Records from 1993 to 2001. Most recent: inspection, 6 May 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
6 May 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 289852
31 May 1999
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 429826
25 February 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 516025
11 February 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 412709
9 April 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 402611
19 December 1995
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 385408
29 April 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 390450
18 September 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412696
14 September 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 370410
9 September 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 370283
9 September 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 866212
20 February 1993
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 465348
24 January 1993
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 508296
Construction/Loadline
Issued 6 May 2001
No resolution recorded
Replace/Renew hydraulic line to watertight door that leads from engine roomto emergency fire pump room to satisfaction of class
Condition: Unknown
Due 7 May 2001 — due date passed with no resolution recorded
Lifesaving
Issued 6 May 2001
No resolution recorded
replace/renew limit switch on starboard side boat davit to the satisfactionof class.
Condition: Unknown
Due 7 May 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 6 May 2001
No resolution recorded
Replace/Renew wasted/missing sprinkler heads in paint locker.
Condition: Unknown
Due 7 May 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 6 May 2001
No resolution recorded
Replace/Renew all fire call boxes that are inoperative to the satisfaction of Class.
Condition: Unknown
Due 7 May 2001 — due date passed with no resolution recorded
Lifesaving
Issued 6 May 2001
No resolution recorded
Adjust all self-closing devices on engine room doors to allow doors to_x001C_ close properly.
Condition: Unknown
Due 7 May 2001 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 31 May 1999
Resolved
SEWAGE SYSTEM DISCHARGE LINE HAS SOFTPATCH, LOCATED IN MACHINERY SPACE.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Deck/Cargo
Issued 31 May 1999
Resolved
MISSING MECHANICAL MEANS OF CLOSURE FOR FIX FUEL AND LUBE OIL CONTAINMENT.
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Lifesaving
Issued 31 May 1999
Resolved
EMBARKATION LADDER, STBDSIDE IS NOT ATTACHED TO APPARATUS FOR DECK SECURING._x001C_
Condition: Unknown
Due 7 May 2001
Resolved 7 May 2001
Lifesaving
Issued 9 April 1997
Resolved
REPLACE FORWARD PORTSIDE RING BOUY.
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Electrical
Issued 9 April 1997
Resolved
REPAIR/REPLACE AIR DUCT FOR EMERGENCY GENERATOR TO CLASS SOCIETY SATISFACTION.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Fire Fighting
Issued 9 April 1997
Resolved
REPLACE/REPAIR FIRE HYDRANT VALVE LOCATED AFT OF HOUSE ON LIFEBOAT DECK TO CLASS SOCIETY SATISFACTION.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Lifesaving
Issued 9 April 1997
Resolved
PROPERLY ATTACH LIFERING LIGHT ON PORTSIDE LIFEBOAT DECK.
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Lifesaving
Issued 9 April 1997
Resolved
REPLACE 13 FOOD RATIONS FOR PORTSIDE LIFEBOAT AND 41 FOOD RATIONS FOR STARBOARD LIFEBOAT
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Unknown
Issued 9 April 1997
Resolved
REPLACE RUBBER HOSE WITH HARD PIPING FOR SANITARY LINE LEADING TO SANITARY PUMP TO CLASS SOCIETY SATISFACTION.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Electrical
Issued 9 April 1997
Resolved
REPLACE/REPAIR #1 GENERATOR (STARBOARD) COOLING WATER O-RING TO CLASS SOCIETY SATISFACTION.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Construction/Loadline
Issued 9 April 1997
Resolved
GAUGE ALL OF AFT MAIN DECK AND LIFEBOAT DECK FOR THICKNESS WITH CLASSIFICATION SOCIETY PRESENT AND REPLACE STEEL AS NEEDED. PROVIDE A CLASSREPORT OF FINDINGS TO THE U.S.COAST GUARD.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Construction/Loadline
Issued 9 April 1997
Resolved
TIGHTEN/OR REPLACE PACKING ON LEAKING PUMPS #2 BALLAST AND #2 AUXILLARY S/WPUMP TO CLASS SOCIETY SATISFACTION.
Condition: Unknown
Due 11 February 1998
Resolved 11 February 1998
Lifesaving
Issued 19 December 1995
Resolved
PROPERLY MOUNT SMOKE AND LIGHT APPARATUS ON PORT BRIDGE WING LIFEBOUY. SOLAS CHAPTER III, PART B: REGULATION 7-1.3.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Deck/Cargo
Issued 19 December 1995
Resolved
RENEW THE AFT #3 STARBOARD HATCH HYDRAULIC FITTING THAT IS LEAKING.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Deck/Cargo
Issued 19 December 1995
Resolved
CLEAR FOULED PORT ANCHOR OF DEBRIS.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Fire Fighting
Issued 19 December 1995
Resolved
RENEW FIRE HOSE BOXES AND BRACKETS ON MAIN DECK.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Unknown
Issued 19 December 1995
Resolved
GARBAGE ON FANTAIL WAS NOT STOWED PROPERLY AND WAS A THREAT TO BE BLOWN OVERBOARD.
Condition: Unknown
Due 22 December 1995
Resolved 22 December 1995
Construction/Loadline
Issued 19 December 1995
Resolved
MAKE PERMANENT REPAIR TO STARBOARD AFT POOP DECK PLATING.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Construction/Loadline
Issued 19 December 1995
Resolved
PRIOR TO DEPARTURE, HAVE CLASSIFICATION SOCIETY MAKE RECOMENDATION ON REPAIR TO POOP DECK AFT STARBOARD AREA. WASTAGE CAN BE SEEN FROM THE STEERING FLAT ABOVE THE MOORING WINCH CABINET.
Condition: Unknown
Due 22 December 1995
Resolved 22 December 1995
Lifesaving
Issued 19 December 1995
Resolved
RENEW PORT AFT WATERLIGHT BRACKET.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Fire Fighting
Issued 19 December 1995
Resolved
REPAIR FIRE DETECTION SYSTEM IN STEERING ROOM.
Condition: Unknown
Due 22 December 1995
Resolved 22 December 1995
Lifesaving
Issued 19 December 1995
Resolved
PLACE WATERLIGHTS ON IMMERSION SUITS.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Lifesaving
Issued 19 December 1995
Resolved
REPAINT OR RENEW THE TWO LIFERINGS ON LIFEBOAT DECK. COLOR IS NOT INTERNATIONAL ORANGE.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Construction/Loadline
Issued 18 September 1994
Resolved
Repair water tight door on forecastle "house". Repair within 30 days or prior to next U.S. port call._x001C_ _x001C_ SOLAS II-1 reg 18_x001C_
Condition: Unknown
Due 18 September 1994
Resolved 19 September 1994
Construction/Loadline
Issued 18 September 1994
Resolved
Repair the two electric wire penetrations for the vent fans on the stbd. side of forecastle (bos'n hole and mag locker) within 30 days or prior to next U.S. port call._x001C_ SOLAS II reg 19.1_x001C_
Condition: Unknown
Due 18 September 1994
Resolved 19 September 1994
Lifesaving
Issued 18 September 1994
Resolved
Make available all SOLAS required lifeboat provisions and supplies for C.G.inspectors examination. _x001C_ _x001C_ SOLAS IIIreg41 8_x001C_
Condition: Unknown
Due 18 September 1994
Resolved 19 September 1994
Lifesaving
Issued 18 September 1994
Resolved
Provide SOLAS required visual signals. Obtain prior to sailing_x001C_ _x001C_ _x001C_ SOLAS III reg 35,36,and 37_x001C_
Condition: Unknown
Due 18 September 1994
Resolved 19 September 1994
Unknown
Issued 18 September 1994
Resolved
Install plugs for all spill/overflow containment drain holes. Prior to next U.S. port call or within 30 days._x001C_ _x001C_ 33CFR155.320
Condition: Unknown
Due 18 September 1994
Resolved 19 September 1994
Lifesaving
Issued 18 September 1994
Resolved
Ensure proper installation of all ring buoys and water lights. Effect repair prior to sailing._x001C_ _x001C_ SOLAS III;7-1.1,1.2_x001C_
Condition: Unknown
Due 18 September 1994
Resolved 19 September 1994
Construction/Loadline
Issued 18 September 1994
Resolved
Refit wasted fresh water standpipe aft of brow, stbd side. Effect repairs within 30 days or prior to next U.S. port._x001C_ _x001C_ ILO 147
Condition: Unknown
Due 18 September 1994
Resolved 19 September 1994
Accommodation/Occupational Safety
Issued 18 September 1994
Resolved
Repair or replace wasted ladder treads and hand rails on aft ladders. Makerepairs within 30 days or prior to next U.S. port call._x001C_ _x001C_ ILO 147
Condition: Unknown
Due 18 September 1994
Resolved 19 September 1994
Fire Fighting
Issued 18 September 1994
Resolved
Make permanent repair to fire main piping. Effect repairs prior to sailing._x001C_ _x001C_ SOLAS II-2;4-4.1
Condition: Unknown
Due 18 September 1994
Resolved 19 September 1994
Lifesaving
Issued 18 September 1994
Resolved
Repair broken life boat seats and stowage compartments on the port life boat. Repair prior to sailing._x001C_ _x001C_ SOLAS Chap III reg 26,41,47_x001C_
Condition: Unknown
Due 18 September 1994
Resolved 19 September 1994
Electrical
Issued 18 September 1994
Resolved
Complete installation of emergency generator and provide Class report upon completion of repairs prior to sailing._x001C_ _x001C_ SOLAS ChapII-1 reg 42 1.1 and 2: II-2 reg 4 3.3.2
Condition: Unknown
Due 18 September 1994
Resolved 19 September 1994