SEA RUNNER is a freight ship. The Coast Guard has recorded 42 inspections since 2004, most recently in January 2010, along with 6 deficiencies and 18 operational controls.

Records from 2004 to 2010. Most recent: inspection, 16 January 2010.

Built
Not recorded
Last inspected
16 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7606645 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
382971
Flag
MALTA
—
Maury page id
psix-382971

Inspections, by type

…with no type recorded27
Years with a record 7 calendar years (2004–2010)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it10669 - Simplified, Gross Ton
10669 - Convention (Subpart B), Gross Ton
3201 - Convention (Subpart B), Net Ton
4924 - Dead Weight, Ton
3201 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 42

16 January 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3664935
5 January 2010 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3658742
2 December 2009 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3643388
6 July 2009 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3525540
17 March 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3435380
13 March 2009 COE-Offshore
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3433023
2 January 2009 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3387537
28 August 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3311019
4 August 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3289085
29 June 2008 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3251338
15 June 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3238030
19 September 2007 MARPOL Annex II Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3061304
22 May 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2947352
8 March 2007 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2884140
12 January 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2854849
11 January 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2853994
11 September 2006 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2775189
6 September 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2770480
10 October 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2511440
27 September 2005 ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2502035
8 August 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2456093
4 May 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2349368
3 May 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2348133
26 March 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2320065
22 March 2005 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2316224
3 March 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2302685
16 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2293889
16 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2297574
12 February 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2291220
2 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2285433
27 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2281916
26 January 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2281160
7 January 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2270390
9 December 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2256065
8 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2236721
6 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2235840
1 November 2004 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2232262
29 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2230719
26 August 2004 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2177141
26 August 2004 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2177255
12 August 2004 ISPS II Exam · Ballast Water Examination · PI Safety Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2161104
7 August 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2158622

Deficiency record · 6

Construction/Loadline › Hull › Hull Plating
Issued 15 June 2008 Resolved
Hole size 8'' x 8'' on forward starbrd side of vessel approximately located at fram 135, 9 foot above the waterline. master performed temporary repairs using epoxy patch. Repair hole to the satisfaction of class society and fax report to the USCG.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 June 2008
Resolved 28 June 2008
Resolution: Bureau Veritas certified temporary repairs have been completed at the forward fuel tank in way of frames 108-109.Permanent repairs will be completed at the vessel''s scheduled dry docking 209 September 2008.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 19 September 2007 Resolved
Starboard pipe leading to anchor wash; cracked and leaking water. Repair or replace to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2007
Resolved 1 October 2007
Resolution: Bureau Veritas Surveyor [name withheld] provided on Oct 1, 2007 certification of corrected discrepancy .
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 11 September 2006 Resolved
Examined Ballast Water Records as per 33 CFR 151.2045. Vessel was not found in compliance with ballast water exchange reporting requirements (no records O/B of any ballast water report). The vessel's masters was provided with educational outreach material and was informed of the required steps on how to provided ballast water reports.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 3 March 2007
Resolution: Received ballast water report.
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 September 2006 Resolved
The 3cm radar was reported ionp prior to the vsl arrival. As per the LOD requirements issued on 10 Sep 05, the vessel will remain in port until proper repairs are conducted and a class report attesting of proper repairs is received and approved by the [name withheld].
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 12 September 2006
Resolution: Received report from class stating that a new radar was installed in the bridge.
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 October 2005 Resolved
Vessel primary radar is inoperable, vessel has requested an LOD for arrival into port of San Juan. Vessel is to have repairs conducted while in port.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 11 October 2005
Resolved 11 October 2005
Resolution: Repairs were made by CRT Communications on 11 Oct 2005. Radar is operational based on technician report.
Pollution Prevention/Response › Prevention Equipment › Garbage Grinder/Comminuter
Issued 12 August 2004 Resolved
REPAIR INCINERATOR AND SUBMIT REPORT FROM CLASS/ FLAG ADMINISTRATOR ATTESTING PROPER REPAIR TO COGNIZANT US MARINE INSPECTOR
Action required: 705 - Other - as specified
Due 13 September 2004
Resolved 1 November 2004
Resolution: Received BV class report stating incinerator is no longer required onboard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.