MAURY USCG vessel records Sign in
← All vessels

MAPLE 3

MAPLE 3 is a 1992 tank ship. The Coast Guard has recorded 43 inspections since 1993, most recently in June 2014, along with 27 deficiencies and 7 operational controls.

Records from 1993 to 2014. Most recent: inspection, 24 June 2014.

Built
1992
Last inspected
24 June 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9034690 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
384006
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-384006

Inspections, by type

…with no type recorded21
Years with a record 16 calendar years (1993–2014)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it18360 - Convention (Subpart B), Gross Ton
5508 - Convention (Subpart B), Net Ton
19632 - Dead Weight, Metric Ton
29697 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 43

24 June 2014 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4898261
21 June 2014 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4896878
6 June 2014 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4880923
9 May 2012 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4311487
23 February 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3950683
14 December 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3910440
1 November 2010 COC-GAS Renew
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3882064
4 December 2009 COC-GAS Annual · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3644667
27 July 2009 PII Safety Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3547157
13 March 2009 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3432757
7 November 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3359093
4 November 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3356866
30 October 2008 ISPS II Exam · COC-GAS Renew · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3354133
20 June 2008 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3242184
8 May 2008 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3201637
6 May 2008 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3199957
26 November 2007 Ballast Water Examination · COC-GAS Annual · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3104849
1 April 2007 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2899198
28 February 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2879557
10 October 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2798205
23 September 2006 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2785072
5 June 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2671092
19 September 2005 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2495119
17 September 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2495190
13 September 2005 Type not recorded
No type recorded · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2491144
18 August 2004 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2170392
25 September 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 802216
23 September 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 420766
23 September 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 421063
15 May 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1106231
2 April 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 389545
24 February 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 375583
24 February 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 856420
9 November 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 534897
11 July 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1177366
3 June 1994 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1013248
26 May 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 367078
18 April 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467414
28 September 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1154282
21 August 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 479372
17 August 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 360171
13 August 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 841936
21 February 1993 Deficiency Check · Certificate of Compliance
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1147315

Deficiency record · 27

Navigation › Collision/Grounding Avoidance › Radar
Issued 23 February 2011 Resolved
The Radar was reported not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2011
Resolved 23 February 2011
Resolution: Received, reviewed and accepted tech report from [name withheld] stating the Radar was repaired, tested and found satisfactory.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 December 2010 Resolved
Secondary marine radar inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2010
Resolution: Received class report attesting to repair of x-band radar.
Navigation › Collision/Grounding Avoidance › Radar
Issued 1 November 2010 Resolved
1530 - Radar-Vessel is required to have a long range radar (X-band). Vessels X-band radar is inoperable. Site: 33CFR164.37(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2010
Resolution: Vessel had service engineer come onboard and fix the X-band radar. Tested satisfactorily to the attending PSCO and Class. Deficiency cleared.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 1 November 2010 Resolved
1850 - Fire Protection Cargo Deck Area - Vessel is required to have a Sea Water Spray Sprinkler System in protected areas. Vessel had approximately 25 nozzles over various critical deck areas not working properly. Site: 46CFR1105
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2010
Resolution: Vessel dismantled and cleared the nozzles and pipes of the Sea Water Spray Sprinkler System. Class inspected and tested the Sea Water Spray Sprinkler System satisfactorily. Deficiency cleared.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 1 November 2010 Resolved
1499 - Other (Prop & Aux Machinery) - Vessels generating sets shall be capable of providing for electrical services if any one generator is out of operation. Vessels third generator is inoperable. Site: SOLAS74 (97 cons ed.) Ch. II-I. Reg. 41.1.4.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2010
Resolution: Vessel submitted Class Report issuing a Condition of Class for the vessels third generator. The other two generators (No. 1 and 2.) were tested satisfactorily. Condition of Class imposed for No. 3 generator due 31DEC10. Deficiency cleared.
Lifesaving › Launching Appliances › Release Mechanism
Issued 27 July 2009 Resolved
0610 - Lifeboat - Vessel was unable to launch freefall lifeboat due to improper instillation of the primary and emergency hydraulic oil pump lines. See attached Form A and B inspection forms found in certificates. SOLAS 74 consed 2004 Ch. III Reg. 20.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2009
Resolution: Received technicians report and class report attesting to the temporary repair of the lifeboat release mechanism.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 November 2008 Resolved
Vessel reported inoperable x-band radar.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 January 2009
Resolved 13 March 2009
Resolution: Master provided PSCO''s a copy of a technician report stating that both radars had old magnetron''s removed, and replaced with new equipment. The technician carried out setup and tested with satisfactory results.
Fire Fighting › Fire Hoses › Condition
Issued 30 October 2008 Resolved
0720 - Fire fighting appliances - The Dry chemical hoses were found to be chaffed showing damaged metal jacketing for the hose. Repiar/Replace to the satisfaction of Class Prior to departure. SOLAS 74 (2004) Ch VII Reg13.1/ IGC Code Ch11.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2008
Resolution: Class report received via email to Sector [name withheld] attesting to one new dry chemical hose in place and other hoses ordered but being held by Customs forclearance. If not cleared by departure, the hoses will be forwarded to the next port for delivery.
Construction/Loadline › Hull › Weld
Issued 20 June 2008 Resolved
Observed a 10' fracture, that has been temporarily repaired, located apparently frame 90, starboard side, extending upward from the waterline, Class Society Surveyor to recommend/ attest to proper repairs.
Action required: 705 - Other - as specified
Due 24 June 2008
Resolved 24 June 2008
Resolution: Recieved class report received. Surveyor stated that no damage or signs of temporary repairs were noted.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom Ventilation
Issued 26 November 2007 Resolved
Ventilation in Electric motor room and adjoining air lock space is inadequate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 December 2007
Resolved 11 December 2007
Resolution: Recvd class report; air inlet damper made to maintain positive pressure in space
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 26 November 2007 Resolved
Vessel quick closing valves on port and stbd manifolds are not closing within 30 second time requirement.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2007
Resolution: recvd class report; valve actuators have been adjusted to decrease closing time.
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 23 September 2006 Resolved
The vessel does not meet it's safe manning certificate. The vessel's second mate does not have a valid flag state endorsement.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2006
Resolved 26 September 2006
Resolution: Received a valid flag state endorsement for the second mate.
Deck/Cargo › Cargo Refrigeration › General
Issued 23 September 2006 Resolved
The vessel's Cargo Compressor room was not certified safe for workers. The CG marine inspectors were unable to inspect the Cargo Compressor room. The vessel's Cargo Compressor room must be inspected prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2006
Resolved 2 October 2006
Resolution: CG Marine Inspector inspected the vessel''s Cargo Compressor room, and found it to be satisfactory.
Deck/Cargo › Cargo Stowage › General
Issued 19 August 2004 Resolved
The vessel's Procedures and Arrangements Manual does not address the carriage of Diethyl Ether, Ethylamine, MTBE, or Pentane as permitted by the NLS Certificate.
Action required: 705 - Other - as specified
Due 7 September 2004
Resolved 20 August 2004
Resolution: Received class report. Cleared deficiency.
Deck/Cargo › Cargo Stowage › General
Issued 19 August 2004 Resolved
Provide Class approval of the MARV settings prior to loading any cargo in U.S. waters.
Action required: 705 - Other - as specified
Due 19 August 2004
Resolved 20 August 2004
Resolution: Received class report. Cleared deficiency.
Deck/Cargo
Issued 23 September 1998 Resolved
REPAIR & DEMONSTRATE PROPER OPERATION OF DECK TANK QUICK CLOSING VALVE ON VAPOR LINE.
Condition: Unknown
Due 25 September 1998
Resolved 2 October 1998
Deck/Cargo
Issued 23 September 1998 Resolved
PROVIDE BATTERIES FOR PORTABLE OXYGEN METER, DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 25 September 1998
Resolved 2 October 1998
Engineering
Issued 23 September 1998 Resolved
RENEW BONDING STRAP & SECURE ELECTRICAL CONNECTIONS ON MOTOR FOR NO.1 LUBE OIL PURIFIER.
Condition: Unknown
Due 25 September 1998
Resolved 2 October 1998
Engineering
Issued 23 September 1998 Resolved
RENEW BONDING STRAP ON #2 BALLAST PUMP.
Condition: Unknown
Due 25 September 1998
Resolved 2 October 1998
Deck/Cargo
Issued 23 September 1998 Resolved
PROPERLY INSTALL MANUAL SHUT OFF VALVE HANDLE ON NO. 2 STARBOARD CARGO TANKGAUGING SYSTEM, ENSURE HANDLE DOES NOT GOUGE INTO CARGO TANK TOP INSULATION.
Condition: Unknown
Due 25 September 1998
Resolved 2 October 1998
Deck/Cargo › Cargo Stowage › General
Issued 23 September 1998 Resolved
TEST CARGO PIPING SAFETY RELIEF VALVES TO SATISFACTION OF CLASSIFICATION SOCIETY. PROVIDE LOCAL COAST GUARD WITH SATISFACTORY CLASS SURVEYOR'S REPORT.
Condition: Unknown
Due 28 February 1999
Resolved 18 August 2004
Deck/Cargo
Issued 23 September 1998 Resolved
BLANK OFF OR PLUG UNUSED STUFFING TUBE ON BOTTOM OF ELECTRICAL JUNCTION BOXIN WAY OF #1 CARGO DOME.
Condition: Unknown
Due 25 September 1998
Resolved 2 October 1998
Electrical
Issued 23 September 1998 Resolved
PLUG OPENING ON SIDE OF EXPLOSION PROOF LIGHT FIXTURE IN PAINT LOCKER.
Condition: Unknown
Due 25 September 1998
Resolved 2 October 1998
Deck/Cargo
Issued 23 September 1998 Resolved
RENEW BONDING STRAP ON FORCED DRAFT VENTILATION FAN ON TOP OF ELECTRICAL MOTOR ROOM.
Condition: Unknown
Due 25 September 1998
Resolved 2 October 1998
Deck/Cargo
Issued 2 April 1996 Resolved
EMERGENCY SHUTDOWN FAILED TO OPERATE. REQUIRED PROPER OPERATION PRIOR TO CARGO DISCHARGE.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Deck/Cargo
Issued 3 June 1994 Resolved
DEMONSTRATE PROPER OPERATION OF VAPOR HIGH & LOW PRESSURE ALARMS PRIOR TO CARRIAGE OF PROPYLENE OXIDE IN U.S. WATERS.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Deck/Cargo
Issued 21 February 1993 Resolved
Isolate No. 1 starboard liquid manifold valve (14in) and demonstrate properoperation via air dump system to satisfaction of attending marine inspectorprior to ue in U.S. waters.
Condition: Unknown
Due 24 February 1993
Resolved 25 February 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.