Records from 1993 to 2023. Most recent: inspection, 7 December 2023.
Inspection history · 35
7 December 2023
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7836194
10 November 2022
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7590461
10 December 2021
Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7365996
18 January 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7121769
11 November 2019
DAPI Audit · Annual Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6848546
27 November 2018
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6581567
9 November 2017
COI Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6299661
14 November 2016
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6033162
7 December 2015
Hull Examination · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5772499
17 August 2015
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5219011
22 October 2014
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5009888
16 February 2011
Type not recorded
No type recorded · Marine Safety Center (MSC) · Activity 3983576
14 January 2011
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3926559
2 November 2010
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3883789
5 February 2009
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3416122
23 December 2008
Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3385777
23 April 2007
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2914579
10 November 2005
Administrative Inspection · Simplified Stability Test · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2549404
24 November 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2249148
20 April 2004
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2048370
18 December 2003
Hull Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1966609
5 December 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1718523
28 February 2002
Type not recorded
No type recorded · Station Crystal River · USCG Southeast District (CGD-SE) · Activity 1498214
24 January 2002
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1485765
13 December 1999
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1376011
5 December 1998
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1375582
5 January 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 775483
25 July 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 781848
13 December 1996
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1434498
2 November 1995
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1184469
15 November 1994
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175446
8 December 1993
Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1159750
4 May 1993
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 693090
20 April 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 692853
7 January 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 690788
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 December 2023
No resolution recorded
The owner or managing operator shall make a vessel available for drydock examinations and internal structure examinations for certification. Vessel has lapsed the drydock and internal structure exam expiration dates, 30NOV2023, on its COI. Allow inspection for satisfactory drydock and internal structure exam credit prior to the carriage of passengers. - 46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2023 — due date passed with no resolution recorded
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 1 December 2022
Resolved
Employers must maintain records of chemical tests. Vessel master's proof of consortium enrollment had recently expired, 30NOV22.
Obtain valid proof of consortium enrollment.
46 CFR 16.260
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 22 December 2022
Resolution: Received updated consortium enrollment documentation for vessel master.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 December 2022
Resolved
The number and identification of stowed life jackets, and their sizes, must be clearly marked by letters and numbers of at least 2 inches in height.
46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 22 December 2022
Resolution: Received photo evidence of new lifejacket stowage markings.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 December 2022
Resolved
Remote fuel shut off stations must be marked in letters at least 1 inch high, indicating purpose of valve and direction of operation.
Provide conspicuous labeling for fuel line quick disconnect.
46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 22 December 2022
Resolution: Received photo evidence of new fuel shut-off valve location markings.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 1 December 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights.
Outfit vessel with two working flashlights.
46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 22 December 2022
Resolution: Received photo evidence of two working portable lights onboard vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 November 2022
Resolved
A Certificate of Inspection is valid for 5 years.
Complete COI renewal prior to carriage of passengers.
COI expired on 09NOV22.
46 CFR 176.107 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 November 2022
Resolved 1 December 2022
Resolution: Completed satisfactory inspection of vessel and issued new COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 December 2021
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel has lapsed on its drydock/ISE dates.
46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2022
Resolved 11 January 2022
Resolution: Completed dry dock examination.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 November 2018
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
Five adult lifejackets were unserviceable. Replace with approved type. Passenger count is reduced to 07 passengers. - 46CFR180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 27 November 2018
Resolution: Owner replaced lifejackets with type approved lifejackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 November 2018
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer’s policy regarding drug and alcohol use in the workplace.
Owner had no record of signed substance abuse policy for each employee as required by program. Provide record of signed policies for each employee to USCG. - 46CFR16.401(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 28 November 2018
Resolution: Vessel owner submitted signed records of substance abuse polucy for each employee.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 November 2018
Resolved
An EAP training program must be conducted for the employer’s crewmembers and supervisory personnel. The training program must include at least the following
elements: the effects and consequences of drug and
alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer’s supervisory personnel. Supervisory personnel must receive at least 60 minutes of training.
Owner had no record of training for crewmembers or supervisor. Provide record of training to USCG. - 46CFR16.401(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 28 November 2018
Resolution: Owner submitted record of training for crewmembers and supervisor.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 November 2018
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Letters and numbers must be at least 50 millimeters (2 inches) high.
Markings are faded or missing. Replace. - 46CFR185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 11 December 2018
Resolution: Owner re-stenciled markings for nubmer and size of lifejackets on containers.
Construction/Loadline › Structures › Superstructure
Issued 9 November 2017
Resolved
Provide door with securing device to outboard engine. 46CFR177.900
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2017
Resolved 13 November 2017
Resolution: Locking device provided for door to the satisfaction of the Marine Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 November 2017
Resolved
Secure portable fire extinguisher. 46CFR181.500
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Resolution: Secured portable fire extinguisher to the satisfaction of the Marine Inspector.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 November 2017
Resolved
Label bags for adult and child PFDs. 46CFR180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Resolution: Labeled bags for adult and child PFDs to the satisfaction of the Marine Inspector.
Fire Fighting › Fire Bucket › Stenciling
Issued 9 November 2017
Resolved
Label fire buckets. 46CFR181.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Resolution: Labeled fire buckets to the satisfaction of the attending Marine Inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 14 November 2016
Resolved
Obtain additional B-II fire extinguisher for accommodation space IAW 46 CFR 181.30-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2016
Resolution: Vessel o/o purchased new fire extinguisher
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 November 2016
Resolved
Replace two lifejackets and reduce passengers by two IAW 46 CFR 180.71
Due 1 December 2016
Resolved 14 November 2016
Resolution: O/o replaced the two failed lifejackets with two new lifejackets.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 November 2016
Resolved
Repair cracked welds in diving ladder IAW 46 CFR 176.25-50
Due 14 December 2016
Resolved 14 November 2016
Resolution: O/o repaired cracked welds in ladder by welding.
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 7 December 2015
Resolved
Vessel must prove functionality of propulsion machinery and get underway to conduct drills IAW 46 CFR 185.520.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2015
Resolution: Vessel proved functionality of propulsion machinery.
Fire Fighting › Fire Bucket › Stenciling
Issued 7 December 2015
Resolved
03 Fire Buckets must be provided and labeled IAW 46 CFR 181.610.
Due 7 January 2016
Resolved 15 December 2015
Resolution: Fire Buckets provided and labeled.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 December 2015
Resolved
Lifejacket stowage must be labeled with proper number of child and adult lifejackets IAW 46 CFR 185.604.
Due 7 January 2016
Resolved 15 December 2015
Resolution: Lifejackets labeled with proper number of child and adult.
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 December 2015
Resolved
Remote fuel shutoff valves must be marked indicating purpose and direction of operation IAW 46 CFR 185.608.
Due 7 January 2016
Resolved 15 December 2015
Resolution: Remote fuel shutoff valves marked.
Lifesaving › Hand Flares › Storage
Issued 7 December 2015
Resolved
Portable watertight containers of a bright color must be provided for distress signals IAW 46 CFR 185.614.
Due 7 January 2016
Resolved 15 December 2015
Resolution: Portable watertight containers for distress signals provided.
Construction/Loadline › Hull › Weld
Issued 7 December 2015
Resolved
Repair cracks on front of starboard pontoon and stern of port pontoon IAW 46 CFR 176.610.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2015
Resolution: Repaired cracks on starboard pontoon and port pontoon.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 April 2007
Resolved
Submit 2006 MIS report.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2007
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 24 April 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 10 November 2005
Resolved
Provide a company policy letter indicating MRO drug free determination before employees return to work.
Action required: 705 - Other - as specified
Due 28 November 2005
Resolved 20 June 2006
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 10 November 2005
Resolved
Provide proof of pre-employment testing for employees that work in a safety sensitive position.
Action required: 705 - Other - as specified
Due 28 November 2005
Resolved 20 June 2006
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 10 November 2005
Resolved
Provide proof of that the MIS report was submitted.
Action required: 705 - Other - as specified
Due 28 November 2005
Resolved 20 June 2006
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 10 November 2005
Resolved
Provide proof of training of employees and EAP training of Masters.
Action required: 705 - Other - as specified
Due 28 November 2005
Resolved 20 June 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 24 January 2002
Resolved
Mount fire extinguisher in an appropriate mounting bracket. Corrected prior to completion of the inspection.
Due 24 January 2002
Resolved 24 January 2002
Lifesaving
Issued 5 December 1998
Resolved
RENEW UNSERVICEABLE RING BUOY.
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Lifesaving
Issued 5 December 1998
Resolved
REPAIR TWO LIFE PRESERVERS, ONE SEW UP TEAR IN CLOTH, SECOND RENEW RETROREFLECTIVE TAPE.
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Lifesaving
Issued 5 December 1998
Resolved
RENEW FOUR (04) UNSERVICABLE LIFE PRESERVERS.
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Accommodation/Occupational Safety
Issued 13 December 1996
Resolved
INSTALL THREE (3) RETAINING CHAINS AT BOW ACCESS TO PASSENGER AREA.
Condition: Unknown
Due 20 December 1996
Resolved 23 December 1996
Lifesaving
Issued 13 December 1996
Resolved
INSTALL REFLECTIVE TAPE ON LIFE RING.
Condition: Unknown
Due 20 December 1996
Resolved 23 December 1996
Fire Fighting
Issued 13 December 1996
Resolved
INSTALL BRACKET FOR PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 20 December 1996
Resolved 23 December 1996
Lifesaving
Issued 13 December 1996
Resolved
INSTALL BRACKET FOR LIFE RING AND WATERLIGHT.
Condition: Unknown
Due 20 December 1996
Resolved 23 December 1996