MAURY USCG vessel records Sign in
← All vessels

PRINCE OF SEAS

PRINCE OF SEAS is a 1993 freight ship. The Coast Guard has recorded 54 inspections since 1998, most recently in March 2024, along with 29 deficiencies and 6 operational controls.

Records from 1998 to 2024. Most recent: inspection, 26 March 2024.

Built
1993
Last inspected
26 March 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9014444 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3E2341
384576
Flag
PANAMA
—
Maury page id
psix-384576

Inspections, by type

…with no type recorded13
Years with a record 21 calendar years (1998–2024)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it6363 - Convention (Subpart B), Gross Ton
4297 - Convention (Subpart B), Net Ton
11384 - Displacement, Metric Ton
6849 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 54

26 March 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7885035
6 July 2023 PSC A · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7725611
29 November 2022 Deficiency Check · PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7599712
29 November 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7601456
18 May 2022 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7451864
25 April 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7437422
14 April 2021 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7172352
19 February 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7135767
13 March 2020 PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6924199
13 March 2020 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6926386
5 August 2019 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6761601
4 July 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6714482
5 March 2018 Damage Survey · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6366523
5 March 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6368607
22 February 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6358174
21 February 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6358824
21 February 2018 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6358828
9 January 2017 Administrative Inspection · COE-Offshore
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6067964
19 November 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6044251
21 October 2015 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5748752
26 December 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3916191
20 April 2009 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3456470
30 December 2008 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3386260
15 December 2008 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3380216
8 December 2008 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3376014
28 April 2008 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3194076
28 January 2008 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3137400
1 May 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2919579
20 April 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2911974
16 April 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2908560
9 April 2007 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2904127
2 February 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2865980
28 August 2006 MARPOL Annex I Examination · Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2762044
4 December 2005 PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2543651
20 November 2005 ISPS I Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2538574
19 November 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2540524
18 April 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2323961
11 April 2005 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2339576
28 March 2005 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2317814
18 March 2005 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2313866
11 March 2005 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2307862
6 January 2005 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2270189
4 January 2005 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2268471
24 December 2004 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2264402
20 December 2004 ISPS II Exam · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2262300
29 November 2004 ISPS II Exam · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2248134
22 November 2004 MARPOL Annex V Examination · ILO-147 Exam · Loadline Exam · ISPS II Exam · ISM Exam · Ballast Water Examination · PII Safety Exam · STCW 95 Exam · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2245746
10 November 2004 ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2239002
10 November 2003 Deficiency Check · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1944990
22 March 2003 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1761068
22 March 2003 In-Service Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1762169
11 June 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 291157
8 January 1999 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 424315
28 December 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 423880

Deficiency record · 29

09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 July 2023 Resolved
74 SOLAS (20) II-1/26.1- THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES, AND OTHER HAZARDS. PSCO OBSERVED MISSING MACHINERY GUARDS ON MAIN FIRE PUMP AND SEVERAL OTHER BILGE/MISC. PUMPS IN ENGINE ROOM.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2023
Resolved 18 July 2023
Resolution: PSCO observed proper guards in place.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 6 July 2023 Resolved
74SOLAS(20) V/19.2.5.20 ALLS HIPS OF 500 GROSS TONS AND UPWARDS SHALL, HAVE A GYRO COMPASS HEADING REPEATER OR OTHER MEANS, TO SUPPLY HEADING INFORMATION VISUALLY AT THE EMERGENCY STEERING POSITION IF PROVIDED; A GYRO COMPASS BEARING REPEATER. PSCO FOUND NO REPEATER IN STEERRING GEAR ROOM. CREW STATES THEY ARE TO REMOVE THE REPEATER FROM BRIDGE AND BRING AFT.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 March 2024
Resolution: PSCO observed gyrocompass repeater permanently installed in steering gear room during PSC B exam.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2022 Resolved
No more than 19 Liters of flammable liquids may be stowed in any machinery space. The flammable liquids must be in containers of 3.8 liters or less. PSCO observed 03 portable gas cans exceeding maximum limitation. 33CFR160.109 (46CFR147.147(c))
Action required: 10 - Deficiency Rectified
Due 29 November 2022
Resolved 29 November 2022
Resolution: Vessel moved containers to the paint locker.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 November 2022 Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society. PSCO observed fuel oil supply pipe with multiple soft patches and vent missing cover and vent. 74SOLAS(04)II-1/3-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2022
Resolution: Examined ventilation hood and fuel piping. Reviewed class approval for soft patches on pipe. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 February 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed STBD lifeboat was unable to start. Lifeboat was last tested on 11FEB21 without issues. The last record of maintenance was 04FEB21 when a battery needed to change.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2021
Resolution: Received Class Survey Report. The fuel oil supply line and fuel tank were cleaned. Fuel oil and fuel filer have been replaced. BV Surveyor tested the lifeboat engine and found operating as per manufacturer's spcification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 July 2019 Resolved
01-13102-THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED CONFORM WITH THE PROVUISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER OT THE SHIP OR PERSONS ON BOARD. [name withheld] PUMP ON #3 GENERATOR LEAKING FUEL OIL. - 74SOLAS (97) I/II - 60A
Action required: 60 - Rectify deficiencies prior to movement
Due 11 July 2019
Resolved 11 July 2019
Resolution: PSC NOLA RECEIVED CLASS REPORT SATISFYING THE REQUIREMENT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 July 2019 Resolved
02-13199-MEANS SHALL BE PROVIDED WHEREBY NORMAL OPERATION OF PROPULSION MACHINERY CAN BE SUSTAINED OR RESTORED EVEN THOUGH ONE OF THE AUXILIARIES BECOME UNRESPONSIVE. SPECIAL CONSIDERATION SHALL BE GIVEN TO THE MALFUNCTIONING OF THE FUEL OIL SUPPLY SYSTEM FOR ENGINES. PSC OBSERVED ONE FUEL OIL PURIFIER INOPERABLE AND CREW STATED THAT IT HAS BEEN BROKEN FOR OVER ONE MONTH. - 74SOLAS (97) II-1/26 - 40A
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2020
Resolution: Received class report# NOS0/2019/J5104 attesting to the replacement of the faulty fuel oil purifier with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 July 2019 Resolved
03-13199-HYDRAULIC POWER-OPERATED STEERING GEAR SHALL BE PROVIDED WITH THE FOLLOWING...A FIXED STORAGE TANK HAVING SUFFICIENT CAPACITY TO RECHARGE AT LEAST ONE POWER ACTUATING SYSTEM INCLUDED THE RESERVOIR WHERE THE MAIN STEERING GEAR IS REQUIRED TO BE POWER OPERATED. PSCO OBSERVED FIXED STORAGE TANK WAS EMPTY. - 74SOLAS (97) II-1/29.12.3-10C
Action required: 10 - Deficiency Rectified
Resolved 5 July 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 July 2019 Resolved
04-15109-THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. PSCO FOUND NO PROCEDURE TO ENSURE FIXED STORAGE TANK FOR STEERING SYSTEM IS KEPT FULL AS REQUIRED AND OUTLINED IN DEFICIENCY 3. - 74SOLAS (14) IX/3.1 ISM 10.1-50A
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2019
Resolved 11 July 2019
Resolution: PSC NOLA RECEIVED CLASS REPORT SATISFYING THE REQUIREMENT.
Operations/Management › Vessel Activity › Other
Issued 5 March 2018 Resolved
Whenever an accident occurs to a ship or a defect is discovered, the master or owner of the ship shall report at the earliest opportunity to the Administration, the nominated surveyor or recognized organization responsible for issuing the relevant certificate, who shall cause investigations to be initiated to determine whether a survey is necessary. The #1 STBD Derrick Boom had a catastrophic failure resulting in a marine casualty. 74SOLAS(14)I-11(c).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2018
Resolved 6 March 2018
Resolution: Received Class Report. See documents.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 5 March 2018 Resolved
Each rope on the embarkation ladder shall be continuous with no joints below the top step. All rope ends shall be secured to revent unraveling. Found the embarkation ladder in deteriorated condition, not fit for service. 74SOLAS(97)III-48.7.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2018
Resolved 6 March 2018
Resolution: Received class report. See documents.
Navigation › Piloting/Steering › Gyro Compass
Issued 2 January 2010 Resolved
1540-Gyro compass- Each vessel must have a working Gyro compass. Vessels Gyro compass is inoperable, causing the Auto-pilot to not work. Vessel must submit tech-report attesting to the proper operation of the Gyro compass and the Auto-pilot. 33CFR164.35(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2011
Resolution: Vessel submitted tech-report attesting to the proper operation of both the Gyro compass and the Auto-pilot. Necessary repairs were made to the Gyro compass, causing the Auto-pilot to function properly.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 December 2008 Resolved
Main engine seawater cooling line has a soft patch installed. Informed that repairs need to be made permanent as required.
Action required: 705 - Other - as specified
Due 8 January 2009
Resolved 30 December 2008
Resolution: Recieved BV class survey report stating repairs were conducted and satisfactorily tested.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 December 2008 Resolved
Two self closing doors were fitted with hold backs for rear entrance to the engine and steering gear room.
Action required: 705 - Other - as specified
Due 8 December 2008
Resolved 8 December 2008
Resolution: Hold back hooks were removed on the spot.
Lifesaving › Launching Appliances › Winch Brake
Issued 8 December 2008 Resolved
STBD lifeboat brake release cable allowing lowering form lifeboat is broken; as well cable allowing brake release from stern of lifeboat is broken.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 December 2008
Resolution: Cable and pulley were replaced and inspected. All Sat.
Deck/Cargo › Ballast › Piping
Issued 9 April 2007 Resolved
#2 Ballast pump supply line has a cement box patch fitted adjacent to the pump. Engineers have not notified the Master nor have parts been ordered.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2007
Resolved 1 May 2007
Resolution: Recieved class report from BV attesting to the temporary repairs made to ballast piping. All parts have been placed on order and will be delivered to vessel for permanant repairs by the end of May 2007.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 April 2007 Resolved
Area around ships service generators needs to be cleaned of oil/oily rags. Also lagging on stbd side eng. room adjacent to #3 generator is soaked with oil and needs replaced. To the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 April 2007
Resolution: Area cleaned and oily rags removed to the satisfaction of the attending Coast Guard Marine Inspector.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 28 August 2006 Resolved
Port and Starboard Lifeboats do not have enough water per person. Add more water to each lifeboat, about 60 liters per boat total prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2006
Lifesaving › Lifeboat › Propulsion Starting System
Issued 28 August 2006 Resolved
Life boat battery was dead and boat would not start. Replace battery prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2006
Lifesaving › Lifeboat › Handholds/Handrails
Issued 28 August 2006 Resolved
Port side lifeboat has broken grabrails and the starboard side of the boat. Repair prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2006
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 28 August 2006 Resolved
By the MSD, electrical wires were pulled out of the junction box. Repair wires and put back into junction box prior to the next US port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 September 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 22 November 2004 Resolved
Replace light covers in after steering where covers are missing as per SOLAS 74 Chap II-1 Reg 45.1.3
Condition: Unknown
Due 22 December 2004
Resolved 29 November 2004
Resolution: Light covers replaced.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 22 November 2004 Resolved
Have class attest to adequacy of the fire boundry door to the STBD freezer locker. Fire control plan shows door as an A-60 however door has holes passing through. Prior to 27 Dec 2004 as per Solas II-2 Reg 47
Condition: Unknown
Due 22 December 2004
Resolved 20 December 2004
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 22 November 2004 Resolved
Fire Control plan is missing the International Shore Connection. Have plan updated to indicate location of International Shore Connection as per SOLAS Chap II-2 Reg 20.
Condition: Design Flaw
Due 22 December 2004
Resolved 29 November 2004
Resolution: Fire Control Plan updated with International Shore Connection location.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 22 November 2004 Resolved
Remove Door Hold backs for all Self Closing Fire Doors (Non-automatic) as per SOLAS II-2 Reg 47.2.
Condition: Design Flaw
Due 22 December 2004
Resolved 29 November 2004
Resolution: Hold-backs for Self-closing doors have been removed.
Electrical › Electric Generation Source (emergency)
Issued 10 November 2003 Resolved
VESSEL'S BATTERY SET #1 FOR EMERGENCY GENERATOR WOULD NOT START THE GENERATOR, A VIOLATION OF SOLAS 74/78 CH II-1 REG 44/2. CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2003
Resolved 12 November 2003
Resolution: RECEIVED FAX COPY OF PURCHASE RECEIPT FOR REQUIRED BATTERIES. DEFICIENCY CLEARED.
Navigation › Piloting/Steering
Issued 22 March 2003 Resolved
Fix Gyro Compass to satisfaction of Flag/Class. LEGACY COMPONENT DESC: Gyro Compass
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 November 2003
Resolution: VERIFIED OPERATIONAL DURING AEF. DEFICIENCY CLEARED.
Fire Fighting
Issued 28 December 1998 Resolved
INTERNATIONAL SHORE CONNECTION IS MISSING GASKET, A VIOLATION OF SOLAS 74 CH II-2 REG 19-4. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 8 January 1999
Resolved 8 January 1999
Navigation
Issued 28 December 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 December 1998
Resolved 29 December 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.