← All vessels
MSC SALVADOR
MSC SALVADOR is a 1997 freight ship. The Coast Guard has recorded 20 inspections since 2001, most recently in August 2006, along with 8 deficiencies and 7 operational controls.
Records from 2001 to 2006. Most recent: inspection, 28 August 2006.
- Built
- 1997
- Last inspected
- 28 August 2006
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9155092 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2OL2
38382
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-38382
Inspections, by type
…with no type recorded7
Years with a record
6 calendar years (2001–2006)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it29115 - Regulatory (Subpart C or D), Gross Ton
17030 - Regulatory (Subpart C or D), Net Ton
400997 - Dead Weight, Ton
511104 - Displacement, Ton
17030 - Regulatory (Subpart C or D), Net Ton
400997 - Dead Weight, Ton
511104 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
28 August 2006
Annual Inspection · Ballast Water Examination · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2761784
19 November 2005
ISPS II Exam · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2537482
7 May 2005
Ballast Water Examination · PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2351567
3 January 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2267688
18 November 2004
PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2243384
18 November 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2244111
18 November 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2244537
11 August 2004
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2162782
27 July 2004
ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2146424
13 June 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2096538
12 June 2004
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2095838
28 April 2004
Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2054381
26 January 2004
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1992559
23 January 2004
Periodic Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1991690
20 January 2004
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1988592
8 October 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1923733
4 September 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1922409
24 March 2003
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1761847
26 March 2002
Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1597586
28 October 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 295101
Deficiency record · 8
Electrical › Electrical Distribution System (emergency) › Junction Box
Issued 28 August 2006
Resolved
Exposed cables at Junction box # P-EL-70
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 August 2006
Resolved
Handrail loose on emergency generator
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 18 November 2004
Resolved
Vessel does not have an echo depth sounder recorder. Have echo depth sounder recorder installed w/in 30 days to the satisfaction of class.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 November 2004
Resolved
Vessels sedondary marine radar not functioning properly. Vessel was granted a departure LODto go to Baltimore, where they must have repairs made.
Navigation › Piloting/Steering › Gyro Compass
Issued 13 June 2004
Resolved
Received request for LOD 11 Jun 04 due to loss of ship's gyro compass. Issued LOD.
13 Jun 04: Received technician's report attesting to proper repair and operation.
Engineering › Freshwater System (cylinder head cooling)
Issued 28 April 2004
Resolved
Soft patch on small cooling line that branches off of main cooling line on stbd side lower engine room. Repair to the satisfaction of Class Society Surveyor. LEGACY COMPONENT DESC: Piping
Lifesaving › Launching Appliances
Issued 28 April 2004
Resolved
Observed port lifeboat remote launching cable only long enough to bring lifeboat to deck. Checked plans which differ from current set up. Class to test remote cable and determine proper length required to safely launch & release lifeboat from ship. Cable can not hold the brake control in the off p LEGACY COMPONENT DESC: Remote Cable
Fire Fighting › Miscellaneous Items
Issued 28 April 2004
Resolved
Class Surveyor to atest to the proper placement of EEBD'S and update fire control plans ( & stamp ) showing EEBD placement IAW Solas 74 LEGACY COMPONENT DESC: Fire Control Plans
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.