Records from 1993 to 2005. Most recent: inspection, 10 June 2005.
Inspection history · 37
10 June 2005
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2845130
30 November 2004
Construction Oversight · Examination of Repairs · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2250954
3 June 2004
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2098625
9 April 2004
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2049629
4 April 2003
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1771234
20 November 2002
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1731535
11 March 2002
COI Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1492508
1 May 2001
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376573
13 March 2001
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1061479
6 June 2000
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1050711
24 April 2000
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1048797
17 March 2000
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1451528
9 August 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1111753
26 April 1999
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360949
19 April 1999
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 793967
17 March 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1406466
22 July 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1375463
19 June 1998
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1126912
6 May 1998
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1447831
20 March 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416471
7 November 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383368
11 October 1996
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380691
23 August 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1089886
19 June 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363702
19 April 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357570
22 March 1996
COI Inspection · Drydock Extension · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1387960
4 December 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1459201
29 July 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 88005
19 May 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1181644
19 April 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1412795
18 November 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1444918
3 November 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 707151
23 September 1994
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396185
12 September 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 372070
22 April 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353558
20 August 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1464473
12 April 1993
Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1146549
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 30 November 2004
No resolution recorded
Provide adequate mounting of propane tanks.
Due 21 January 2005 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 June 2004
Resolved
Fabricate or procure a battery box for the port battery bank.
Action required: 705 - Other - as specified
Due 20 June 2004
Resolved 22 December 2004
Stability › Watertight Integrity
Issued 14 March 2002
Resolved
Install an acceptable manufactured port light for the existing port & stbd port lights or remove the existing port lights and make satisfactory hull repairs in way of the old port lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 2 January 2003
Resolution: Port lights removed.
Lifesaving › Lifebuoys
Issued 11 March 2002
Resolved
Provide a new life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2002
Resolved 14 March 2002
Stability › Watertight Integrity
Issued 11 March 2002
Resolved
Install a hinged dead cover for the port & stbd port lights per 46 CFR 171.119.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2002
Resolved 12 August 2002
Stability › Watertight Integrity
Issued 11 March 2002
Resolved
Repair the securing devices for the forward & aft main deck watertight hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2002
Resolved 12 August 2002
Fire Fighting
Issued 17 March 1999
Resolved
Properly service BII portable fire extinguishers.
Condition: Unknown
Due 17 April 1999
Resolved 17 June 1999
Documentation
Issued 17 March 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Construction/Loadline
Issued 17 March 1999
Resolved
Properly label bilge running alarms and high level indicators at control console.
Condition: Unknown
Due 17 April 1999
Resolved 17 June 1999
Lifesaving
Issued 17 March 1999
Resolved
Provide proof 6 red and 6 orange distress signals.
Condition: Unknown
Due 17 April 1999
Resolved 17 June 1999
Lifesaving
Issued 22 July 1998
Resolved
Emergency checkoff list faded and difficult to read. Replace faded emergency checkoff list iaw 46CFR185.510.
Condition: Unknown
Due 22 August 1998
Resolved 18 August 1998
Construction/Loadline
Issued 6 May 1998
Resolved
Remove and renew all wet rotted internal structural hull members in port hull sink area, first bay aft of the ladder. Known rotted members are:_x001C_ top inboard longitudinal stringer; bottom outboard longitudinal stringer;_x001C_ inboard vertical transverse frame supporting aft end of ladder.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Engineering
Issued 22 March 1996
Resolved
Provide suitable means to secure the air supply to the engine room in the event of a fire.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Electrical
Issued 22 March 1996
Resolved
In lieu of wire nuts, install UL approved pressure connectors for the VHF-FM radio electrical supply.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Engineering
Issued 22 March 1996
Resolved
Prove proper operation of the engine room exhaust ventilation blower.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 22 March 1996
Resolved
Post PFD placards in accordance with 46 CFR 185.516.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Electrical
Issued 22 March 1996
Resolved
Provide portable lights in accordance with 46 CFR 183.430.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Electrical
Issued 22 March 1996
Resolved
Prove operation of the compass light in accordance with 46 CFR 184.402.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Navigation
Issued 22 March 1996
Resolved
Post a radio emergency broadcast placard in accordance with 46 CFR 184.506.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 22 March 1996
Resolved
Conduct and log crew training in accordance with 46 CFR 185.420.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Accommodation/Occupational Safety
Issued 22 March 1996
Resolved
Make operable from both sides, emergency escape hatches in forward and aft compartments.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Engineering
Issued 22 March 1996
Resolved
Make fuel tank space vapor tight from passenger accommodation area, and provide adequate ventilation for the fuel tank space.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Construction/Loadline
Issued 22 March 1996
Resolved
Provide dead covers for each opening port light located below the weather deck.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Construction/Loadline
Issued 22 March 1996
Resolved
Crop and renew soft wood in bilges of port and stbd head and sink compartments; restore to original strength.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Engineering
Issued 22 March 1996
Resolved
In lieu PVC, properly install approved metallic pipe and/or flexible hose in the main engine exhaust system.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Engineering
Issued 22 March 1996
Resolved
Install a remote operated emergency fuel shutoff valve located directly at the fuel tank connection for the port and stbd fuel tanks. A total of two emergency fuel shutoff valves shall be provided, one for each tank.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Construction/Loadline
Issued 22 March 1996
Resolved
Renew damaged rubber boot for steering tiller arm penetrating the transom.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Electrical
Issued 22 March 1996
Resolved
Replace missing light lens covers on overhead lights in forward and aft compartments.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Engineering
Issued 22 March 1996
Resolved
Properly insulate main engine exhaust piping up to the point of water injection.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Construction/Loadline
Issued 22 March 1996
Resolved
Crop and renew soft wood in port aft step decking and hand rail stanchion area; restore to original strength.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Navigation
Issued 22 March 1996
Resolved
Provide tide and current tables.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 22 March 1996
Resolved
Properly install retroreflective tape on the life ring buoy in accordance with 46 CFR 185.604(i).
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 22 March 1996
Resolved
Provide a suitable container for the distress signals in accordance with _x001C_ 46 CFR 185.614.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Construction/Loadline
Issued 22 March 1996
Resolved
Properly label the watertight hatches in accordance with 46 CFR 185.610.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Engineering
Issued 22 March 1996
Resolved
Permanently repair the salt water leak on the main engine heat exchanger.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Engineering
Issued 22 March 1996
Resolved
Renew in kind, damaged supply and exhaust ventilation ducting for the engine room; properly secure the through hull fittings.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Construction/Loadline
Issued 22 March 1996
Resolved
Provide a hand portable bilge/fire pump with suction strainer and suitable suction and discharge hoses.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Engineering
Issued 22 March 1996
Resolved
Double hose clamp fuel supply flexible hose connections.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Engineering
Issued 22 March 1996
Resolved
Replace missing bolts in the aft port engine mount for the main diesel engine.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 22 March 1996
Resolved
Remove excess flammables from the aft center compartment.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Construction/Loadline
Issued 22 March 1996
Resolved
Provide an indicator light in addition to the audible alarm for the engine room high level bilge alarm at the operating station.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 22 March 1996
Resolved
Provide passenger count lists in accordance with 46 CFR 185.504.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 22 March 1996
Resolved
Conduct passenger safety orientation in accordance with 46 CFR 185.506.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 22 March 1996
Resolved
Conduct and log abandon ship and man overboard drills and training in accordance with 46 CFR 185.520.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Accommodation/Occupational Safety
Issued 22 March 1996
Resolved
Properly label the emergency escape hatches in accordance with 46 CFR 185.606.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Fire Fighting
Issued 22 March 1996
Resolved
Conduct and log fire fighting drills and training in accordance with 46 CFR185.524.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 22 March 1996
Resolved
Properly label all lifesaving equipment in accordance with 46 CFR 185.604.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Lifesaving
Issued 22 March 1996
Resolved
Provide six serviceable smoke flares onboard prior to operating with passengers.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Fire Fighting
Issued 22 March 1996
Resolved
Provide covered metal trash can for the below deck passenger accommodation area.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Accommodation/Occupational Safety
Issued 22 March 1996
Resolved
Provide locking device and properly label sewage overboard valves.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Documentation
Issued 4 December 1995
Resolved
Post original COI.
Condition: Unknown
Due 4 December 1995
Resolved 4 December 1995
Documentation
Issued 4 December 1995
Resolved
Provide evidence vessel is constructed of fire retardant resins.
Condition: Unknown
Due 4 December 1995
Resolved 4 December 1995
Documentation
Issued 4 December 1995
Resolved
Prior to carrying passengers for hire, provide masters license.
Condition: Unknown
Due 4 December 1995
Resolved 4 December 1995
Documentation
Issued 4 December 1995
Resolved
Provide evidence of compliance with Chemical Testing Regulations: a)Modify random selection method to be a valid scientific method, b)Provide an education, training and Employee Assistance Program.
Condition: Unknown
Due 4 December 1995
Resolved 4 December 1995
Lifesaving
Issued 4 December 1995
Resolved
Prove proper operation of the waterlight. Vessel is restricted to daylightoperations until corrected.
Condition: Unknown
Due 4 December 1995
Resolved 4 December 1995
Construction/Loadline
Issued 19 April 1995
Resolved
PROVIDE AND PROVE PROPER OPERATION OF ELECTRIC BILGE PUMPING SYSTEM, IN COMPLIANCE WITH NEW SUBCHAPTER T REGULATIONS. THIS TO INCLUDE SUBMITTING PLANS FOR APPROVAL, PRIOR TO INSTALLATION. ALL WORK TO BE COMPLETED TO THESATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Engineering
Issued 23 September 1994
Resolved
REPAIR AS PER MARINE SURVEYOR INSTRUCTION, CRACK IN STAINLESS STEEL MAST BOOT STEP; FWD MAST, PORT SIDE, AFT LOWER CORNER. FAX MARINE SURVEYOR REPORT OF REPAIR TO USCG MSO INSPECTION DEPT.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Accommodation/Occupational Safety
Issued 12 September 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 September 1994
Resolved 3 November 1994
Accommodation/Occupational Safety
Issued 12 September 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 September 1994
Resolved 3 November 1994
Documentation
Issued 12 April 1993
Resolved
PROVIDE A COPY OF THE FOLLOWING PLANS FOR APPROVAL BY MSO HONOLULU: (1) SAIL PLAN, (2) DECK PLAN, (3) ONE-LINE ELECTRIC SCHEMATIC, (4) MIDSHIP SECTION, AND (5) INBOARD PROFILE. PROVIDE FOR REVIEW NO LATER THAN 15JUN93.
Condition: Unknown
Due 15 June 1993
Resolved 26 May 1993
Navigation
Issued 12 April 1993
Resolved
RENEW THE GREEN LENS IN THE STARBOARD NAVIGATION LIGHT. DEMONSTRATE COMPLIANCE IN THE PRESENCE OF A CG MARINE INSPECTOR NO LATER THAN 01MAY93.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Lifesaving
Issued 12 April 1993
Resolved
CONDUCT UNDERWAY EMERGENCY DRILLS IN THE PRESENCE OF A MARINE INSPECTOR NOTLATER THAN 18JUNE93.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Lifesaving
Issued 12 April 1993
Resolved
POST EMERGENCY CHEK-OFF PROCEDURES IN A VISIBLE LOCATION. DEMONSTRATE COMPLIANCE IN THE PRESENCE OF A CG MARINE INSPECTOR NO LATER THAN 19APR93.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993
Documentation
Issued 12 April 1993
Resolved
PROVIDE EVIDENCE OF A DRUG TESTING PROGRAM TO A CG MARINE INSPECTOR NO LATER THAN 03MAY93.
Condition: Unknown
Due 12 April 1993
Resolved 12 April 1993