulation. 74 SOLAS 97 II-2/26.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 19 January 2016
Resolution: Vesse's crew replaced both sections of noted insulation that was missing.
Lifesaving › Lifeboat › Markings
Issued 15 November 2010
Resolved
Found NON-SOLAS approved retro-reflective tape on the underside of lifeboats 1-6 and also found unserviceable retro-reflective tape on topside of lifeboats.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 December 2010
Resolution: At the date of the survey it has been confrimed that all retro-reflective tapes have been satisfactorily replaced by SOLAS approved tapes on tops and on sides of the 10 lifeboats/tenders of the ship.
Stability › Weathertight Integrity › General
Issued 15 November 2010
Resolved
Knife edge on the weather tight door leading to the STBD mooring station is wasted and holed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 December 2010
Resolution: The knife edge of the watertight fdoor leading to the starboard aft morring station Fr 16 has been satisfactory repaired.
Fire Fighting › Means of Escape › Corridors
Issued 15 November 2010
No resolution recorded
Found plywood and plastic sheets and general items stored in passage way leading to paint locker deck D.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolution: At the date of the survey, the passageway leading to the paint locker was observed free of material, or equipment that can block a free escape.
Fire Fighting › Means of Escape › Stairways
Issued 15 November 2010
Resolved
Found chairs stored under stairway . Deficiency corrected on spot.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 November 2010
Resolution: Corrected on the spot.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 15 November 2010
Resolved
Found unsecured oxygen and acetylene bottles held in place by rope. Deficiency rectified on the spot.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 November 2010
Resolution: Deficiency rectified on the spot.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 15 November 2010
Resolved
Structural fire protection missing above door leading out of the STBD bunker station, deck C.
Action required: 705 - Other - as specified
Resolved 15 December 2010
Resolution: The structural fire protection has been satisfactorily restored as per the approved structial fire protection drawing above the door frame 192 leading to the starboard side bunker station.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 15 November 2010
Resolved
The Notice of Arrival was incomplete in that it was missing two of the five ports required by 33 CFR 160.206.
Due 15 November 2010
Resolved 15 November 2010
Resolution: While onboard vessel for COC-CVE exam discussed importance with Master [name withheld] and [name withheld] the importance of submitting the last five ports of call on the Notice of Arrival.
Engineering › Steering Gear System › Piping
Issued 22 December 2009
Resolved
Hydraulic fluid is not being cleaned and presents a safety hazard. 74 SOLAS (97 CONSED) Ch II-1 Part C Reg. 29.12.1
Action required: 15 - Rectify deficiencies by next port
Resolved 29 March 2010
Resolution: steering gear does appear to be maintained and no major leaks are present.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 22 December 2009
Resolved
Door #1 on deck going into battery room is corroding at the bottom of the door compromising weathertight integrity. ICLL 66 Annex I Ch II Reg 12 (1)
Action required: 15 - Rectify deficiencies by next port
Resolved 29 March 2010
Resolution: bottom side of the door was cut and renewed.
Accommodation/Occupational Safety › Ventilation › General
Issued 22 December 2009
Resolved
Exhaust fan for engine room exhaust trunk presents a hazard due to a protective cover not installed and moving parts present. 74 SOLAS (97 CONSED) CH II-1 Part c Reg 26.1
Action required: 15 - Rectify deficiencies by next port
Resolved 29 March 2010
Resolution: Fan belt cover was replaced.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 16 November 2007
Resolved
ENSURE ALL WASTE RECEPTICALS ARE MADE OF NON-COMBUSTIBLE MATERIALS THROUGH THROUGHOUT THE VESSEL.
Action required: 705 - Other - as specified
Due 16 December 2007
Resolved 15 December 2008
Resolution: Conducted CVE Annual in Saint John, U.S.V.I. and verified non-combustible materials are being used throughout the vessel.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 November 2004
Resolved
Vessel's OWS is in disrepair. Vessel to retain onboard all oily waste & dispose of ashore. Flag/Class to board vessel & provide a report on OWS condition prior to December 29, 2004.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 30 December 2004
Resolution: Witnessed a sat operational test of OWS
Personnel › Training › Crowd Management
Issued 26 November 2004
Resolved
Vessel to provide alternate crew muster leaders for muster stations #7 & #8.
Due 29 December 2004
Resolved 30 December 2004
Resolution: Captain provided list with alternate crew muster leaders.
Lifesaving › Launching Appliances › Davit
Issued 26 November 2004
Resolved
Vessel to prove proper operation of davit launched liferaft to attending Coast Guard marine Inspector prior to December 29, 2004.
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 30 December 2004
Resolution: Witnessed a sat liferaft deployment drill
Operations/Management › Lifesaving
Issued 1 December 2003
Resolved
Vessel to provide proof of submital of SAR Plan of Cooperation IAW Solas 74 as amended V/7.3. LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Due 31 December 2003
Resolved 23 February 2004
Documentation › Logs/Records
Issued 1 December 2003
Resolved
Vessel to properly fill out the Garbage Management log IAW marpol. LEGACY COMPONENT DESC: Garbage Recordkeeping
Due 31 December 2003
Resolved 8 December 2003
Resolution: Received statement from Master
Documentation › Logs/Records
Issued 1 December 2003
Resolved
Vessel to provide receipt of ashore garbage disposal for the month of November. LEGACY COMPONENT DESC: Garbage Recordkeeping
Due 31 December 2003
Resolved 8 December 2003
Resolution: Received statement from Master.
Lifesaving
Issued 27 November 2001
Resolved
Oxygen and Acetylene bottles stowed port-side aft on the vessel tied down by line. Vessel to stow compressed gas bottles in a proper stowage rack.
Condition: Unknown
Due 29 December 2001
Resolved 28 January 2002
Resolution: High pressure bottles stowed in proper rack.
Lifesaving
Issued 27 November 2001
Resolved
Galley equipment tied of to a ladder in a crew stairwell located on deck "d" outside of cabin room 3010, blocking the escape route. Vessel to remove equipment and stow in proper area.
Condition: Unknown
Due 29 December 2001
Resolved 28 January 2002
Resolution: Galley equipment removed.
Fire Fighting
Issued 27 November 2001
Resolved
Vessels power operated fire screen doors close extremely fast (4 secs). Class Society to board vessel and determine if doors need adjustment. Class Society to provide report to MSO San Juan with results. 28JAN02: Requirement due date extended until 01FEB02. Class society (BV) will attend vessel
Condition: Unknown
Due 1 February 2002
Resolved 6 February 2002
Resolution: Resolved based on fax received from Flag State.
Lifesaving
Issued 27 November 2001
Resolved
Large breaker box stowed in the engine control room behind the main switchboard. EOW stated breaker box should be stowed in the vessel's workshop. Breaker box to be stowed in proper area._x001C_ _x001C_
Condition: Unknown
Due 29 December 2001
Resolved 28 January 2002
Resolution: Breaker box removed.
Accommodation/Occupational Safety
Issued 7 March 2000
Resolved
PROVIDE IMO SYMBOLS WHICH SHOW ESCAPE ROUTES AND FIRE EQUIPMENT THAT CONFORM TO LOW LEVEL LIGHTING RESOLUTION A752(18) NO HIGHER THAN 300MM ABOVE THE DECK, NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000
Resolved
REPAIR/REPLACE INOPERATIVE SMOKE DETECTOR IN DRY STORES SPACE DECK C FRAME 210-205 STARBOARD SIDE NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Accommodation/Occupational Safety
Issued 7 March 2000
Resolved
PROVIDE LOW LEVEL LIGHTING IAW SOLAS 74/78 IMO RESOLUTION A752(18) IN #1 FWD STAIR TOWER, #1 AFT STAIR TOWER, AND #6 AFT STAIR TOWER NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Documentation
Issued 7 March 2000
Resolved
PROVIDE OPERATIONAL LIMITATIONS MANUAL APPROVED BY CLASS IAW SOLAS 74/78 CHV, REG 23 NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000
Resolved
ADJUST FSD TO LOBBY AT BOTTOM OF STAIR TOWER #3, LABEL DOOR AND ADJUST TO ALLOW FOR MORE RAPID CLOSURE NLT 14MAR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Accommodation/Occupational Safety
Issued 7 March 2000
Resolved
PROVIDE ALL WTD'S AND SLIDING FSD'S WITH DIRECTION OF OPENING IAW LOW LEVELLIGHTING RESOLUTION A752(18) NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000
Resolved
ADJUST FSD #210, DECK B FOR PROPER CLOSURE NLT 14MAR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000
Resolved
ADJUST FSD #15, DECK A STATUS SENSOR, TO INDICATE PROPERLY WHETHER DOOR IS CLOSED OR OPEN NLT 14MAR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000
Resolved
UPDATE FIRE CONTROL PLANS TO REFLECT VESSEL CHANGES AND EQUIPMENT RELOCATION, AND APPROVED BY FLAG/CLASS NLT 07JUN00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Lifesaving
Issued 7 March 2000
Resolved
PROVIDE LIFEBOAT LAUNCHING INSTRUCTIONS IN ENGLISH NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Unknown
Issued 7 March 2000
Resolved
PROVIDE MAINTENANCE PROCEDURE FOR CLEANING LAUNDRY EXHAUST DUCT VENT AT DECK F SCREEN AT REGULAR INTERVALS. INCLUDE PROCEDURES IN ISM MAINTENANCE DOCUMENTS APPROVED BY FLAG ADMINISTRATION NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000
Resolved
PROVIDE 2 FIREMANS OUTFITS IN MVZ #4 IAW SOLAS 74/78 REG 17 NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Unknown
Issued 16 December 1998
Resolved
REMOVE HOLD BACK LATCHES FROM FIRE SCREEN DOORS ON DECK A.
Condition: Unknown
Due 13 January 1999
Resolved 13 January 1999
Engineering
Issued 16 December 1998
Resolved
REPAIR AND TEST OILY WATER SEPARATOR
Condition: Unknown
Due 13 January 1999
Resolved 13 January 1999
Fire Fighting
Issued 17 December 1992
Resolved
REPAIR DRAFT STOPS B8T2, D7T2. SEE VSL DRAWINGS.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Accommodation/Occupational Safety
Issued 17 December 1992
Resolved
ADEQUATELY MARK EMERGENCY EXIT ROUTES FROM CREW AND PASSENGER SPACES.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Construction/Loadline
Issued 17 December 1992
Resolved
INSTALL QUICK ACTING WATERTIGHT DOOR ON "E" DECK STARBOARD AT FRAME 221.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Accommodation/Occupational Safety
Issued 17 December 1992
Resolved
PERMANENTLY REMOVE WASHER AND DRYER FROM SPACE AT FRAME 224 "D" DECK ADJOINING STAIRWELL.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Fire Fighting
Issued 17 December 1992
Resolved
INSTALL MISSING DRAFT STOPS AT C12T1, C11T1, B11T1, B12T1. SEE VSL DRAWING.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Electrical
Issued 17 December 1992
Resolved
INSTALL EMERGENCY LIGHTING IN STAIRWELL 7 ON "B" DECK
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Fire Fighting
Issued 17 December 1992
Resolved
VERIFY THAT ALL FIRE SCREEN DOORS FULLY CLOSE AND LATCH.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Accommodation/Occupational Safety
Issued 17 December 1992
Resolved
INSTALL PERMANENT NO SMOKING SIGNS IN ALL NO SMOKING AREAS.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Navigation
Issued 27 November 1992
Resolved
MAGNETIC STEERING COMPASS WAS 13 DEG DIFFERENT THAN GYRO. LOCAL VARIATION IS 5 DEG AND DEVIATION IS 2 DEG, LEAVING 9 DEG IN QUESTION. CREW RESPONSE WAS THAT FORWARD BOOM MOVEMENT GREATLY AFFECTS READINGS.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Navigation
Issued 27 November 1992
Resolved
MANEUVERING INFORMATION FACT SHEET WAS MISSING A TABLE AT WHICH SPEEDS BOW AND STERN THRUSTERS WERE EFFECTIVE.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Navigation
Issued 27 November 1992
Resolved
MANEUVERING INFORMATION FACT SHEET WAS MISSING WARNING STATEMENT AT THE BOTTOM.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Navigation
Issued 27 November 1992
Resolved
VESSEL HAD NO BLOCK DIAGRAM FOR STEERING GEAR CHANGE OVER AT THE MAIN STEERING STAND.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Engineering
Issued 27 November 1992
Resolved
VESSEL HAD NO BRIDGE INDICATORS FOR RPM OF EACH ENGINE.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Accommodation/Occupational Safety
Issued 27 November 1992
Resolved
VESSEL HAD NO MARPOL V PLAN. CG FURNISHED ONE.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Navigation
Issued 27 November 1992
Resolved
MANEUVERING INFORMATON FACT SHEET WAS MISSING A TABLE FOR SHAFT REVOLUTIONSAND REPRESENTATIVE SPEEDS.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Documentation
Issued 27 November 1992
Resolved
VESSEL HAD NO OIL TRANSFER PROCEDURES. "IT IS THE CREW MEMBER'S JOB TO KNOW WHAT TO DO." CG FURNISHED A SAMPLE COPY ALTHOUGH THE [name withheld] THAT IN 20 YEARS HE HAS NEVER NEEDED THEM BEFORE, INCLUDING MIAMI, PUERTO RICO, ETC.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992