Records from 1993 to 2026. Most recent: inspection, 10 July 2026.
Inspection history · 85
10 July 2026
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8431821
9 February 2026
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8306066
19 January 2025
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8075112
3 January 2025
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8057181
13 December 2024
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8047035
11 November 2024
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8034075
29 March 2023
Deficiency Check · COI Inspection · Drydock Exam · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7659191
9 November 2022
Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7592085
20 December 2021
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7368101
24 December 2019
Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6878570
9 August 2019
Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6777873
10 October 2018
Examination of Repairs · COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6557378
8 February 2017
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6085935
7 January 2016
Examination of Repairs · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5791279
7 December 2015
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5776910
30 April 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5113741
11 November 2014
Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5021579
14 April 2014
MTSA Verification · Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4835880
31 March 2014
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4826680
31 March 2014
Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4826681
18 February 2014
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4800043
4 February 2014
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4793874
31 January 2014
Special
Type not classified · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4793060
1 February 2012
Damage Survey · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4235966
23 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4230157
18 September 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3888962
18 August 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3827497
12 August 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3827434
14 July 2010
Examination of Repairs · Cargo Tank Internal
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3831727
19 May 2010
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3738007
6 May 2009
Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3468625
20 April 2009
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3456918
22 February 2008
Internal Structural Exam · COI Inspection · MTSA Verification · Drydock Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3143653
13 October 2007
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3104636
12 August 2007
Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3026171
20 April 2007
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2908727
11 February 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2870484
6 April 2006
Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2618396
1 February 2005
Annual Inspection · MTSA Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2284717
20 January 2004
Examination of Repairs · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1978946
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1996518
29 December 2003
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1971590
29 December 2003
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2033934
22 July 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1854178
23 May 2003
Damage Survey · Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1802584
24 January 2003
COI Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1734569
19 February 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1486617
28 March 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1061305
1 March 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1376493
29 November 2000
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 646932
22 November 2000
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 191715
22 November 2000
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 223378
22 November 2000
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 760181
5 August 2000
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 821231
11 January 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1429268
2 March 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 800601
30 December 1998
Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 809927
14 September 1998
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 537988
31 August 1998
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 797678
30 August 1998
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 109388
20 April 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 789017
2 April 1998
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404544
14 January 1998
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 499900
5 April 1997
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 470994
26 March 1997
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1383479
12 February 1997
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 484153
6 January 1997
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 169307
19 July 1996
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 752825
14 July 1996
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 200455
28 March 1996
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1458287
4 March 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 447098
4 February 1996
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 457776
19 December 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 68542
16 June 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 489658
29 March 1995
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 832149
2 December 1994
Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1179813
30 November 1994
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 3925
29 November 1994
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 526690
29 November 1994
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1177385
10 July 1994
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 159752
23 June 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1330116
2 June 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1012268
24 February 1994
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1165118
17 June 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 479985
9 April 1993
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1401693
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 December 2024
Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society.
Vessel was involved in an allision while transitting near Kinder Morgan Deer Park.
Vessel must conduct survey of effected spaces and conduct any necessary permanent repairs at next drydock to the satisfaction of attending Coast Guard Marine Inspector.
46CFR32.60-1(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 January 2025
Resolution: Repairs complete.
Construction/Loadline › Structures › Trunk
Issued 11 November 2014
Resolved
Barge sustained an approximate 1/8" - 1/4" hole to the raise trunk of the #3 cargo tank IVO of the port-aft side shell approximately 22" above the walking deck. 18" x 18" plate insert to be fitted.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 November 2014
Resolved 12 November 2014
Resolution: Examined final weld repair and witness satisfactory air test. Discrepancy cleared and barge is authorized back-in-service.
Construction/Loadline › Structures › Deck Plating
Issued 31 March 2014
Resolved
Vessel's #3 cargo tank top, located aft midship centerline and adjacent to the aft raised cargo tank trunk was found to have a small one inch hairline fracture causing VGO to weep from it.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 April 2014
Resolution: Cropped and renewed one 3''x2''x3/8" and one 2''x18"x3/8"on #3 center cargo tank. Conducted a visual exam of all repairs and witnessed air test at 2 PSI. Test satisfactory.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 31 January 2014
Resolved
Vessel to proceeded to U.S.E.S at Devall fleet to clean spilled cargo from deck and containment area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2014
Resolution: Vessel proceeded to U. S. E. S. at Devall fleet and spilled product was removed out of deck containment to vac trucks. Pollution responders and Marine Inspectors verified removal of product and cleared deficiency.
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 31 January 2014
Resolved
Vessel to prove proper capacity and loading procedures of #3 center cargo tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2014
Resolution: Vessel provided gauging reports, strapping tables and tank max tank capacity for the #3 center cargo tank. Results were calculated and verified by Marine Inspector. Deficiency was cleared.
Construction/Loadline › Structures › Trunk
Issued 23 January 2012
Resolved
Vsl has approximately 3" fracture on centerline of raised trunk on stern of vsl (where raised trunk & deck meet). Vsl is to make perm repairs to satisfaction of local [name withheld] is currently unloaded . 835 Issued. No further cargo ops permitted until perm repairs are made.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2012
Resolved 1 February 2012
Resolution: Vessel has C/R 24" X 24" repaire on stern of cargo tank dome air tested satisfcatory.
Construction/Loadline › Hull › Hull Plating
Issued 20 April 2009
Resolved
3" fracture in stbd side bow rake along deck knuckle
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 June 2009
Resolved 6 May 2009
Resolution: Repaired 3" verticle fracture in stbd bow corner wrapper at deck knuckle.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 12 August 2007
Resolved
Shift barge, along with CBC 326 & CBC 333 to Bayou Fleet, LMR 125 RDB. Offload sufficient cargo to T/B CBC 326, using cargo pump on CBC 333, to lower cargo level below leaking drain valve on discharge system. Then, proceed to Marathon, Garyville facility (LMR 140) offload remainder of cargo. Finally, proceed to TT 104 to make permanent repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 12 August 2007
Resolved
Make permanent repairs to leaking drain valve on discharge system to the satisfaction of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2007
Construction/Loadline › Hull
Issued 29 December 2003
Resolved
Prior to Re-load Vessel permitted to proceed to Texas City trans oil to offload present cargo of asphalt. Proceed to repair yard and effect permanent repairs to 1'x16' inset and all IWO port aft midbody side shell to the satisfaction of attending CG Marine Inspector. LEGACY COMPONENT DESC: Double Hull
Action required: 705 - Other - as specified
Resolved 20 January 2004
Resolution: 16'' of port gunwale renewed.
Engineering
Issued 1 March 2001
Resolved
PROPERLY MOUNT AND SECURE LOOSE CARGO PUMP ENGINE GAUGES.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Construction/Loadline
Issued 1 March 2001
Resolved
MAKE ALL SIDES OF EXTERNAL HULL VISIBLE FOR INSPECTION.
Condition: Unknown
Due 1 March 2001
Resolved 1 March 2001
Construction/Loadline
Issued 5 August 2000
Resolved
Make permanent repairs to port stern cavel torn from deck. To be completed to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Deck/Cargo
Issued 2 March 1999
Resolved
Remove or secure loose grating around machinery.
Condition: Unknown
Due 2 March 1999
Resolved 4 March 1999
Deck/Cargo
Issued 2 March 1999
Resolved
Replace two flame screens holed during removal for inspection.
Condition: Unknown
Due 2 March 1999
Resolved 4 March 1999
Deck/Cargo
Issued 30 December 1998
Resolved
MAKE #3 CARGO TANK AVAILABLE FOR INSPECTION FOR USCG MARINE INSPECTOR TO DETERMINE REPAIRS TO BE MADE TO. CARGO OPS ARE NOT TO BE CONDUCTED UNTIL SATISFACTORY REPAIRS ARE MADE AND TESTED.
Condition: Unknown
Due 31 December 1998
Resolved 1 January 1999
Deck/Cargo
Issued 2 April 1998
Resolved
PROVIDE DOCUMENTATION OF APPROVAL FOR CARGO PUMP/PIPING MODIFICATIONS.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Engineering
Issued 2 June 1994
Resolved
TEST ALL THERMAL FLUID HEATER ALARMS AND SHUTDOWNS FOR AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994