← All vessels
BASTIAN BAY
Oil Recovery · Miscellaneous Vessel class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named BASTIAN BAY
BASTIAN BAY is a 2001 oil recovery. The Coast Guard has recorded 28 inspections since 2004, most recently in October 2025, along with 19 deficiencies and 1 casualty investigation in 2010.
Records from 2004 to 2025. Most recent: inspection, 2 October 2025.
- Built
- 2001
- Last inspected
- 2 October 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2010
Identity
1120426
WDE3709
38438
Flag
UNITED STATES
367343120
Maury page id
psix-38438
Inspections, by type
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 6.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROZEMA BOAT WORKS INC · MOUNT VERNON, WA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE CHARLES, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 September 2026 · expires 31 August 2027
Service, as the file records itOil Recovery
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDE3709MMSI 367343120 · active · compulsorily equipped · granted 1 March 2018, expires 15 March 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 28
2 October 2025
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8245518
20 August 2025
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8217839
5 November 2024
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8032346
20 July 2023
Examination of Repairs · COI Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7741946
24 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7674419
26 August 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7543991
31 January 2022
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7388113
24 August 2021
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7301775
12 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7155218
23 March 2020
Administrative Inspection · Annual Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6930541
7 October 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6829835
14 August 2019
Plan Review (Other than "T")
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6782999
11 June 2019
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6711152
30 May 2019
Damage Survey · Examination of Repairs · Drydock Exam · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6698460
16 January 2019
COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6600149
30 November 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6589880
23 January 2018
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6329861
26 January 2017
DAPI Audit · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6066641
28 January 2016
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5790245
2 February 2012
Cargo Tank Internal · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4240243
22 February 2011
Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3950118
24 March 2010
Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3702451
16 March 2009
COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3434006
8 February 2008
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3144308
6 March 2007
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2882878
26 April 2006
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2634608
25 March 2005
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2319557
10 March 2004
Initial Certification · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2022326
Deficiency record · 19
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 October 2023
Resolved
The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills. Vessel crew unavailable at time of inspection. Conduct satisfactory drills prior to operations.46 CFR 176.404(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2023
Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Life buoy was found to be wasted. Renew.46 CFR 180.70(a)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 October 2023
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. EPIRB hydrostatic release unit was not marked with expiration date. Operations are restricted to less than 3 NM until HRU renewal.46 CFR 185.740
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2023
Resolved
electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Exposed wiring found under navigation console. Properly secure or remove wiring.46 CFR 183.200(c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 October 2023
Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that a positive shutoff valve is installed at the hull penetration. Positive shutoff valve was not installed with bilge pump arrangements. Install shutoff valves.46 CFR 182.520(e)(7)
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 23 March 2020
Resolved
Each survival craft must be secured to the vessel by a painter with a float free link permanently attached to the vessel. Stowed so that when the vessel sinks the survival craft floats free and if inflatable inflates automatically. Inspector found painter attached to vessel not weak link. Crew rectified painter and approved by inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 October 2019
Resolved
Vessels fixed fire extinguishing system was installed but never successfully tested by the Coast Guard. Marine Inspectors attended vessel to test but the master was unable to start the ships service generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2019
Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity. Master was unable to prove operation of the ships generator.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 October 2019
Resolved
A self priming power driven fire pump must be installed. Vessel must prove poroper operation of installed fire pump to the satisfaction of attending Coast Guard Marine Inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2019
Resolved
Fire buckets not sufficient means of firefighting. Vessel shall meet the requirements of 46 CFR 34.10-5 (Subchapter D) or be provided with a power driven fire pump and fire station meeting the requirements of 46 CFR 181.10-1 (Old T).
46 CFR 181.10-1 (Old T)
46 CFR 34.10-5(a)
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 January 2019
Resolved
Prove proper operation of machinery shutdown and override.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 March 2009
Resolved
Vsl had charts that were not corrected/up to date. Vsl must provide charts that are up to date w/corrections before getting under way.
Fire Fighting › Structural - A Class Divisions › Hose Ports
Issued 16 March 2009
Resolved
Vsls cable/wire ways were not properly packed with anything. Cable/wire ways were open. Vsl must properly pack with approved fire retardant agent.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 March 2009
Resolved
Vessel was missing complete CG approved First Aid Kit.
Communications › Radio Communications › EPIRB
Issued 16 March 2009
Resolved
Vsls EPIRB hydrostatic release was not properly marked when installed indicating date of installation.
Communications › Radio Communications › EPIRB
Issued 16 March 2009
Resolved
Vsl did not have valid EPIRB Registration Certificate.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 March 2009
Resolved
Vsl had expired alcohol test strips on board.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 16 March 2009
Resolved
Vsl did not have a Discharge of Sewage placard.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 16 March 2009
Resolved
Vsl did not have a Lifesaving Equipment Service Log and Emergency Drills Sheets.
Casualty record · 1
18 May 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3741383
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.