Records from 1992 to 2017. Most recent: inspection, 15 February 2017.
Inspection history · 23
15 February 2017
Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 6100101
22 January 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3668480
15 March 2007
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2882775
6 February 2007
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2864812
6 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2595667
25 January 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2569086
21 August 2003
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1882909
15 August 2003
Re-Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1877323
8 August 2003
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1870973
14 February 2003
Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1744915
8 June 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 290865
14 February 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 274583
6 April 1998
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 414400
21 January 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 399639
10 September 1996
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 395224
5 February 1996
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 387615
16 January 1996
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 386894
25 October 1995
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 384056
4 October 1995
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 383299
11 July 1995
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 380286
18 April 1995
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 377467
24 May 1994
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 367087
4 December 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 354981
Electrical › Lighting (service) › Lighting Fixture
Issued 6 February 2007
Resolved
Found damaged overhead light bracket next to #2 MDE to be fractured/damaged.
Condition: Improper/Lack of Maintenance
Due 6 February 2007
Resolved 6 February 2007
Resolution: Crew corrected discrepancy (installed new light) during course of inspection.
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 6 February 2007
Resolved
Found numerous flanges (8 total) to be missing bolt fastening devices throughout engineering space.
Condition: Improper/Lack of Maintenance
Due 6 February 2007
Resolved 6 February 2007
Resolution: Crew corrected discrepancy (replaced nuts/bolts) during course of inspection.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 6 February 2007
Resolved
Found Fuel Oil Purifier (FOP) to have loose/exposed electrical wires.
Condition: Improper/Lack of Maintenance
Due 6 February 2007
Resolved 6 February 2007
Resolution: Crew corrected discrepancy (reinstalled/connected wires) during course of inspection.
Engineering › Steam System (main) › Piping
Issued 6 February 2007
Resolved
Found temporary "soft patch" on steam system pipe (under #1 MDE); issued requirement to repair prior to next U.S. port.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2007
Resolution: This deficiency was issued in error in MISLE activity 2864812. This vessel had no deficiences during last PSC exam.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 6 February 2007
Resolved
Found focsle exhaust fan actuating handle to be seized.
Condition: Improper/Lack of Maintenance
Due 6 February 2007
Resolved 6 February 2007
Resolution: Crew corrected discrepancy (correctly adjusted component) during course of inspection.
Deck/Cargo › Cargo Stowage › General
Issued 6 February 2007
Resolved
Found damaged light bracket (loose with exposed electrical wires) in #3 reefer hold; (A) deck.
Condition: Improper/Lack of Maintenance
Due 6 February 2007
Resolved 6 February 2007
Resolution: Crew corrected discrepancy (effected repairs to light) during course of inspection.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 6 February 2007
Resolved
Cooling fan in vegetable room had exposed wires and was missing cover for right fan blade. Right fan blade was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Resolution: New cooling unit (fan) was installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 15 August 2003
Resolved
Perform annual service of CO2 portable and fixed firefighting system. Note: Last serviced 10DEC2001. LEGACY COMPONENT DESC: Annual Servicing
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 September 2003
Resolved 21 August 2003
Resolution: Administratively cleared. Criteria for servicing not specifically annual. Servicing scheduled for November 2003 during drydock.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 14 February 2003
Resolved
Painter for Port liferaft not connected and hydrostatic release "bell" installed upside down.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2003
Resolved 14 February 2003
Resolution: Corrected prior to departing vessel.
Lifesaving › Inflatable Liferafts
Issued 14 February 2003
Resolved
Operating instructions for starboard liferaft is for "bell type" hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 February 2003
Resolved 12 August 2003
Resolution: Hammer instructions posted.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 14 February 2003
Resolved
Poisons "rat and roach" stowed in hospital space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2003
Resolved 14 February 2003
Resolution: Poisons removed from hospital.
Construction/Loadline › Structures
Issued 14 February 2003
Resolved
Port side main deck watertight door not watertight. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2003
Resolved 17 February 2003
Resolution: Cleared by CWO D.Pavlik.
Fire Fighting › Structural - A Class Divisions
Issued 14 February 2003
Resolved
Several fire doors can not be closed or sealed properly. 3 in engine room, 1 in emergency steering, and 1 fan room LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2003
Resolved 17 February 2003
Resolution: Cleared by CWO D.Pavlik
Fire Fighting › Portable Foam Applicators
Issued 14 February 2003
Resolved
Hose on portable foam extinguisher in engine room was wasted, cracked, dryrotted.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 February 2003
Resolved 12 August 2003
Resolution: Hose replaced with new hose.
Fire Fighting › Fire Hoses
Issued 14 February 2003
Resolved
Spanner wrenches missing from several hose stations in the engine room. LEGACY COMPONENT DESC: Connections
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2003
Resolved 17 February 2003
Resolution: Cleared by CWO D.Pavlik.
Lifesaving
Issued 14 February 2000
Resolved
IAW SOLAS 74 CHAPTER III REG 48/1.10 THE CREW COULD NOT RETREIVE THE PORTSIDE LIFEBOAT AFTER LOWERING IT TO THE WATER.
Condition: Unknown
Due 14 February 2000
Resolved 15 February 2000
Fire Fighting
Issued 16 January 1996
Resolved
INTERNATIONAL SHORE CONNECTION MISSING NECESSARY BOLTS, WASHERS, AND NUTS.
Condition: Unknown
Due 16 January 1996
Resolved 18 January 1996
Documentation
Issued 16 January 1996
Resolved
ENTRIES IN OIL RECORD BOOK WERE NOT IAW INSTRUCTIONS IN THE OIL RECORD BOOK.
Condition: Unknown
Due 18 January 1996
Resolved 18 January 1996
Lifesaving
Issued 4 October 1995
Resolved
Various medications in the ship's hospital were expired. Hospital was not in accordance with ILO-147.
Condition: Unknown
Due 4 January 1996
Resolved 6 February 1996
Navigation
Issued 4 October 1995
Resolved
Vessel transited U.S. waters using NOAA chart #18725. Chart was a September 1993 edition that was missing all 1994 Notice to Mariners corrections except 49/94.
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Documentation
Issued 4 October 1995
Resolved
1st and 3rd Engineers licenses had expired while on their current voyage. Vessel is not in compliance with STCW or ILO-147.
Condition: Unknown
Due 25 October 1995
Resolved 25 October 1995
Navigation
Issued 11 July 1995
Resolved
Vessel's NOAA chart #18725 was not currently corrected.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Lifesaving
Issued 11 July 1995
Resolved
Vessel's life rafts were missing weak links.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Documentation
Issued 18 April 1995
Resolved
THE VESSEL'S IOPP CERTIFICATE DID NOT REFLECT THAT THE VESSEL HAD AN APPROVED SOPEP AS REQUIRED BY 33CFR151.19(b). THE IOPP CERTIFICATE IS DUE TO BE ENDORCED BY 09JULY95, SO THE CLASS SOCIETY MUST CORRECT THE IOPP CERTIFICATE THEN.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995