Records from 1993 to 1999. Most recent: inspection, 23 March 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Unknown
Issued 6 August 1998
No resolution recorded
REPLACE ALL FOREIGN WORKERS WITH PROPERLY TRAINED AND QUALIFIED U.S. EMPLOYEES AS PER 33 CFR 141.15.
Condition: Unknown
Due 8 August 1999 — due date passed with no resolution recorded
Construction/Loadline
Issued 27 February 1998
Resolved
Repair all ventilation closures and/or fire dampers as noted on DNV survey deficiency report.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Accommodation/Occupational Safety
Issued 27 February 1998
Resolved
Repair port mud pit supply fan.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 27 February 1998
Resolved
Repair emergency ventilation shutdowns on shaker room exhaust fan and mud pit exhaust fan.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Documentation
Issued 27 February 1998
No resolution recorded
Provide copy of DNV approved Operation Manual latest revision (copy of approved cover letter need only be provided to CG).
Condition: Unknown
Due 12 September 1998 — due date passed with no resolution recorded
Documentation
Issued 27 February 1998
Resolved
Provide copies of latest Code of Federal Regulations (CFRs) on board: 33 CCFR Part 1-124, 33 CFR Parts 125-199, 46 CFR Parts 90-139.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Documentation
Issued 27 February 1998
No resolution recorded
Provide copy of final DNV report indicating all items on DNV deficiency list completed.
Condition: Unknown
Due 12 September 1998 — due date passed with no resolution recorded
Engineering
Issued 27 February 1998
Resolved
Provide onboard fuel oil transfer procedures that meet: 33 CFR 155.720, 730, 740 and 750.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Fire Fighting
Issued 27 February 1998
Resolved
Provide documentation that unit's training program and drills meet the requirements of 46 CFR 109.213.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 27 February 1998
Resolved
Reinstall missing rubrails on stbd fwd lifeboat.
Condition: Unknown
Due 12 September 1998
Resolved 13 August 1998
Construction/Loadline
Issued 27 February 1998
Resolved
Repair and prove proper operation of following in stbd pump room: a) high level bilge alarm sensor; b) watertight door closing strobe light.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Accommodation/Occupational Safety
Issued 27 February 1998
Resolved
Replace missing handrails on port and stbd aft blister tops.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Accommodation/Occupational Safety
Issued 27 February 1998
Resolved
Provide documentation from recent test(s) that potable water in 3rd deck quarters area is safe for drinking.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 27 February 1998
Resolved
Provide a more dependable starting system for rescue boat, i.e., new starting batteries and/or continuous trickle battery charger.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Navigation
Issued 27 February 1998
Resolved
Ensure all obstruction light (four corners) are properly flashing (60 flashes per minute; all flashing in unison).
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 27 February 1998
Resolved
Prove proper operation (starting) of aft rescue boat.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Construction/Loadline
Issued 27 February 1998
Resolved
Repair and prove proper operation of following in port pump room: a) low level bilge alarm sensor; b) watertight door closing strobe light.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 27 February 1998
Resolved
provide properly fitting davit securing brackets for #1 (stbd) fwd) lifeboat.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Navigation
Issued 27 February 1998
Resolved
Provide proper operation of remaining inoperative obstruction light.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 27 February 1998
Resolved
Prove proper operation of mud pit room and mud shaker area loss-of- ventilation alarms.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 27 February 1998
Resolved
Provide self-closing door for mud pit room entrance.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Electrical
Issued 27 February 1998
Resolved
Remove all dead-end electrical cable in mud shaker room or properly terminate in explosion-proof junction boxes.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Engineering
Issued 27 February 1998
Resolved
Install 30 X 30 mesh flamescreens in all fuel oil vents where damaged or missing.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Deck/Cargo
Issued 27 February 1998
Resolved
Continue installing oil pollution containment around all fuel oil vents.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998