MAURY USCG vessel records Sign in
← All vessels

KUTAISI

KUTAISI is a 1976 tank ship. The Coast Guard has recorded 5 inspections in 1993, along with 6 deficiencies.

Records in 1993. Most recent: inspection, 22 January 1993.

Built
1976
Last inspected
22 January 1993
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7391604 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
383991
Flag
GEORGIA
—
Maury page id
psix-383991

Inspections, by type

…with no type recorded4
Years with a record 1 calendar year (1993)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 33 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it15661 - Regulatory (Subpart C or D), Gross Ton
7938 - Regulatory (Subpart C or D), Net Ton
23956 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

22 January 1993 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 655686
22 January 1993 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 655690
21 January 1993 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1397852
13 January 1993 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 655687
11 January 1993 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 459203

Deficiency record · 6

Construction/Loadline
Issued 21 January 1993 Resolved
Replace all missing guards on rotating machinery in pump room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 January 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 January 1993 Resolved
Properly stow portable fire extinguisher in pump room to ensure accessibility.
Condition: Unknown
Due 30 January 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 21 January 1993 Resolved
Repair explosion-proof light in pump room and replace guard around light.
Condition: Unknown
Due 30 January 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 21 January 1993 Resolved
Remove approximately 3 feet of oil/water in pump room bilges and have Marine Chemist recertify as gas free.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993
Deck/Cargo
Issued 21 January 1993 Resolved
Crop and renew cargo pump room piping in areas of temporary repairs (6) and(8) soft patches.
Condition: Unknown
Due 30 January 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 January 1993 Resolved
Repair/replace electrical outlet box on main deck, deck house, port side.
Condition: Unknown
Due 21 January 1993
Resolved 21 January 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.