MAURY USCG vessel records Sign in
← All vessels

ADVENTURE OF THE SEAS

ADVENTURE OF THE SEAS is a 2001 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 2001, most recently in April 2026, along with 41 deficiencies and 2 operational controls.

Records from 2001 to 2026. Most recent: inspection, 16 April 2026.

Built
2001
Last inspected
16 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9167227 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
BAHAMAS, THE
—
Maury page id
psix-38353

Inspections, by type

…with no type recorded18
Years with a record 24 calendar years (2001–2026)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it11912 - Dead Weight, Ton
67539 - Displacement, Ton
108644 - Convention (Subpart B), Net Ton
138193 - Convention (Subpart B), Gross Ton
138193 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 80

16 April 2026 PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8350724
16 October 2025 PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8254139
18 April 2025 COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8111415
19 October 2024 COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8021003
4 April 2024 PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7889824
14 October 2023 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7805557
25 March 2023 PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7655247
23 December 2022 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7612619
27 October 2022 COC-CVE Annual · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7583003
17 October 2022 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7578593
26 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7459097
2 May 2022 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7442491
29 April 2022 COC-CVE Quarterly
Type not classified · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7439074
6 December 2021 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7361836
5 November 2021 Ballast Water Examination · COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7344730
21 May 2021 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7202536
28 December 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7116901
3 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935059
18 February 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6912925
3 November 2019 COC-CVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6846189
22 August 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6791700
3 May 2019 ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6676345
6 February 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6621035
10 November 2018 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6578512
19 August 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6559351
12 August 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6616031
9 July 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6584754
4 June 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6433658
31 May 2018 COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6430200
16 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6415699
15 May 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6419580
17 April 2018 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6397483
11 November 2017 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6301800
13 May 2017 ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6143185
14 November 2016 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6004906
3 September 2016 MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5991032
14 May 2016 Ballast Water Examination · COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5872451
14 November 2015 ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5761836
24 March 2014 NPV Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4822016
22 March 2014 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4820946
22 March 2014 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4827903
15 March 2014 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4847985
10 March 2014 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4813532
12 January 2012 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4223766
12 December 2010 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3909163
6 March 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3693960
4 May 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3468517
11 April 2009 MARPOL Annex I Examination · MARPOL Annex V Examination · COC-CVE Quarterly · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3449046
18 October 2008 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3346723
26 April 2008 COC-CVE Quarterly
Type not classified · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3193990
19 January 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3134116
20 October 2007 ISPS III Exam · Ballast Water Examination · COC-CVE Annual · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3083220
14 April 2007 COC-CVE Quarterly
Type not classified · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2909203
17 February 2007 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2874404
17 February 2007 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2874444
21 October 2006 COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2805119
9 July 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2706540
9 July 2006 ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2706653
9 July 2006 ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2734719
24 April 2006 COC-CVE Quarterly
Type not classified · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2543446
24 October 2005 MARPOL Annex V Examination · MARPOL Annex I Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2520793
23 April 2005 COC-CVE Quarterly
Type not classified · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2316391
13 February 2005 Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2291436
24 October 2004 Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2227153
22 October 2004 COC-CVE Annual
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2226139
21 June 2004 ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2106123
18 June 2004 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2102889
6 June 2004 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2101413
24 May 2004 Damage Survey
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2076549
3 May 2004 COC-CVE Quarterly
Type not classified · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2056202
3 December 2003 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1958015
27 October 2003 Certificate of Compliance
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1936097
13 May 2003 Quarterly Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1792583
28 October 2002 MARPOL Annex I Examination · Control Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1697598
13 May 2002 Quarterly Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1611414
12 May 2002 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1615616
6 November 2001 Control Verification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1075742
5 November 2001 Type not recorded
No type recorded · GROUP BOSTON · USCG Northeast District (CGD-NE) · Activity 1496408
5 November 2001 Type not recorded
No type recorded · GROUP BOSTON · USCG Northeast District (CGD-NE) · Activity 1610867
19 October 2001 Type not recorded
No type recorded · Activities Europe · Activity 1376781

Deficiency record · 41

11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 October 2025 Resolved
11131 Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Life boat commanders and second commanders on lifeboats number 5, 7, 11,17, and 23 could not demonstrate ability to utilize or identify the emergency tiller, bilge pump or starting of the engine. 74 SOLAS 20 III/19.2.1 16ac
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2025
Resolved 31 October 2025
Resolution: Vessel submitted satisfactory class report and training records attesting to the training conducted for the lifeboat commanders and second commanders.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2025 Resolved
09209 Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Electrical outlet in the theater was found hanging by live electrical wires. 74 SOLAS 04 II-1/40.1.3 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 October 2025
Resolved 17 October 2025
Resolution: Electrical outlet was corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2025 Resolved
07199 In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. No fuel oil leaks shall be situated where spillage or leakage therefore can constitute a hazard by falling on heated surfaces. PSCO observed oil soaked lagging on both fuel oil seperator's filter casing. 74 SOLAS 97 II-2/15.2.4 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 October 2025
Resolved 17 October 2025
Resolution: lagging was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 October 2025 Resolved
07105 Fire doors in main vertical zone bulkheads and stairway enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. PSCO observed fire doors FD 10.3.12 and FD 8.7.03 not properly latching upon closure. 74 SOLAS 97 II-2/30.4.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 October 2025
Resolved 17 October 2025
Resolution: Fire doors were fixed and tested to ensure proper closure.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 April 2025 Resolved
07120 - Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of space at least one of which shall five access to a stairway forming a vertical escape. The instrument storage room located within the orchestra pit which does not have any direct means of escape was found with a makeshift office making it into a room within a room with no audible alarms installed and no direct passage for escape routes. 74 SOLAS 97 II-2/28.1.2 - 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 April 2025
Resolved 18 April 2025
Resolution: Office equipment, chairs and computers were removed from the space.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 April 2025 Resolved
11129 - Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Lifeboat #20 was found inoperable due to failure to start. 74 SOLAS 97 III/19.2 - 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 April 2025
Resolved 18 April 2025
Resolution: Vessel was worked on by crew and witnessed 3 starts to ensure it was properly working. Vessel engineer said it was due to worm linkage in throttle.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 April 2025 Resolved
07120 - In addition to the emergency lighting, the means of escape, including stairways and exits, shall be marked by lighting of photoluminescent strip indicators placed not more than 0.3m above the deck at all points of the escape route including angles and intersections. The marking must enable passengers to identify all the routes of escape and readily identify escape exits. Escape lighting was found not operational in the Johnny Rockets passageway near fire door 12.7.01. 74 SOLAS 97 II-2/28.1.10 - 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 April 2025
Resolved 18 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 October 2024 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures, designed to re-open upon contacting an object in its path shall re-open sufficiently to allow a clear passage of at least 0.75 m but no more than 1 m. PSCO observed fire door number 1.20 in the incinerator room not re-open after engaging the safety bar. 74SOLAS01 II-2/30.4.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 October 2024
Resolved 19 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 October 2024 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed that the rudder on LB# 6 did not move during steering test.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 October 2024
Resolved 19 October 2024
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 12 April 2024 Resolved
Code 04110: Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Commanders and/or second commanders on life boats 2, 4, and 8 were found to be lacking sufficient knowledge on life boat emergency duties to include actions to be taken in the event of fire and dewatering. 74 Solas 20 III/19.2.1 Action 10c
Action required: 10 - Deficiency Rectified
Resolved 12 April 2024
Resolution: Corrected prior to MI departure.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2023 Resolved
All waste-recepticles shall be constructed of non-combustible material with no openings in the sides of bottom. PSCO observed multiple plastic waste-recepticles labeled for and containing combustible material. 74 SOLAS 91 11-2/18.5
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2023
Resolved 3 April 2023
Resolution: Received class report attesting to the vessel and DNV verifying that all spaces are now in compliance and no combustible waste recepticles are being used inappropriately.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 March 2023 Resolved
Below bulkhead deck, two means of escape at least one of which shall be independent of watertight doors, shall be provided from each watertight compartment. PSCO observed furniture in passageway outside firedoor 1303, boxes outside of electric room 0823b, a thumb latch in the locked position in the pinnacle lounge and an exit sign with an inoperable bulb above fire door 8501, all obstructing means of escape. 74 SOLAS 97 11-2/28.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 March 2023
Resolved 25 March 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 March 2023 Resolved
Hinged fire doors, which are normally kept open, shall be capable of self-closing. Fire door 0701 was observed to not latch. 74 SOLAS 01 11-2/41.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 March 2023
Resolved 25 March 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 October 2022 Resolved
Watertight doors TT01 and TT02 required to sound for a minimum of 5 seconds prior to initiating movement, started to move simultaneous to alarm being sounded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2022
Resolved 2 December 2022
Resolution: DNV surveyor "PSC Code #02101 WTD TT01 and TT02 alarm -> repaired and satisfactory retested. Alarm is sounded 5 sec. before the doors start to move."
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 October 2022 Resolved
Access to the balcony area above bridge was marked as part of an escape route leaving the sauna and sauna showers, however once on the balcony all doors were locked from the inside and no access to outside stairwell from balcony. As a temporary solution, the vessel removed the locks on the doors for the sauna, sauna shower, and gym spaces as well as updated signage for escape route from exterior side of balcony. Fire control plan indicated the doors to the balcony as the secondary means of escape for the sauna and sauna showers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2022
Resolved 2 December 2022
Resolution: DNV Surveyor "PSC Code #07120 Emergency escape from sauna and sauna shower -> rectified, the sliding door is fitted with emergency operation button and the exit/directional arrows signs are fitted for proper guidance."
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 April 2022 Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space. PSCO observed the door in one of the two means of escape from the gym was found not functional and would not open. 74 SOLAS II-2/13.3.2.2
Action required: 10 - Deficiency Rectified
Resolved 29 April 2022
Resolution: Vessel maintenance department fixed door to operate correctly.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 November 2021 Resolved
THE MINIMUM FOR INTEGRITY OF ALL BULKHEADS AND DECKS SHALL BE AS PRESCRIBIED IN TABLES 26.1 TO 26.4. OBERSVED MISSING INSULATION FOR "A-60" FIRE BOUNDARY OF BULKHEAD IN PORT BUNKER STATION. SOLAS 97 II-2/26 40A
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 December 2021
Resolution: Attended vessel. Vessel reinstalled insulation, cleared by RO prior to USCG arrival onboard.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 November 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Resolved 5 November 2021
Resolution: Fire door was re-calibrated and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 November 2019 Resolved
Each exhaust duct shall be fitted with a grease trap readily removable for cleaning. Exhaust duct from galley on deck 4 is oozing grease on deck 13.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 November 2019
Resolved 13 November 2019
Resolution: Ducts clean and sat class report provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 November 2019 Resolved
A fixed fire detection systems shall be so installed and arranged as to provide smoke detection in accommodation spaces. 15 smoke detectors within loop near children's area Adventure Zone are inop.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 November 2019
Resolved 13 November 2019
Resolution: Fault corrected, sat class report provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2019 Resolved
WHENEVER AN ACCIDENT OCCURS ABOARD A SHIP OR A DEFECT IS DETECTED, EITHER OF WHICH AFFECTS THE SAFETY OF THE SHIP, THE MASTER OR OWNER OF THE SHIP SHALL REPORT TO THE RECOGNIZED ORGANIZATION, WHO SHALL CAUSE INVESTIGATIONS TO BE INITIATED. VESSEL REPORTED A CASUALTY TO DG3 DUE TO TACHOMETER FAILURE DURING DEPARTURE FROM PORT EVERGLADES ON 02FEB19. VESSEL IS REQUIRED TO SUBMIT CAUSAL ANALYSIS AND CLASS REPORT ATTESTING TO REPAIRS. 74 SOLAS (14 CONS) I/11 (C)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 February 2019
Resolved 11 February 2019
Resolution: Received class report. All sat.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Sulphur oxides
Issued 6 February 2019 Resolved
WHEN SHIPS ARE OPERATING WITHIN AN EMISSION CONTROL AREA, THE SULPHUR CONTENT OF FUEL OIL USED ON BOARD SHIPS SHALL NOT EXCEED 0.10% M/M ON AND AFTER 1 JANUARY 2015. VESSEL SELF-FREPORTED SWITCHING TO DG4 FOLLOWING LOSS OF DG3 FOR PURPOSES OF SAFE NAVIGATION. DG4 WAS RUNNING ON HFO WITH NOT SCRUBBERS. MARPOL VI/14.4.3
Action required: 10 - Deficiency Rectified
Due 6 February 2019
Resolved 6 February 2019
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 November 2017 Resolved
The construction of all doors shall provide resistance to fire as well the passage of smoke. the PSCO found the lock set had been removed on fire screen door 11.606 leaving an opening completely through the door. SOLAS (97)II-2/30.2
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2017
Resolved 11 November 2017
Resolution: Deficiency was rectified on the spot.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 11 November 2017 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be ready for immediate use. The PSCO found the hydraulic steering on #2 Lifeboat was not operational. SOLAS (14) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2017
Resolved 11 November 2017
Resolution: Deficiency was corrected on the spot.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 November 2017 Resolved
A door designed to re-open upon contacting an object in its path shall re-open. The PSCO found sliding fire screen door 10.5.16 would not re-open on contacting an object. SOLAS (97) II-2/30.4.2
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2017
Resolved 11 November 2017
Resolution: Deficiency was corrected on the spot.
Construction/Loadline › Structures › Door
Issued 14 November 2016 Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them, when closed, shall provide resistance to fire as well to the passage of smoke and flame. PSCO found the hose ports on FD3.7.06 and FD4.7.10 would not close. FD4.7.10 closed out of sequence preventing the door from fully closing. 74SOLAS(97) II-2/20.2
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 14 November 2016
Resolution: corrected on the spot.
Fire Fighting › Means of Escape › Blocked
Issued 14 November 2016 Resolved
above the bulkhead deckthere shall be at least two means of escape from each main vertical zone or similarly restricted space. PSCO found in the main dining room, fire screen door 3.6.01 was blocked by three (03) service carts. 74SOLAS(97)II-2/28.12
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 14 November 2016
Resolution: corrected on the spot.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 14 November 2016 Resolved
All waste receptacles shall be constructed of non-cobustible material. PSCO found plastic waste receptacles being used for papaer and plastic in locations: Pantry FD3.2.05, and crew pantry 3801 74SOLAS(97) II-2/18.5
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 14 November 2016
Resolution: corrected on the spot.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 14 November 2015 Resolved
Waste Receplacles shall be constructed of non-combustable materials with no openings in the sides or bottomw. PSCO discovered combustible waste receptacles inside wiiden covers on the pool deck, in Cloud Nine lounge area, and in the Diamond Club. 74 SOLAS (1997) II-2/18.5 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 November 2015
Resolved 14 November 2015
Resolution: Vessels crew replaced waste receptacles.
Fire Fighting › Means of Escape › Blocked
Issued 14 November 2015 Resolved
Means of escape shall be kept in order to ensure their required performance. Egress routes were blocked in the following locations: table and shelf outside Sauna office on deck 12(primary egress), chair and locked door blocking secondary egress from cloud 9 lounge, merchandise displays in way of primary egress route leading fwd from port side accomodations to stairtower 3c on deck 3. 74 SOLAS (20
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 November 2015
Resolved 14 November 2015
Resolution: Vessels crew removed the items that were blocking the egress routes.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 14 November 2015 Resolved
PSCO found non-approved flammable liquid storage lockers in the following spaces: electrical workshop on deck 1(cat 13), carpenters workshow on deck 1(cat 13), upholstery workshop on deck 1(cat 13), tech storeroom fwd of ice skating rink on deck 2 (cat 13), medical facility(cat 7), and several other category 7 and 13 spaces throughout the vessel. 74 SOLAS (1997) II-2/26.1 50ac
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2015
Resolved 7 January 2016
Resolution: Vessel provided documentation to the resolution of the deficiency.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 24 March 2014 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Excessive amounts of combustible material stored in the Alaska and Caribbean conference rooms & the Pizzeria dining room - Code 0750 - SOLAS 97 CH II-2 Reg 26.2.2
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2014
Resolved 24 March 2014
Resolution: Condition of Class received- It was agreed to have additional fire watch for the Alaskan & Caribbean Conference Rooms when not occupied by personnel. It was further agreed to not allow additional items to be stored in the subject rooms.
Lifesaving › Rescue Boat › Rudder/Tiller/Steering
Issued 17 February 2007 Resolved
Make proper repairs to steering wedge for port side rescue boat.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2007
Resolved 17 February 2007
Engineering › Gas Turbine (propulsion-reduction gear) › Seal
Issued 18 June 2004 Resolved
Vessel to effect permanent repairs to the STBD Azipod and submit Flag/Class report to the USCG prior to departing.
Action required: 705 - Other - as specified
Due 19 June 2004
Resolved 19 June 2004
Resolution: def cleared
Engineering › Electric Propulsion System
Issued 24 May 2004 Resolved
Provide Flag state/Classification Sociey Report attesting to the repairs and staus of the STBD Azipod.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2004
Resolved 24 May 2004
Resolution: Received DNV class report attesting to vessel satisfactory operation without stbd azipod operational. Vessel equipped with redundant propulsion system as per class cert.
Engineering › Electric Propulsion System
Issued 24 May 2004 Resolved
Provide technicians report attesting to the status of, and repair of the STBD Azipod.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2004
Resolved 28 May 2004
Resolution: Received service tech report attesting to all repairs and satisfactory operation of stbd azipod.
Fire Fighting › Fixed Fire Detection System
Issued 26 October 2003 Resolved
ENSURE PROPER OPERATION OF SMOKE DETECTORS NUMBERS: EO175, BO448, BO455 PRIOR TO 02NOV2003. LEGACY COMPONENT DESC: Smoke Detectors
Due 2 November 2003
Resolved 6 November 2003
Resolution: def corrected
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 26 October 2003 Resolved
REMOVE ALL FURNITURE OBSTRUCTIONS FROM EMERGENCY EXIT AREA IN THE DECK/LOBBY BAR. FIRE DOOR NUMBER 4.5.04. LEGACY COMPONENT DESC: Recreation Space
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2003
Resolved 27 November 2003
Resolution: VERIFED REMOVAL WHILE ONBOARD VESSEL
Deck/Cargo › Cargo Stowage
Issued 26 October 2003 Resolved
REMOVE ALL STORED ITEMS FROM UNDER THE MAIN STAIRCASE, DECK 3 DINING ROOM AND PERMANANTLY SEAL THE ACCESS HATCH TO PREVENT UNAUTHORIZED STORAGE.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2003
Resolved 6 November 2003
Resolution: def corrected
Fire Fighting › Fixed Fire Detection System
Issued 26 October 2003 Resolved
PROVIDE SMOKE DETECTORS VICE HEAT DETECTORS IN ALL REFRIDGERATED STORAGE SPACES ABOVE 5 DEGRESS CELCIUS TO THE SATISFACTION OF CLASS SURVEYOR. LEGACY COMPONENT DESC: Heat Detectors
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 November 2003
Resolved 3 December 2003
Unknown
Issued 19 October 2001 Resolved
COMPLETE THE OUSTANDING WORKLIST ITEMS FOUND IN MINS MI01034531
Condition: Unknown
Due 19 October 2001
Resolved 19 October 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.