MAURY USCG vessel records Sign in
← All vessels

RUNAWAY BAY

RUNAWAY BAY is a 1992 freight ship. The Coast Guard has recorded 49 inspections since 1992, most recently in February 2025, along with 25 deficiencies and 3 operational controls.

Records from 1992 to 2025. Most recent: inspection, 18 February 2025.

Built
1992
Last inspected
18 February 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9019640 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
383713
Flag
BAHAMAS, THE
—
Maury page id
psix-383713

Inspections, by type

…with no type recorded21
Years with a record 28 calendar years (1992–2025)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it9070 - Convention (Subpart B), Gross Ton
5838 - Convention (Subpart B), Net Ton
11579 - Dead Weight, Ton
16745 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 49

18 February 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8080569
15 February 2025 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8080022
6 February 2024 PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7857704
2 November 2023 Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7819522
7 September 2023 PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7782075
13 June 2022 PSC B · Deficiency Check
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7476024
8 June 2022 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7463201
15 November 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7350997
7 September 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7306026
23 February 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7144649
6 November 2020 Administrative Inspection · Deficiency Check · COE-Administrative
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7089778
11 August 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7029763
3 June 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6692464
2 June 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6701373
13 February 2019 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6625027
25 October 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6564258
15 September 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6264603
18 December 2015 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5784238
23 August 2014 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4962652
27 October 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3877074
18 January 2010 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3665569
28 January 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3401650
8 January 2009 ISPS III Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3390604
7 July 2008 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3261045
6 July 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3255801
2 July 2008 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3255052
22 October 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3078513
5 August 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2736480
27 July 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2726251
29 June 2005 ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2407467
11 January 2005 Ballast Water Examination · ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2272589
9 March 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2021039
15 February 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1745114
16 January 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1478271
1 March 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 425937
6 March 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 413335
2 September 1997 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 407382
20 February 1997 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 455797
18 November 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 397531
8 October 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 396109
31 July 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 460816
15 March 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 491368
13 March 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 376043
22 February 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 646482
16 February 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 528246
26 May 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 690670
24 May 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 475266
7 January 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 363634
29 December 1992 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 355338

Deficiency record · 25

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 September 2023 Resolved
IN SPACES WHERE PENETRATION OF OIL PRODUCTS IS POSSIBLE, THE SURFACE OF INSULATION SHALL BE IMPERVIOUS TO OIL OR OIL VAPOURS. LAGGING ON THE PORT SIDE, AFT OF THE MAIN ENGINE WAS FOUND TO BE SATURATED WITH OIL. 74 SOLAS (97) II-2/18.6 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 September 2023
Resolved 7 September 2023
Resolution: IMPROPER LAGGING WAS REPLACED TO THE SATISFACTION OF THE COAST GUARD.
01 - Certificates & Documentation › 011 - Ships Certificates › International Sewage Pollution Prevention Cert.
Issued 7 September 2023 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO FOUND AN UNAPPROVED REPAIR TO THE SEWAGE TREATMENT SYSTEM. A METAL COMPONENT ON THE TOP OF THE SYSTEM WAS REPLACED WITH A PVC PIPE, NOT ALLOWING FOR A SECURE SEAL TO THE SYSTEM. 74 SOLAS (04) I/11A 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 October 2023
Resolved 2 November 2023
Resolution: Received RO/Class (Bureau Veritas) report attesting to the satisfactory repair of subject sewage treatment plant piping with original steel construction and verification of proper operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Continuous synopsis record
Issued 8 June 2022 Resolved
01123-The administration shall issue, as soon as is practically possible but not later than three months from date of change updated version of the continuous synopsis record. PSCO observed vessels CSR was not updated within three months of change of classification society. 74SOLAS(20)XI-1/5.4.2, 50a,c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2022
Resolved 13 June 2022
Resolution: Provided New CSR
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 June 2022 Resolved
07126-The arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed approximately 300 gallons of oil mixture accumulated in the bilge underneath the main engine. 74SOLAS(97)II-2/15.2, 15a,c
Action required: 15 - Rectify deficiencies by next port
Resolved 16 June 2022
Resolution: Class attended vessel and issued condition of class. Oily water cleared from bilge.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 June 2022 Resolved
07120-This shelter shall be of steel, insulated, to the satisfaction of the administration, and be provided with a self closing steel door. PSCO observed escape route boundary door was difficult to open and after opening did not self close. 74SOLAS(97)II-2/45.3.1, 17a,c
Action required: 10 - Deficiency Rectified
Resolved 8 June 2022
Resolution: Door fixed prior to exam completion.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 September 2021 Resolved
Means shall be provided to control leaks of flammable liquids to prevent the ignition of combustible materials. PSCO observed generator #2 and #3 had oil pooling beneath. 74SOLAS(14) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 November 2021
Resolution: Provided class report clearing deficinency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fir to proceed to sea without danger to the ship or persons on board. PSCO observed ejector cooling water pump, sw service pump, reefer pump, and fire & gs pump leaking 30 to 80 drips of water per minute. 74SOLAS(14) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 November 2021
Resolution: Provided class report clearing deficinency.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 7 September 2021 Resolved
Vessel must maintain a ballast water management plan that has been specifically developed for the vessel that will allow those responsible for the plan to understand and follow it. Vessel does not have a plan addressing the removal of organisms from the hull. Excessive growth was found on ships hull. PSCO provided ship with sample Bio Fouling management plan and RES.MEPC.207(62). 33 CFR 151.2050 (f) 33 CFR 151.2050 (g)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 November 2021
Resolution: Provided class report clearing deficinency.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 11 August 2020 Resolved
The condition of the ship shall be maintained to conform with the present regulations. Fuel oil leak was discovered on emergency generator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2020
Resolved 12 November 2020
Resolution: Master provided class report attesting to the correction. See documents for class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 August 2020 Resolved
The condition of the ship shall be maintained to conform with the present regulations. Sea water pump for service generator was leaking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2020
Resolved 12 November 2020
Resolution: Master provided class report attesting to the correction. See documents for class report.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 11 August 2020 Resolved
Machinery boilers and other pressure vessels, associated piping systems and fittings shall be so installed and protected as to reduce ro a minimum any danger to persons on baord. Hot surface of exhaust on generator was missing insulation. Crew immediately insulated surface.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 August 2020
Resolved 11 August 2020
Resolution: Crew replaced missing insulation.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 June 2019 Resolved
Cylinders must always be secured and, when not in use, must be stowed in a rack in upright position. Cylinders were unsecured, stored on top of each other, and not in an upright position causing damage near the valve. 46CFR147.60 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 June 2019
Resolved 3 June 2019
Resolution: Vessel added a shelf and stored all cylinders in an upright position.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2018 Resolved
Machinery piping shall be of a design and constrution adequate for the service for which they are intended and so be installed and proteced as to reduce to a minimum any danger to persons. Oil purifier piping was discovered to be supported by temprary bracing (metal wire) to prevent vibration while the vessel is underway.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 November 2018
Resolved 13 February 2019
Resolution: Received Class report attesting to repairs.
Engineering › Steering Gear System › Follow-up Assembly
Issued 18 January 2010 Resolved
1499 - Other- All steering gear components shall be of a sound and reliable construction to the satisfaction of the administration. On Notice of Arrival. the vessel reported that the #1 auto-pilot steering system was only working in non-follow up mode. Vessel is to have class attest to the operation of the #1 steering system in all modes. SOLAS 74 (2004 cons ed.) CH II-1 REG 29.2.1
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 January 2010
Resolved 20 January 2010
Resolution: Port State Control Officers received class report attesting to the proper operation of both the steering controls. Vessel has operational follow up and non follow up modes of steering in the #1 steering system.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 8 January 2009 Resolved
Lifeboats are required to be equipped by SOLAS and the LSA Code with food rations kept in airtight packaging and by SOLAS ship safety equipment certificate to accommodate a total of 25 people. Out of 50 rations, between both lifeboats, 28 rations were no longer airtight. Vessel must replace rations to satisfaction of Coast Guard prior to depart.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2009
Resolution: Received invoice from agent for the purchase of 28 food rations and their arrival to the vessel.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 January 2009 Resolved
There is a soft patch on the supply raw water line for the AUX Generators. There as a bucket hanging under the patch. Class needs to attest to either a permanent repair to the piping or replace the section with a new section. This creates both a slip and bodily hazard for the crew in the overhead of the lower deck aft of the engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 February 2009
Resolved 14 August 2009
Resolution: Received class report confirming permanent repair to sea water pipeline to auxiliary generators.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 July 2006 Resolved
Fixed CO2 system is past due for servicing. Arrangements have been made to complete servicing at next port. Service to be provided to the satisfaction of the administration.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 5 August 2006
Resolution: Received fax from Unitor that all systems have been serviced and are in proper working order
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 July 2006 Resolved
Portable fire extinguishers are past due for servicing. Arrangements have been made for servicing at next port. Servicing is to be attested to the satisfaction of the administration.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 5 August 2006
Resolution: Received fax stating that all portable extingushers have been serviced and are in good working order
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 July 2006 Resolved
Permanent repairs are to be made to the various non-vital sea water supply piping systems found holed and repaired w/ soft patches. Repairs to be attested to the satisfaction of class surveyor.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 October 2007
Resolution: Received class report attesting to repairs made on the sea water supply piping systems.
Engineering
Issued 6 March 1998 Resolved
A deficiency of 33 CFR 156.170 in that the vessel did not have a current bunker line pressure test onboard._x001C_ _x001C_ PROVIDE PROOF OF LINE TEST PRIOR TO BUNKERING IN U.S.
Condition: Unknown
Due 6 March 1998
Resolved 9 March 1998
Lifesaving
Issued 8 October 1996 Resolved
THE VESSEL'S CREW WAS UNABLE TO SATISFACTORILY COMPLETE A FIRE DRILL AND SHOW PROFICIENCY IN THE OPERATION OF THE VESSEL'S FIRE FIGHTING EQUIPMENT. MSD SANTA BARBARA CONDUCTED A SECOND FIRE DRILL ON 09OCT96 AND THE CREW DIDA GOOD JOB. CORRECTED 09OCT96.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Accommodation/Occupational Safety
Issued 8 October 1996 Resolved
VESSEL HAD RAT POSION/BUG SPRAY, AND A CREWMAN LIVING IN THE HOSPITAL SPACE. ADVISED MASTER AND HE CORRECTED IT WHILE WE WERE ON BOARD.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Navigation
Issued 13 March 1995 Resolved
ST. JOHNS River Approach chart #11490 was missing correction 02/95. Latest Notice to Mariners(NTM) on board was 51/94. NTM to be provided & correction made to chart prior to departure from Jacksonville.
Condition: Unknown
Due 13 March 1995
Resolved 14 March 1995
Navigation
Issued 13 March 1995 Resolved
ST. JOHNS RIVER chart #11491 was missing corrections 02,05/95. Latest Notice to Mariners(NTM) on board was 51/94. Provide NTM and make corrections to chart prior to departure from Jacksonville.
Condition: Unknown
Due 13 March 1995
Resolved 14 March 1995
Documentation
Issued 29 December 1992 Resolved
Vessel's oil transfer procedures were missing a list of each product transferred including: generic or chemical name, cargo information, and applicability of transfer procedures as required by 33CFR155.750(a)(1)(i- iii)
Condition: Unknown
Due 30 December 1992
Resolved 30 December 1992

Ownership record