Records from 1993 to 2026. Most recent: inspection, 2 April 2026.
Inspection history · 69
2 April 2026
Annual Inspection · Vessel Attendance · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8204105
18 February 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8037541
22 May 2024
Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7734030
28 February 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7733962
23 January 2023
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7602799
2 June 2022
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7457666
2 February 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7399644
29 September 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7322765
29 September 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7352401
25 March 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7162965
14 January 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7124600
20 May 2020
Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6956282
26 December 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6879244
24 July 2019
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6761429
24 July 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6769891
24 April 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6646036
6 June 2018
Examination of Repairs · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6444722
23 May 2018
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6405182
25 January 2018
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6340664
29 November 2017
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6314735
19 April 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6106743
9 May 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5868509
22 April 2016
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5860446
21 April 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5865919
22 February 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5812103
28 April 2015
Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5086831
19 November 2014
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5002535
23 April 2014
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4828691
10 June 2013
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4616966
28 January 2013
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4520570
4 October 2012
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4455357
30 May 2012
DAPI Audit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4368981
6 January 2012
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4220006
16 February 2011
Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3946034
26 October 2010
Plan Review (Other than "T") · Hull Examination · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3870140
20 January 2010
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3651002
28 May 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3488593
26 May 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3488539
13 May 2009
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3473228
29 January 2009
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3412546
22 January 2009
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3366040
28 January 2008
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3136556
25 January 2008
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3136535
31 May 2007
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2931425
25 March 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2611211
18 January 2006
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2569054
11 May 2005
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2355040
22 November 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2244623
11 December 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1959549
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963225
29 May 2003
Internal Structural Exam · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1805060
21 April 2003
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1777966
30 October 2002
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1698469
29 November 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1403497
2 July 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 754382
30 June 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 189997
17 April 2001
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1449454
7 February 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440437
8 November 1999
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1399220
6 November 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375548
6 November 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390633
29 October 1997
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1364435
8 November 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416400
8 November 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1438372
5 October 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355471
10 November 1994
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1467433
7 December 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1159907
18 November 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1155476
9 November 1993
Inclining Experiment · Plan Review "T" Boat · Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1439443
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 April 2026
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must have suitable propulsion controls to provide the operator full control at each operating station. While underway and conducting drills, the vessel's starboard propulsion control system failed to provide astern command from the pilothouse control station. Vessel required emergency/manual controls to obtain reverse thrust.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 April 2026
Resolution: Conducted satisfactory sea trial.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 February 2025
Resolved
FIXED FIRE PUMPS MUST BE CAPABLE OF BEING ENERGIZED REMOTELY FROM A SAFE PLACE OUTSIDE THE ENGINE ROOM. MI DISCOVERED FIXED FIRE PUMP HAD NO REMOTE START.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 March 2025
Resolved 31 March 2025
Resolution: Remote fire pump installed and tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 February 2024
Resolved
Air receiver must have pressure relief tests conducted twice per five years. Receiver pressure went over 10% of the relief valve setting and failed to open. Relief valves must relieve pressure within 10% of setting.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2024
Resolved 29 February 2024
Resolution: Received a photo from the vessel representative of a newly-installed relief valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2023
Resolved
Each towing vessel must carry at least one appropriately-sized life jacket, approved under approval series 160.002, 160.005, 160.055, 160.155, or 160.176, for each person on board. MI found two missing life jackets. Vessel is restricted to carrying max of 12
passengers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2023
Resolved 6 February 2023
Resolution: Operator obtained the required amount of life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 January 2023
Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended back flooding through bilge piping. MI found no check valve's in installed bilge piping.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2023
Resolved 6 February 2023
Resolution: Operator installed required check valves in suction lines. MI witness operational test.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 January 2023
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. MI found watertight door in engine room & storage space with deteriorated gaskets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2023
Resolved 6 February 2023
Resolution: Operator installed new gaskets in all water tight doors.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 23 January 2023
Resolved
The size, material, and condition of towlines, lines, wires, push gear, cables, and other rigging used for making up a tow or securing the towing vessel to a tow must be appropriate for the static loads and dynamic loads expected during the intended service. MI found
port head wire frayed in multiple areas.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2023
Resolved 6 February 2023
Resolution: Operator installed new head wires.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 January 2023
Resolved
A record of the type,size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name of person conducting the exam. Vessel could not provide the required information on the towlines used in service.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2023
Resolved 24 January 2023
Resolution: Operator provided required documentation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 June 2022
Resolved
An ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. For each alternating current generator, a means for measuring frequency must also be provided. Starboard electrical panel ammeter not mounted properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2022
Resolved 1 July 2022
Resolution: Installed new amp meter.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 February 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Inspector identified an ungrounded electrical outlet located next to the galley stove.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2022
Resolved 21 February 2022
Resolution: Electrical outlet properly connected to grounding wire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 February 2022
Resolved
Essential systems or equipment must be regularly tested and examined. Pressure relief valves must be tested twice every five years, with no more than three years elapsing since last test. The last test date of the pressure relief valve installed on the engine room air receiver could not be verified.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2022
Resolved 21 February 2022
Resolution: A new pressure relief valve was intalled.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 February 2022
Resolved
Each towing vessel must have either a self-priming power-driven, fixed fire pump capable of 50psi, a fire main, and hoses and nozzles or a portable pump capable of 60psi, and hoses and nozzles. Vessel did not have a fire pump onboard capable of meeting the pressure or gallons per minute requirement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2022
Resolved 21 February 2022
Resolution: Vessel installed a compliant fire pump meeting the pressure and gallons per minute requirement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 2 February 2022
Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available. Inspector found that a record book containing the required information for towlines was not available for inspection.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2022
Resolved 21 February 2022
Resolution: A record book of the towlines was created and maintained for inspection.
Navigation › Piloting/Steering › Steering Magnetic Compass
Issued 25 January 2018
Resolved
Vessel needs a compass light for night service.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 26 January 2018
Resolution: Compass light was repaired.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 19 April 2017
Resolved
Provide 02 adult life jackets
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 19 April 2017
Resolution: Provided 02 adult life jackets on the spot
Engineering › Sea-water System (primary cooling) › Valve
Issued 9 May 2016
Resolved
Replace both (2) sea-valves.
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 20 May 2016
Resolution: Replaced with new before vessel was launched.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 22 April 2016
Resolved
Repair starboard shaft prior to operations.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2016
Resolved 9 May 2016
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 22 February 2016
Resolved
Provide 04 Adult lifejackets.
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 22 February 2016
Resolution: Life jackets were renewed during the inspection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 April 2015
Resolved
Vessel is overdue for its required annual exam. vessel is restricted from carrying Passangers until a satisfactory annual exam has been completed by a marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2015
Resolved 12 May 2015
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 28 April 2015
Resolved
Provide fire service report
Due 22 May 2015
Resolved 12 May 2015
Resolution: Def cleared.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 April 2015
Resolved
Replace expired first aid items as I.D.
Due 15 May 2015
Resolved 12 May 2015
Resolution: Def cleared.
Communications › Radio Communications › VHF Radiotelephone
Issued 23 April 2014
Resolved
Provide current Radiotelephony Safety Certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 23 April 2014
Resolution: Current certificate provided.
Documentation › Markings/Placards › Lifejacket Placard
Issued 23 April 2014
Resolved
Provide proper life jacket donning placard for the correct type of life jackets onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 April 2014
Resolved 23 April 2014
Resolution: Proper life jacket placard provided.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 6 January 2012
Resolved
Label all circuit breaker switches accordingly.
Condition: Improper/Lack of Maintenance
Due 31 January 2012
Resolved 31 January 2012
Resolution: Fixed on the spot.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 January 2012
Resolved
Provide vessel's name and call sign on emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2012
Resolved 1 February 2012
Documentation › Certificates/Documents › FCC SSL
Issued 22 January 2009
Resolved
Radio safety certificate not on board at time of inspection. Provide ship radio safety certificate. Vessel is restricted to 1000ft from shore until completed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2009
Resolved 29 January 2009
Resolution: Received faxed copy of last Radio Safety Certificate.
Accommodation/Occupational Safety › Ventilation › General
Issued 30 January 2008
Resolved
Provide adequate sealing system for electrical duct in center overhead and through bulkhead (aft) fitting in tool compartment.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 22 February 2008
Resolution: Received sufficient digital photos verifying rectification of 835.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 January 2008
Resolved
Vessel is required to have a COI inspection conducted by a CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2008
Resolved 28 January 2008
Resolution: COI conducted.
Construction/Loadline
Issued 17 April 2001
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Engineering
Issued 8 November 1999
Resolved
Install flame impingement bowls on the fuel filters located on the main engines.
Condition: Unknown
Due 17 November 1999
Resolved 16 November 1999
Construction/Loadline
Issued 8 November 1999
Resolved
Make bilges clean for inspection of engine room.
Condition: Unknown
Due 17 November 1999
Resolved 16 November 1999
Documentation
Issued 9 November 1993
Resolved
POST ON BOARD A VALID STABILITY LETTER.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993
Documentation
Issued 9 November 1993
Resolved
PROVIDE ON BOARD A VALID RADIOTELEPHONEY SAFETY CERTIFICATE.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993
Documentation
Issued 9 November 1993
Resolved
PROVIDE ON BOARD A VALID FCC RADIO STATION LICENSE.
Condition: Unknown
Due 9 November 1993
Resolved 9 November 1993