MAURY USCG vessel records Sign in
← All vessels

MSC SALVADOR

MSC SALVADOR is a 1997 freight ship. The Coast Guard has recorded 20 inspections since 2001, most recently in August 2006, along with 8 deficiencies and 7 operational controls.

Records from 2001 to 2006. Most recent: inspection, 28 August 2006.

Built
1997
Last inspected
28 August 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9155092 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-38382

Inspections, by type

…with no type recorded7
Years with a record 6 calendar years (2001–2006)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29115 - Regulatory (Subpart C or D), Gross Ton
17030 - Regulatory (Subpart C or D), Net Ton
400997 - Dead Weight, Ton
511104 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

28 August 2006 Annual Inspection · Ballast Water Examination · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2761784
19 November 2005 ISPS II Exam · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2537482
7 May 2005 Ballast Water Examination · PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2351567
3 January 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2267688
18 November 2004 PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2243384
18 November 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2244111
18 November 2004 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2244537
11 August 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2162782
27 July 2004 ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2146424
13 June 2004 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2096538
12 June 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2095838
28 April 2004 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2054381
26 January 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1992559
23 January 2004 Periodic Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1991690
20 January 2004 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1988592
8 October 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1923733
4 September 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1922409
24 March 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1761847
26 March 2002 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1597586
28 October 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 295101

Deficiency record · 8

Electrical › Electrical Distribution System (emergency) › Junction Box
Issued 28 August 2006 Resolved
Exposed cables at Junction box # P-EL-70
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 30 August 2006
Resolution: Cleared by Vessel''s Electrician
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 August 2006 Resolved
Handrail loose on emergency generator
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 30 August 2006
Resolution: Cleared by vessel''s Electrician
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 18 November 2004 Resolved
Vessel does not have an echo depth sounder recorder. Have echo depth sounder recorder installed w/in 30 days to the satisfaction of class.
Action required: 705 - Other - as specified
Due 18 December 2004
Resolved 7 December 2004
Resolution: Received report from Master of vessel stating that the echo sounding device complies with CFR regs.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 November 2004 Resolved
Vessels sedondary marine radar not functioning properly. Vessel was granted a departure LODto go to Baltimore, where they must have repairs made.
Action required: 705 - Other - as specified
Resolved 7 December 2004
Resolution: Received sat tech report from Baltimore.
Navigation › Piloting/Steering › Gyro Compass
Issued 13 June 2004 Resolved
Received request for LOD 11 Jun 04 due to loss of ship's gyro compass. Issued LOD. 13 Jun 04: Received technician's report attesting to proper repair and operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2004
Resolved 13 June 2004
Engineering › Freshwater System (cylinder head cooling)
Issued 28 April 2004 Resolved
Soft patch on small cooling line that branches off of main cooling line on stbd side lower engine room. Repair to the satisfaction of Class Society Surveyor. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 11 June 2004
Resolution: rcvd class report
Lifesaving › Launching Appliances
Issued 28 April 2004 Resolved
Observed port lifeboat remote launching cable only long enough to bring lifeboat to deck. Checked plans which differ from current set up. Class to test remote cable and determine proper length required to safely launch & release lifeboat from ship. Cable can not hold the brake control in the off p LEGACY COMPONENT DESC: Remote Cable
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 11 June 2004
Resolution: rcvd class report
Fire Fighting › Miscellaneous Items
Issued 28 April 2004 Resolved
Class Surveyor to atest to the proper placement of EEBD'S and update fire control plans ( & stamp ) showing EEBD placement IAW Solas 74 LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 11 June 2004
Resolution: rcvd class report

Ownership record