Records from 1993 to 2016. Most recent: inspection, 26 November 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
26 November 2016
Ballast Water Examination · COE-Offshore · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6046542
26 November 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6048430
20 March 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5836924
23 July 2012
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4379606
14 March 2009
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3433243
30 December 2004
PII Safety Exam · ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2266439
6 April 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2038437
10 February 2004
Annual Inspection · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2002765
16 December 2003
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1964891
19 January 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1732469
19 April 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1606531
21 March 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1495921
20 February 2002
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1487837
17 April 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 289242
17 April 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 276821
15 November 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 422903
17 October 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 421663
15 November 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 384945
6 October 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 383479
15 March 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 376162
13 February 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 656908
8 February 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 374984
30 October 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 371877
11 January 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 516411
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 July 2012
Resolved
1530-Radar- Ships 500 gross tonnage and upwards shall be fitted with a radar installation that shall be capable of operating in the 9Hhz frequency band. PSCO observed that one x-band radar is inoperable and is being attended by a technician. Vessel must provide a technician report attesting to its proper operation. Cite: SOLAS 74 (2009 Con. Ed.) V/12
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 3 August 2012
Resolution: Received, reviewed, accepted tech report from Mackay attesting to the proper operation of the radar.
Construction/Loadline › Markings › Load Line Mark
Issued 30 December 2004
Resolved
Deck line was not on starboard side of hull. Classification society (BV) must summit report addressing deck line prior to next US port.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 March 2009
Resolution: Deck line mark permanently displayed.
Engineering › Generator (propulsion-electric)
Issued 16 December 2003
Resolved
THE ELBOW ON THE SEA WATER SUPPLY LINE FOR THE #2 SHIPS SERVICE GENERATOR IS LEAKING. A SOFT PATCH IS CURRENTLY IN PLACE. SOLAS 74/78 CH II-1/REG 26. CORRECT PRIOR TO DEPARTURE AND TO CLASS OR COAST GUARD SATISFACTION. LEGACY COMPONENT DESC: Sea Water Supply Line
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2003
Resolved 17 December 2003
Resolution: ELBOW ON THE SEA WATER SUPPLY LINE TO GENERATOR REPLACED. DEFICIENCY CLEARED.
Navigation
Issued 20 February 2002
Resolved
B.A. LIGHT LIST VOL. J MISSING CORRECTIONS 46/00 - 22/01 LEGACY COMPONENT DESC: PUBLICATIONS
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2002
Resolution: RECEIVED FAXED RECEIPT OF PURCHASE OF NEW LIGHT LIST AND NOTICE TO MARINERS.
Construction/Loadline › Markings
Issued 20 February 2002
Resolved
LOAD LINE NOT PERMANENTLY AFFIXED. LEGACY COMPONENT DESC: Load Line Mark
Action required: 15 - Rectify deficiencies by next port
Resolved 21 March 2002
Resolution: Load line marked.
Construction/Loadline
Issued 17 October 1998
Resolved
Prior to 01NOV98, properly mark loadline deck reference line located port side.
Condition: Unknown
Due 23 November 1998
Resolved 23 November 1998
Documentation
Issued 17 October 1998
Resolved
Prior to entering US waters provide Cargo Securing Manual approval letter.
Condition: Unknown
Due 23 November 1998
Resolved 23 November 1998
Lifesaving
Issued 17 October 1998
Resolved
Prior to 01NOV98, provide an electrical insulation mat for emergency generator compartment.
Condition: Unknown
Due 23 November 1998
Resolved 23 November 1998
Lifesaving
Issued 17 October 1998
Resolved
Upon arriving to next US port of call, conduct fire and abandon ship in thepresence of a US Coast Guard inspector.
Condition: Unknown
Due 23 November 1998
Resolved 23 November 1998
Lifesaving
Issued 6 October 1995
Resolved
TWO LIGHTS FOR VESSELS LIFE RINGS WERE INOPERABLE (SOLAS 74, CH.III, REG 9.1).
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Lifesaving
Issued 6 October 1995
Resolved
VESSELS HYDROSTATIC RELEASE FOR THE EPIRB WAS EXPIRED (SOLAS 74, CH III, REG. 9.1). CORRECTION IS REQUIRED PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Lifesaving
Issued 15 March 1995
Resolved
Classification society representative to verify davit falls on port lifeboat, using necessary inspection or strength test, are adequate for theservice intended.
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Fire Fighting
Issued 15 March 1995
Resolved
Remove all non-remote controlled holdback hooks to fire screen doors serving stairway.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Lifesaving
Issued 8 February 1995
Resolved
CONDUCT ABANDON SHIP DRILL IN PRESENCE OF CG MARINE INSPECTOR UPON ARRIVAL AT NEXT U.S. PORT.
Condition: Unknown
Due 9 February 1995
Resolved 24 March 1995
Navigation
Issued 8 February 1995
Resolved
COAST PILOT AND LIGHT LIST FOR AREA TRANSITNG NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 8 February 1995
Resolved 16 February 1995
Lifesaving
Issued 8 February 1995
Resolved
REPLACE BOTH PORT & STBD 12V LIFEBOAT BATTERIES (2 EA. BOAT) AND PROVE PROPER OPERATION OF LIFEBOAT MOTORS PRIOR TO DEPARTURE FROM PORT OF SAN JUAN P.R.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995