MAURY USCG vessel records Sign in
← All vessels

CLUB MED 2

CLUB MED 2 is a 1992 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1992, most recently in February 2017, along with 56 deficiencies — 2 with no resolution recorded — and 2 operational controls.

Records from 1992 to 2017. Most recent: inspection, 6 February 2017.

Built
1992
Last inspected
6 February 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9007491 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
382741
Flag
FRANCE
—
Maury page id
psix-382741

Inspections, by type

…with no type recorded16
…past their stated due date1
Years with a record 19 calendar years (1992–2017)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it5053 - Simplified, Net Ton
5053 - Convention (Subpart B), Net Ton
1674 - Dead Weight, Ton
7671 - Displacement, Ton
14983 - Simplified, Gross Ton
14983 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MB 2 Tank Barge · MISLE 42643 · 21 March 2007 · activity 2892244

Inspection history · 43

6 February 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6082726
29 November 2016 COC-CVE Annual · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6048609
22 February 2016 COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5818861
19 January 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5799141
14 December 2015 PII Safety Exam · Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5780637
14 December 2010 Deficiency Check · COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3910249
15 November 2010 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3891394
29 March 2010 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3704626
22 December 2009 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3653875
15 December 2008 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3379842
2 February 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3140605
21 January 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3132628
10 December 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3112854
8 December 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3111759
16 November 2007 PII Safety Exam · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3099489
21 March 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2892244
12 December 2005 MARPOL Annex V Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2549746
30 December 2004 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2264700
26 November 2004 Ballast Water Examination · MARPOL Annex I Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2248288
23 February 2004 Administrative Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2011551
1 December 2003 Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1957443
25 November 2002 Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1683257
28 January 2002 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1481708
27 November 2001 Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1366677
7 March 2000 MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1365632
14 December 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 435870
9 December 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 812310
24 November 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 810293
31 March 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 488608
13 January 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 424505
16 December 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 423705
16 December 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 423877
20 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 883498
1 September 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 370456
1 September 1994 Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 864385
15 September 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 360889
16 June 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 358950
16 June 1993 Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 842291
19 April 1993 Administrative
Administrative · Commandant (CG-CVC) · Activity 1149671
15 February 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 690101
17 December 1992 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 831722
28 November 1992 Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1141821
27 November 1992 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 354788

Deficiency record · 56

Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 November 2016 No resolution recorded
Fire Control Plan has not been kept up to date. Two new crew cabins have been added in a space that used to be a sauna /spa area, SFP was on final review stage for Flag approval. Vessel representative was waiting for final flag approval to sent the SFP to MSC for review.
Action required: 705 - Other - as specified
Due 6 May 2017 — due date passed with no resolution recorded
Fire Fighting › Structural - A Class Divisions › Doors
Issued 29 November 2016 Resolved
PSCO found fire door not closing and blocked by the floor carpet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 29 November 2016
Resolution: Carper was removed and witnessed the correct operation of fire door. Corrected on the Spot.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 14 December 2015 Resolved
Doors and door frames in B class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that division. PSCO found a B-15 fire screen door adjacent to garbage room on portside damaged and not closing properly. 74 SOLAS 97 II-2/31.1.1.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 19 January 2016
Resolution: Crew adjusted and repaired door, as well as the doorstep, which properly renewed the necessary fire resistance of the door.
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 December 2015 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger. PSCO found excessive wastage on drainage elbow attached to the overboard discharge valve in the A/C room. 74 SOLAS 97 I/11.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 19 January 2016
Resolution: Vessel's crew replaced noted piping with a new section of piping.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 14 December 2015 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks, the minimum fire integrity of all bulkheads and decks shall be as prescribed in table 26.2. PSCO found section valve 8 space on deck D, and portside bunkering station to be missing of required fire protection insulation. 74 SOLAS 97 II-2/26.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 19 January 2016
Resolution: Vesse's crew replaced both sections of noted insulation that was missing.
Lifesaving › Lifeboat › Markings
Issued 15 November 2010 Resolved
Found NON-SOLAS approved retro-reflective tape on the underside of lifeboats 1-6 and also found unserviceable retro-reflective tape on topside of lifeboats.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 December 2010
Resolution: At the date of the survey it has been confrimed that all retro-reflective tapes have been satisfactorily replaced by SOLAS approved tapes on tops and on sides of the 10 lifeboats/tenders of the ship.
Stability › Weathertight Integrity › General
Issued 15 November 2010 Resolved
Knife edge on the weather tight door leading to the STBD mooring station is wasted and holed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 December 2010
Resolution: The knife edge of the watertight fdoor leading to the starboard aft morring station Fr 16 has been satisfactory repaired.
Fire Fighting › Means of Escape › Corridors
Issued 15 November 2010 No resolution recorded
Found plywood and plastic sheets and general items stored in passage way leading to paint locker deck D.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolution: At the date of the survey, the passageway leading to the paint locker was observed free of material, or equipment that can block a free escape.
Fire Fighting › Means of Escape › Stairways
Issued 15 November 2010 Resolved
Found chairs stored under stairway . Deficiency corrected on spot.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 November 2010
Resolution: Corrected on the spot.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 15 November 2010 Resolved
Found unsecured oxygen and acetylene bottles held in place by rope. Deficiency rectified on the spot.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 November 2010
Resolution: Deficiency rectified on the spot.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 15 November 2010 Resolved
Structural fire protection missing above door leading out of the STBD bunker station, deck C.
Action required: 705 - Other - as specified
Resolved 15 December 2010
Resolution: The structural fire protection has been satisfactorily restored as per the approved structial fire protection drawing above the door frame 192 leading to the starboard side bunker station.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 15 November 2010 Resolved
The Notice of Arrival was incomplete in that it was missing two of the five ports required by 33 CFR 160.206.
Due 15 November 2010
Resolved 15 November 2010
Resolution: While onboard vessel for COC-CVE exam discussed importance with Master [name withheld] and [name withheld] the importance of submitting the last five ports of call on the Notice of Arrival.
Engineering › Steering Gear System › Piping
Issued 22 December 2009 Resolved
Hydraulic fluid is not being cleaned and presents a safety hazard. 74 SOLAS (97 CONSED) Ch II-1 Part C Reg. 29.12.1
Action required: 15 - Rectify deficiencies by next port
Resolved 29 March 2010
Resolution: steering gear does appear to be maintained and no major leaks are present.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 22 December 2009 Resolved
Door #1 on deck going into battery room is corroding at the bottom of the door compromising weathertight integrity. ICLL 66 Annex I Ch II Reg 12 (1)
Action required: 15 - Rectify deficiencies by next port
Resolved 29 March 2010
Resolution: bottom side of the door was cut and renewed.
Accommodation/Occupational Safety › Ventilation › General
Issued 22 December 2009 Resolved
Exhaust fan for engine room exhaust trunk presents a hazard due to a protective cover not installed and moving parts present. 74 SOLAS (97 CONSED) CH II-1 Part c Reg 26.1
Action required: 15 - Rectify deficiencies by next port
Resolved 29 March 2010
Resolution: Fan belt cover was replaced.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 16 November 2007 Resolved
ENSURE ALL WASTE RECEPTICALS ARE MADE OF NON-COMBUSTIBLE MATERIALS THROUGH THROUGHOUT THE VESSEL.
Action required: 705 - Other - as specified
Due 16 December 2007
Resolved 15 December 2008
Resolution: Conducted CVE Annual in Saint John, U.S.V.I. and verified non-combustible materials are being used throughout the vessel.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 November 2004 Resolved
Vessel's OWS is in disrepair. Vessel to retain onboard all oily waste & dispose of ashore. Flag/Class to board vessel & provide a report on OWS condition prior to December 29, 2004.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 30 December 2004
Resolution: Witnessed a sat operational test of OWS
Personnel › Training › Crowd Management
Issued 26 November 2004 Resolved
Vessel to provide alternate crew muster leaders for muster stations #7 & #8.
Due 29 December 2004
Resolved 30 December 2004
Resolution: Captain provided list with alternate crew muster leaders.
Lifesaving › Launching Appliances › Davit
Issued 26 November 2004 Resolved
Vessel to prove proper operation of davit launched liferaft to attending Coast Guard marine Inspector prior to December 29, 2004.
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 30 December 2004
Resolution: Witnessed a sat liferaft deployment drill
Operations/Management › Lifesaving
Issued 1 December 2003 Resolved
Vessel to provide proof of submital of SAR Plan of Cooperation IAW Solas 74 as amended V/7.3. LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Due 31 December 2003
Resolved 23 February 2004
Documentation › Logs/Records
Issued 1 December 2003 Resolved
Vessel to properly fill out the Garbage Management log IAW marpol. LEGACY COMPONENT DESC: Garbage Recordkeeping
Due 31 December 2003
Resolved 8 December 2003
Resolution: Received statement from Master
Documentation › Logs/Records
Issued 1 December 2003 Resolved
Vessel to provide receipt of ashore garbage disposal for the month of November. LEGACY COMPONENT DESC: Garbage Recordkeeping
Due 31 December 2003
Resolved 8 December 2003
Resolution: Received statement from Master.
Lifesaving
Issued 27 November 2001 Resolved
Oxygen and Acetylene bottles stowed port-side aft on the vessel tied down by line. Vessel to stow compressed gas bottles in a proper stowage rack.
Condition: Unknown
Due 29 December 2001
Resolved 28 January 2002
Resolution: High pressure bottles stowed in proper rack.
Lifesaving
Issued 27 November 2001 Resolved
Galley equipment tied of to a ladder in a crew stairwell located on deck "d" outside of cabin room 3010, blocking the escape route. Vessel to remove equipment and stow in proper area.
Condition: Unknown
Due 29 December 2001
Resolved 28 January 2002
Resolution: Galley equipment removed.
Fire Fighting
Issued 27 November 2001 Resolved
Vessels power operated fire screen doors close extremely fast (4 secs). Class Society to board vessel and determine if doors need adjustment. Class Society to provide report to MSO San Juan with results. 28JAN02: Requirement due date extended until 01FEB02. Class society (BV) will attend vessel
Condition: Unknown
Due 1 February 2002
Resolved 6 February 2002
Resolution: Resolved based on fax received from Flag State.
Lifesaving
Issued 27 November 2001 Resolved
Large breaker box stowed in the engine control room behind the main switchboard. EOW stated breaker box should be stowed in the vessel's workshop. Breaker box to be stowed in proper area._x001C_ _x001C_
Condition: Unknown
Due 29 December 2001
Resolved 28 January 2002
Resolution: Breaker box removed.
Accommodation/Occupational Safety
Issued 7 March 2000 Resolved
PROVIDE IMO SYMBOLS WHICH SHOW ESCAPE ROUTES AND FIRE EQUIPMENT THAT CONFORM TO LOW LEVEL LIGHTING RESOLUTION A752(18) NO HIGHER THAN 300MM ABOVE THE DECK, NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000 Resolved
REPAIR/REPLACE INOPERATIVE SMOKE DETECTOR IN DRY STORES SPACE DECK C FRAME 210-205 STARBOARD SIDE NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Accommodation/Occupational Safety
Issued 7 March 2000 Resolved
PROVIDE LOW LEVEL LIGHTING IAW SOLAS 74/78 IMO RESOLUTION A752(18) IN #1 FWD STAIR TOWER, #1 AFT STAIR TOWER, AND #6 AFT STAIR TOWER NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Documentation
Issued 7 March 2000 Resolved
PROVIDE OPERATIONAL LIMITATIONS MANUAL APPROVED BY CLASS IAW SOLAS 74/78 CHV, REG 23 NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000 Resolved
ADJUST FSD TO LOBBY AT BOTTOM OF STAIR TOWER #3, LABEL DOOR AND ADJUST TO ALLOW FOR MORE RAPID CLOSURE NLT 14MAR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Accommodation/Occupational Safety
Issued 7 March 2000 Resolved
PROVIDE ALL WTD'S AND SLIDING FSD'S WITH DIRECTION OF OPENING IAW LOW LEVELLIGHTING RESOLUTION A752(18) NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000 Resolved
ADJUST FSD #210, DECK B FOR PROPER CLOSURE NLT 14MAR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000 Resolved
ADJUST FSD #15, DECK A STATUS SENSOR, TO INDICATE PROPERLY WHETHER DOOR IS CLOSED OR OPEN NLT 14MAR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000 Resolved
UPDATE FIRE CONTROL PLANS TO REFLECT VESSEL CHANGES AND EQUIPMENT RELOCATION, AND APPROVED BY FLAG/CLASS NLT 07JUN00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Lifesaving
Issued 7 March 2000 Resolved
PROVIDE LIFEBOAT LAUNCHING INSTRUCTIONS IN ENGLISH NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Unknown
Issued 7 March 2000 Resolved
PROVIDE MAINTENANCE PROCEDURE FOR CLEANING LAUNDRY EXHAUST DUCT VENT AT DECK F SCREEN AT REGULAR INTERVALS. INCLUDE PROCEDURES IN ISM MAINTENANCE DOCUMENTS APPROVED BY FLAG ADMINISTRATION NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Fire Fighting
Issued 7 March 2000 Resolved
PROVIDE 2 FIREMANS OUTFITS IN MVZ #4 IAW SOLAS 74/78 REG 17 NLT 07APR00.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Unknown
Issued 16 December 1998 Resolved
REMOVE HOLD BACK LATCHES FROM FIRE SCREEN DOORS ON DECK A.
Condition: Unknown
Due 13 January 1999
Resolved 13 January 1999
Engineering
Issued 16 December 1998 Resolved
REPAIR AND TEST OILY WATER SEPARATOR
Condition: Unknown
Due 13 January 1999
Resolved 13 January 1999
Fire Fighting
Issued 17 December 1992 Resolved
REPAIR DRAFT STOPS B8T2, D7T2. SEE VSL DRAWINGS.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Accommodation/Occupational Safety
Issued 17 December 1992 Resolved
ADEQUATELY MARK EMERGENCY EXIT ROUTES FROM CREW AND PASSENGER SPACES.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Construction/Loadline
Issued 17 December 1992 Resolved
INSTALL QUICK ACTING WATERTIGHT DOOR ON "E" DECK STARBOARD AT FRAME 221.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Accommodation/Occupational Safety
Issued 17 December 1992 Resolved
PERMANENTLY REMOVE WASHER AND DRYER FROM SPACE AT FRAME 224 "D" DECK ADJOINING STAIRWELL.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Fire Fighting
Issued 17 December 1992 Resolved
INSTALL MISSING DRAFT STOPS AT C12T1, C11T1, B11T1, B12T1. SEE VSL DRAWING.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Electrical
Issued 17 December 1992 Resolved
INSTALL EMERGENCY LIGHTING IN STAIRWELL 7 ON "B" DECK
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Fire Fighting
Issued 17 December 1992 Resolved
VERIFY THAT ALL FIRE SCREEN DOORS FULLY CLOSE AND LATCH.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Accommodation/Occupational Safety
Issued 17 December 1992 Resolved
INSTALL PERMANENT NO SMOKING SIGNS IN ALL NO SMOKING AREAS.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Navigation
Issued 27 November 1992 Resolved
MAGNETIC STEERING COMPASS WAS 13 DEG DIFFERENT THAN GYRO. LOCAL VARIATION IS 5 DEG AND DEVIATION IS 2 DEG, LEAVING 9 DEG IN QUESTION. CREW RESPONSE WAS THAT FORWARD BOOM MOVEMENT GREATLY AFFECTS READINGS.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Navigation
Issued 27 November 1992 Resolved
MANEUVERING INFORMATION FACT SHEET WAS MISSING A TABLE AT WHICH SPEEDS BOW AND STERN THRUSTERS WERE EFFECTIVE.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Navigation
Issued 27 November 1992 Resolved
MANEUVERING INFORMATION FACT SHEET WAS MISSING WARNING STATEMENT AT THE BOTTOM.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Navigation
Issued 27 November 1992 Resolved
VESSEL HAD NO BLOCK DIAGRAM FOR STEERING GEAR CHANGE OVER AT THE MAIN STEERING STAND.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Engineering
Issued 27 November 1992 Resolved
VESSEL HAD NO BRIDGE INDICATORS FOR RPM OF EACH ENGINE.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Accommodation/Occupational Safety
Issued 27 November 1992 Resolved
VESSEL HAD NO MARPOL V PLAN. CG FURNISHED ONE.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Navigation
Issued 27 November 1992 Resolved
MANEUVERING INFORMATON FACT SHEET WAS MISSING A TABLE FOR SHAFT REVOLUTIONSAND REPRESENTATIVE SPEEDS.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992
Documentation
Issued 27 November 1992 Resolved
VESSEL HAD NO OIL TRANSFER PROCEDURES. "IT IS THE CREW MEMBER'S JOB TO KNOW WHAT TO DO." CG FURNISHED A SAMPLE COPY ALTHOUGH THE [name withheld] THAT IN 20 YEARS HE HAS NEVER NEEDED THEM BEFORE, INCLUDING MIAMI, PUERTO RICO, ETC.
Condition: Unknown
Due 30 November 1992
Resolved 30 November 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.