MAURY USCG vessel records Sign in
← All vessels

BALTIC PATRIOT

BALTIC PATRIOT is a 1992 freight ship. The Coast Guard has recorded 15 inspections since 1992, most recently in December 2023, along with 6 deficiencies — 1 with no resolution recorded — and 2 operational controls, 1 with no removal date recorded.

Records from 1992 to 2023. Most recent: inspection, 15 December 2023.

Built
1992
Last inspected
15 December 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9038488 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
383118
Flag
BAHAMAS, THE
—
Maury page id
psix-383118

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 11 calendar years (1992–2023)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it10402 - Convention (Subpart B), Gross Ton
5265 - Convention (Subpart B), Net Ton
16958 - Displacement, Ton
10621 - Dead Weight, Ton
10402 - Simplified, Gross Ton
5265 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

15 December 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7839367
23 January 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7625401
23 November 2021 PSC A · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7356525
21 November 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7355006
7 February 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6904616
14 February 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6625609
5 January 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6332985
23 January 2012 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4229651
5 July 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4070607
18 October 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3872324
14 October 2010 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3869817
14 January 2010 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3662541
6 January 2005 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2269784
22 December 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1968067
11 December 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 355049

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 December 2023 No resolution recorded
A portable foam applicator unit shall consit of an air-foam nozzle hose. PSCO found hose on the eductor dry rotted, cracked, and sealed by electrical tape.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 December 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 January 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed multiple leaks from No. 6 cylinder on main engine's cooling water.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2023
Resolution: Unit received Class Surveyor Report attesting to satisfactory repair and operational test of the Main Engine cooling water system leak on the No. 6 cylinder liner.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 23 January 2023 Resolved
The Company and the ship must comply with the requirements of the International Safety Management Code. The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the Company. Objective evidence discovered during an expanded ISM exam revealed that the vessel failed to properly inspect, maintain, and report nonconformities relating to vessel main engine leakages in accordance with ship's SMS procedures. In order to account for low cooling water temperatures in No. 6 cylinder, ship's crew changed temperature alarm set points and isolated the cylinder without any documentation or notifications. Corrective action must be taken within three months.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2023
Resolved 26 January 2023
Resolution: Unit received Class Surveyor report stating crew submitted Non-conformity report to Company. Vsl's company also provided doucumentation of crew training on proper reporting and maintenance procedures in accordance with ship's SMS.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 November 2021 Resolved
ICLL(88)1/25(2) GUARD RAILS PF BULWARKS SHALL BE FITTED AROUND ALL EXPOSED DECKS. A STANCHION SUPPORTING THE GUARD RAIL ON THE PORT BOW WAS FOUND BY [name withheld] ALL THE WAY THROUGH.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2021
Resolved 29 November 2021
Resolution: Corrected wasted stanchion support.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 12 January 2010 Resolved
1575 - echosounder - Vessel is required to have an echo depth sounding device. M/V Eagle Bay listed that their echo depth sounder was inoperable on their notice of arrival. Vessel shall repair equipment prior to departure to the satisfaction of the Coast Guard and fax in a copy of the technicians report. 33CFR164.35(h)+(i
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2010
Resolution: Received tech report attesting to the proper working order of the echosounder
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 January 2010 Resolved
1530 - radar - Vessel must have a second marine radar system. M/V EAGLE BAY listed their secondary marine radar as inoperable. Vessel shall repair equipment prior to departure to the satisfaction of the Coast Guard and fax in a copy of the technicians report. 33CFR164.37(a
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2010
Resolution: Received a tech report attesting to the radar working properly.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.