ENDEAVOUR is a freight ship. The Coast Guard has recorded 15 inspections since 1992, most recently in October 1996, along with 39 deficiencies and 2 operational controls.
Records from 1992 to 1996. Most recent: inspection, 25 October 1996.
- Built
- Not recorded
- Last inspected
- 25 October 1996
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 39 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
382743
Flag
DOMINICAN REPUBLIC
—
Maury page id
psix-382743
Inspections, by type
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it126 - Regulatory (Subpart C or D), Gross Ton
92 - Regulatory (Subpart C or D), Net Ton
92 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 15
25 October 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 396776
5 October 1996
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1147611
26 September 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 201410
26 September 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 395872
26 September 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 754929
25 June 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 379911
19 May 1995
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 379099
14 October 1994
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 371425
5 August 1994
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 369165
5 August 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363073
15 July 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 690011
7 July 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 359388
16 April 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 690012
23 March 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 357238
8 December 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 690010
Deficiency record · 39
Fire Fighting
Issued 26 September 1996
Resolved
SERVICE PORTABLE FIRE EXTINGUSHERS PRIOR TO DEPART US WATERS
Construction/Loadline
Issued 26 September 1996
Resolved
RENEW WATERTIGHT BULKHEAD BETWEEN CARGO HOLD AND LAZERETTE PRIOR TO RETURN_x001C_TO US WATERS
Construction/Loadline
Issued 26 September 1996
Resolved
RENEW LAZERETTE HATCH AND MAKE WATER TIGHT PRIOR TO RETURN TO US WATERS
Navigation
Issued 26 September 1996
Resolved
REPAIR STEERING STOCK BEARING TO THE SATISFICATION OF THE FLAG STATE PRIOR TO RETURN TO US WATERS
Navigation
Issued 26 September 1996
Resolved
RENEW STEERING STOPS PRIOR TO DEPART US WATERS
Navigation
Issued 26 September 1996
Resolved
REPLACE NAVIGATION LIGHT COVERS AND STEAMING LIGHT, PRIOR TO DEPART FROM US
Lifesaving
Issued 26 September 1996
Resolved
SERVICE LIFE RAFT PRIOR TO DEPART US WATERS
Documentation
Issued 26 September 1996
Resolved
PROVIDE LOAD LINE CERTIFICATE AND ITC TONNAGE CERTIFICATE PRIOR TO RETURN TO US WATERS
Fire Fighting
Issued 26 September 1996
Resolved
REPLACE FIRE PUMP WITH ARRANGEMENT ACCEPTABLE TO THE FLAG STATE. PROVIDE TEMPORARY FIRE PUMP PRIOR TO DEPART US WATERS
Fire Fighting
Issued 5 August 1994
Resolved
Provide 3 BII extiquishers and 1 BI extinguisher. In the following locations: BI=Bridge, BII's=2 in Engineroom, 1 in Galley area .
Documentation
Issued 5 August 1994
Resolved
Provide ltr of competency from flag state for first mate._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 5 August 1994
Resolved
Provide current deviation table for magnetic compass._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 5 August 1994
Resolved
Provide two independantly run fire pumps capable of 50PSI output with 100'of hose and nozzel._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 5 August 1994
Resolved
Provide documentation that all weather deck doors, hatches and fittings arewatertight.
Electrical
Issued 5 August 1994
Resolved
Provide battery boxes with cover for batteries._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 5 August 1994
Resolved
Make proper repairs to MDE._x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 5 August 1994
Resolved
PROVIDE PROPER GUARDS FOR SHIPS STOVE._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 5 August 1994
Resolved
Repair port running light and provide documnetation that lights meet rqmts foun in 72 Colregs._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 5 August 1994
Resolved
Remove excessive oil from bilges, provide proof of proper disposal._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 5 August 1994
Resolved
Provide adaquate working electrical system or other suitable means of electrical power._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 5 August 1994
Resolved
Provide working bilge pumping system._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 5 August 1994
Resolved
When carrying additional Liferaft onboard ensure that it is stowed in a float free manner._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 5 August 1994
Resolved
Repair or replace fractured/wasted framing and structural members as necessary._x001C_ _x001C_ _x001C_
Electrical
Issued 5 August 1994
Resolved
Provide chaffing gear for all electrical wiring going through bulkheads or decks._x001C_ _x001C_ _x001C_
Documentation
Issued 5 August 1994
Resolved
Provide a discharge of trash record book with proper entries and reciepts_x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 5 August 1994
Resolved
Provide rails or guards in vicinity of open hatches or dorways leading below decks._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 5 August 1994
Resolved
Provide two fixed fire main hydrants._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 5 August 1994
Resolved
Provide proper valves for all through hull fittings in engine room below the waterline._x001C_ _x001C_ _x001C_
Navigation
Issued 5 August 1994
Resolved
Provide keeper chain on rudder post._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 5 August 1994
Resolved
Provide proper draft markings on the hull_x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 5 August 1994
Resolved
Provide proper guards on all lighting fixtures throughout the vessel_x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 5 August 1994
Resolved
Repair lagging on exhaust for MDE and Generator._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 5 August 1994
Resolved
Remove or properly stow old batteries in engineroom._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 5 August 1994
Resolved
Provide proper storage to paint cans located throughuot the vsl._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 5 August 1994
Resolved
Remove propane tank and acetlyne bottles from lazerette and provide properstorage for same._x001C_ _x001C_ _x001C_
Engineering
Issued 5 August 1994
Resolved
Repair leak and provide drip bowl for fuel system on MDE_x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 7 July 1993
Resolved
VSL BOARDED FOR THE FOURTH TIME TO SEE IF IT HAD COMPLIED WITH COTP ORDER 32-93 INSTRUCTING IT TO HAVE AN OPERABLE MSD INSTALLED BEFORE IT RETURNED TO U.S. WATERS. IT DID NOT.
Accommodation/Occupational Safety
Issued 7 July 1993
Resolved
ON JUNE 15, 1993, UNDER COTP # 32-93 VESSEL WAS ORDERED NOT TO RETURN TO U.S. WATERS UNTIL AN APPROVED MSD WAS INSTALLED. ON JULY 7, 1993 THE VESSEL WAS SIGHTED AT ST. CROIX, U.S. VIRGIN ISLANDS. A BOARDING WAS CONDUCTED AND THE VESSEL STILL DID NOT HAVE A MARINE SANITATION DEVICE.
Accommodation/Occupational Safety
Issued 23 March 1993
Resolved
VESSEL HAS INSTALLED TOILETS BUT NO MARINE SANITATION DEVICE. THIS IS SECOND VIOLATION FOR SAME ITEM, DATED 09NOV92.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.