Records from 2017 to 2026. Most recent: inspection, 2 February 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 25
2 February 2026
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8304740
31 January 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8304482
11 April 2025
In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8109998
27 January 2025
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8070294
6 February 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7861249
26 April 2023
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7670975
25 April 2023
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7675121
15 March 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7651291
10 December 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7607138
3 December 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7603600
2 December 2022
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7603196
4 October 2022
PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7571470
15 September 2022
Deficiency Check · Administrative Inspection · In-Service Inspection · ISM Exam · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7559728
19 July 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7511116
18 July 2022
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7506869
14 July 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7506487
19 January 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7381539
4 May 2021
PSC A · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7185526
2 May 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7185494
19 March 2019
ISPS II Exam · NPV Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6645021
7 May 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6408193
29 March 2018
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6380977
22 January 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6341891
18 January 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6340005
5 March 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6099092
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 April 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Upon boarding the vessel, the Pilot discovered the RPM displays on the bridge and in the engine room were inconsistent. Ensure RPM displays are operating properly and the vessel is safe to proceed to the satisfaction of Class and the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2025
Resolved 31 January 2026
Resolution: Sent BV Class Report attesting to repair and RPM display working properly on bridge and in engine room. Report dated 16APR25
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 February 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Auxiliary Engine # 1 has an active cooling water leak due to a crack in the piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2024
Resolved 6 March 2024
Resolution: Vessel submitted class survey verifying repairs.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 15 March 2023
Resolved
Each vessel of 10,000 gross tons or more must have, in addition to the radar system under 164.35(a), a second marine radar system that operates independently of the first.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 March 2023
Resolved 7 April 2023
Resolution: recived confirmation of new display for X-Band radar. New CSSE issued to vessel.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 September 2022
Resolved
In meeting these requirements, the company should ensure that: inspections are held at appropriate intervals; any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. Objective evidence discovered during an expanded ISM exam revealed that the vessel failed to properly inspect, maintain, and report nonconformities relating to fire doors, generator oil leaks, and oily water separator equipment. An external third party SMS audit is required prior to departure from port.
74 SOLAS (2020 cons) IX/3.1
ISM Code 10.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 27 September 2022
Resolved 4 October 2022
Resolution: Vessel completed ISM audit. See documents for details.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 September 2022
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCOs observed significant fuel oil leaks on the number three (3) generator causing a fire hazard.
74 SOLAS (97 cons) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 September 2022
Resolved 4 October 2022
Resolution: Vessel rectified fuel oil leaks to satisfactory of class. See documents.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 September 2022
Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. “A” Class fire doors throughout the engine room are holed, missing latches, and/or have loose door handle accessories.
74 SOLAS (97 cons) II-2/47.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 September 2022
Resolved 4 October 2022
Resolution: Vessel made temporary repairs to fire doors. Condition of Class issued, see documents.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 27 September 2022
Resolved
Except as specified in Paragraph 3 of this Regulation, any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with Paragraph 7 of this Regulation. Vessel’s C/E reported that the OWS three way valve would not fully open and close during testing and is now being overhauled.
MARPOL I/14.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 September 2022
Resolved 4 October 2022
Resolution: Condition of class issued to make permananet repairs, see documents.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 September 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported loss of anchor and significant hull damage sustained during heavy weather.
74 SOLAS (2020 cons) I/11(a)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2022
Resolved 8 December 2022
Resolution: Recieved Class Report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 July 2022
Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. PSCO observed gaskets missing or damaged in several door frames.
74 SOLAS (2001) II-2 / 47.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 October 2022
Resolution: Door frames fixed by crew to satisfaction of class.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 July 2022
Resolved
Any required fire detection system shall be capable of immediate operation at all times. PSCO observed a plastic bag covering a smoke detector.
74 SOLAS (1997) II-2 / 12.1.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 18 July 2022
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 18 July 2022
Resolved
Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. PSCO observed boxes blocking a hose station near the boiler.
74 SOLAS (1997) II-2 / 21
Action required: 10 - Deficiency Rectified
Resolved 18 July 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 May 2021
Resolved
Door fitted in boundary bulkheads in machinery spaces of Category A shall be reasonable gas tight and self closing. PSCOs found multiple class "A" fire door closing mechanisms inoperable with broken hardware, preventing both opening and proper closure. Degrading the structural fire protection of the Category A-60 spaces as indicated on the fire control plan.
74 SOLAS (1997) II-2/47.1
Code 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2021
Resolved 5 May 2021
Resolution: Received a report of survey. A COC to make permanent repairs was given for the item to have all doors repaired according to approved specifications.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 May 2021
Resolved
Every ship shall be provided with fire main complying as applicable with the requirement of this regulation. PSCOs found substantial deterioration to the fire main with multiple temporary repairs made to the piping, significantly reducing the systems integrity.
74 SOLAS (1997) II-2/4.1
Code 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2021
Resolved 5 May 2021
Resolution: Received a report of survey. Temp. repairs made to firemain and tested under 10 bars. A COC to make permanent repairs issued.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 May 2021
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and ensure that inspections are held at appropriate intervals, any non-conformities are reported, appropriate corrective action taken, and records of these activities, PSCO's noted several deficiencies related to firefighting systems, structural protection, lifesaving equipment and the lack of required reporting to company, Flag and Class,which objectively demonstrates non-compliance with relevant conventions, calling into question the adequacy and implementation of the vessel's SMS under the ISM code. An external audit is required to be conducted by the Flag or RO within 30 days to determine the ship is operating IAW the ISM code. Provide a copy of the completed audit report to USCG prior to departure.
74 SOLAS(20) Xl-l/4.1
ISM 10.1
17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2021
Resolved 6 May 2021
Resolution: IMS report of findings submitted to CG.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 May 2021
Resolved
Two means of escape shall be provided from each machinery space of category A, in the lower space, the steel door shall be capable of being operated from each side to provide access to a safe escape route. PSCO's found exit door located in electricians workshop blocked with boxes and stored ship parts. Upon clearing exit path, it was discovered that door mechanism does not properly operate, preventing access to emergency escape just outside of compartment. Additionally, escape breathing device in engine room found empty.
74 SOLAS 97 cons. ll-2/45.3
17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2021
Resolved 5 May 2021
Resolution: Received a report of survey. All obstructions were removed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 4 May 2021
Resolved
The machinery shall be so installed and intended to reduce to a minimum any danger to person on board with due regard to moving parts. PSCO's observed #2 M/E seawater cooling pump missing guard in way of electric motor shaft.
74 SOLAS 97 cons. ll-1/26.1
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 5 May 2021
Resolution: Received a report of survey. M/E #2 seawater cooling pump was placed back in place.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 4 May 2021
Resolved
Plans and booklets shall be kept up to date, any alteration being recorded thereon as soon as practicable. Class "A" self closing fire door leading to maneuvering and switchboard room is not reflected on the fire control plan being displayed.
74 SOLAS 97 cons. ll-2/20.1
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2021
Resolution: Received a report of survey. A COC was given to get all approved plans on board.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 4 May 2021
Resolved
The opening below the lowest course of the guard rails shall not exceed 230mm. While conducting deck walk, PSCO discovered missing bottom guard rail.
ILLC 1966/25.3
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2021
Resolution: Received a report of survey. A temporary chain was put in place and a COC was given to make permanent repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2021
Resolved
The associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Hydraulic value operator for the #2 M/E sea water cooling discharge is inoperable and has been removed, preventing the opening and closure of value.
74 SOLAS 97 cons. ll-1/26.1
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 5 May 2021
Resolution: Received a report of survey. Hydraulic valve controller on #2 M/E missing. A temporary handle was put in place and a COC was given to make permanent repairs.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 19 March 2019
Resolved
Crew members failed to test equipment properly IAW the ships proceedures of the engineering spaces heat detectors.74SOLAS(14)IX/3, ISM Code 10.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2019
Resolved 1 April 2019
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 29 March 2018
Resolved
0615 - The condition of the ship & it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea. PSCO observed under-inflated rescue boat & deck material that was rotted. This caused a distortion of the shape of the rescue boat. 74SOLAS(14)I/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2018
Resolved 7 May 2018
Resolution: Provdided class attestation to rectifying deficiency. See attached documents.
Construction/Loadline › Markings › Load Line Mark
Issued 5 March 2017
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed load line mark painted same white color as the hull, not the required contrasting black.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 March 2017
Resolved 11 April 2017
Resolution: Received class survey