MAURY USCG vessel records Sign in
← All vessels

GASCHEM TANA

GASCHEM TANA is a 1992 tank ship. The Coast Guard has recorded 29 inspections since 1993, most recently in January 2012, along with 7 deficiencies and 8 operational controls.

Records from 1993 to 2012. Most recent: inspection, 19 January 2012.

Built
1992
Last inspected
19 January 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9010797 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
383736
Flag
LIBERIA
—
Maury page id
psix-383736

Inspections, by type

…with no type recorded15
Years with a record 11 calendar years (1993–2012)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7082 - Convention (Subpart B), Gross Ton
2137 - Convention (Subpart B), Net Ton
13850 - Displacement, Ton
9436 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

19 January 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4225240
27 September 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3858265
16 September 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3851368
13 September 2010 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3846722
1 September 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3851358
13 January 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3663553
8 May 2008 Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3202286
3 December 2005 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · COC-GAS Renew · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2545095
2 December 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2544811
1 December 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2544532
12 April 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2332562
26 August 2004 ISPS II Exam · COC-GAS Annual
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2177660
21 March 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2029057
21 March 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2030179
31 January 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1998789
13 January 2004 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1986744
30 July 2003 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1855812
30 July 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1864091
22 May 2002 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1620467
20 May 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1618860
23 May 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 290788
23 May 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1066267
12 August 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 431630
5 August 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 431469
5 August 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1111108
20 January 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 387182
20 January 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 877137
30 April 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 357731
7 January 1993 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1141706

Deficiency record · 7

Lifesaving › Lifebuoys › Serviceable
Issued 30 July 2003 Resolved
Replace cracked and corroded ring buoys IWO focisle and port and starboard side of motor room.
Condition: Unknown
Due 6 August 2003
Resolved 26 August 2004
Documentation › Manifests/Lists
Issued 30 July 2003 Resolved
Provide muster list IWO accomondation spaces. LEGACY COMPONENT DESC: Muster List/Emergency Instructions
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2003
Resolution: Muster Lists posted in crew quarters on twon decks as per GL report dated 31JUL03
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 30 July 2003 Resolved
Provide information placard for MSD. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Unknown
Due 30 August 2003
Resolved 26 August 2004
Pollution Prevention/Response › Prevention Equipment
Issued 30 July 2003 Resolved
Prove proper operation of #3 cargo tank high pressure alarm.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2003
Resolution: Proper operation of the High Pressure Alarm was demonstrated as per GL statement dated 31JUL03
Electrical › Lighting (service)
Issued 30 July 2003 Resolved
Make all lighting fixtures intrinsically safe IWO motor room, compressor room, airlock, paint locker, and above # 2 & 3 cargo tanks. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2003
Resolution: Explosion Proof Lighting Fixtures were installed over Tank No. 1-P, port manifold, Tank No. 3-S, (2) in Electric Motor House, (3) inside Compressor House as per GL statement dated 31JUL03
Deck/Cargo
Issued 5 August 1999 Resolved
Provide/repair the audible alarms for the fixed gas detection system while the gas detection system is sampling in manual mode.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Electrical
Issued 5 August 1999 Resolved
Repair and prove operation of the manual start for the emergency generator or provide a second source of energy for 3 additional starts IAW SOLAS 74, ammended CH II-1, REG 44/2.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999

Ownership record