Records from 2016 to 2026. Most recent: inspection, 27 May 2026.
Documentation record
Registered dimensions (L × B × D)56.0 ft × 16.0 ft × 9.7 ft
Registered tonnagegross 58 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARRO YACHTS, INC. · ARUNDEL, ME, UNITED STATES · built 1993
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSOUTH AMBOY, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Simplified, Gross Ton
46 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
27 May 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8381196
2 June 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8150441
20 February 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8081823
30 May 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7922802
21 April 2023
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7661780
14 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7636109
3 February 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7631723
20 April 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7434554
29 March 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7164514
19 January 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7126501
6 August 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7024557
17 July 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7008971
26 April 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6671027
11 April 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6660716
16 April 2018
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392605
16 May 2017
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6147146
28 March 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6112762
16 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5878598
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 27 May 2026
No resolution recorded
"Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc." Main engine shafts did not have guards over them. Install guards prior to the next credit drydock.
46 CFR 177.35-15(a)
OLD T
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 May 2024
Resolved
WATER-LIGHT ON PORT LIFE-FLOAT HAD CRACKED HOUSING AND LANYARD WAS WEATHERED. REPLACE REQUIRED WATER-LIGHT PRIOR TO OPERATING BEYOND 3NM FROM SHORE OR W/IN 07 DAYS.
46 CFR 180.175
Action required: 705 - Other - as specified
Resolved 30 May 2024
Resolution: Accepted evidence of replacement & proper arrangement.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 30 May 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 24 June 2024
Resolution: Accepted evidence of new EPIRB battery, new NOAA registration, & onboard.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 30 May 2024
Resolved
MOB RECOVERY PROCESS REQUIRED PHYSICAL EXERTION AND APPROX. 4FT LIFT FROM WATERLINE, UNLIKLEY POSSIBLE BY ALL CREW-MEMBERS. PROVIDE EFFECTIVE MOB RECOVERY PROCEDURE / EQUIPMENT PROPOSAL W/IN 14 DAYS AND IMPLEMENT W/IN 30 DAYS OF APPROVAL.
46 CFR 185.520
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2024
Resolution: Accepted revised MOB procedures - to be implemented via training / drills, verified next inspct.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 April 2023
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. 02 life floats on board the vessel had frayed lifelines with inadequate strength. Replace lines on the 02 serviceable life floats on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 5 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 April 2023
Resolved
Each vessel constructed of material other than wood certificated to operate on a limited coast wise route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Vessel's 3rd, 22 person life float is in unsatisfactory condition and needs to be replaced. Prior to operating with 66 persons as allowed in cold water on the COI, replace 3rd lifefloat.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2023
Resolved 5 May 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Operational Limitations for Passenger ships
Issued 3 February 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel missed its latest drydock and internal structural exams required by 31JAN2023. Operations are restricted until satisfactory drydock and internal structural exams are completed.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2023
Resolution: Completed credit DDX/ISE
Navigation › Piloting/Steering › Marine Charts
Issued 16 April 2018
Resolved
Vessel must provide updated nautical charts.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2018
Resolved 27 April 2018
Resolution: Vessel provided updated charts
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 April 2018
Resolved
Vessel must provide updated light list and coast pilot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2018
Resolution: Vessel provided updated light list and coast pilot
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 16 April 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2018
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 April 2018
Resolved
Vessel must provide DOT approved alcohol test strips.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2018
Resolution: Vessel purchased DOT approved alcohol test strips
Documentation › Certificates/Documents › FCC SSL
Issued 16 April 2018
Resolved
Vessel must provide current FCC ship station license.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2018
Resolved 27 April 2018
Resolution: Vessel had current FCC ship station license
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2017
Resolved
Vesselt to provide updated charts onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 17 May 2017
Resolution: New chart purchased.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 May 2017
Resolved
Vessel to provide updated light list onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 17 May 2017
Resolution: New Light List provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 May 2017
Resolved
Provide unexpired burn cream, eye wash, and iodine swabs as per 46CFR160.041-4
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 17 May 2017
Resolution: New first-aid equipment provided.
Documentation › Certificates/Documents › FCC SSL
Issued 16 May 2017
Resolved
Master to provide FCC Operator License
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 31 May 2017
Resolution: Operator permit provided.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 May 2017
Resolved
Attached all lifefloat waterlights around the body of each lifefloat.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 31 May 2017
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 May 2017
Resolved
Replace expired and incorrect batteries in all floatlights onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 31 May 2017
Resolution: new batteries provided.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 May 2017
Resolved
Condemed 07 adult and 02 childrens KAPOK life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2017
Resolution: New lifejackets placed on board.
Stability › Watertight Integrity › General
Issued 16 May 2016
Resolved
Vessel had pipe penetrations and wire penetrations in the sewage void and lazaerette that were not watertight. Vessel is to make penetrations watertight to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 18 May 2016
Resolution: Repaired satisfactorily
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 May 2016
Resolved
Bilge alarm in the fwd void was not functioning properly. Vessle is correct wiring and ensure function of all bilge alarms.
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 18 May 2016
Resolution: Corrected bilge alarm