MAURY USCG vessel records Sign in
← All vessels

FALCON CARRIER

FALCON CARRIER is a 1991 tank ship. The Coast Guard has recorded 45 inspections since 1992, most recently in February 2009, along with 20 deficiencies — 1 with no resolution recorded — and 3 operational controls.

Records from 1992 to 2009. Most recent: inspection, 27 February 2009.

Built
1991
Last inspected
27 February 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9007776 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
382868
Flag
LIBERIA
—
Maury page id
psix-382868

Inspections, by type

…with no type recorded27
…past their stated due date1
Years with a record 16 calendar years (1992–2009)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it39036 - Convention (Subpart B), Gross Ton
39036 - Regulatory (Subpart C or D), Gross Ton
20208 - Convention (Subpart B), Net Ton
20208 - Regulatory (Subpart C or D), Net Ton
68147 - Dead Weight, Ton
82303 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 45

27 February 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3422751
9 January 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3391215
11 September 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3322548
19 June 2008 PII Safety Exam · COC-TVE Renew · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3241222
10 October 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2797326
6 October 2006 Ballast Water Examination · ISPS III Exam · COC-TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2795193
6 March 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2597117
1 March 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2594498
9 November 2005 ISPS III Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2531923
29 July 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2444671
25 July 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2439812
30 May 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2373197
6 April 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2327710
31 January 2005 ISPS III Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2282626
6 October 2004 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2214751
25 February 2003 Type not recorded
No type recorded · Station Portland · USCG Northwest District (CGD-NW) · Activity 1749526
13 January 2003 Re-Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1729838
5 November 2002 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1701236
6 June 2002 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1624561
5 June 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1626676
29 May 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1622456
28 April 2002 Ballast Water Examination · MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1610345
2 April 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 288748
1 October 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 282633
19 May 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 277940
16 May 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 277899
23 January 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 273823
9 March 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 426270
23 February 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 426343
21 January 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 424614
21 January 1999 Tank Vessel Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1125720
9 February 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 412815
3 March 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 401065
12 July 1996 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 393184
31 March 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389715
1 December 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 385260
16 March 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 375968
23 October 1994 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 491315
30 August 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 369985
28 July 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 867426
8 July 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 534085
22 February 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 480335
12 February 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1164958
26 January 1994 Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419209
27 November 1992 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1134616

Deficiency record · 20

Navigation › Collision/Grounding Avoidance › Radar
Issued 9 January 2009 Resolved
X-Band radar not operational. Provide technician's report attesting that the radar has been repaired prior to departure from the port of Guayanilla as required by Letter of Deviation (LOD) P-003-09 dated 09Jan09.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2009
Resolution: Received tech report and statement from vsl''''s master attesting that the radar was fixed and operational.//DC1
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 June 2008 Resolved
Electrical junction box on cargo deck in way of frame 180 is cracked around forward side of box. Repair to make vapor tight to satisfaction of class.
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 11 September 2008
Resolution: Received report from Lloyd''s Register that deficiency has been cleared to their satisfaction. In addition received statement from RSO (DNV) that item #4 has been addressed.
Deck/Cargo › Cargo Stowage › General
Issued 19 June 2008 Resolved
High high (Overfill) alarm visual not operational. Demonstrate operation of visual alarms prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2008
Resolved 19 June 2008
Resolution: Ship''s electrician repaired the visual aid during COC examination. USCG personnel witnessed satisfactory operation of the light prior to their departure.
Engineering › Steam System (main) › Piping
Issued 19 June 2008 No resolution recorded
Steam leak above cargo pump room in way of starboard side access ladder. Repair to satisfaction of class.
Action required: 705 - Other - as specified
Due 19 July 2008 — due date passed with no resolution recorded
Resolution: Received report from Lloyd''s Register that deficiency been cleared to their satisfaction.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 9 November 2005 Resolved
Cargo pump #2 has excessive leak. SOLAS 2001 Chapter II-1 C Reg. 26. Deficiency to be rectified to the satisfaction of attending class surveyor prior to next U.S. port after sailing foreign. Cargo pump #2 not to be used until proper repairs are attested to.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 March 2006
Resolution: Inspected by Class.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 9 November 2005 Resolved
Console in cargo control room has several small internal hydraulic leaks. SOLAS 2001 Chapter I Part B Reg. 11.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 December 2005
Resolved 6 March 2006
Resolution: Inspected and corrected by the crew.
Construction/Loadline › Structures › Door
Issued 31 January 2005 Resolved
Excessive wastage on access door,(port side, to-from after steering) turn-wheel handle.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 6 April 2005
Resolution: RECEIVED STATEMENT FROM MASTER
Electrical › Lighting (service)
Issued 28 April 2002 Resolved
Lighting fixture in cargo pump room must be intrinsically safe. Wire connection to existing fixture at midlle ladder rail location is unsat. Replace and provide class attestation of satisfactory repair. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 29 April 2002
Resolved 28 May 2002
Resolution: RECEIVED SAT CLASS REPORT ATTESTING TO COMPLETION.
Engineering › Steam System (auxiliary)
Issued 28 April 2002 Resolved
Replace in kind wasted/holed steam pipe at no. 2 port cargo tank. Provide class attestation of satisfactory repair. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 29 April 2002
Resolved 5 June 2002
Resolution: RECEIVED CLASS REPORT ATTESTING TO SAT COMPLIANCE WITH REQUIREMENT.
Navigation › Collision/Grounding Avoidance
Issued 28 April 2002 Resolved
Echo depth sounder inoperable. Repair prior to departing port or receive LOD from COTP to depart with inop equipment. Repair echo depth sounder prior to next US port. LEGACY COMPONENT DESC: Echo-sounding Device
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2002
Resolved 28 May 2002
Resolution: RECEIVED SAT CLASS REPORT.
Documentation › Certificates/Documents
Issued 28 April 2002 Resolved
Class to address issuance of ISM Safety Management Certificate; validity date exceeds five years. LEGACY COMPONENT DESC: Safety Management Certificate (ISM)
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 29 April 2002
Resolved 28 May 2002
Resolution: RECEIVED SAT CLASS REPORT.
Engineering › Sea-water System (primary cooling)
Issued 28 April 2002 Resolved
Sea water service line leaking on starboard side inboard of main sea suction valve. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 28 May 2002
Resolved 13 November 2002
Resolution: Received statement from vessel master dated 10NOV02 attesting the correction of deficiency.
Documentation › Certificates/Documents
Issued 28 April 2002 Resolved
Provide class report addressing each item (1-4) attesting to satisfactory repair/completion prior to next US port.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 29 April 2002
Resolved 28 May 2002
Resolution: RECEIVED SAT CLASS REPORT.
Deck/Cargo
Issued 19 May 2000 Resolved
Vessel does not meet the requirements of 33 CFR 155.480. Specifically; a) overfill alarm is not independent of cargo gauging system, b) no self test feature, and c) does not alarm in case of loss of power. Vessel must provide required overfill alarm prior to next cargo operations in U.S.
Condition: Unknown
Due 1 October 2000
Resolved 1 October 2000
Deck/Cargo
Issued 23 January 2000 Resolved
PROVIDE OVERFILL ALARMS WHICH ARE AUDIBLE AND VISIBLE FROM THE CARGO DECK AREA IN ACCORDANCE WITH 33CFR155.480 PRIOR TO LOADING CARGOES IN U.S. WATERS WHICH REQUIRE ALARMS BUT NO LATER THAN 23FEB00.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Lifesaving
Issued 21 January 1999 Resolved
Sprinkler system on port lifeboat inoperative.
Condition: Unknown
Due 26 January 1999
Resolved 26 January 1999
Navigation
Issued 21 January 1999 Resolved
Forward anchor light housing wasted and fixture is loose. Repair or replace prior to next U.S. voyage.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Deck/Cargo
Issued 12 February 1994 Resolved
UPDATE AND PROVE PROPER OPERATION OF THE OIL DISCHARGE MONITORING EQUIPMENTTO THE IMO STANDARD FOR RATE OF DISCHARGE OF 30L/NM PER FLAG STATE WAIVER LTR DTD 09FEB94.
Condition: Unknown
Due 12 February 1994
Resolved 12 February 1994
Electrical
Issued 26 January 1994 Resolved
RELOCATE PAINT IN FWD BOSN STORES TO AN AREA WIRED FOR HAZARDOUS ATMOSPHEREBEFORE NEXT PORT CALL IN U.S. (SOLAS CHAP II-1, REG 45 5.4)
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Deck/Cargo
Issued 26 January 1994 Resolved
INSTALL EQUIPMENT TO UPDATE CARGO DISCHARGE MONITOR TO NEW IMO STANDARD (30L/NM) OR OBTAIN WAIVER LETTER FROM FLAG STATE._x001C_ IMO RES. MEPC.5(32)_x001C_ MVI LTR 22-93
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994

Ownership record