Records from 1992 to 2022. Most recent: inspection, 10 February 2022.
Inspection history · 61
10 February 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7395121
24 November 2021
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7356013
26 February 2021
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7147111
16 October 2020
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7078722
25 March 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6942629
15 October 2019
Annual Inspection · In-Service Inspection · Administrative Inspection · Deficiency Check · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6845024
5 October 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6828588
18 October 2018
Annual Inspection · Internal Structural Exam · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6564055
31 October 2017
COI Inspection · Hull Examination · Internal Structural Exam · DAPI Audit · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6306283
3 February 2017
Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6080038
5 February 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5834872
18 December 2015
Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5800841
5 January 2012
DAPI Audit · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4219306
26 July 2011
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4094928
22 July 2011
Drydock Extension
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4090684
1 July 2011
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4070691
24 February 2011
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3951894
14 January 2011
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3920616
17 December 2010
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3914000
20 October 2010
Hull Examination · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3873251
15 January 2010
Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3664677
10 December 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3376540
17 October 2008
DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3346819
5 November 2007
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3093545
12 February 2006
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2586792
10 January 2006
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2709484
14 January 2005
Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2472597
11 June 2004
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2135544
11 November 2003
Deficiency Check · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1950972
20 September 2003
Damage Survey · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1922564
20 September 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1929220
6 February 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1746758
10 January 2003
Hull Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1735949
8 November 2002
COI Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1699575
14 December 2001
Deficiency Check · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1485314
9 January 2001
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361960
5 November 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381722
26 March 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1469894
4 February 1999
Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1429086
21 August 1998
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 798085
2 June 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 132514
21 November 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383717
21 March 1997
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1431751
29 January 1997
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1102888
8 November 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356007
20 May 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1083835
20 March 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 16223
16 November 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357395
13 July 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 712783
23 June 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1400189
9 January 1995
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1394246
14 December 1994
Hull Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1398169
4 November 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 707216
6 October 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 372134
3 February 1994
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1373974
16 December 1993
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1434065
26 April 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 836365
12 April 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1145523
31 March 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1143802
31 December 1992
Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1139187
13 December 1992
Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1359460
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 February 2022
No resolution recorded
During the drydock examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. The main deck, aft of the water holding tank, is wasted. Provide scaffolding or ladders to enable USCG Marine Inspectors to inspect the extent of the wastage. 46CFR176.610(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 November 2019
No resolution recorded
The owner or managing operator shall submit drawings, sketches, or written specs describing details of any proposed altercation to the [name withheld] has been modified without proper documentation on file. Original General Arrangement plan approved in 1992 does not show conversion of photo lab to a overnight accommodation space, additional bunks in upper starboard accommodation space, location of washer/dryer, etc. Submit accurate General Arrangement Plan for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 15 November 2019
Resolved
When furnishings and mattresses are renewed, they must comply with 46 CFR 177.405(g). Solid foam queen mattresses are installed in crew/passenger bunks. Provide proof of mattresses with 177.405(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019
Resolved 30 November 2019
Resolution: All the mattresses where renewed and comply with 46 CFR 177.405(g).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 November 2019
No resolution recorded
The owner or managing operator shall submit drawings, sketches, or written specs describing details of any proposed altercation to the [name withheld] plans approved in 1992 is not an accurate reflection of current onboard electrical equipment (ie, bridge navigation equipment, A/C units, etc). Submit plans to the Marine Safety Center for review to include a load analysis for compliance with 46 CFR part 183.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 15 November 2019
Resolved
Aisles leading to means of escape shall be no less than 24 inches. Doorway openings for main deck passenger accommodations measured 22 1/2 inches wide. Pre-hung solid wooden doors have been installed in into the original aluminum bulkhead cut out and shimmed approx 1-2 inches on each side into place. Install doors in accordance with original approved plans or comply with existing means of escape requirements of 46 CFR 177.500(e).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019
Resolved 25 March 2020
Resolution: The vessel owner/ operator that the vessel widened all passenger and crew doorway openings to more than 24 inches.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 November 2019
No resolution recorded
The owner or managing operator shall submit drawings, sketches, or written specs describing details of any proposed altercations to the OCMI. A/C compressors are installed in passenger and crew accommodations beneath bunks w/out proof of approval. Provide documentation of prior Coast Guard approval of installation or submit plans for approval. Submission shall include manufacturers specifications of equipment and intended use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2019 — due date passed with no resolution recorded
Communications › Public Address System › Announcing Station
Issued 3 February 2017
Resolved
Vessel is to have a working public address station installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 3 March 2017
Resolution: The vessel has a properly operating public address system.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 February 2017
Resolved
Vessel needs to provide a guard around exposed rotating machinery.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 3 March 2017
Resolution: The vessel installed guard rails around rotating machinery.
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 February 2017
Resolved
All vessel high bilge alarms need to be capable of an audible and visual indicator while in operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 3 March 2017
Resolution: The vessel has operable high bilge alarms.
Communications › Radio Communications › VHF Radiotelephone
Issued 3 February 2017
Resolved
Vessel needs to have a valid FCC Safety Certificate onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 3 March 2017
Resolution: The vessel has a valid FCC Safety Certificate.
Communications › Alarms/Indicators › Fire Alarm
Issued 3 February 2017
Resolved
Vessel needs a working audible and visual indicator for the port engine bridge sensor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 3 March 2017
Resolution: The vessel has a working audible and visual indicator for the port engine bridge sensor.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 3 February 2012
Resolved
Stop excessive leaking of port/starboard fire pumps located in engine rooms and prove proper operation and adequate water pressure at aft fire station IAW 46 CFR 181.300
Due 3 March 2012
Resolved 23 March 2012
Fire Fighting › Fire Main › Condition
Issued 3 February 2012
Resolved
Renew fire main piping that has a pin hole leak in way of port forward storage void IAW 46 CFR 182.710
Due 3 March 2012
Resolved 23 March 2012
Stability › Watertight Integrity › General
Issued 3 February 2012
Resolved
Make starboard forward void watertight in way of electrical bulkhead penetration.
Due 3 March 2012
Resolved 23 March 2012
Documentation › Certificates/Documents › Stability Letter
Issued 3 February 2012
Resolved
Mount stability letter addendum showing compliance with 185 lb AAWPP effective Dec. 1, 2011 with stability letter IAW 46 CFR 176.306
Due 3 March 2012
Resolved 3 February 2012
Communications › Public Address System › Loudspeaker
Issued 3 February 2012
Resolved
Prove operation of public address system IAW 46 CFR 184.610
Due 3 March 2012
Resolved 3 February 2012
Stability › Watertight Integrity › General
Issued 3 February 2012
Resolved
Make starboard engine room watertight in way of water leaks in overhead and exhaust IAW 46 CFR 176.830
Due 3 March 2012
Resolved 23 March 2012
Stability › Watertight Integrity › General
Issued 3 February 2012
Resolved
Identify and stop source of water leaking in the #5 cabin IAW 46 CFR 176.830
Due 3 March 2012
Resolved 23 March 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 February 2012
Resolved
Properly cap/secure live wiring to port/starboard engine exhaust fans IAW 46 CFR 176.830
Due 3 March 2012
Resolved 23 March 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 January 2011
Resolved
Properly mount all electrical wiring in way of all spaces below the main deck in accordance with 46 CFR 183.340.
Due 28 February 2011
Resolved 25 February 2011
Engineering › Freshwater Generation System › Pump
Issued 28 January 2011
Resolved
Properly mount low pressure water pump in way of port lazarette.
Due 28 February 2011
Resolved 25 February 2011
Engineering › Freshwater System (air cooling) › Pump
Issued 28 January 2011
Resolved
Properly/permanently mount A/C raw/fresh water circulating pumps in way of port forward void.
Due 28 February 2011
Resolved 25 February 2011
Stability › Watertight Integrity › General
Issued 28 January 2011
Resolved
Make port stern watertight hatch watertight.
Due 28 February 2011
Resolved 25 February 2011
Engineering › Bilge Water Management System › Not Operational
Issued 28 January 2011
Resolved
Provide manual bilge pump onboard.
Due 28 February 2011
Resolved 25 February 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 January 2011
Resolved
Remove all dead end wires in way of all spaces below the main deck.
Due 28 February 2011
Resolved 25 February 2011
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 28 January 2011
Resolved
Provide current safety radio telephony certificate onboard.
Due 28 February 2011
Resolved 24 February 2011
Resolution: Received a copy of a current safety radio telephony certificate.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 27 November 2010
Resolved
Renew/install gaskets for forward port and starboard watertight hatches.
Due 27 December 2010
Resolved 17 December 2010
Construction/Loadline › Penetrations › Valve Flange
Issued 27 November 2010
Resolved
Permanently renew leaking starboard sea chest valve. Currently there is a pinhole leak that has been temporally plugged.
Due 27 November 2010
Resolved 28 January 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 November 2010
Resolved
Install heat shield or lagging for port and starboard engine exhaust piping in way of engine rooms.
Due 27 December 2010
Resolved 17 December 2010
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 27 November 2010
Resolved
Install and prove operation of starboard engine room fixed fire extinguisher. Vessel is to carry additional portable fire extinguishers till new fixed system is installed.
Due 27 December 2010
Resolved 28 February 2011
Engineering › Fuel Oil Service System › Hose
Issued 27 November 2010
Resolved
Prove port engine room installed flexible fuel lines meet the requirements of 46CFR182.720(e). If flexible fuel lines do not meet requirements replace.
Due 27 December 2010
Resolved 28 January 2011
Engineering › Generator (propulsion-electric) › Measurement Circuitry
Issued 27 November 2010
Resolved
Renew/prove operation of port generator indicator gauges.
Due 27 December 2010
Resolved 28 January 2011
Engineering › Bilge Water Management System › Piping
Issued 27 November 2010
Resolved
Properly mount port bilge piping in way of engine room.
Due 27 December 2010
Resolved 17 December 2010
Construction/Loadline › Hull › Hull Plating
Issued 26 October 2010
Resolved
Submit plans for USCG approval in accordance with 46CFR176.700 for all hull and framing repair/replacement to be conducted on vessel while in drydock. Plans are to include specifications of existing scantlings that are to be removed, replacement material to be used, specifications and location of inserts, and weld procedures. Plans must be approved prior to conducting any fit up on vessel.
Action required: 705 - Other - as specified
Due 8 November 2010
Resolved 29 October 2010
Lifesaving › Lifefloat › Serviceable
Issued 15 January 2010
Resolved
Found numerous areas on the bottom side of life float which requires maintainance. Make proper repairs to affected areas of life float i.a.w. manufactures recommendations. (repair cracks and splits) (46 CFR 185.700)
Action required: 705 - Other - as specified
Due 29 January 2010
Resolved 29 January 2010
Lifesaving › Buoyant Apparatus › Lifeline
Issued 15 January 2010
Resolved
Found life lines in degraded condition due to weathering. Replace all grablines on port ring buoy i.a.w. 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 29 January 2010
Resolved 29 January 2010
Lifesaving › Lifefloat › Float-free Link
Issued 15 January 2010
Resolved
Found expired hydrostatic release on life float. Replace expired float free link. 46 CFR 180.137(b)
Action required: 705 - Other - as specified
Due 29 January 2010
Resolved 29 January 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 January 2010
Resolved
Install machinery guard on service generator in port engine room i.a.w. 46 CFR 177.970
Action required: 705 - Other - as specified
Due 29 January 2010
Resolved 12 February 2010
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 January 2010
Resolved
Provide and post original valid Certificate of Documentation. 46 CFR 67.7
Action required: 705 - Other - as specified
Due 29 January 2010
Resolved 29 January 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 January 2010
Resolved
Provide proof of annual servicing for fixed and portable fire extinguishing systems. 46 CFR 176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 January 2010
Resolution: Vessel was serviced on this date for the fixed and portable fire extinguishing systems.
Engineering › Bilge Water Management System › Strainer
Issued 10 December 2008
Resolved
Provide (2) strainers for bilge suction in two aft spaces.
Due 5 January 2009
Resolved 9 January 2009
Stability › Watertight Integrity › General
Issued 10 December 2008
Resolved
Replace gasket on stbd aft hatch and make space watertight.
Due 5 January 2009
Resolved 9 January 2009
Construction/Loadline › Hull › Side Shell
Issued 10 December 2008
Resolved
Reweld area of undercutting located on top of exhaust in stbd engine room.
Due 5 January 2009
Resolved 9 January 2009
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 10 December 2008
Resolved
Provide specifications for fabric used to cover bench seats in main salon. Materials must meet 46 CFR 177.410 and 46 CFR 116.423.
Due 5 January 2009
Resolved 9 January 2009
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 October 2008
Resolved
Ring located on starboard side was not peroperly marked with vessel name and hailing port.
Due 17 November 2008
Resolved 7 November 2008
Fire Fighting › Firemans Outfit › Axe
Issued 17 October 2008
Resolved
Fire ax was not properly marked with vessel name.
Due 17 November 2008
Resolved 7 November 2008
Lifesaving › Lifebuoys › Serviceable
Issued 17 October 2008
Resolved
Ring buoy on dive deck is missing grab line, retro reflective tape was worn and vessel name was illegible.
Due 17 November 2008
Resolved 7 November 2008
Lifesaving › Lifefloat › Serviceable
Issued 17 October 2008
Resolved
Found several cracks in outer coating of lifefloat. Make proper repairs per manufacturers instructions.
Due 17 November 2008
Resolved 7 November 2008
Engineering › Bilge Water Management System › Not Operational
Issued 17 October 2008
Resolved
Visual indicator for high level bilge alarm in stbd engine room was burned out. Prove operation of visual indicator.
Due 17 November 2008
Resolved 7 November 2008
Fire Fighting › Grease Extraction Hood › General
Issued 17 October 2008
Resolved
Replace/repair oven filter cover; metal cover was missing.
Due 17 November 2008
Resolved 7 November 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 November 2007
Resolved
Provide current copies of U.S. Coast Pilot, Tide & Current Tables, and USCG Light List.
Due 19 November 2007
Resolved 20 November 2007
Lifesaving › Lifefloat › Serviceable
Issued 5 November 2007
Resolved
Remove non-serviceable lifefloat from vessel.
Due 19 November 2007
Resolved 20 November 2007
Lifesaving › Lifefloat › Lifeline
Issued 5 November 2007
Resolved
Replace deteriorated lifeline
Due 19 November 2007
Resolved 20 November 2007
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 5 November 2007
Resolved
Label (2) PFD's with vessel name.
Due 19 November 2007
Resolved 20 November 2007
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 November 2007
Resolved
Renew retroreflective tape on (1) PFD.
Due 19 November 2007
Resolved 20 November 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 10 January 2006
Resolved
Prove satisfactory servicing of all portable fire extinguishers
Due 10 February 2006
Resolved 10 February 2006
Documentation › Certificates/Documents › FCC SSL
Issued 10 January 2006
Resolved
Obtain valid safety radiotelephony certificate
Due 10 February 2006
Resolved 10 February 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 January 2005
Resolved
Post new SPV decal
Due 4 March 2005
Resolved 11 February 2005
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 January 2005
Resolved
Provide a list of employees covered under the drug & alcohol program.
Due 4 March 2005
Resolved 11 February 2005
Lifesaving › Lifefloat › Float-free Link
Issued 14 January 2005
Resolved
Obtain new weak-link to lifefloat and make float dark orange in color
Due 4 March 2005
Resolved 11 February 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 January 2005
Resolved
Replace line to liferings
Due 4 March 2005
Resolved 11 February 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 January 2005
Resolved
Prove proper logs are being kept for drills and that 100% of crew conduct at least 1 drill per quarter.
Due 4 March 2005
Resolved 11 February 2005
Navigation › Collision/Grounding Avoidance
Issued 21 November 2003
Resolved
Install dive lights per navigation rules. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 20 December 2003
Resolved 14 April 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 22 September 2003
Resolved
Repair the port & stbd fixed fire-extinguishing systems.
Action required: 705 - Other - as specified
Due 6 October 2003
Resolved 24 October 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 20 September 2003
Resolved
Service the discharged portable fire extinguisher and the port engine room fixed fire extinguisher prior to carrying passengers.
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 22 September 2003
Stability › Watertight Integrity
Issued 18 January 2003
Resolved
Replace the neoprene seals adjacent to the engine room and forward workspaces entrance.
Action required: 705 - Other - as specified
Due 19 February 2003
Resolved 5 April 2003
Operations/Management › Equipment Service/Testing
Issued 18 January 2003
Resolved
Prove proper operation of the pressure relief valves or install new relief valves that have been recently certified by the manufacturer.
Action required: 705 - Other - as specified
Due 19 February 2003
Resolved 3 February 2003
Stability › Watertight Integrity
Issued 18 January 2003
Resolved
Make permanent repairs to the holes in the upper part of the aft void compartments and rub rails.
Action required: 705 - Other - as specified
Due 9 February 2003
Resolved 9 May 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 January 2003
Resolved
Procure and install lagging on the port MDE flexible coupling.
Action required: 705 - Other - as specified
Due 19 February 2003
Resolved 5 April 2003
Communications › Alarms/Indicators
Issued 8 November 2002
Resolved
Provide visual bilge alarms at the operating station for all compartments required to have bilge high-level alarms. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 January 2003
Resolved 5 April 2003
Engineering › Fuel Oil Service System › Valve, Control
Issued 8 November 2002
Resolved
Repair the port & stbd F/O emergency securing valves.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 November 2002
Resolved 9 November 2002
Engineering › Bilge Water Management System
Issued 8 November 2002
Resolved
Repair the stbd bilge pump. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 18 January 2003
Engineering › Diesel Engine (auxiliary)
Issued 14 December 2001
Resolved
Replace the SSG's fuel hose with Coast Guard approved hoses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 January 2002
Resolved 29 March 2002
Navigation › Piloting/Steering
Issued 14 December 2001
Resolved
Provide a magnetic compass. LEGACY COMPONENT DESC: Magnetic Compass
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 January 2002
Resolved 29 March 2002
Communications › Radio Communications
Issued 14 December 2001
Resolved
Provide an additional VHF-FM radio in the pilot house and obtain a bridge to bridge radio certificate. LEGACY COMPONENT DESC: VFH Radiotelephone
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 January 2002
Resolved 29 March 2002
Lifesaving › Buoyant Apparatus
Issued 14 December 2001
Resolved
Provide a floating water light for the vessels life float.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 January 2002
Resolved 29 March 2002
Lifesaving
Issued 5 November 1999
Resolved
Found vessel to be missing three of the six required hand held red flares, 46 CFR 180.68. Vessel rep obtained three red hand flares prior to end of inspection.
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Lifesaving
Issued 4 February 1999
Resolved
Found Category I 406 EPIRB inoperable when activating the test system. Required vessel rep to prove EPIRB is operational.
Condition: Unknown
Due 2 April 1999
Resolved 2 April 1999
Fire Fighting
Issued 4 February 1999
Resolved
Vessel unable to perform emergency drills because not enough crew were present. Prove master and crew's efficiency in conducting emergency drills.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Lifesaving
Issued 4 February 1999
Resolved
Found life ring to be white in color. Required vessel rep to obtain orangering life buoy.
Condition: Unknown
Due 2 April 1999
Resolved 2 April 1999
Accommodation/Occupational Safety
Issued 21 November 1997
Resolved
Install pressure vessels for the marine head system which meet the requirements of 46 CFR 54.01-5(c)(4).
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Accommodation/Occupational Safety
Issued 21 November 1997
Resolved
Replace the lead wire seal on the bottom pressure vessel (high pressure bottle) relief valve in the starboard aft compartment.
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Electrical
Issued 21 November 1997
Resolved
Permanently mount the terminal board adjacent to the port fixed extinguishing system bottle.
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Electrical
Issued 23 June 1995
Resolved
Make proper repairs and prove proper operation of port generator exhaust system to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 23 June 1995
Resolved 26 June 1995
Construction/Loadline
Issued 9 January 1995
Resolved
REMOVE/REPAIR BUCKLED & FRACTURED BULKHEADS, FRAMES 13/14: FRAME 14, STB SIDE, 5 LONGITUDAL STIFFENERS TO PORT; FRAME 13, STB SIDE, 2 LONGITUDAL STIFFENERS TO PORT. SUBMIT WELDING PROCEDURES, REPAIR MATERIALS, & WELDERS QUALS TO CG INSPECT DEPT. VSL RESTRICTED FROM CARRYING PASSENGERS.
Condition: Unknown
Due 17 January 1995
Resolved 23 January 1995
Accommodation/Occupational Safety
Issued 6 October 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 October 1994
Resolved 4 November 1994
Accommodation/Occupational Safety
Issued 6 October 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 October 1994
Resolved 4 November 1994
Documentation
Issued 31 December 1992
Resolved
THE VESSEL'S HOT TUB MAY NOT BE USED UNTIL THE DECK BEAM STRUCTURAL PLAN HAS BEEN REVIEWED AND APPROVED.
Condition: Unknown
Due 31 December 1992
Resolved 31 December 1992
Documentation
Issued 31 December 1992
Resolved
CONDUCT A 110 PER CENT WEIGHT TEST OF THE BOAT DAVIT IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 31 December 1992
Resolved 31 December 1992
Documentation
Issued 31 December 1992
Resolved
THE VESSEL'S GAS GRILL MAY NOT BE USED UNTIL THE INSTALLATION PLAN HAS BEENREVIEWED AND APPROVED.
Condition: Unknown
Due 27 January 1993
Resolved 27 January 1993