Records from 1993 to 2026. Most recent: inspection, 6 August 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 146
6 August 2026
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8456891
10 June 2026
Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8397771
7 January 2026
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8292402
7 July 2025
COI Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8178321
30 January 2025
Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 8075128
23 October 2024
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8023660
17 October 2024
Administrative Inspection · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8020252
17 October 2024
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8020600
11 June 2024
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7933400
1 December 2023
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7840663
13 July 2023
COI Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7739494
8 June 2023
Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7709752
18 May 2023
Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7674603
16 March 2023
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7652134
2 February 2023
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7630977
14 December 2022
Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7609278
8 August 2022
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7528410
15 June 2022
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7482750
22 March 2022
Administrative Inspection · Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7413531
30 December 2021
Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7415341
9 September 2021
Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7415337
8 June 2021
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7219833
5 April 2021
Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7170309
12 March 2021
Examination of Repairs · Drydock Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7155273
28 May 2020
Administrative Inspection · COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6986625
22 October 2019
In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6841504
24 July 2019
Internal Structural Exam · Administrative Inspection · Re-Inspection · Examination of Repairs
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6760846
20 March 2019
Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6645792
13 February 2019
Examination of Repairs
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6625359
14 March 2018
COI Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6362422
24 January 2018
Administrative Inspection · Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6343156
8 November 2017
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6303656
17 October 2017
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6289576
6 October 2017
Re-Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6288955
1 August 2017
Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6289556
14 July 2017
Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6212151
6 March 2017
Plan Review (Other than "T") · Administrative Inspection · COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6099966
18 January 2017
Administrative Inspection · Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6073084
31 August 2016
Re-Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5990245
22 June 2016
Re-Inspection · In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5917653
9 March 2016
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5830740
7 March 2016
Construction Oversight
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5828752
2 March 2016
Drydock Exam · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5826387
27 January 2016
Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5804631
9 November 2015
Re-Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5760190
4 August 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5205858
25 March 2014
COI Inspection · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4822580
9 July 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4373556
25 June 2012
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4357681
6 June 2012
Re-Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4336089
1 February 2012
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4236367
14 September 2011
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4149179
25 July 2011
Administrative Inspection · Deficiency Check · Periodic Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4095972
24 January 2011
Plan Review (Other than "T")
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3933076
23 March 2010
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3701285
6 May 2009
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3468722
16 March 2009
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3430277
13 January 2009
Administration
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3393463
4 December 2008
Hull Examination · Drydock Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3377122
15 October 2008
Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3345480
17 July 2008
In-Service Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3276740
16 July 2008
Excursion Permit
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3269862
25 June 2008
Deficiency Check · Examination of Repairs
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3247610
3 June 2008
Drydock Extension · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3226032
8 May 2008
Internal Structural Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3202655
24 March 2008
Excursion Permit
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3170559
5 March 2008
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3158743
3 December 2007
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3108625
20 November 2007
In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3103017
12 July 2007
In-Service Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2995420
28 March 2007
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2897695
27 March 2007
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2896045
14 July 2006
Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2712424
6 July 2006
In-Service Inspection · Deficiency Check
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2703711
23 March 2006
COI Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2608033
15 November 2005
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2535041
28 September 2005
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2503211
4 August 2005
Excursion Permit
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2457191
27 July 2005
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2441963
24 May 2005
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2367755
6 April 2005
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2378226
22 March 2005
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2318567
14 December 2004
In-Service Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2259187
7 September 2004
Excursion Permit
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2189298
3 August 2004
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2154867
2 August 2004
Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2153635
12 July 2004
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2130601
20 May 2004
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2073207
5 May 2004
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2059538
14 April 2004
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2044321
6 April 2004
Quarterly Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2039202
15 December 2003
Quarterly Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1964570
3 October 2003
Administrative Inspection
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1920635
26 August 2003
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1888547
25 July 2003
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1895895
8 July 2003
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1841758
7 May 2003
COI Inspection · Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1788961
5 December 2002
Hull Examination · Excursion Permit · Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1715028
16 September 2002
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1676369
2 August 2002
Administrative Inspection
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1655997
30 July 2002
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1654450
24 June 2002
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1636742
22 May 2002
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1619892
26 February 2002
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1492380
27 November 2001
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 773027
6 November 2001
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1076083
30 July 2001
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1069786
16 May 2001
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1412283
27 March 2001
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1063111
20 March 2001
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1397600
22 February 2001
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1059608
7 February 2001
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1059304
28 August 2000
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1451600
20 June 2000
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1051131
17 May 2000
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1444338
24 February 2000
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1403066
1 February 2000
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 814431
2 December 1999
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1441589
9 August 1999
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1413582
13 May 1999
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1462755
1 March 1999
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1402797
22 September 1998
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 801825
14 July 1998
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1390795
28 April 1998
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1426075
14 April 1998
Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1463371
12 February 1998
Drydock Extension
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 776690
8 January 1998
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1422953
4 June 1997
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1450035
5 March 1997
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1431733
27 August 1996
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1396586
20 June 1996
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1400387
19 April 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1081844
7 March 1996
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 884631
12 February 1996
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449902
25 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1403948
30 March 1995
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1145677
24 February 1995
Damage Survey
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1444947
21 September 1994
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367173
14 April 1994
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1014931
23 February 1994
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 853355
27 August 1993
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1135989
19 August 1993
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 843819
8 July 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1153025
18 June 1993
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1154904
1 March 1993
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 837546
25 February 1993
Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1143516
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 10 June 2026
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2026
Resolution: Master had MMC onboard
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 June 2026
Resolved
46 CFR 71.250 - At each annual inspection, the inspector must ensure that the following tests and inspections of fire detection and extinguishing equipment have been conducted: All portable fire extinguishers and semi-portable fire extinguishing systems must be maintained in accordance with NFPA 10, chapter 7; Carbon Dioxide Weigh cylinders; All fire detection and extinguishing systems, all piping controls, valves, and alarms must be checked to ascertain that the system is in operating condition.
Annual servicing/inspection not completed (Exp May 2025)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2026
Resolution: Extinguishers and fixed system were inspected by Johnson Controls
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 10 June 2026
Resolved
46 CFR 113.40-10 - Each rudder angle indicator system must have a transmitter at the rudder head that is actuated by movement of the rudder with the angular movements of the rudder transmitted to a remote indicator or indicators. However, the indicator may be physically located on a control console, such as an integrated bridge system, if it is readily visible by the helmsman at the steering stand.
Rudder angle indicators in engineering and in wheelhouse do not match and are inaccurate relative to machinery equipment.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2026
Resolution: replaced circuit cards and indicators
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 June 2026
Resolved
46 CFR 78.15-1 Subdivision bulkheads.
(a) All watertight doors in subdivision bulkheads shall be kept closed during navigation except when necessarily opened for working of the vessel, and in such cases they shall always be ready to be immediately closed.
Discovered the door had been removed; prior to the re-inspection.
Forward WTD of MDE space is being refabricated.
Prior to Movement, prove proper watertightness of WTD.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2026
Resolution: NTD's welds. Conducted chalk test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 February 2026
Resolved
Scope. The inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that it is in satisfactory condition.
Port ship’s service diesel generator is inoperable and requires overhaul for repair. Rectify within 120 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2026
Resolved 6 August 2026
Resolution: Engine overhauled.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 24 February 2026
Resolved
Flexible electric cord and cables.
No flexible cord may be used except: (1) As allowed under Sections 400.10 and 400.12 of NFPA 70. Flexible cords, flexible cables, flexible cord sets and power supply cords shall not be used as a substitute for the fixed wiring of a structure.
Flexible cord is being used to power new freezer in main deck galley. Current power cable is too short and cannot reach dedicated receptacle. Replace power cable or move dedicated receptacle closer to the appliance.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2026
Resolution: Installed longer cable on freezer.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 February 2026
Resolved
Temporary emergency loads.
The following emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source: At least one light in each space where a person may be maintaining, repairing, or operating equipment, stowing or drawing stores or equipment, or transiting, such as… galleys.
01 Deck Galley emergency lighting lamp is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2026
Resolution: replaced lamp
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2026
Resolved
Accessibility and spacing.
The design and arrangement of electric apparatus must afford accessibility to each part as needed to facilitate proper inspection, adjustment, maintenance, or replacement.
01 Deck Galley 120v panel door is damaged, secured with duct tape. Repair panel door to facilitate proper use.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2026
Resolution: replaced panel latch
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 21 July 2025
Resolved
All automatically or remotely controlled or monitored vital systems addressed by part 62 of this sub chapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Test procedures must be submitted to the Coast Guard for approval.
Persons designated by the owner of the vessel must conduct all tests and the Design Verification and Periodic Safety tests must be witnessed by the Coast Guard.
Design Verification Test Procedures (DVTPs) have been approved by MSC but have not yet been witnessed by the Coast Guard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2025
Resolved 9 February 2026
Resolution: Witnessed DVTP's for Engine Alarm Monitoring System.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 July 2025
Resolved
Electric installations on vessels must ensure:Maintenance of system integrity through compliance with the applicable system requirements (IEEE, NEC, IEC, etc.) to which plan review has been approved.
Anchor light receptacle junction-box is inoperable. Anchor light is currently receiving power via extension cord. Repair/replace primary anchor light receptacle as designed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2025
Resolved 11 March 2026
Resolution: Replace anchor light outlet
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 21 July 2025
Resolved
The fire detection and alarm system must control and monitor input signals for all connected detectors and manual pull stations or call points.
Smoke detector in storage room on main deck has been removed. Re-install new detector when received to clear fire control panel fault. Conduct operational test upon re-installation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2025
Resolved 24 February 2026
Resolution: Smoke detector in storage room has been replaced and programmed to correspond with location. Fire alarm panel fault record is clear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2025
Resolved
The following plans must be submitted to the Coast Guard for approval in accordance with §§ 50.20-5 and 50.20-10 of this chapter:
(1) A general arrangement plan of control and monitoring equipment, control locations, and the systems served.
(2) Control and monitoring console, panel, and enclosure layouts.
(3) Schematic or logic diagrams including functional relationships, a written description of operation, and sequences of events for all modes of operation.
(4) A description of control or monitoring system connections to non-vital systems.
(5) A description of programmable features.
(6) A description of built-in test features and diagnostics.
(7) Design Verification and Periodic Safety test procedures described in subpart 61.40 of this subchapter.
(8) Control system normal and emergency operating instructions.
A new engineering alarm monitoring system was installed at the Engineering Control Center without prior Coast Guard approval. Submit plans to the Marine Safety Center for review within 60 days. After plans have been reviewed/approved by the Marine Safety Center, the Design Verification Testing Procedures and Periodic Safety Testing procedures shall be witnessed by the cognizant OCMI for final approval.
Action required: 705 - Other - as specified
Due 31 July 2025
Resolved 22 July 2025
Resolution: Fire Control Plan complete and approved.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 31 July 2023
Resolved
Witnessed operational steering test underway, all sat except center flanking rudder inoperable due to a leaking hydraulic cylinder. Parts ordered.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 June 2024
Resolution: Cylinder was replaced. Witnessed operational test.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 17 July 2023
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and ventilators.
Thirteen (13) inoperable fire dampers; listed in an email sent to vessel Captain and company rep.
Prior to Movement, Prove proper operation of thirteen (13) dampers in the presence of attending Marine Inspector.
46 CFR 72.15-15(a), 46 CFR 72.15-20
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 June 2024
Resolution: Tested all dampers
08 - Alarms › N/A - No Subsystem › General alarm
Issued 17 July 2023
Resolved
Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of producing a signal or tone distinct from any other audible signal on the vessel.
Five (05) Alarm Bells are inoperable. All Four (04) on 02 Deck and one (01) on 01 Deck STBD side Frame 68.
Prior to Movement, Prove proper operation of all five (05) alarm bells in the presence of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: Witnessed satisfactory operational test of general emergency alarms.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 July 2023
Resolved
The hull, structural bulkheads, decks, and deckhouses shall be constructed of steel or other equivalent metal construction of appropriate scantlings.
03 Deck-Port Side Electrical Room has Four (04) holes in forward bulkhead and STBD Side Electrical Room has Two (02) holes in outboard bulkhead.
Prior to Movement, Prove proper structural integrity/fire protection of both bulkheads in the presence of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: All holes have been filled with fire cock.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 July 2023
Resolved
In general, connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. All connecting devices must be suitable for copper stranded conductors.
Each outlet or junction box must have a cover unless a fixture canopy, switch cover, receptacle cover, or other cover is used.
03 Deck-Port Side Electrical Room loose wire exposed and cover not secured on junction box.
Prior to Movement, Prove in the presence of attending Marine Inspector the wire and cover are secured.
46 CFR 111.60-17(a) and 46 CFR 111.81-1(c)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: Wire and box have been secured.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 July 2023
Resolved
There shall be at least two means of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed. At least one of these two means of escape shall be independent of watertight doors.
Main Deck – Port Side Engine Room Door 44 restricted with a cart and refrigerator in passageway.
Chiller Flat – Forward of Engine Room Port Side, Escape Scuttle does not dog down.
Bow Thruster Space – Escape scuttle does not open.
Prior to Movement, Prove proper operation of all three (03) means of escape in the presence of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: Witnessed proper operation of all three (03) means of escape.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 July 2023
Resolved
Operational readiness. Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use.
01 Deck – Port Side Aft, Two (02) Fifty (50) person IBAs are not stowed properly with HRUs.
Prior to Movement, Prove proper stowage arrangement in the presence of attending Marine Inspector.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: Witnessed proper stowage of IBAs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 July 2023
Resolved
(c)Illumination of passenger and crew spaces.
(2) Sufficient illumination must be provided by the emergency lighting source under emergency conditions to effect damage control procedures and to provide for safe egress from each space.
Port and Starboard wing storage areas forward of main engine room have no emergency lighting.
Prove proper operation of emergency lighting in the presence of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2023
Resolution: Witnessed operational test of lighting.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 July 2023
Resolved
d) Navigation lights. Each navigation light must meet the following:
(1) Meet the technical details of the applicable navigation rules.
Aft Mast light (Not Under Command) inoperable.
Prior to Movement, Prove proper operation in the presence of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 July 2023
Resolution: Witnessed operational test of nav lights.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 June 2023
Resolved
The inspection shall include a complete inspections of structure including the outside of the vessels bottom. Vessels hull plating suffered several large, sharp insets at the bow rake. Additionally, several frames and gussets in way of the damaged hull plating are deflected. Crop out and renew damaged areas to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 11 June 2024
Resolution: Repair was overseen by MSU Houma in Dec 2023 during A# 7840663.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 May 2023
Resolved
(a) Approved fire detection and alarm systems must be installed on the following vessels as set forth in subpart 76.27 of this part:
(2) Any vessel of more than 150 feet (45.72 meters) in length having sleeping accommodations for passengers;
Installed fire detection system is displaying a trouble alarm for the main deck galley and stores (zone 12). Conducted operational test of the system to include (zone 12).
Tested smoke detectors in zone 12, all sat. Vessel was unable to test heat detectors in zone 12. Galley is currently not being used.
Prior to operating any heat sources in zone 12, identify trouble alarm(s), replace faulty component(s), and test to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 July 2023
Resolution: Witnessed operational test of all heat and smoke detectors in zone 12, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2023
No resolution recorded
All automatic auxiliary boilers must be tested and inspected in accordance with this subpart and subpart 61.05 of this part. Crew has no records for testing of auxiliary boiler. Boiler is required to be tested during next quarterly re-inspection in April 2023. Provide boiler information to Marine inspector prior to next vessel quarterly inspection to determine boiler inspection requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 February 2023
Resolved
At each inspection the inspector shall conduct test and inspections of all hull equipment including all subdivision bulkheads to determine that their watertight integrity has not been impaired. Various sections of framing, girders, and bulkheads were found severely wasted from vessels watertight bulkhead, frame 33, to the aft machine shop bulkhead, frame 61. The attached documents of the vessels structural design drawings indicate all the areas that were found. Crop/renew to good metal indicated areas of concern to the satisfaction of an attending Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 February 2023
Resolved 27 February 2023
Resolution: Inspected all structural repairs,sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2023
Resolved
Fixed fire extinguishing systems must be checked as noted in table 71.25-20 (a)(2). In addition all parts of the fixed fire extinguishing system must be examined for general condition. Gaylord hood damper inoperable. Make repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 17 March 2023
Resolution: Third party cleaned and tested
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2023
Resolved
Where hose ports are fitted, they shall be cut in the lower corner of the door on the side opposite the hinge so that if the hose is passed through the doorway when the door is open, it may be closed over the hose. The cut for the hose port should be approximately 6 inches square. A hinged or pivoted steel or equivalent metal cover shall be fitted in the cut, equipped with a bullet catch or similar method of fastening which will permit easy and automatic operation of the hinged cover. Hose ports inoperable. Repair to requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 27 February 2023
Resolution: Inspected fire door hose ports, sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 February 2023
Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspections. Scupper pipe on starboard fwd. fuel void cut and unapproved repair installed. Make permanent repair to the satisfaction of an attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 16 March 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 February 2023
Resolved
Fire hazards shall be minimized insofar as is practicable. Excessive oil in the engine room bilge, steering room and starboard aft fuel oil tank supply valve leaking. Remove excess oil to the satisfaction of an attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 15 February 2023
Resolved 14 February 2023
Resolution: 10 c
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 February 2023
Resolved
All subdivision bulkheads shall be examined to determine that their watertight integrity has not been impaired. Clean bilges and provide access to bow thruster room, engine room and steering room/aft void.
Action required: 10 - Deficiency Rectified
Due 15 February 2023
Resolved 14 February 2023
Resolution: 10 C.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 January 2023
Resolved
At each inspection the inspector shall conduct test and inspections of all hull equipment including all subdivision bulkheads to determine that their watertight integrity has not been impaired. Inspectors discovered severe corrosion to hull plating, internal framing, watertight subdivision bulkheads and fuel tank bulkheads. Also discovered multiple deformed gussets adjacent to fuel tank. Wasted fuel tank plating must be renewed. Vessel is required to be dry-docked and made available for US Coast Guard inspection to determine condition of suspect hull plating and internal framing. Vessel must undergo external hull examination and internal structural examination.
The MISSISSIPPI must travel light boat from Memphis, TN to James Marine Inc. in Wickliffe, KY to undergo a US Coast Guard external hull examination and internal structural examination. Prior to departure the forward fuel tank must be stripped.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 February 2023
Resolution: Hull examination and ISE completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2023
Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valve. All three SSDG and port MDE fuel supply remote operated valves were inoperable. Replace or service valves so they can be operated remotely.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2023
Resolution: tested all fuel oil shutoff valves with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 January 2023
Resolved
Fixed fire extinguishing systems must be checked as noted in table 71.25-20 (a)(2). In addition all parts of the fixed fire extinguishing system must be examined for general condition. There was a cracked hose from a CO2 bottle to the discharge piping manifold on the engine room fixed CO2 system. Hose shall be replaced by authorized servicing provider.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2023
Resolution: replaced 3 hoses
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2023
Resolved
The inspection shall include inspection structure, boilers, pressure vessels, machinery and equipment. Piping shall be inspected to insure satisfactory condition. There was fuel leak on EDG fuel fill piping.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2023
Resolution: Inspected fuel system on EDG, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 January 2023
Resolved
The bulkhead deck must be water tight. Gaskets on all escape scuttles on the installed in the bulkhead deck (main deck)are deteriorated and no longer water tight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2023
Resolution: replaced gaskets and chalk tested
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 January 2023
Resolved
The inspection shall include machinery and equipment to insure equipment is in satisfactory condition and fit for the service in which it is intended. One of the two MSD discharge pumps has been removed from service but has not been locked or tagged out properly. Pump isolation valves are not locked closed posing the potential for sewage leak. Circuit breaker is not locked out and pump wires have exposed conductors posing potential electrical shock hazard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2023
Resolution: Inspected MSD pumps, no electrical hazard present. Circuit tagged out.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 January 2023
Resolved
Portable conatainers use to store flammable and combustible liquids must meet requirements of UL 30 or UL 1313. Portable containers must be stored in a paint locker or open location designated by the master. Multiple portable gasoline conatainers were found stored underneath the stbd rescue boat. Containers were not secured for sea. Several containers were missing caps or were not UL approved. Remove unserviceable or unapproved containers. Store containers in paint locker or suitable open location where they can be secured for sea.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2023
Resolution: Removed all unapproved gasoline containers from vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2023
Resolved
The grab line on lifebuoys shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum synthetic material having a minimum breaking strength of 1,350 pounds. The grab lines on the lifebuoys are deteriorated. Replace the lifebuoy grab lines
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 16 March 2023
Resolution: The lifebuoy grab lines were replaced with new grab lines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 January 2023
Resolved
Power operated steering systems must have limit switches for cutting off power to the steering gear before the rudder reaches the stops. Stearing trunnions are hitting rudder stops. Adjust limit switches to proper settings.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 16 March 2023
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 January 2023
Resolved
In all ventilation systems manually operated dampers or other suitable means shall be provided outside the space served for shutting off the passage of air in event of fire. Ventilation cover gaskets are worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 16 March 2023
Resolution: New gaskets were placed around the ventilation covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 January 2023
Resolved
The inspection shall include inspection of machinery to insure it is in satisfactory condition and fit for service. EDG starter timer is malfuctioning causing the starter bendix to engage engine flywheel while engine is running. Engineers have to unwire starter after engine has started and operating to prevent malfunction.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2023
Resolved 31 July 2023
Resolution: Witnessed operation of EDG timer.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 18 January 2023
Resolved
Before the vessel leaves port and at all times during the voyage each lifesaving appliance must be in working order and ready for immediate use. Port rescue boat davit has significant leak on hydraulic cylinder. Vessel is equipped with two rescue boats and may operate with only one rescue boat. Port rescue boat davit shall not be used until hydraulic cylinder is repaired or replaced. The number of passengers is reduced from 113 to 107 for a total of 142 persons allowed to accommodate the rescue of the total persons allowed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 February 2023
Resolved 25 June 2024
Resolution: Davit was repaired. Witnessed weight test.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 January 2023
Resolved
Each liferaft must be arranged for float-free launching. The arrangement must ensure that the liferaft, when released and inflated, are not dragged under by the sinking vessel. The 03 inflatable buoyant apparatuses were not arranged for float-free launching. Vessel crew made repairs on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 January 2023
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 18 July 2022
Resolved
Generator prime movers must shut down automatically upon loss of lubricating oil pressure. Starboard SSDG did not shut down upon loss of lube oil pressure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2022
Resolved 8 August 2022
Resolution: Caterpillar technician replaced oil sensor sending unit. Provided copy of service report
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 18 July 2022
Resolved
If vessels certificate of inspection is renewed annually, the setting of the safety relief valve on pressure vessels must be checked annually. Vessel could not provide relief valve setting documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2022
Resolved 18 January 2023
Resolution: Vessel installed new pressure relief valves
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 July 2022
Resolved
Doors in main vertical zone bulkheads shall be of the self-closing type. Several fire doors would not self close. Rectify deficiency within 90 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2022
Resolved 17 March 2023
Resolution: doors adjusted and tested
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 July 2022
Resolved
The fire detection and alarm system must be so arranged and installed that the presence of a fire in any protected space will be automatically registered visually and audibly on the fire control panel. The visible notice must indicate the zone in which the alarm originated. Several fire detectors did not correlate to proper location on fire alarm panel. Rectify deficiency within 90 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 October 2022
Resolved 8 August 2022
Resolution: Problem was caused by 2 pull stations not being reset. When conducting smoke test, alarm panel was showing trouble alarm in zone were pull station was not reset. Conducted spot check of 25 smoke detectors, all sat.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 18 July 2022
Resolved
Fire and Control plan must be approved by cognizant [name withheld] fire control plan has not been stamped "approved". Verify contents of plan and submit to OCMI for approval.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2022
Resolved 31 July 2025
Resolution: Fire control plan signed and marked approved by SLMR OCMI.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 18 July 2022
Resolved
Drills must be conducted in the presence of a marine inspector. Full crew compliment was not present at time of inspection to conduct drills. Conduct drills in the presence of CG Marine Inspector within 14 days.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 8 August 2022
Resolution: Conducted satisfactory fire and man overboard drill
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 March 2022
Resolved
As an alternative to the survival craft requirements of § 199.201(b), vessels may carry inflatable buoyant apparatus having an aggregate capacity sufficient to accommodate 67 percent of the total number of persons on board, minus the capacities of any lifeboats, rescue boats and life-rafts carried on board. These inflatable buoyant apparatus must meet the arrangement requirements of § 199.630 (d)(1) through (d)(3). The number of persons accommodated in an inflatable buoyant apparatus may not exceed 150% of its rated capacity.
Two (02) Inflatable Buoyant Apparatus' are on-board having a total capacity for 60 persons; not meeting 67% of total number of persons on-board. Passenger Count has been reduced to 74.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2023
Resolution: Three (03) Inflatable Buoyant Apparatuses are on board having a total capacity of 90 persons.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 6 October 2017
Resolved
3 of the 20 flexible loop hoses connecting the activation heads to the E/R system manifold were threaded on to the activation head and not tightened. They were loose enough to unscrew by hand. One of the 20 flexible loops was only placed against the threads, but not screwed onto the threads at all and came off the fitting upon placing a hand on it. This would potentially caused a major failure of the E/R fixed CO2 system, had there been an E/R fire and the system was activated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2017
Resolution: Ship's engineers were immediately notified of the situation. Ship's force tightened all loose flexible loops and placed the system back in service.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 6 October 2017
Resolved
Battery operated e-light in MSD space did not operate when test button was pressed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2017
Resolved 6 October 2017
Resolution: Batteries were replaced on the spot by ship's force.
Construction/Loadline › Structures › Door
Issued 6 October 2017
Resolved
3 water tight doors below the main deck required adjustment. When doors were closed, up to 4 of the 6 dogs were loose and not engaged with the pads on the frame. At least one hand wheel was loose.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2017
Resolved 6 October 2017
Resolution: Ship's force completed adjustment of all water tight doors on the spot.
Electrical › Electric Generation Source (emergency) › Generator
Issued 1 August 2017
Resolved
Emergency generator windings are destroyed. Temporary EDG is in place and hard wired into emergency circuit panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 17 October 2017
Resolution: Vessel replaced emergency generator with new. Witnessed test and satisfactory shift of power through emegency switch board. All SAT.
Construction/Loadline › Hull › Weld
Issued 14 July 2017
Resolved
Found pin hole leak in center shaft tube, a welded doubler patch is allowed for temp repairs until permanent repairs can be made upon dry dock availability.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 10 July 2018
Lifesaving › Lifejacket/PFD (Type I) › Size
Issued 7 March 2017
Resolved
Provide 16 Type I child size life jackets as per COI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 24 January 2018
Resolution: Vessel has appropriate lifejacket count in servicable condition.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 6 March 2017
Resolved
Watertight door indicators must be operable on the pilot house
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 24 January 2018
Resolution: Wiring for display panel was disconnected. Technician reconnected and tested satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 6 March 2017
Resolved
Starboard engine failed to shut down during emergency procedures due to faulty valve air intake.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 8 March 2017
Resolution: MI witnessed satisfactory overspeed shutdown after install of new valve.
Operations/Management › Drills/Instruction › Fire
Issued 18 January 2017
Resolved
Machinery space fire drill was conducted, observed multiple deficencies during drill. Crew must conduct machinery space fire drill to satisfaction of the [name withheld].
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2017
Resolved 6 March 2017
Resolution: Conducted satisfactory E/R fire drill.
Communications › Alarms/Indicators › General Alarm
Issued 18 January 2017
Resolved
02 deck general alarm is inoperable, verify GE, bell & lights, PTCP.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2017
Resolved 6 March 2017
Communications › Visual Communication › Warning Sign (gangway)
Issued 31 August 2016
Resolved
Provide necessary markings for fire and emergency equipment missing throughout the vessel (CO2 alarms, manual alarm boxes, portable fire extinguishers, E-Lights, Etc...)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 24 January 2018
Resolution: Vessel label and marked all emergency equipment IAW IMO standards.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 29 June 2016
Resolved
Prove servicing of IBA's prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 13 July 2016
Resolution: IBAs serviced and returned to the vessel for installation.
Engineering › Electric Propulsion System › Winding
Issued 9 March 2016
Resolved
Prove proper function of the 250 horse power Veth-Jet bow thruster in the presence of an attending USCG marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 22 June 2016
Resolution: Demonstrated proper operation
Communications › Alarms/Indicators › General Alarm
Issued 9 March 2016
Resolved
General alarm in engine room needs a placard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 22 June 2016
Resolution: witnessed installed.
Communications › Alarms/Indicators › General Alarm
Issued 9 March 2016
Resolved
Repair general alarm bell in main control room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 24 March 2016
Resolution: MI witnessed operation.
Communications › Alarms/Indicators › General Alarm
Issued 9 March 2016
Resolved
Repair general alarm bells from frame 50-51.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 24 March 2016
Resolution: MI observed operation. Electrical short caused the inop alarm bells.
Lifesaving › Launching Appliances › Davit
Issued 9 March 2016
Resolved
port and starboard rescue boat davits need annual service.
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 24 March 2016
Resolution: MI witnessed annual light boat weight test and full function test by third party contractor.
Lifesaving › Launching Appliances › Davit
Issued 9 March 2016
Resolved
Prove port side rescue boat limit switch functions properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2016
Resolved 22 June 2016
Resolution: Witnessed proper operation of limit switch.
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 June 2012
Resolved
Provide a properly operating Emergency Generator, Capable of Automatic starting. Currently the diesel engine driving the Emergency Generator is inoperable. (Faulty Starter ?)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2012
Resolution: Witnessed proper automatic start up and assumption of the load by the Emergency Generator.
Electrical › Electrical Distribution System (service) › Switch
Issued 6 June 2012
Resolved
Provide a properly operating Machinery Stop Station for the Fuel Oil Transfer and Service Pump meeting the requirements of 46 CFR 111.103-7. Currently the installed machinery stop station on the engine room console does not secure these pumps as required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2012
Resolution: Witnessed proper operation of the Break Glass Emergency stop for the fuel oil transfer pump.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 6 June 2012
Resolved
Provide a properly operating rudder angle indicator for the STBD Flanking rudder in aft steering, where non follow up steering control is available. Currently the STBD flanking rudder angle indicator will not indicate greater than 5 degrees to port, when rudder is hard over to port.
Condition: Improper/Lack of Maintenance
Due 12 July 2012
Resolved 26 June 2012
Resolution: Witnessed proper operation of the Starboard Flanking Rudder Angle Indicator.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 26 July 2011
Resolved
Provide a properly serviced fixed fire CO2 extinguishing systems throughout the vessel. Currently numerous hose between the CO2 bottles and the distribution manifold are beginning to show signs of deterioration. 46 CFR 71.25-20
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 30 August 2011
Resolution: Attended the vessel observed the hoses had bee properly replaced.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 26 July 2011
Resolved
In accordance with 46 CFR 16.240 and 4.06 provide a policy and the means of chemical/ Drug testing following a Serious Marine Incident within the required time frames. Currently no means of providing a alcohol test is available for individuals involved in a serious marine incident.
Condition: Improper/Lack of Maintenance
Due 1 October 2012
Resolved 9 July 2012
Resolution: Determined the MOU between the USCG and the ACOE meets the intent of the regulation.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 25 July 2011
Resolved
Provide proper reverse power relay protection for the Generators and Electrical Distribution System prior to 8/26/2011, until satisfactory ensure 2 person engineering watches including 15 minute rounds of the Generator while in Parallel operation. Ensure they trip as per the manufacturers recommendation. Currently the Port Gen Reverse power relay inoperable.46 CFR 111.12-11
Condition: Improper/Lack of Maintenance
Due 26 August 2011
Resolved 30 August 2011
Resolution: Observed Proper operation of the vessels reverse power relays.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 25 July 2011
Resolved
Remove all fuel oil accumulations from the machinery space bilges which create a fire hazard. The Fuel Oil Transfer pump was replaced and excessive fuel oil was present in the bilge. Corrected on the Spot. Witnessed proper operation of the pump and the remote pump shut down.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2011
Engineering › Steam Boiler (auxiliary/waste heat) › Combustion Chamber
Issued 25 July 2011
Resolved
Conduct a satisfactory fire side inspection and hydro test of the auxiliary boiler in the presence of an attending Coast Guard Marine Inspector prior to operation of the Auxiliary Boiler. Currently the heating boiler is overdue for these required inspections. 46 CFR 61.05-10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 September 2011
Resolution: Witnessed proper operation of the boiler following the fire side and hydrostatic test of the boiler.
Communications › Internal Communications System › Sound-powered Telephone
Issued 25 July 2011
Resolved
Provide a properly operating Sound Powered Phone in the Steering Room. Currently the installed sound powered phone is inoperable. Until repaired provide portable radios with adequate provisions for hearing in machinery spaces. 46 CFR 113.30-25
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2011
Resolved 29 July 2011
Resolution: Verified proper operation of the sound powered phone system.
Stability › Watertight Integrity › General
Issued 25 July 2011
Resolved
Provide proper escape hatches for the Bow Thruster Room and the A/C Rooms. During the Inspection the hatches in those spaces were inoperable. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2011
Fire Fighting › Fire Hydrants › Condition
Issued 25 July 2011
Resolved
Provide properly maintained fire station enclosures throughout the vessel, to ensure firefighting equipment is ready for use. Current fire stations 13 and 17 storage cabinets were observed to be inoperable due to excessive paint or damaged hinges or latches. 46 CFR 78.17-80
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 August 2011
Resolved 29 July 2011
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 July 2011
Resolved
Provide a proper plan to provide adequate security to the vessel and passengers at all times when passengers are aboard IAW 46 CFR 78.30-20 Currently passengers are aboard the vessel both during public hearings and at other times.
Due 1 October 2011
Resolved 1 October 2011
Resolution: Opened in error this is a duplicate of item 17
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 24 January 2011
Resolved
Provide properly approved drawings of the proposed alterations to replace the Alarm and Monitoring System Prior to carrying Passengers.
Condition: Placed in Improper Service
Due 1 March 2011
Resolved 23 March 2011
Resolution: Automation Verification Test Procedure function checked. Chief Engineer set off each alarm which passes through automation panels. Ex: MDE alarms, bilge alarms, Fire Detection smoke & Heat alarms ect.... All remote panels in Automation system sounded sat
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 16 March 2009
Resolved
THERE IS CURRENTLY MORE THAN 6" OF OIL IN THE ENGINE ROOM BILGES. PUMP OIL OUT OF BILGES.
Action required: 705 - Other - as specified
Due 20 March 2009
Resolved 28 April 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 16 March 2009
Resolved
AS DIRECTED BY THE MARINE INSPECTOR REPLACE 5 PORTABLE FIRE EXTINGUISHERS WITH A, B, C-TYPE IN VARIOUS LOCATIONS THROUGH-OUT THE VESSEL. ADJUST FIRE PLAN TO REFLECT CHANGES.
Action required: 705 - Other - as specified
Due 24 March 2009
Resolved 24 March 2009
Engineering › Generator (propulsion-electric) › Measurement Circuitry
Issued 16 March 2009
Resolved
MAKE OPERABLE, LUBE-OIL TEMP AND LUBE-OIL PRESSURE SENSORS FOR THE STBD GENERATOR.
Action required: 705 - Other - as specified
Due 16 April 2009
Resolved 16 April 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Air-flex Clutch
Issued 15 October 2008
Resolved
Make permanent repairs to port main engine/port reduction gear coupling. Vessel is authorized to continue to operate in its towing mission, in a twin screw configuration, with loaded tow configurations not exceeding (12) barges; and empty tow configurations, not exceeding (16) barges. Vessel is not authorized carriage of passengers. Notify local OCMI if conditions change throughout transit.
Action required: 705 - Other - as specified
Due 14 December 2008
Resolved 16 March 2009
Resolution: Repairs verified during COI.
Fire Fighting › Fire Hoses › Length
Issued 17 July 2008
Resolved
Lengthen fire hose (Fire Station #8/Main Deck-Port Side) to 75'. Hose is currently 50' and unable to reach galley space.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 24 July 2008
Personnel › Training › First Aid/CPR
Issued 17 July 2008
Resolved
Provide Red Cross First-Aid/CPR training certification cards for 2 additional crewmembers.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 24 July 2008
Construction/Loadline › Structures › Scuttle
Issued 17 July 2008
Resolved
Make operable, emergency escape hatch in bow thruster compartment. Ensure hatch does not leak. (Hatch currently will not open without great force, and leaks when it rains).
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 24 July 2008
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 8 May 2008
Resolved
Baffle plate in stbd washwater tank has numerous fractures which ranges from 1/8" to 1/2" near floor frame.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2008
Resolved 3 June 2008
Resolution: corrected
Deck/Cargo › Ballast › Tank
Issued 8 May 2008
Resolved
Provide evidence of painting contract for ballast and wash tanks.
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 25 June 2008
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 5 March 2008
Resolved
MAKE ALL VENTILATION CLOSURE COVERS OPERABLE (REMOVE PAINT BUILD-UP ON CLOSURES).
Action required: 705 - Other - as specified
Due 17 March 2008
Resolved 14 May 2008
Resolution: completed
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 5 March 2008
Resolved
PROPERLY INSTALL STARBOARD LIFERAFT IN CRADLE (HYDROSTATIC RELEASE UNIT ASSEMBLY NOT ATTACHED).
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 March 2008
Resolved 14 May 2008
Resolution: completed
Deck/Cargo › Cargo Transfer (solid) › General
Issued 5 March 2008
Resolved
REPLACE CABLE ON PORT DECK CRANE/DAVIT (CABLE FRAYED).
Action required: 705 - Other - as specified
Due 17 March 2008
Resolved 14 May 2008
Resolution: completed
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 March 2008
Resolved
MAKE STARBOARD STERN RING-LIFEBUOY WATERLIGHT OPERABLE.
Action required: 705 - Other - as specified
Due 17 March 2008
Resolved 14 May 2008
Resolution: completed
Communications › Alarms/Indicators › General Alarm
Issued 5 March 2008
Resolved
MAKE ENGINE-ROOM GENERAL ALARM LIGHT OPERABLE (STROBE DOES NOT ROTATE).
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2008
Resolved 14 May 2008
Resolution: completed
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 March 2007
Resolved
Clean or calibrate oil content detector (OCD) sensor to insure proper operation of oil recirculation solenoid valve.
Action required: 705 - Other - as specified
Resolved 20 November 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 July 2006
Resolved
Place solas grade retroreflective tape on life rings in rescue boat
Due 14 July 2006
Resolved 12 July 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 6 July 2006
Resolved
modifications to the fixed fire extinguishing system must be approved by Coast Guard or pull cables are replaced in kind.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2006
Resolved 12 July 2006
Resolution: The vessel removed 170ft of pull cable and 28 pulleys. The installation was 9ft of cable and 7 pulleys. Conducted test on the system and the test was satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 23 March 2006
Resolved
Replace all empty CO2 cylinders with refilled cylinders in engine room, generator room, emergency generator room, and paint locker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2006
Resolution: All used CO2 cylinders replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 March 2006
Resolved
Properly mark wires with destination of each wire and the shutdown function on Pressure Switches.
Action required: 705 - Other - as specified
Due 5 April 2006
Resolved 4 April 2006
Resolution: Pressure switches properly marked
Engineering › Generator (propulsion/auxiliary-electric) › Remote Control Circutry
Issued 23 March 2006
Resolved
Install and present proper operation of an emergency shutdown for emergency generator in conjunction with fixed CO2 Extinguishing System. IAW 46 CFR 112.50-1 (h).
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 6 July 2006
Resolution: Crewman shut down emergency generator by pulling kiddi switch.
Stability › Watertight Integrity › General
Issued 24 May 2005
Resolved
Prior to carrying passengers demonstrate proper operation of watertight door position indicator at frame #47.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2005
Resolution: Rewired door posistion indicator.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 24 May 2005
Resolved
Provide adequate containment of aft MSD to prevent and detect overflow of system
Due 24 June 2005
Resolved 27 July 2005
Resolution: Installed new containment for aft MSD.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 24 May 2005
Resolved
Post oil discharge prohibited placards at all fueling stations
Due 24 June 2005
Resolved 4 August 2005
Resolution: Posted placards
Construction/Loadline › Hull › Hull Plating
Issued 24 May 2005
Resolved
provide guaging report of the metal plating in the area of aft MSD.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Resolution: Conducted gauging of metal plating. Metal in area not wastage.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 May 2005
Resolved
wire brush, lube , or replace all closure devices for allport and starboard vent covers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Resolution: Brushed, lubed, and replaced to proper operation.
Accommodation/Occupational Safety › Messroom › Location
Issued 24 May 2005
Resolved
sanitize ice maker in MRC dining room
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Resolution: Ice maker sanitized.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 May 2005
Resolved
remove and properly store lifevest from light fixure in paint locker
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Resolution: Life vest properly stored.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 24 May 2005
Resolved
properly staore propane tank next toport stack
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Resolution: Propane tank properly stored in flam locker.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2005
Resolved
remove and properly store florr finish in elevator
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Resolution: Floor finish properly stored in storage locker.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 May 2005
Resolved
demonstrate proper operation of FSD 01-38-02
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Resolution: Door properly operable.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 May 2005
Resolved
replace service tag on fire extinguisher located next to port stack
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2005
Communications › Radio Communications › Cellular Telephone Capability
Issued 22 March 2005
Resolved
Secure junction box cover to stbd side, 03 deck for phones.
Condition: Improper/Lack of Maintenance
Due 2 April 2005
Resolved 6 April 2005
Resolution: Secured junction box cover.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 22 March 2005
Resolved
Remove all combustible material stowed in compartment on 03 deck behind door marked (WEA DR 03-53-2).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Resolution: Removed all combustible material stowed in compartment on 03 deck behind door marked (WEA DR 03-53-2).
Fire Fighting › Firemans Outfit › Axe
Issued 22 March 2005
Resolved
Replace / repair fire axe handle located on 03 deck.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Resolution: Repaired fire axe handle located on 03 deck.
Accommodation/Occupational Safety › Ventilation › General
Issued 22 March 2005
Resolved
Wire brush and lube closure devices for the port and stbd vent fan covers located on 03 deck.
Condition: Improper/Lack of Maintenance
Due 2 April 2005
Resolved 27 July 2005
Resolution: Wire brushed and lubed closure devices to proper operation.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 22 March 2005
Resolved
Prove proper operation of remote fire damper control located outside of cabin 303.
Condition: Unknown
Due 2 April 2005
Resolved 6 April 2005
Resolution: Showed proper operation of remote fire damper control located outside of cabin 303.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 22 March 2005
Resolved
Remove paint and all other flammables from Fan Room 207.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Resolution: Removed paint and all other flammables from Fan Room 207.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 22 March 2005
Resolved
Prior to April 2005 trip, provide and post a muster list and emergency instructions IAW 46 CFR 199.80; taking into account a full crew and partial crew as permitted by the vsl's COI. Provide for review to MSO Memphis.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 April 2005
Resolution: posted muster list
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 22 March 2005
Resolved
Hard wire the chemical flow meter for the aft Type II MSD to a junction box.
Condition: Improper Installation
Due 2 April 2005
Resolved 6 April 2005
Resolution: Hard wired the chemical flow meter for the aft Type II MSD to a junction box.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 22 March 2005
Resolved
Route the vent line for the Type II MSD (2nd Stage) to outside of the vessel's interior. The end of the vent line points into a 5 gal. bucket, aft of the MSD.
Condition: Improper Installation
Due 6 May 2005
Resolved 24 May 2005
Resolution: changed requirement
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 22 March 2005
Resolved
Hard wire the bilge high water alarm located in a 5 gal. bucket next to the aft Type II MSD.
Condition: Unknown
Due 2 April 2005
Resolved 6 April 2005
Resolution: Hard wired the bilge high water alarm located in a 5 gal. bucket next to the aft Type II MSD.
Accommodation/Occupational Safety › Ventilation › General
Issued 22 March 2005
Resolved
Wire brush and lube closure devices for the port and stbd vent fan covers located on stack deck
Condition: Improper/Lack of Maintenance
Due 2 April 2005
Resolved 27 July 2005
Resolution: Wire brushed and lubed closure devices to proper operation.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 22 March 2005
Resolved
Remove all flammables from Fan Room 203.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Resolution: Removed all flammables from Fan Room 203.
Fire Fighting › Grease Extraction Hood › General
Issued 22 March 2005
Resolved
Provide service report for both galley range hood Ansul fire extinguishing systems.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2005
Resolution: report received
Engineering › Pressure Vessel › Relief Valve
Issued 22 March 2005
Resolved
Provide test report for laundry room hot water heater relief valve.
Condition: Unknown
Due 6 May 2005
Resolved 6 April 2005
Resolution: Provided test report for laundry room hot water heater relief valve.
Fire Fighting › Grease Extraction Hood › General
Issued 22 March 2005
Resolved
Provide cleaning solution for main deck galley Gaylord system and prove proper operation.
Condition: Improper/Lack of Maintenance
Due 2 April 2005
Resolved 6 April 2005
Resolution: Provided cleaning solution for main deck galley Gaylord system and proved proper operation.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 22 March 2005
Resolved
Provide and install magnetic hold-backs for all doors in both galleys.
Condition: Placed in Improper Service
Due 6 May 2005
Resolved 24 May 2005
Resolution: magnetic hold-backs installed
Fire Fighting › Structural - A Class Divisions › Open Deck Spaces
Issued 22 March 2005
Resolved
Provide and install a grate or other barrier to prevent stowage of items under stairs on main deck between doors.
Condition: Placed in Improper Service
Due 6 May 2005
Resolved 6 April 2005
Resolution: Subject vessel is to provide a placard stating that nothing can be placed under stairs.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 22 March 2005
Resolved
Provide documented evidence that sound and vibration tiles installed on board (engine rm, aux mach. space, and elsewhere not yet identified) are non combustible IAW 46 CFR 164.009 or remove all tiles.
Condition: Design Flaw
Due 30 November 2005
Resolved 12 July 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 22 March 2005
Resolved
Provide a working copy of the vessel's fire control plan for space to space verification.
Condition: Design Flaw
Due 6 May 2005
Resolved 24 May 2005
Resolution: fire control plan provided
Communications › Alarms/Indicators › Refrigerated Spaces Alarm System
Issued 22 March 2005
Resolved
Provide and install an alarm that can be activated from inside the galley's walk in freezer that sounds outside that space, ie: galley, pilot-house, or engine control room. IAW 46 CFR 77.05-1. or remove the lock hasp.
Condition: Unknown
Due 6 May 2005
Resolved 6 April 2005
Resolution: Removed the lock hasp.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 22 March 2005
Resolved
Replace all trash cans with trash cans made of an incombustible material. IAW 46 CFR 72.05-55
Condition: Unknown
Due 6 May 2005
Resolved 6 April 2005
Resolution: Replaced all trash cans with trash cans made of an incombustible material.
Documentation › Logs/Records › Logbook (official)
Issued 22 March 2005
Resolved
IAW 46 CFR 78.37-3(b) and 78.37-5, log all required actions including 78.37-10.
Condition: Unknown
Due 10 May 2005
Resolved 24 May 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 March 2005
Resolved
IAW 46 CFR 199.180 (c) and (f) conduct all required drills: abandon ship and fire.
Condition: Unknown
Due 10 May 2005
Resolved 6 April 2005
Resolution: Conducted all required drills: abandon ship and fire.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 22 March 2005
Resolved
Insure all hand portable fire extinguishers are marked IAW 46 CFR 78.47-30.
Condition: Improper/Lack of Maintenance
Due 6 May 2005
Resolved 6 April 2005
Resolution: All hand portable fire extinguishers are marked IAW 46 CFR 78.47-30.
Communications › Alarms/Indicators › General Alarm
Issued 22 March 2005
Resolved
Insure all general alarm bell placards are properly affixed to bulkhead.
Condition: Improper Installation
Due 6 May 2005
Resolved 6 April 2005
Resolution: All general alarm bell placards are properly affixed to bulkhead.
Fire Fighting › Self-contained Breathing Apparatus › Approval
Issued 22 March 2005
Resolved
Insure SCBA locker, ie: Repair Locker is marked IAW 46 CFR 78.47-27.
Condition: Improper Installation
Due 6 May 2005
Resolved 6 April 2005
Resolution: SCBA locker, ie: Repair Locker is marked IAW 46 CFR 78.47-27.
Engineering › Steering Gear System › Hand Pump
Issued 22 March 2005
Resolved
Insure instructions for changing steering gear are posted in aft steering compartment IAW 46 CFR 78.47-55.
Condition: Unknown
Due 6 May 2005
Resolved 24 May 2005
Resolution: instructions posted
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 March 2005
Resolved
Demonstrate proper operation of water light attached to lifebouy on starboard side aft on main deck IAW 46 CFR 199.70 (e) (2).
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Resolution: Water light worked properly.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 March 2005
Resolved
Remove from the fireman suit stowage locker all unrelated equipment and properly organize the space in accordance to good marine practices.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Resolution: Removed all unrelated equipment and properly organize the space.
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 March 2005
Resolved
Provide and post lifejacket donning procedures at each lifejacket stowage bin, IAW 46 CFR 199.80 (c) (5).
Condition: Improper/Lack of Maintenance
Due 22 April 2005
Resolved 6 April 2005
Resolution: Posted lifejacket donning procedures at each lifejacket stowage bin.
Communications › Audible Communications › SPD (Other)
Issued 22 March 2005
Resolved
Mount P/A speaker on stack deck located amidships.
Condition: Improper/Lack of Maintenance
Due 22 April 2005
Resolved 6 April 2005
Resolution: Mounted P/A speaker.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 22 March 2005
Resolved
Stow all paint and aerosol containers not in daily use in a paint locker or flammable products locker IAW good marine practice.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Resolution: Stowed all paint and aerosol containers not in daily use in a paint locker or flammable products locker IAW good marine practice.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 March 2005
Resolved
Provide for and demonstrate to the attending USCG Marine Inspector proper operation of all doors fitted with automatic closure devices IAW 46 CFR 72.05-25 (b) (9) (ii).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Resolution: Provided for and demonstrated to the attending USCG Marine Inspector proper operation of all doors fitted with automatic closure devices IAW 46 CFR 72.05-25 (b) (9) (ii).
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 22 March 2005
Resolved
Provide proof of annual service on all portable fire extinguishers on board IAW 46 CFR 97.15-60 (b).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Resolution: Provided proof of annual service on all portable fire extinguishers.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 22 March 2005
Resolved
Replace portable fire extinguisher #3-79-2 missing from bracket in engine room IAW 46 CFR 95.50 and as noted on the FCP.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Resolution: Replaced portable fire extinguisher #3-79-2 missing from bracket in engine room.
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 22 March 2005
Resolved
Demonstrate safe operation of heating apparatus in outboard cabin bathrooms IAW 46 CFR 72.20-50.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2005
Resolution: Demonstrated safe operation of heating apparatus in outboard cabin bathrooms.
Communications › Audible Communications › SPD (Other)
Issued 2 August 2004
Resolved
Provide a written statement from the master or chief engineer stating that the P.A. system in the Public Hearing room is operatinal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2004
Resolution: Received a signed statement from the vessel''s chief engineer stating that the P.A. system has been repaired and tested.
Operations/Management › Drills/Instruction › Fire
Issued 5 May 2004
Resolved
With a full crew on board, demonstrate a fire, abandon ship, and man overboard drill in the presence of a USCG mairne inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2004
Resolution: Observed sat drills.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 5 May 2004
Resolved
Provide a service report stating that the vessel's fixed CO2 fire extingushing systems are back in normal operation after all of the CO2 cylinders have been hydrostatically tested.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2004
Resolution: Service report review and system was spot checked sat.
Communications › Audible Communications › SPD (Other)
Issued 5 May 2004
Resolved
Prove the proper operation of the P.A. system in the Hearing Room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2004
Resolution: Tested sat.
Electrical › Lighting (emergency)
Issued 5 May 2004
Resolved
Provide and install an Emergency lighting fixture in the forward MSD compartment over the fixed CO2 system controls. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2004
Resolution: Observed sat.
Electrical › Lighting (emergency)
Issued 5 May 2004
Resolved
Repair the Emergency lighting fixture on the port side, 01 deck above the life raft. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2004
Resolution: Observed sat.
Electrical › Lighting (emergency)
Issued 5 May 2004
Resolved
Provide and install Emergency lighting fixtures on the port and starboard sides, 02 deck above both I.B.A.s. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2004
Resolution: Observed sat.
Communications › Alarms/Indicators
Issued 5 May 2004
Resolved
Repair the General Alarm red rotating light in the steering compartment. LEGACY COMPONENT DESC: General Alarm
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2004
Resolution: New light installed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 5 May 2004
Resolved
All paint stored in the paint locker must to stowed off the deck in order to make access to the fuel oil valve remote controls.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2004
Resolution: Observed sat.
Accommodation/Occupational Safety › Ventilation
Issued 5 May 2004
Resolved
Make available the laundry room's clothes dryer ventilation terminus for inspection.
Due 20 May 2004
Resolved 27 May 2004
Resolution: Inspected sat.
Fire Fighting › Ventilation Systems
Issued 5 May 2004
Resolved
Prove the proper operation of the vent duct damper control in the generator room, on the port side near the deck. LEGACY COMPONENT DESC: Operating Controls
Due 20 May 2004
Resolved 20 May 2004
Resolution: Test operated sat.
Fire Fighting › Ventilation Systems
Issued 5 May 2004
Resolved
Prove the proper opeation of the vent duct damper control in the generator room on the starboard side near the overhead. LEGACY COMPONENT DESC: Operating Controls
Due 20 May 2004
Resolved 20 May 2004
Resolution: Test operated sat.
Fire Fighting › Ventilation Systems
Issued 5 May 2004
Resolved
Prove the proper opeation of the vent duct damper control on the main deck near fire door 48. LEGACY COMPONENT DESC: Operating Controls
Due 20 May 2004
Resolved 20 May 2004
Resolution: Test operated sat.
Fire Fighting › Ventilation Systems
Issued 5 May 2004
Resolved
Prove the proper operation of the vent duct damper control on the main deck near fire door 45. LEGACY COMPONENT DESC: Operating Controls
Due 20 May 2004
Resolved 20 May 2004
Resolution: Test operated sat.
Fire Fighting › Ventilation Systems
Issued 5 May 2004
Resolved
Prove the proper operation of the vent duct damper control on the main deck near fire door 17. LEGACY COMPONENT DESC: Operating Controls
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2004
Resolution: Test operated sat.
Fire Fighting › Ventilation Systems
Issued 5 May 2004
Resolved
Prove the proper operation of the vent duct damper located in the laundry room. LEGACY COMPONENT DESC: Operating Controls
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2004
Resolution: Test operated sat.
Fire Fighting › Ventilation Systems
Issued 5 May 2004
Resolved
Prove the proper operation of the vent duct damper located in the radio room. LEGACY COMPONENT DESC: Operating Controls
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2004
Resolution: Test operated sat.
Electrical › Electric Supply System (service)
Issued 5 May 2004
Resolved
Replace the wire nuts in the fuel oil purifer controller with compression splices or solder the connection. LEGACY COMPONENT DESC: Cable
Due 20 May 2004
Resolved 20 May 2004
Resolution: Wire nuts removed and proper mechanical splice installed.
Electrical › Electric Supply System (service)
Issued 5 May 2004
Resolved
Replace the wire nut in the lube oil purifer controller with compression splices or solder the connection. LEGACY COMPONENT DESC: Cable
Due 20 May 2004
Resolved 20 May 2004
Resolution: Wire nuts removed and proper mechanical splice intalled.
Fire Fighting › Fire Hoses › Number
Issued 5 May 2004
Resolved
Provide on board three 1.5 inch fire hoses that meet the 46 Code of Federal Regulations 76.10-10(n)(2). Fire hose shall be UL Standard 19 or Federal Spec. ZZ-H-451E.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2004
Resolution: Observed sat.
Lifesaving › Lifejacket/PFD (Type I)
Issued 5 May 2004
Resolved
Mark the engine room life jacket storage locker in accordance with 46 Code of Federal Regulations 199.70. LEGACY COMPONENT DESC: Storage
Due 20 May 2004
Resolved 20 May 2004
Resolution: Marked sat.
Lifesaving › Lifejacket/PFD (Type I)
Issued 5 May 2004
Resolved
In passenger and crew cabins, provide the same style of Type I life jacket or post donning instructions for each type of life jacket provided in each cabin. LEGACY COMPONENT DESC: Storage
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2004
Resolution: Spot checked sat.
Lifesaving › Lifejacket/PFD (Type I)
Issued 5 May 2004
Resolved
Provide one Type I life jacket in the radio room. LEGACY COMPONENT DESC: Quantity
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2004
Resolution: Provided.
Documentation › Manuals/Policy Documentation
Issued 5 May 2004
Resolved
Provide on board Oil Transfer Procedures in accordance with 33 Code of Federal Regulations 155.720. LEGACY COMPONENT DESC: Transfer Procedures
Action required: 703 - Prior to bunkering operations
Resolved 20 May 2004
Resolution: Noted sat.
Lifesaving › Launching Appliances
Issued 5 May 2004
Resolved
Weight test both boat davits and provide documentation as to when the falls were last renewed. LEGACY COMPONENT DESC: Falls
Due 20 May 2004
Resolved 20 May 2004
Resolution: Test conducted and rescue boat winch and wire renewed in May 2004.
Accommodation/Occupational Safety › Medical/First Aid
Issued 5 May 2004
Resolved
Provide on board a USCG Approved First Aid Kit that meets 46 Code of Federal Regulations 160.041.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2004
Resolution: New first aid kit provided in pilot house.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 5 May 2004
Resolved
Repair or replace the local control for Fire Door 02-45-1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2004
Resolution: Tested and observed sat.
Operations/Management › Drills/Instruction › Fire
Issued 5 May 2004
Resolved
Conduct and log weekly fire and abaondon ship drills in accorand with 46 Code of Federal Regulations 199.250
Due 31 August 2004
Resolved 12 July 2004
Resolution: Noted sat.
Fire Fighting › Fixed Fire Detection System
Issued 6 April 2004
Resolved
Prove the proper operation of all of the smoke detectors. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2004
Resolution: All of the smoke detectors have been replaced with new detectors.
Lifesaving › Inflatable Liferafts
Issued 6 April 2004
Resolved
Provide and install a new hydrostatic releases for both of the IBAs. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2004
Resolution: A new hydrostatic release was installed for each IBA.
Operations/Management › Drills/Instruction
Issued 7 May 2003
Resolved
Demonstarate fire, abandon ship, and man overboard drills for the U.S. Coast Guard. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2003
Resolution: Observed satisfactory.
Engineering › Steering Gear System
Issued 7 May 2003
Resolved
Prove proper operation of the vessel's steering systems. LEGACY COMPONENT DESC: Ram Seal
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2003
Resolution: Observed satisfactory.
Construction/Loadline › Structures
Issued 7 May 2003
Resolved
Conduct air test on port side lube oil tank in the presence of a Coast Guard marine inspector. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Resolved 8 July 2003
Resolution: Observed satisfactory.
Construction/Loadline › Structures
Issued 7 May 2003
Resolved
Rework the escape scuttle in the bow thruster compartment. LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2003
Resolution: Observed satisfactory.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 7 May 2003
Resolved
Reposition main deck galley hood fixed fire extinguishing system nozzle to cover both of the deep-fat fryers. LEGACY COMPONENT DESC: Nozzles
Condition: Improper Installation
Due 8 June 2003
Resolved 8 July 2003
Resolution: Observed satisfactory.
Construction/Loadline › Hull
Issued 5 December 2002
Resolved
Repair transverse hull weld forward of flanking rudders. LEGACY COMPONENT DESC: Weld
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 January 2003
Resolution: Observed sat repairs.
Engineering › Sea-water System (primary cooling)
Issued 5 December 2002
Resolved
Repair/replace port spool piece due to erosion and pitting. LEGACY COMPONENT DESC: Sea Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 January 2003
Resolution: Observed sat repairs.
Engineering › Steering Gear System
Issued 5 December 2002
Resolved
Repair all three rudders due to leaking. LEGACY COMPONENT DESC: Rudder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 January 2003
Resolution: Observed sat repairs.
Construction/Loadline › Structures
Issued 5 December 2002
Resolved
Repair all Kort nozzles at about the six o-clock position near the main screws. LEGACY COMPONENT DESC: Kort Nozzles
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 January 2003
Resolution: Observed sat repairs.
Fire Fighting › Structural Fire Protection - General
Issued 5 December 2002
Resolved
Provide documentation from the manufacturer attesting to the fact that the Tuflex floori covering material has been tested to ASTM E-648 with a crtical radiant flux not les than 0.8 cm2 and meets ASTM E-662 with a specific optical density not to exceed 450 in both flaming and non-flaming modes.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2003
Resolution: Completed. The floor material was removed becasue it did not meet the regulations.
Fire Fighting › Combustible Materials
Issued 5 December 2002
Resolved
Remove the Tuflex floor covering from the corridors and stairway enclosures. This floor covering does not meet the minimum requirements in Title 46 CFR, Part 72 and NVIC 9-97. LEGACY COMPONENT DESC: Primary Deck Coverings
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2003
Resolution: Combustible floor material has been removed from corridors and stairways.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 December 2002
Resolved
Prove the proper operatoin of the starboard stack vent fan louver that failed to automatically close during a test of the engine room's fixed CO2 system. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2003
Resolution: Observed satisfactory test.
Construction/Loadline › Hull
Issued 5 December 2002
Resolved
In #3 Port Water Ballast Tank, crop and renew as original, the fractured section of the deep-web frame where it intersects with the engine room's bulkhead. Repairs are to be completed to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2003
Resolution: Observed satisfactory repairs.
Electrical › Electric Supply System (service)
Issued 16 September 2002
Resolved
Install battery box strap on work boat. LEGACY COMPONENT DESC: Battery Installation
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 10 July 2003
Resolution: Observed satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 16 September 2002
Resolved
Repair aft steering CO2 (gen room) remote pull cable conduit at the CO2 bottles. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 8 May 2003
Resolution: Observed satisfactory.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 16 September 2002
Resolved
Install one each type BII or two each type BI fire ext. on rescue boat as per 46CFR 199.176.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 8 May 2003
Resolution: Observed satisfactory.
Construction/Loadline › Structures
Issued 16 September 2002
Resolved
Re-adjust all lower level water tight doors and repair gaskets. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 10 July 2003
Resolution: Observed satisfactory.
Engineering › Diesel Engine (auxiliary)
Issued 16 September 2002
Resolved
Repair fuel oil leak at emergency generator day tank supply line union.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 8 May 2003
Resolution: Observed satisfactory.
Engineering › Diesel Engine (auxiliary)
Issued 16 September 2002
Resolved
Port generator set - Find cause and repair high exhaust stack temperature alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 8 May 2003
Resolution: Observed satisfactory.
Lifesaving › Rescue Boat Equipment
Issued 16 September 2002
Resolved
Mark rescue boat with name of vessel and retro tape as per IMO rules. LEGACY COMPONENT DESC: Markings
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 8 May 2003
Resolution: Observed satisfactory.
Accommodation/Occupational Safety › Potable Water System
Issued 16 September 2002
Resolved
Support ice machine drain hose to create air gap between hose and drain. LEGACY COMPONENT DESC: Ice Machine
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 10 July 2003
Resolution: Observed satisfactory.
Lifesaving › Buoyant Apparatus
Issued 16 September 2002
Resolved
Mark liferings with ships name. LEGACY COMPONENT DESC: Life ring
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 8 May 2003
Resolution: Observed satisfactory.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 30 July 2002
Resolved
Install, then test in the presence of a USCG Marine Inspector, "an electrical control used to shut down the automatic auxiliary boiler in accordance with subpart 58.01-25" of CFR 46 ch.1. This device must stop the fuel supply to the fuel burning equipment. See 46 CFR Part 63.15-1(d) for gen. req.
Condition: Design Flaw
Due 30 September 2002
Resolved 16 September 2002
Resolution: Inspected and witnessed proper operation of fuel stop solnoid installed on boiler fuel oil system. Tested sat.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 30 July 2002
Resolved
Prior to operation of Aux boiler, provide an audible alarm corresponding to a flame failure condition.
Condition: Improper/Lack of Maintenance
Due 30 July 2002
Resolved 30 July 2002
Resolution: Replacement alarm installed and tested satisfactory.
Navigation › Collision/Grounding Avoidance
Issued 22 May 2002
Resolved
Due to sandblasting in progress, RADAR antennas were covered and RADAR masts were in the down position. LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2002
Resolution: RADAR HAS BEEN RETURNED TO FULL OPERATION
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 22 May 2002
Resolved
Make available both auxiliary boilers for test and inspection IAW 46 CFR Part 61.05.
Due 22 June 2002
Resolved 24 June 2002
Resolution: Conducted inspection of aux boiler. Other unit is only a hot water heater and not a boiler.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 26 February 2002
Resolved
Provide and install a self-closing device on the laundry room's door.
Condition: Unknown
Due 27 February 2002
Resolved 27 February 2002
Resolution: Self-closing installed and tested.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 February 2002
Resolved
Proivde on board a new (2002 Ed.) or corrected USCG Light List.
Condition: Improper/Lack of Maintenance
Due 27 February 2002
Resolved 27 February 2002
Resolution: Corrected USCG Light Listed proivded.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 26 February 2002
Resolved
Remove excess pain t stowage in compartment 2-19-0.
Condition: Placed in Improper Service
Due 27 February 2002
Resolved 27 February 2002
Resolution: Excess paint removed.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 26 February 2002
Resolved
Remove carpet pieces from fan spaces.
Due 27 February 2002
Resolved 27 February 2002
Resolution: Fan spaces cleared of carpet scraps.
Operations/Management › Drills/Instruction
Issued 26 February 2002
Resolved
Demonstrate for the USCG a satisfactory fire drill. LEGACY COMPONENT DESC: Fire
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2002
Resolved 22 May 2002
Resolution: Witnessed satisfactory fire drill.
Navigation
Issued 6 November 2001
Resolved
Prior to departure, align the navigation bridge and the local rudder angle indicator.
Condition: Unknown
Due 10 November 2001
Resolved 22 May 2002
Resolution: Observed satisfactory test of steering gear.
Fire Fighting
Issued 6 November 2001
Resolved
Prior to 12 December 2001, reconnect all self-closing devices on Class "A" fire doors.
Condition: Unknown
Due 12 December 2001
Resolved 22 May 2002
Resolution: All fire doors tested satisfactory.
Electrical
Issued 6 November 2001
Resolved
Properly adjust/align the emergency switchboard circuit breaker 3P.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Electrical
Issued 6 November 2001
Resolved
Prior to departure, make adjustments to the emergency generator diesel engine governor.
Condition: Unknown
Due 8 November 2001
Resolved 22 May 2002
Resolution: Witnessed satisfactory operation of emergency generator.
Fire Fighting
Issued 6 November 2001
Resolved
Prior to 12 December 2001, provide a duplicate fire control plan in a weather-proof container outside the deckhouse.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Electrical
Issued 16 May 2001
Resolved
Prove proper operation of the center generator's over-speed trip.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Engineering
Issued 16 May 2001
Resolved
Replace the faulty pressure relief valve fitted on the starting air lower air receiver.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Fire Fighting
Issued 20 March 2001
Resolved
Prior to 27 march 2001, make operable the self-closing decives installed onfire doors and remove all hold-back hooks in accordance with 46 CFR 72.05- 25(b)(9).
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Engineering
Issued 20 March 2001
Resolved
Prior to 27 March 2001, prove the proper operation of the fuel oil purifier's emergency shut-down in accordance with 46 CFR 111.103-9.
Condition: Unknown
Due 20 March 2001
Resolved 20 March 2001
Deck/Cargo
Issued 17 May 2000
Resolved
Replace hoisting cable on port workboat davit.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Lifesaving
Issued 17 May 2000
Resolved
Install reflective material to 8 ring buoys.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Accommodation/Occupational Safety
Issued 17 May 2000
Resolved
Make proper repair to forward emergency escape scuttle to ensure smooth operation.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Electrical
Issued 1 February 2000
Resolved
DURING INSPECTION OF CO2 SYSTEM, INSP. OBSERVED NEW WELDMENT ON P/S GENERATOR FOOT MOUNTS. [name withheld] MOUNTS REPAIRED BY SHIPS CREW. ISSUED CG-835 TO DETERMINE CAUSE AND SUBMIT PROPOSAL FOR REPAIR AND CORRECTION. GEN HOURS: P-13,467; STBD-13,380; CENTER-11,530.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Documentation
Issued 12 February 1996
Resolved
PROVIDE SATISFACTORY DOCUMENTATION THAT THE MARINE EMPLOYER HAS AN ESTABLISHED CHEMICAL TESTING PROGRAM AS IDENTIFIED IN 46 CFR PART 16.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Lifesaving
Issued 23 February 1994
Resolved
PROVIDE REQUIRED LIFERAFT PRIOR TO GETTING VESSEL UNDERWAY.
Condition: Unknown
Due 23 February 1994
Resolved 23 February 1994
Fire Fighting
Issued 23 February 1994
Resolved
TEST FIRE HOSES PRIOR TO GETTING VESSEL UNDERWAY.
Condition: Unknown
Due 23 February 1994
Resolved 23 February 1994
Fire Fighting
Issued 23 February 1994
Resolved
PERFORM ANNUAL TESTS AND SERVICE OF FIXED FIRE CO2 SYSTEMS.
Condition: Unknown
Due 23 February 1994
Resolved 23 February 1994
Lifesaving
Issued 23 February 1994
Resolved
HOLD REQUIRED DRILLS PRIOR TO GETTING VESSEL UNDERWAY.
Condition: Unknown
Due 23 February 1994
Resolved 23 February 1994
Engineering
Issued 1 March 1993
Resolved
PROVIDE ON BOARD AN APPROVED AUTOMATION PERIODIC TEST PROCEDURE.
Condition: Unknown
Due 1 March 1993
Resolved 1 March 1993
Navigation
Issued 1 March 1993
Resolved
REPLACE TEMP STEERING RAMS WITH PERM CYLINDERS AS NOTED ON ABS INTERIM CLASS CERTIFICATE.
Condition: Unknown
Due 1 March 1993
Resolved 1 March 1993
Fire Fighting
Issued 25 February 1993
Resolved
CONDUCT FIRE AND BOAT DRILLS PRIOR TO DEPARTING PORT OF PASCAGOULA, MS.
Condition: Unknown
Due 25 April 1993
Resolved 7 April 1993