BALTIC PEARL is a 1991 freight ship. The Coast Guard has recorded 29 inspections since 1993, most recently in January 2025, along with 5 deficiencies and 1 operational control.

Records from 1993 to 2025. Most recent: inspection, 21 January 2025.

Built
1991
Last inspected
21 January 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9008732 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
384286
Flag
BAHAMAS, THE
—
Maury page id
psix-384286

Inspections, by type

…with no type recorded6
Years with a record 14 calendar years (1993–2025)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it10412 - Convention (Subpart B), Gross Ton
5253 - Convention (Subpart B), Net Ton
10713 - Dead Weight, Metric Ton
16958 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

21 January 2025 Deficiency Check · PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8066732
28 July 2021 PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7270979
22 May 2020 PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6957934
5 May 2020 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6950867
10 December 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6594624
15 March 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6372391
12 July 2017 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6190894
1 December 2016 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6050841
7 November 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6036984
9 February 2016 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5812087
24 July 2015 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5193997
2 December 2011 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4197308
31 January 2011 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3936132
24 January 2010 PII Safety Exam · ISPS III Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3668671
22 January 2009 PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3397841
10 January 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2853854
30 September 2003 Periodic Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1916183
15 September 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1906800
2 August 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1872956
21 July 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1856636
7 July 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1838265
23 June 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1826276
12 May 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1796578
17 March 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1758183
9 October 1995 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 383852
18 April 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 377468
25 January 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 374525
2 January 1995 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 386351
24 January 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 526709

Deficiency record · 5

05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 21 January 2025 Resolved
Every ship shall be provided with a satellite emergency position-indicating radio beacon which shall be capable of floating free if the ship sinks and of being automatically activated when afloat. PSCO observed liferaft hydrostatic release on EPIRB. 74SOLAS(20)IV/7.1.6.4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 January 2025
Resolved 21 January 2025
Resolution: Sector Delaware Bay received documentation from the vessel that the appropriate hydrostatic release was delivered and installed.
Construction/Loadline › Markings › Load Line Mark
Issued 15 March 2018 Resolved
1299 - The ring, lines, and letters of the load line shall be painted in black on a light background. The load line is painted blue. 40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 December 2018
Resolution: Line was repainted.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 7 November 2016 Resolved
74 SOLAS (97) II-2/18.5 WASTE RECEPTACLES SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS WITH NO OPENINGS IN THE SIDES OR BOTTOM; WASTE RECEPTACLES LOCATED ON THE WEATHER DECK ARE MADE OF WOOD.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 December 2016
Resolution: 01DEC16- Sector Delaware Bay conducted an administrative PII deficiency check exam. Cleared 01 deficiencies from Sector Delaware Bay. 01 deficiencies remain. Activity #6036984 See attached documentation submitted by vessel.
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 29 September 2003 Resolved
Vessels doors in main stairtower were found to be outfitted with holdback devices, of the non fail-safe type.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2003
Resolved 30 September 2003
Resolution: All hold back devices were removed from stair tower.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 29 September 2003 Resolved
Vessels seacock to overboard discharge on the marine sanitation device was not secured in a manner acceptable to 33 CFR 159.7 (b)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2003
Resolved 30 September 2003
Resolution: A padlock and chain was affixed to the overboard discharge valve.