07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 August 2025
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Marine Inspector identified that the Starboard Fuel Tank Compartment lacked sufficient vapor tight integrity surrounding cable penetrations.
46 CFR 177.405(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 August 2025
Resolution: Received satisfactory photos from operator.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 August 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine Inspector identified dead end wires from a previous piece of removed equipment in the overhead of the starboard fuel tank compartment.
46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2025
Resolution: Received satisfactory photos from operator.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 August 2024
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Drug & Alcohol swabs were not available, procure to MI statisfaction.
46 CFR 185.212
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2024
Resolved 16 August 2024
Resolution: MI observed new alcohol swabs sufficiently procured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 August 2024
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel name was faded on forward life ring, relabel to MI satisfaction.
46 CFR 185.604(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2024
Resolved 16 August 2024
Resolution: Forward life ring with faded lettering relabeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 August 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a)... provided that... The pump is permanently mounted;float switch in stbd center void did not operate automatically, ensure all pumps and float switches are permanently mounted and repair/replace float switch to the satisfaction of the MI.
46 CFR 182.520(e)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2024
Resolved 16 August 2024
Resolution: MI observed rectified working float switch and mounts were permanently installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 August 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew.... The port bow railing course was broken, repair to MI satisfaction.
46 CFR 177.900
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2024
Resolved 16 August 2024
Resolution: Port bow railing course was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 8 August 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. The means of securing engine room ventilation were missing velcro securing mechanisms.
46 CFR 182.465(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 9 September 2023
Resolution: Operator repaired ventilation covers to the satisfaction of the Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2023
Resolved
Piping of which the temperature exceeds 150 degrees F must be suitable insulated where necessary to prevent injuries. Port main engine turbo charger elbow missing insulation.
46 CFR 177.970
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 31 August 2023
Resolution: Insulation installed to the satisfaction of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 August 2023
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The port floating waterlight is inoperable. The vessel is restrict to daylight operations only until the waterlight is demonstrated operational to the satisfaction of the Marine Inspector.
46 CFR 180.175(f)(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2023
Resolved 21 August 2023
Resolution: Operator sent a video of water light operating properly. Video unable to be uploaded.
01 - Certificates & Documentation › 013 - Documents › Report of inspection on MLC,2006
Issued 8 March 2023
Resolved
Except for extensions as authorized by the Commandant, all vessels shall be drydocked or hauled out and made available for examination, and shall be examined by a marine inspector
within the periods set forth in this paragraph. Each vessel shall be drydocked or hauled out at intervals not to exceed 60 months if it operates exclusively in fresh water.
Dry Dock was due 28FEB2023. Operator has a dry dock scheduled for 14MAR2023
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2023
Resolution: Vessel completed credit drydock exam.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 7 June 2021
Resolved
Where liquid level indicating guages are installed they shall be provided at the tank connections with devices which will automatically close. MI found gauge level lines on the the fuel tanks without automatic shutoff devices.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 20 August 2021
Resolution: Sight glasses removed and capped. Mechanical gages installed from top of both fuel tanks.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 June 2021
Resolved
For fixed-gas fire extinguishing systems, If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Fireboy in the starboard engine compartment was not in serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 9 July 2021
Resolution: Sea Fire bottle removed and cleaned. Guage indicates bottle is in fully charged condition, and updated service report signed by GFS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 August 2020
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. MI observed several holes where previous cables, piping or existing cables go through bulkhead to another compartment. The following compartments were observed: engine compartment forward bulkhead starboard and port side, generator space outboard side, and bulkhead under pilot house.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2020
Resolved 19 August 2020
Resolution: VSL supported documentation/ pictures of corrective action by filling holes to make watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 July 2019
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Vessel's high level bilge alarm is not operational in the starboard fuel compartment.
46 CFR 182.530 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 1 November 2019
Resolution: Checked by a MI onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 July 2019
Resolved
Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry:
(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel's flares are expired. Vessel is restricted to daytime operations until proof of new flares is provided.
46 CFR 180.68 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 1 November 2019
Resolution: Checked by a MI onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 July 2019
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (3) The pump is permanently mounted. Vessel's bilge pump in the starboard midship space needs to be permanently mounted.
46 CFR 182.520(e)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 1 November 2019
Resolution: Checked by a MI onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 22 July 2019
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Vessel's starboard engine has an exposed belt. Provide a guard or other protection from the rotating belt.
46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 1 November 2019
Resolution: Checked by a MI onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 July 2019
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. One of the vessel's fire bucket was missing a lanyard. A lanyard was added.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 July 2019
Resolved 22 July 2019
Resolution: A lanyard was added to the fire bucket during the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 July 2019
Resolved
The following tests and inspections must be carried out weekly on a vessel: (a) Each survival craft, rescue boat, and launching appliance must be visually inspected to ensure its readiness for use. Vessel was missing the
life saving inspection log upon request. Inspector was provided with the inspection log prior to departing.
46 CFR 185.720 (a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 July 2019
Resolved 22 July 2019
Resolution: Inspector was provided with the inspection log prior to departing the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2019
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Vessel's high level bilge alarm is not operational in the starboard fuel compartment.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 20 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 February 2019
Resolved
Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry:
(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel's flares are expired. Vessel is restricted to daytime operations until proof of new flares is provided.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 20 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 February 2019
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (3) The pump is permanently mounted. Vessel's bilge pump in the starboard midship space needs to be permanently mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 20 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 27 February 2019
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Vessel's starboard engine has an exposed belt. Provide a guard or other protection from the rotating belt.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2019
Resolved 20 August 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 February 2019
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. One of the vessel's fire bucket was missing a lanyard. A lanyard was added.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 February 2019
Resolved
The following tests and inspections must be carried out weekly on a vessel: (a) Each survival craft, rescue boat, and launching appliance must be visually inspected to ensure its readiness for use. Vessel was missing the
life saving inspection log upon request. Inspector was provided with the inspection log prior to departing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 February 2019
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 11 June 2018
Resolved
Lack of vapor tight barriers in port starboard and port engine room bulkheads.
46 CFR 177.405(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 9 July 2018
Resolution: Used foam to make barriers vapor tight.
Electrical › Electric Supply System (service) › Cable
Issued 11 June 2018
Resolved
Zip ties were used to support cables instead of required metal fasteners.
46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 11 June 2018
Resolved 11 June 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 June 2018
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Stbd engine belt was not covered by a guard.
46 CFR 177.960
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 June 2018
Resolved 11 June 2018
Resolution: Vessel rep installed guard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 June 2017
Resolved
Vessel's stern light was inoperative upon inspection. Operator must prove proper operation of stern navigation light. 33 CFR 84
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 16 June 2017
Resolution: Operator provided documentation that attested to satisfactory repair.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 June 2016
Resolved
Route electrical cable in port engine compartment in a manner which does not contact steering arm.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 21 June 2016
Resolution: Electrical cable in port engine compartment routed in a manner which does not contact steering arm.
Engineering › Fuel Oil Service System › Hose
Issued 9 June 2016
Resolved
Replace starboard engine return fuel line and mount to prevent chafing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 16 June 2016
Resolution: Installed new USCG Type A-1 starboard engine return fuel line and mounted to prevent chafing.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 9 June 2016
Resolved
Replace port engine reduction gear linkage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 21 June 2016
Resolution: Installed new port engine reduction gear linkage.
Engineering › Bilge Water Management System › Hose
Issued 9 June 2016
Resolved
Replace starboard #4 compartment plastic bilge hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 16 June 2016
Resolution: Installed new plastic bilge hose in starboard #4 compartment