Inspection history · 35
11 May 2026
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8354163
20 February 2026
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8305932
3 November 2025
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8269502
30 October 2025
Drydock Exam · Drydock Extension · Vessel Attendance · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8261070
12 September 2025
In-Service Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8234769
12 September 2025
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8236296
20 February 2025
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8058812
9 January 2024
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7846890
7 September 2023
Internal Structural Exam · Hull Examination · Drydock Extension · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7790371
31 July 2023
Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7757328
24 July 2023
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7751129
23 February 2023
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7622405
24 May 2022
DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7459506
31 January 2022
Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7388180
14 December 2021
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7368024
5 November 2021
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7348788
22 February 2021
MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7130164
16 December 2020
Periodic Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7116964
8 July 2020
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7072425
11 February 2020
COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6906701
18 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6876376
24 October 2019
MTSA Verification · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6839058
5 February 2019
MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6620054
6 December 2018
Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6592788
28 September 2018
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6564468
13 September 2018
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6536806
11 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6538167
20 August 2018
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6517877
1 March 2018
MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6360527
9 March 2017
MTSA Verification · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6082225
8 August 2016
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5966068
18 April 2016
Damage Survey
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5859088
5 April 2016
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5848559
8 March 2016
DAPI Audit · COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5829026
8 January 2016
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5794024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2026
Resolved
All vessels must be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment. The bilge pickup line in #1 void space was inoperable. Affect proper repairs to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2026
Resolution: Bilge pickup line was repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 February 2023
Resolved
Renew FCC Safety and Bridge to Bridge certs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2023
Resolved 8 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 February 2023
Resolved
Restencil PFD stowage as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2023
Resolved 15 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 23 February 2023
Resolved
Conduct satisfactory MOB/Boat Drill with Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2023
Resolved 2 March 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 February 2023
Resolved
Replace expired first aid kit items.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 25 February 2022
Resolved
Replace expired 1st aid contents of kit in Rescue Boat.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 3 March 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 February 2022
Resolved
Provide B-1 extinguisher in Rescue Boat.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 3 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 25 February 2022
Resolved
Add vessel name/identifier to Mustang suits used by crew in Rescue Boat ops.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 3 March 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2022
Resolved
Replace spanner wrench on F.S. #2.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 12 May 2022
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 25 February 2022
Resolved
Bridge steering panel- Extinguished lamp on Power Fail #2 (and panel test button sticks).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2022
08 - Alarms › N/A - No Subsystem › General alarm
Issued 24 February 2022
Resolved
Prove propoer operation of General Alarm on vehice deck, starboard side/fwd.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2022
Resolved 3 March 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 February 2021
Resolved
Address leaky valve on Fire Station #6 (Stem Leaks).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 31 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 February 2021
Resolved
Replace Expired Ring Buoy batteries and provide correct type/model battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 31 March 2021
14 - Pollution Prevention › 142 - MARPOL Annex II › Other (MARPOL Annex II)
Issued 22 February 2021
Resolved
Provide containment plugs for fuel vent containment on vehicle deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 31 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 February 2021
Resolved
Label work vests with vessel (or person) name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 31 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 February 2021
Resolved
Repair nozzle tip chains on Fire Stations #1 and #4.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 31 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 February 2021
Resolved
Provide IMO Symbols on lifesaving equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 31 March 2021
08 - Alarms › N/A - No Subsystem › General alarm
Issued 22 February 2021
Resolved
Prove operation of General Alarm is tank space forward of lazaret.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 31 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 February 2020
Resolved
The Heat detector did not work for the Emergency Genset space. Unit is HADs type that actuates a fixed CO2 system upon heat detection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2020
Resolved 16 March 2020
Resolution: Unit serviced/tested by Interstate Fire Co.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 October 2019
Resolved
Provide Markings on R/B: name of vsl on the bow, homeport on the transom, & capacity on the midship gunnel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 25 November 2019
Resolution: Done
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 24 October 2019
Resolved
Repair or replace the search light for the rescue boat.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 25 November 2019
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 October 2019
Resolved
Provide a service report for the fixed CO2 system for the Emergency Genset space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 25 October 2019
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 March 2019
Resolved
Open air receiver for internal inspection or hydro.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2019
Resolved 28 March 2019
Resolution: Done
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 March 2019
Resolved
Replace MDE and Genset keel cooler hoses with vacuum rated/reinforced hoses.
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 26 February 2020
Resolution: 835 cleared. Hoses to be replaced every 10 years to avoid having the change over to J1942 type hoses.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 28 February 2019
Resolved
Provides guards on baseboard heaters in ready room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2019
Resolved 28 March 2019
Resolution: Corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Overloading
Issued 28 February 2019
Resolved
Mark upper decks with maximum passenger capacity (90).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2019
Resolution: Done
08 - Alarms › N/A - No Subsystem › General alarm
Issued 28 February 2019
Resolved
Label General Alarm on starboard upper deck with required verbiage.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 April 2019
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 28 February 2019
Resolved
Conduct Fire and Boat Drills in the company of a USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 5 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 February 2019
Resolved
Conduct testing of exterior hoses/stations #1,#3,#6.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2019
Resolution: Done
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 February 2019
Resolved
Install junction box for CO2 pressure switch.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 April 2019
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 February 2019
Resolved
Repair alarm for low water cutout on boiler control panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2019
Resolution: Corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 February 2019
Resolved
Provide smaller relief valve and/or testing of control air receiver tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2019
Resolved 28 March 2019
Resolution: Done
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 February 2019
Resolved
Provide E-lightb that shines on escape scuttle of the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2019
Resolved 28 March 2019
Resolution: Done
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 January 2019
Resolved
Localized pitting was noted below the port shaft stuffing box, in 02 areas. A temp repair doubler was installed to allow vsl to operate until its next dry dock date. Hull plating to be renewed in this area at the next DDE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 September 2020
Resolved 20 July 2020
Resolution: Inspected, tested new plate inserts test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 September 2018
Resolved
Port bridge wing buoy to replace the grab line.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2018
Resolved 24 October 2019
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2018
Resolved
Remark the vsl's name on 05 PFDs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 October 2019
Resolution: Done
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018
Resolved
The vessel is currently broadcasting (1) Improper Call Sign. It should not be all 9’s.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2018
Resolved 24 October 2019
Resolution: Corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 1 March 2018
Resolved
Port MDE has an exhaust leak at first elbow as noted by lagging discoloration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 14 September 2018
Resolution: Replaced expansion belows on PORT MDE
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 1 March 2018
Resolved
Lube oil alarm and shutdown found inoperative on the embegency generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 13 September 2018
Resolution: Corrected
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 1 March 2018
Resolved
CO2 system pressure switches need to be relocated from the engine room to a protected space. To be completed during next DDX in Fall 2018.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 28 January 2019
Resolution: Relocated to the CO2 room
Engineering › Bilge Water Management System › Piping
Issued 1 March 2018
Resolved
Sections of bilge pipe forward IVO shaft packing found to be deteriorated. Gauge or replace section during next DDX in Fall 2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 28 January 2019
Resolution: Renewed all 3 bilge pipes in this space and tested SAT.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 10 March 2016
Resolved
Renew relief valves on pressure vessels 1-4 with A.S.M.E. approved relief valves stamped "UV" set to relieve below 200 psig, to include a hand lift device.
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 24 March 2016
Resolution: New relief vavles installed. #1 open 182/close 138, #2 175/132, #3 179/132, #4 184/135.
Communications › Alarms/Indicators › General Alarm
Issued 10 March 2016
Resolved
Label general alarm in ready room.
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 2 August 2016
Resolution: Attended vessel. Alarm is labeled.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 March 2016
Resolved
Label fire stations with station number.
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 2 August 2016
Resolution: Attended vessel. Stations are labeled.
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 March 2016
Resolved
Provide donning placards on second deck.
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 2 August 2016
Resolution: Attended vessel. Donning placrads in place.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 10 March 2016
Resolved
Repair starter on rescue boat.
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 11 March 2016
Resolution: Spare outboard motor installed and test ran satisfactorily.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 10 March 2016
Resolved
Pressure vessel #2 to remain secured until approved relief valve is installed and tested.
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 24 March 2016
Lifesaving › Launching Appliances › Davit
Issued 10 March 2016
Resolved
Mouse shackles on rescue boat davit.
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 2 August 2016
Resolution: Attended vessel. Shackles are moused.
Navigation › Piloting/Steering › Gyro Compass
Issued 10 March 2016
Resolved
Prove accuracy of gyro compass. Currently eight degrees error with magnetic compass.
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 2 August 2016
Resolution: Attended vessel. Sign is posted to advise operator of error.