Inspection record

Last inspected 6 August 2026
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

383715
Flag
UNITED STATES
Maury page id
psix-383715

Documentation record

Tonnage as PSIX records it2823 - Regulatory (Subpart C or D), Gross Ton
2785 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 44 inspections, each with its date, unit and type; 68 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 44

6 August 2026 Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8456891
10 June 2026 Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8397771
7 January 2026 COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8292402
7 July 2025 COI Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8178321
30 January 2025 Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8075128
23 October 2024 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8023660
17 October 2024 Administrative Inspection · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8020252
17 October 2024 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8020600
11 June 2024 COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7933400
1 December 2023 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7840663
13 July 2023 COI Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7739494
8 June 2023 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7709752
18 May 2023 Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7674603
16 March 2023 Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7652134
2 February 2023 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7630977
14 December 2022 Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7609278
8 August 2022 Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7528410
15 June 2022 COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7482750
22 March 2022 Administrative Inspection · Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7413531
30 December 2021 Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7415341
9 September 2021 Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7415337
8 June 2021 COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7219833
5 April 2021 Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7170309
12 March 2021 Examination of Repairs · Drydock Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7155273
28 May 2020 Administrative Inspection · COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6986625
22 October 2019 In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6841504
24 July 2019 Internal Structural Exam · Administrative Inspection · Re-Inspection · Examination of Repairs
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6760846
20 March 2019 Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6645792
13 February 2019 Examination of Repairs
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6625359
14 March 2018 COI Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6362422
24 January 2018 Administrative Inspection · Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6343156
8 November 2017 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6303656
17 October 2017 Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6289576
6 October 2017 Re-Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6288955
1 August 2017 Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6289556
14 July 2017 Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6212151
6 March 2017 Plan Review (Other than "T") · Administrative Inspection · COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6099966
18 January 2017 Administrative Inspection · Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6073084
31 August 2016 Re-Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5990245
22 June 2016 Re-Inspection · In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5917653
9 March 2016 COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5830740
7 March 2016 Construction Oversight
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5828752
2 March 2016 Drydock Exam · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5826387
27 January 2016 Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5804631

Deficiency record · 68

01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 10 June 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2026
Resolution: Master had MMC onboard
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 June 2026 Resolved
46 CFR 71.250 - At each annual inspection, the inspector must ensure that the following tests and inspections of fire detection and extinguishing equipment have been conducted: All portable fire extinguishers and semi-portable fire extinguishing systems must be maintained in accordance with NFPA 10, chapter 7; Carbon Dioxide Weigh cylinders; All fire detection and extinguishing systems, all piping controls, valves, and alarms must be checked to ascertain that the system is in operating condition. Annual servicing/inspection not completed (Exp May 2025)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2026
Resolution: Extinguishers and fixed system were inspected by Johnson Controls
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 10 June 2026 Resolved
46 CFR 113.40-10 - Each rudder angle indicator system must have a transmitter at the rudder head that is actuated by movement of the rudder with the angular movements of the rudder transmitted to a remote indicator or indicators. However, the indicator may be physically located on a control console, such as an integrated bridge system, if it is readily visible by the helmsman at the steering stand. Rudder angle indicators in engineering and in wheelhouse do not match and are inaccurate relative to machinery equipment.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2026
Resolution: replaced circuit cards and indicators
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 June 2026 Resolved
46 CFR 78.15-1 Subdivision bulkheads. (a) All watertight doors in subdivision bulkheads shall be kept closed during navigation except when necessarily opened for working of the vessel, and in such cases they shall always be ready to be immediately closed. Discovered the door had been removed; prior to the re-inspection. Forward WTD of MDE space is being refabricated. Prior to Movement, prove proper watertightness of WTD.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2026
Resolution: NTD's welds. Conducted chalk test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 February 2026 Resolved
Scope. The inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that it is in satisfactory condition. Port ship’s service diesel generator is inoperable and requires overhaul for repair. Rectify within 120 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2026
Resolved 6 August 2026
Resolution: Engine overhauled.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 24 February 2026 Resolved
Flexible electric cord and cables. No flexible cord may be used except: (1) As allowed under Sections 400.10 and 400.12 of NFPA 70. Flexible cords, flexible cables, flexible cord sets and power supply cords shall not be used as a substitute for the fixed wiring of a structure. Flexible cord is being used to power new freezer in main deck galley. Current power cable is too short and cannot reach dedicated receptacle. Replace power cable or move dedicated receptacle closer to the appliance.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2026
Resolution: Installed longer cable on freezer.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 February 2026 Resolved
Temporary emergency loads. The following emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source: At least one light in each space where a person may be maintaining, repairing, or operating equipment, stowing or drawing stores or equipment, or transiting, such as… galleys. 01 Deck Galley emergency lighting lamp is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2026
Resolution: replaced lamp
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2026 Resolved
Accessibility and spacing. The design and arrangement of electric apparatus must afford accessibility to each part as needed to facilitate proper inspection, adjustment, maintenance, or replacement. 01 Deck Galley 120v panel door is damaged, secured with duct tape. Repair panel door to facilitate proper use.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2026
Resolution: replaced panel latch
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 21 July 2025 Resolved
All automatically or remotely controlled or monitored vital systems addressed by part 62 of this sub chapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Test procedures must be submitted to the Coast Guard for approval. Persons designated by the owner of the vessel must conduct all tests and the Design Verification and Periodic Safety tests must be witnessed by the Coast Guard. Design Verification Test Procedures (DVTPs) have been approved by MSC but have not yet been witnessed by the Coast Guard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2025
Resolved 9 February 2026
Resolution: Witnessed DVTP's for Engine Alarm Monitoring System.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 July 2025 Resolved
Electric installations on vessels must ensure:Maintenance of system integrity through compliance with the applicable system requirements (IEEE, NEC, IEC, etc.) to which plan review has been approved. Anchor light receptacle junction-box is inoperable. Anchor light is currently receiving power via extension cord. Repair/replace primary anchor light receptacle as designed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2025
Resolved 11 March 2026
Resolution: Replace anchor light outlet
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 July 2025 Resolved
The fire detection and alarm system must control and monitor input signals for all connected detectors and manual pull stations or call points. Smoke detector in storage room on main deck has been removed. Re-install new detector when received to clear fire control panel fault. Conduct operational test upon re-installation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2025
Resolved 24 February 2026
Resolution: Smoke detector in storage room has been replaced and programmed to correspond with location. Fire alarm panel fault record is clear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2025 Resolved
The following plans must be submitted to the Coast Guard for approval in accordance with §§ 50.20-5 and 50.20-10 of this chapter: (1) A general arrangement plan of control and monitoring equipment, control locations, and the systems served. (2) Control and monitoring console, panel, and enclosure layouts. (3) Schematic or logic diagrams including functional relationships, a written description of operation, and sequences of events for all modes of operation. (4) A description of control or monitoring system connections to non-vital systems. (5) A description of programmable features. (6) A description of built-in test features and diagnostics. (7) Design Verification and Periodic Safety test procedures described in subpart 61.40 of this subchapter. (8) Control system normal and emergency operating instructions. A new engineering alarm monitoring system was installed at the Engineering Control Center without prior Coast Guard approval. Submit plans to the Marine Safety Center for review within 60 days. After plans have been reviewed/approved by the Marine Safety Center, the Design Verification Testing Procedures and Periodic Safety Testing procedures shall be witnessed by the cognizant OCMI for final approval.
Action required: 705 - Other - as specified
Due 31 July 2025
Resolved 22 July 2025
Resolution: Fire Control Plan complete and approved.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 31 July 2023 Resolved
Witnessed operational steering test underway, all sat except center flanking rudder inoperable due to a leaking hydraulic cylinder. Parts ordered.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 June 2024
Resolution: Cylinder was replaced. Witnessed operational test.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 17 July 2023 Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and ventilators. Thirteen (13) inoperable fire dampers; listed in an email sent to vessel Captain and company rep. Prior to Movement, Prove proper operation of thirteen (13) dampers in the presence of attending Marine Inspector. 46 CFR 72.15-15(a), 46 CFR 72.15-20
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 June 2024
Resolution: Tested all dampers
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 July 2023 Resolved
Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of producing a signal or tone distinct from any other audible signal on the vessel. Five (05) Alarm Bells are inoperable. All Four (04) on 02 Deck and one (01) on 01 Deck STBD side Frame 68. Prior to Movement, Prove proper operation of all five (05) alarm bells in the presence of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: Witnessed satisfactory operational test of general emergency alarms.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 July 2023 Resolved
The hull, structural bulkheads, decks, and deckhouses shall be constructed of steel or other equivalent metal construction of appropriate scantlings. 03 Deck-Port Side Electrical Room has Four (04) holes in forward bulkhead and STBD Side Electrical Room has Two (02) holes in outboard bulkhead. Prior to Movement, Prove proper structural integrity/fire protection of both bulkheads in the presence of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: All holes have been filled with fire cock.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 July 2023 Resolved
In general, connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. All connecting devices must be suitable for copper stranded conductors. Each outlet or junction box must have a cover unless a fixture canopy, switch cover, receptacle cover, or other cover is used. 03 Deck-Port Side Electrical Room loose wire exposed and cover not secured on junction box. Prior to Movement, Prove in the presence of attending Marine Inspector the wire and cover are secured. 46 CFR 111.60-17(a) and 46 CFR 111.81-1(c)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: Wire and box have been secured.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 July 2023 Resolved
There shall be at least two means of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed. At least one of these two means of escape shall be independent of watertight doors. Main Deck – Port Side Engine Room Door 44 restricted with a cart and refrigerator in passageway. Chiller Flat – Forward of Engine Room Port Side, Escape Scuttle does not dog down. Bow Thruster Space – Escape scuttle does not open. Prior to Movement, Prove proper operation of all three (03) means of escape in the presence of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: Witnessed proper operation of all three (03) means of escape.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 July 2023 Resolved
Operational readiness. Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. 01 Deck – Port Side Aft, Two (02) Fifty (50) person IBAs are not stowed properly with HRUs. Prior to Movement, Prove proper stowage arrangement in the presence of attending Marine Inspector.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: Witnessed proper stowage of IBAs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 July 2023 Resolved
(c)Illumination of passenger and crew spaces. (2) Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space. Port and Starboard wing storage areas forward of main engine room have no emergency lighting. Prove proper operation of emergency lighting in the presence of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2023
Resolution: Witnessed operational test of lighting.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 July 2023 Resolved
d) Navigation lights. Each navigation light must meet the following: (1) Meet the technical details of the applicable navigation rules. Aft Mast light (Not Under Command) inoperable. Prior to Movement, Prove proper operation in the presence of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: Witnessed operational test of nav lights.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 June 2023 Resolved
The inspection shall include a complete inspections of structure including the outside of the vessels bottom. Vessels hull plating suffered several large, sharp insets at the bow rake. Additionally, several frames and gussets in way of the damaged hull plating are deflected. Crop out and renew damaged areas to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 11 June 2024
Resolution: Repair was overseen by MSU Houma in Dec 2023 during A# 7840663.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 May 2023 Resolved
(a) Approved fire detection and alarm systems must be installed on the following vessels as set forth in subpart 76.27 of this part: (2) Any vessel of more than 150 feet (45.72 meters) in length having sleeping accommodations for passengers; Installed fire detection system is displaying a trouble alarm for the main deck galley and stores (zone 12). Conducted operational test of the system to include (zone 12). Tested smoke detectors in zone 12, all sat. Vessel was unable to test heat detectors in zone 12. Galley is currently not being used. Prior to operating any heat sources in zone 12, identify trouble alarm(s), replace faulty component(s), and test to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 July 2023
Resolution: Witnessed operational test of all heat and smoke detectors in zone 12, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2023 No resolution recorded
All automatic auxiliary boilers must be tested and inspected in accordance with this subpart and subpart 61.05 of this part. Crew has no records for testing of auxiliary boiler. Boiler is required to be tested during next quarterly re-inspection in April 2023. Provide boiler information to Marine inspector prior to next vessel quarterly inspection to determine boiler inspection requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 February 2023 Resolved
At each inspection the inspector shall conduct test and inspections of all hull equipment including all subdivision bulkheads to determine that their watertight integrity has not been impaired. Various sections of framing, girders, and bulkheads were found severely wasted from vessels watertight bulkhead, frame 33, to the aft machine shop bulkhead, frame 61. The attached documents of the vessels structural design drawings indicate all the areas that were found. Crop/renew to good metal indicated areas of concern to the satisfaction of an attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 February 2023
Resolved 27 February 2023
Resolution: Inspected all structural repairs,sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2023 Resolved
Fixed fire extinguishing systems must be checked as noted in table 71.25-20 (a)(2). In addition all parts of the fixed fire extinguishing system must be examined for general condition. Gaylord hood damper inoperable. Make repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 17 March 2023
Resolution: Third party cleaned and tested
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2023 Resolved
Where hose ports are fitted, they shall be cut in the lower corner of the door on the side opposite the hinge so that if the hose is passed through the doorway when the door is open, it may be closed over the hose. The cut for the hose port should be approximately 6 inches square. A hinged or pivoted steel or equivalent metal cover shall be fitted in the cut, equipped with a bullet catch or similar method of fastening which will permit easy and automatic operation of the hinged cover. Hose ports inoperable. Repair to requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 27 February 2023
Resolution: Inspected fire door hose ports, sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 February 2023 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspections. Scupper pipe on starboard fwd. fuel void cut and unapproved repair installed. Make permanent repair to the satisfaction of an attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 16 March 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2023 Resolved
Fire hazards shall be minimized insofar as is practicable. Excessive oil in the engine room bilge, steering room and starboard aft fuel oil tank supply valve leaking. Remove excess oil to the satisfaction of an attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 15 February 2023
Resolved 14 February 2023
Resolution: 10 c
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 February 2023 Resolved
All subdivision bulkheads shall be examined to determine that their watertight integrity has not been impaired. Clean bilges and provide access to bow thruster room, engine room and steering room/aft void.
Action required: 10 - Deficiency Rectified
Due 15 February 2023
Resolved 14 February 2023
Resolution: 10 C.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 January 2023 Resolved
At each inspection the inspector shall conduct test and inspections of all hull equipment including all subdivision bulkheads to determine that their watertight integrity has not been impaired. Inspectors discovered severe corrosion to hull plating, internal framing, watertight subdivision bulkheads and fuel tank bulkheads. Also discovered multiple deformed gussets adjacent to fuel tank. Wasted fuel tank plating must be renewed. Vessel is required to be dry-docked and made available for US Coast Guard inspection to determine condition of suspect hull plating and internal framing. Vessel must undergo external hull examination and internal structural examination. The MISSISSIPPI must travel light boat from Memphis, TN to James Marine Inc. in Wickliffe, KY to undergo a US Coast Guard external hull examination and internal structural examination. Prior to departure the forward fuel tank must be stripped.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 February 2023
Resolution: Hull examination and ISE completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2023 Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valve. All three SSDG and port MDE fuel supply remote operated valves were inoperable. Replace or service valves so they can be operated remotely.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2023
Resolution: tested all fuel oil shutoff valves with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 January 2023 Resolved
Fixed fire extinguishing systems must be checked as noted in table 71.25-20 (a)(2). In addition all parts of the fixed fire extinguishing system must be examined for general condition. There was a cracked hose from a CO2 bottle to the discharge piping manifold on the engine room fixed CO2 system. Hose shall be replaced by authorized servicing provider.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2023
Resolution: replaced 3 hoses
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2023 Resolved
The inspection shall include inspection structure, boilers, pressure vessels, machinery and equipment. Piping shall be inspected to insure satisfactory condition. There was fuel leak on EDG fuel fill piping.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2023
Resolution: Inspected fuel system on EDG, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 January 2023 Resolved
The bulkhead deck must be water tight. Gaskets on all escape scuttles on the installed in the bulkhead deck (main deck)are deteriorated and no longer water tight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2023
Resolution: replaced gaskets and chalk tested
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 January 2023 Resolved
The inspection shall include machinery and equipment to insure equipment is in satisfactory condition and fit for the service in which it is intended. One of the two MSD discharge pumps has been removed from service but has not been locked or tagged out properly. Pump isolation valves are not locked closed posing the potential for sewage leak. Circuit breaker is not locked out and pump wires have exposed conductors posing potential electrical shock hazard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2023
Resolution: Inspected MSD pumps, no electrical hazard present. Circuit tagged out.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 January 2023 Resolved
Portable conatainers use to store flammable and combustible liquids must meet requirements of UL 30 or UL 1313. Portable containers must be stored in a paint locker or open location designated by the master. Multiple portable gasoline conatainers were found stored underneath the stbd rescue boat. Containers were not secured for sea. Several containers were missing caps or were not UL approved. Remove unserviceable or unapproved containers. Store containers in paint locker or suitable open location where they can be secured for sea.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2023
Resolution: Removed all unapproved gasoline containers from vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2023 Resolved
The grab line on lifebuoys shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum synthetic material having a minimum breaking strength of 1,350 pounds. The grab lines on the lifebuoys are deteriorated. Replace the lifebuoy grab lines
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 16 March 2023
Resolution: The lifebuoy grab lines were replaced with new grab lines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 January 2023 Resolved
Power operated steering systems must have limit switches for cutting off power to the steering gear before the rudder reaches the stops. Stearing trunnions are hitting rudder stops. Adjust limit switches to proper settings.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 16 March 2023
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 January 2023 Resolved
In all ventilation systems manually operated dampers or other suitable means shall be provided outside the space served for shutting off the passage of air in event of fire. Ventilation cover gaskets are worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 16 March 2023
Resolution: New gaskets were placed around the ventilation covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 January 2023 Resolved
The inspection shall include inspection of machinery to insure it is in satisfactory condition and fit for service. EDG starter timer is malfuctioning causing the starter bendix to engage engine flywheel while engine is running. Engineers have to unwire starter after engine has started and operating to prevent malfunction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 31 July 2023
Resolution: Witnessed operation of EDG timer.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 18 January 2023 Resolved
Before the vessel leaves port and at all times during the voyage each lifesaving appliance must be in working order and ready for immediate use. Port rescue boat davit has significant leak on hydraulic cylinder. Vessel is equipped with two rescue boats and may operate with only one rescue boat. Port rescue boat davit shall not be used until hydraulic cylinder is repaired or replaced. The number of passengers is reduced from 113 to 107 for a total of 142 persons allowed to accommodate the rescue of the total persons allowed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 February 2023
Resolved 25 June 2024
Resolution: Davit was repaired. Witnessed weight test.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 January 2023 Resolved
Each liferaft must be arranged for float-free launching. The arrangement must ensure that the liferaft, when released and inflated, are not dragged under by the sinking vessel. The 03 inflatable buoyant apparatuses were not arranged for float-free launching. Vessel crew made repairs on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 January 2023
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 18 July 2022 Resolved
Generator prime movers must shut down automatically upon loss of lubricating oil pressure. Starboard SSDG did not shut down upon loss of lube oil pressure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2022
Resolved 8 August 2022
Resolution: Caterpillar technician replaced oil sensor sending unit. Provided copy of service report
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 18 July 2022 Resolved
If vessels certificate of inspection is renewed annually, the setting of the safety relief valve on pressure vessels must be checked annually. Vessel could not provide relief valve setting documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2022
Resolved 18 January 2023
Resolution: Vessel installed new pressure relief valves
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 July 2022 Resolved
Doors in main vertical zone bulkheads shall be of the self-closing type. Several fire doors would not self close. Rectify deficiency within 90 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2022
Resolved 17 March 2023
Resolution: doors adjusted and tested
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 July 2022 Resolved
The fire detection and alarm system must be so arranged and installed that the presence of a fire in any protected space will be automatically registered visually and audibly on the fire control panel. The visible notice must indicate the zone in which the alarm originated. Several fire detectors did not correlate to proper location on fire alarm panel. Rectify deficiency within 90 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 October 2022
Resolved 8 August 2022
Resolution: Problem was caused by 2 pull stations not being reset. When conducting smoke test, alarm panel was showing trouble alarm in zone were pull station was not reset. Conducted spot check of 25 smoke detectors, all sat.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 18 July 2022 Resolved
Fire and Control plan must be approved by cognizant [name withheld] fire control plan has not been stamped "approved". Verify contents of plan and submit to OCMI for approval.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2022
Resolved 31 July 2025
Resolution: Fire control plan signed and marked approved by SLMR OCMI.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 18 July 2022 Resolved
Drills must be conducted in the presence of a marine inspector. Full crew compliment was not present at time of inspection to conduct drills. Conduct drills in the presence of CG Marine Inspector within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 8 August 2022
Resolution: Conducted satisfactory fire and man overboard drill
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 March 2022 Resolved
As an alternative to the survival craft requirements of § 199.201(b), vessels may carry inflatable buoyant apparatus having an aggregate capacity sufficient to accommodate 67 percent of the total number of persons on board, minus the capacities of any lifeboats, rescue boats and life-rafts carried on board. These inflatable buoyant apparatus must meet the arrangement requirements of § 199.630 (d)(1) through (d)(3). The number of persons accommodated in an inflatable buoyant apparatus may not exceed 150% of its rated capacity. Two (02) Inflatable Buoyant Apparatus' are on-board having a total capacity for 60 persons; not meeting 67% of total number of persons on-board. Passenger Count has been reduced to 74.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Three (03) Inflatable Buoyant Apparatuses are on board having a total capacity of 90 persons.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 6 October 2017 Resolved
3 of the 20 flexible loop hoses connecting the activation heads to the E/R system manifold were threaded on to the activation head and not tightened. They were loose enough to unscrew by hand. One of the 20 flexible loops was only placed against the threads, but not screwed onto the threads at all and came off the fitting upon placing a hand on it. This would potentially caused a major failure of the E/R fixed CO2 system, had there been an E/R fire and the system was activated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2017
Resolution: Ship's engineers were immediately notified of the situation. Ship's force tightened all loose flexible loops and placed the system back in service.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 6 October 2017 Resolved
Battery operated e-light in MSD space did not operate when test button was pressed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2017
Resolved 6 October 2017
Resolution: Batteries were replaced on the spot by ship's force.
Construction/Loadline › Structures › Door
Issued 6 October 2017 Resolved
3 water tight doors below the main deck required adjustment. When doors were closed, up to 4 of the 6 dogs were loose and not engaged with the pads on the frame. At least one hand wheel was loose.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2017
Resolved 6 October 2017
Resolution: Ship's force completed adjustment of all water tight doors on the spot.
Electrical › Electric Generation Source (emergency) › Generator
Issued 1 August 2017 Resolved
Emergency generator windings are destroyed. Temporary EDG is in place and hard wired into emergency circuit panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 17 October 2017
Resolution: Vessel replaced emergency generator with new. Witnessed test and satisfactory shift of power through emegency switch board. All SAT.
Construction/Loadline › Hull › Weld
Issued 14 July 2017 Resolved
Found pin hole leak in center shaft tube, a welded doubler patch is allowed for temp repairs until permanent repairs can be made upon dry dock availability.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 10 July 2018
Lifesaving › Lifejacket/PFD (Type I) › Size
Issued 7 March 2017 Resolved
Provide 16 Type I child size life jackets as per COI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 24 January 2018
Resolution: Vessel has appropriate lifejacket count in servicable condition.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 6 March 2017 Resolved
Watertight door indicators must be operable on the pilot house
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 24 January 2018
Resolution: Wiring for display panel was disconnected. Technician reconnected and tested satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 6 March 2017 Resolved
Starboard engine failed to shut down during emergency procedures due to faulty valve air intake.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 8 March 2017
Resolution: MI witnessed satisfactory overspeed shutdown after install of new valve.
Operations/Management › Drills/Instruction › Fire
Issued 18 January 2017 Resolved
Machinery space fire drill was conducted, observed multiple deficencies during drill. Crew must conduct machinery space fire drill to satisfaction of the [name withheld].
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2017
Resolved 6 March 2017
Resolution: Conducted satisfactory E/R fire drill.
Communications › Alarms/Indicators › General Alarm
Issued 18 January 2017 Resolved
02 deck general alarm is inoperable, verify GE, bell & lights, PTCP.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2017
Resolved 6 March 2017
Communications › Visual Communication › Warning Sign (gangway)
Issued 31 August 2016 Resolved
Provide necessary markings for fire and emergency equipment missing throughout the vessel (CO2 alarms, manual alarm boxes, portable fire extinguishers, E-Lights, Etc...)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 24 January 2018
Resolution: Vessel label and marked all emergency equipment IAW IMO standards.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 29 June 2016 Resolved
Prove servicing of IBA's prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 13 July 2016
Resolution: IBAs serviced and returned to the vessel for installation.
Engineering › Electric Propulsion System › Winding
Issued 9 March 2016 Resolved
Prove proper function of the 250 horse power Veth-Jet bow thruster in the presence of an attending USCG marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 22 June 2016
Resolution: Demonstrated proper operation
Communications › Alarms/Indicators › General Alarm
Issued 9 March 2016 Resolved
General alarm in engine room needs a placard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 22 June 2016
Resolution: witnessed installed.
Communications › Alarms/Indicators › General Alarm
Issued 9 March 2016 Resolved
Repair general alarm bell in main control room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 24 March 2016
Resolution: MI witnessed operation.
Communications › Alarms/Indicators › General Alarm
Issued 9 March 2016 Resolved
Repair general alarm bells from frame 50-51.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 24 March 2016
Resolution: MI observed operation. Electrical short caused the inop alarm bells.
Lifesaving › Launching Appliances › Davit
Issued 9 March 2016 Resolved
port and starboard rescue boat davits need annual service.
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 24 March 2016
Resolution: MI witnessed annual light boat weight test and full function test by third party contractor.
Lifesaving › Launching Appliances › Davit
Issued 9 March 2016 Resolved
Prove port side rescue boat limit switch functions properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2016
Resolved 22 June 2016
Resolution: Witnessed proper operation of limit switch.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.