MAURY USCG vessel records Sign in
← All vessels

ZEUS

ZEUS is a 1992 tank ship. The Coast Guard has recorded 87 inspections since 1993, most recently in June 2012, along with 26 deficiencies — 1 with no resolution recorded — and 14 operational controls.

Records from 1993 to 2012. Most recent: operational control imposed, 25 June 2012.

Built
1992
Last inspected
24 June 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9038828 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
384457
Flag
PANAMA
—
Maury page id
psix-384457

Inspections, by type

…with no type recorded43
…past their stated due date1
Years with a record 19 calendar years (1993–2012)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it54827 - Convention (Subpart B), Gross Ton
29295 - Convention (Subpart B), Net Ton
115807 - Displacement, Ton
99450 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

M V GERTIE C Offshore Supply Vessel · MISLE 53852 · 10 September 2008 · activity 3332277NITA M Freight Ship · MISLE 223549 · 5 July 2003 · activity 1852736

Inspection history · 87

24 June 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4355195
24 June 2012 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4357747
24 June 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4358594
22 June 2012 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4346429
21 June 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4346428
18 September 2010 COE-Dockside
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3852333
7 January 2010 COC-TVE Renew · MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex VI Survey · ISPS III Exam · COE-Offshore · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3658287
14 July 2009 COE-Dockside
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3534067
2 July 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3521421
6 May 2009 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3468547
15 April 2009 COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3453198
30 March 2009 COE-Dockside
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3442736
24 March 2009 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3439427
10 March 2009 COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3430781
19 February 2009 COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3420283
29 January 2009 ISPS III Exam · COE-Dockside
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3401363
2 December 2008 COC-TVE Annual · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3369993
10 September 2008 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3332277
12 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3236352
22 May 2008 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3213316
27 March 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3172359
23 February 2008 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3148572
13 January 2008 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3126992
28 December 2007 MARPOL Annex I Examination · MARPOL Annex V Examination · COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3120094
15 October 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3080352
27 September 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3067676
8 February 2007 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2869099
23 January 2007 NPV Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2860345
19 January 2007 COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2854394
22 August 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2756238
26 May 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2655823
10 May 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2646433
9 December 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2542497
18 November 2005 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2536937
19 May 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2363728
15 May 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2358784
27 January 2005 Random ISPS/MTSA/PSC · Spot Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2281681
24 December 2004 COC-TVE Annual
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2264407
9 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2256579
9 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2307604
7 December 2004 PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2254787
6 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2256673
27 July 2004 ISM Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2146823
10 July 2004 ISPS II Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2123104
28 June 2004 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2114248
6 January 2004 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1977028
16 December 2003 Certificate of Compliance
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1965242
10 November 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1944916
4 November 2003 Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1941636
27 October 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1936714
27 October 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1936724
5 July 2003 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1852736
10 January 2003 Periodic Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1728504
1 December 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1712186
1 October 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1682923
8 April 2002 Ballast Water Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1602277
4 February 2002 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1483604
4 February 2002 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1483679
7 July 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 291627
29 January 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 286587
20 September 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 282222
16 March 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 275679
7 March 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 275453
2 November 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 434236
2 November 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 434830
17 October 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 433759
19 March 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 426573
4 March 1999 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 467294
16 July 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 492248
18 February 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 413225
4 October 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 180896
20 February 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 400894
7 October 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 396183
12 February 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 387640
22 October 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 870637
4 February 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 374972
8 January 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 500831
2 July 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 470386
29 March 1994 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 365567
14 March 1994 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1164571
1 February 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 364057
28 January 1994 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1409070
7 December 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 362923
24 July 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 451753
8 May 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 358237
26 January 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 355963
26 January 1993 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1403578

Deficiency record · 26

Engineering › Fuel Oil Service System › Valve, Solenoid
Issued 26 June 2012 Resolved
Vessel experienced a propulsion loss while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2012
Resolved 26 June 2012
Resolution: Received, reviewed and accepted class report from [name withheld] stating the Solenoid valve was repaired, tested and found satisfactory.
Deck/Cargo › Holds/Tanks › Ullage
Issued 22 June 2012 Resolved
1885-Tank entry-All tankers fitted with a fixed inert gas system shall be fitted with a closed ullage system. PSC team noted several cargo tank manhole covers that are leaking gas to the atmosphere. Provide attestation from certificate issuing authority as to integrity of manhole cover seals. SOLAS II-2/60
Action required: 705 - Other - as specified
Due 6 July 2012
Resolved 23 June 2012
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. All gaskets were renewed and found with no leaks as witnessed by the class surveyor.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 22 June 2012 No resolution recorded
1836-Temp control- Cargo pumps installed in cargo pump rooms shall be fitted with temp sensing devices. #3 cargo pump is missing temp sensor for lower pump casing. Provide documentation from cert issuing authority attesting to proper operation of all temp sensors on #3 cargo pump. Vsl is restricted from cargo ops using #3 cargo pump in US waters. SOLAS II-2/4
Action required: 705 - Other - as specified
Due 6 July 2012 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 27 March 2008 Resolved
INOP ARAP
Action required: 705 - Other - as specified
Resolved 1 April 2008
Resolution: Recieved class report, satisfactory
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 March 2008 Resolved
INOP SECOND RADAR
Action required: 705 - Other - as specified
Resolved 1 April 2008
Resolution: Recieved class report,satisfactory
Construction/Loadline › Markings › Summer Load Line
Issued 28 December 2007 Resolved
Load line markings not marked in accordance with ICLL, 1966, Reg. 6 [S, W, WNA, T, TF] nor does it match the International Loadline Certificate issued on 08Aug07. 30 days to the satisfaction of Class Society
Action required: 705 - Other - as specified
Due 28 January 2008
Resolved 23 February 2008
Resolution: Received a copy of the new International Load Line Certificate that reflects the exact markings on the hull.
Personnel › Certificates/Documents/Licenses › License, Third Mate
Issued 28 December 2007 Resolved
The Third Officer, Jose D. Gutierrez, does not have his original Flag State endorsement onboard, copy only. STCW 95, Reg. I/2 (9) To the satisfaction of Flag State and CG PSCO.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 January 2008
Resolution: Checked Officers licesnses and Flag State endorsements. All new Oficers on board had valid licenses.
Engineering › Lubricating Oil Service System › Piping
Issued 23 January 2007 Resolved
Lube oil leak in main engine causing reduced maneuverability. Condition must be rectified to the satisfaction of class prior to next U.S. port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 February 2007
Resolution: Received Class Report from BV attesting to the satisfactory repairs. A compression washer on the coupling was found to be faulty. The washer was replaced and the unit was tested under pressure to satisfaction.
Deck/Cargo › Ballast › Piping
Issued 18 January 2007 Resolved
Ballast water line in way of #2 pump in cargo pump room at first fitting after pump is leaking excessively. Recitify prior to departure to satisfaction of Class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Resolution: Received Class Report from BV attesting to the satisfactory repairs to the ballast line. Line has been tested under pressure to satisfaction.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 18 January 2007 Resolved
IGS blower #1 leaking where drain pipe meets casing. Potential for gas to escape into engine room. SOLAS 74 (2004 Consolidated edition) CH. II-2/4.5.5 / FSS Code Ch. 15.2.2.3.1 Rectify prior to departure from port to satisfaction of Class
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Resolution: Received Class Report from BV attesting to the satisfactory repairs and testing to the blower.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 10 May 2006 Resolved
Vapor lines not labeled in accordance with 46 CFR 39.20-1
Action required: 705 - Other - as specified
Resolved 10 May 2006
Resolution: Deficiency was corrected on the spot.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 27 July 2004 Resolved
Main engine bridge control automation is inop. Master must provide proof of proper operation from Class society or tech report.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 7 December 2004
Resolution: Received tech report satisfying requirement.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 16 December 2003 Resolved
REPACK OR RENEW SEALS ON #1 & #3 CARGO PUMPS LEGACY COMPONENT DESC: Cargo Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 December 2003
Resolved 4 January 2004
Resolution: Renewed seals
Electrical › Lighting (service)
Issued 16 December 2003 Resolved
REPLACE CRACKED BULB LENS ON 3RD DECK IN PUMPROOM ACCESS TRUNK LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 16 December 2003
Resolved 4 January 2004
Resolution: Lens replaced
Construction/Loadline › Structures
Issued 16 December 2003 Resolved
WALKWAY OVER PIPES FOWARD OF IGS GENERATOR ROOM. LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 16 December 2003
Resolved 4 January 2004
Resolution: Install new diamond tread plate on walk-over
Fire Fighting › Nozzles
Issued 16 December 2003 Resolved
REPLACE MISSING DEFLECTION AND ELEVATION LOCKS ON FIRE MONITORS LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 16 December 2003
Resolved 4 January 2004
Resolution: Fabricated and install new locking pins
Engineering › Diesel Engine (propulsion-direct drive)
Issued 7 November 2003 Resolved
Make permanent repairs to the MDE high temp, cooler prior to next U.S. port. LEGACY COMPONENT DESC: Cooler discharge line
Action required: 15 - Rectify deficiencies by next port
Resolved 7 November 2003
Navigation › Electronic Positioning
Issued 4 February 2002 Resolved
Echo Depth Sounder was inoperable. Vessel recieved one outbound Letter of Deviation. LEGACY COMPONENT DESC: ECHO DEPTH SOUNDER
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 6 February 2002
Resolved 6 February 2002
Resolution: Item corrected.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 4 February 2002 Resolved
Vessel's audiable alarm for the high level cargo tanks is inoperable.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 4 February 2002
Resolved 4 February 2002
Resolution: corrected
Documentation › Certificates/Documents
Issued 4 February 2002 Resolved
DOCUMENT EXPIRED. CANNOT UPDATE DOCUMENT, NEW ISSUE/EXPIRATION DATE: ABS, CORPUS CHRISTIE, 16 NOV 01, 16 NOV 02. LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Action required: 15 - Rectify deficiencies by next port
Due 28 February 2002
Resolved 6 February 2002
Resolution: Item corrected.
Deck/Cargo
Issued 7 March 2000 Resolved
#1 IGS BLOWER MOTOR BECAME EXCESSIVELY HOT AND BEGAN TO SMOKE. PAINT ON MOTOR CASING BLISTERED. SOLAS 74 (A) II-2/62
Condition: Unknown
Due 16 March 2000
Resolved 16 March 2000
Deck/Cargo
Issued 20 February 1997 Resolved
REMOTE SHUTDOWN ON #2 CARGO PUMP FAILED TO WORK PROPERLY
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Accommodation/Occupational Safety
Issued 28 January 1994 Resolved
Replace burnt out light bulbs in escape trunk.
Condition: Unknown
Due 28 January 1994
Resolved 28 January 1994
Navigation
Issued 28 January 1994 Resolved
Replace seals on both steering servo pumps.
Condition: Unknown
Due 28 January 1994
Resolved 28 January 1994
Fire Fighting
Issued 28 January 1994 Resolved
Provide to cognizant OCMI, foam analysis report and annual service report of portable fire extinguishers.
Condition: Unknown
Due 28 January 1994
Resolved 28 January 1994
Navigation
Issued 28 January 1994 Resolved
Remove rags and open oil buckets from steering room
Condition: Unknown
Due 28 February 1994
Resolved 2 March 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.