Inspection history · 37
17 June 2026
Annual Inspection · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8349649
18 June 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8077670
2 April 2025
Hull Examination · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7923307
13 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7907257
17 April 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7896877
15 March 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7872237
6 July 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7659856
24 May 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675538
21 April 2023
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7659843
20 October 2022
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7580854
20 October 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7595636
10 September 2022
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7555563
10 September 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7563965
16 August 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7534441
21 July 2022
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7513364
6 April 2022
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7403563
26 August 2021
Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7297392
24 August 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7326324
28 July 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7271582
18 July 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7259830
18 July 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7298335
6 July 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7247172
5 July 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7272984
1 April 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7167028
3 March 2021
Drydock Extension · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7157415
30 September 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7068528
21 July 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6913400
23 February 2020
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6919780
5 November 2019
Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6849988
23 July 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6732784
31 July 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6455857
21 May 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6414085
13 April 2018
Drydock Extension · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6383466
3 May 2017
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6127560
20 April 2017
Commercial Dive Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6119988
15 September 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5993427
10 March 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5824317
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 June 2025
Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150;. MI found 3 forward life buoys with degraded attached lines. Repair or replace.
46 CFR 180.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2025
Resolved 28 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 June 2025
Resolved
Gages to indicate engine... lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Prove proper operation of MDE Oil pressure gages in wheelhouse.
OLD-T 46 CFR 182.20-5(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 28 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2025
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements. MI identified exhaust leak coming from Port MDE #6 and #7 cylinders. Repair to the satisfaction of the attending [name withheld] 46 CFR 182.05-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 28 July 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 2 April 2025
Resolved
Replace window located port side near galley as id'd.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 16 April 2025
Resolution: Window replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 2 April 2025
Resolved
Replace window located on stbd side as id'd
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 16 April 2025
Resolution: Window repalced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 2 April 2025
Resolved
Replace windows in general seating area as id'd
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 16 April 2025
Resolution: Windows replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 April 2025
Resolved
Remove epoxy, other hazardous chemicals as id'd
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 16 April 2025
Resolution: Items removed from vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 April 2025
Resolved
Remove,clean and treat rot located outside galley near "Galley Cook Wanted"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 16 April 2025
Resolution: Rot wood removed, clean and treated.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 April 2025
Resolved
Remove, clean and treat rot located outside children's room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 16 April 2025
Resolution: Rot wood removed, cleaned and treated.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 June 2024
Resolved
AIS Class A device. The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: (i) A self-propelled vessel of 65 feet or more in length, engaged in commercial service. Vessels installed AIS receives but does not transmit. Prove proper operation of AIS transmission. 33CFR164.46(b) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 17 July 2024
Resolution: AIS replaced with new AIS.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 June 2024
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. If the storage cylinders are separate from the protected space, the instructions must also include a schematic diagram of the system and instructions detailing alternate methods of releasing the extinguishing agent should the local manual release or stop valve controls fail to operate. Local controls for CO2 release not marked with instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 17 July 2024
Resolution: Proper placards posted.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 July 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel does not have up to date charts.
46 CFR 184.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 15 July 2023
Resolution: Owner provided photos of new navigation charts.
09 - Working and Living Conditions › 091 - Living Conditions › Other (food)
Issued 20 October 2022
Resolved
Cooking and heating equipment must be suitable for marine use. Equipment designed and installed in accordance with American Boat and Yacht Council (ABYC) A-3, “Galley Stoves,” and A-7, “Boat Heating Systems,” or with National Fire Protection Association (NFPA) 302, “Pleasure and Commercial Motor Craft,” complies with this requirement. Following the electrical fire that occurred inside the galley oven: Repair/replace galley oven and have attending MI verify installation and operation prior to use while carrying passengers for hire. Vessel may also remove and discontinue use of any cooking equipment. While passengers are carried onboard, vessel is restricted from operating cooking equipment and shall lock out/tag out electrical source of power for such equipment at panel if hardwired into electrical circuit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 21 October 2022
Resolution: Attended vessel to verify proper installation of new oven
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2022
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. While mooring the vessel lost the stbd main propulsion engine. Vessel was able to dock safely. Vessel must prove proper operation of the stbd main propulsion engine prior to movement. 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 July 2022
Resolution: Performed peir side and underway test. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 July 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions.
DC generator failed resulting in a loss of propulsion.
Vessel operator to prove satisfactory condition (i.e. fitness for service) of the DC generator. DC generator is not to be utilized while passengers are onboard and/or while operating under the vessels Certificate of Inspection.
To rectify this deficiency vessel operator must demonstrate proper function/operation of the DC generator to the assigned USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2021
Resolved 28 July 2021
Resolution: Valve leading to oil pressure sensor was replaced due to not providing consistent flow, causing the generator to struggle and go offline.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 23 July 2019
Resolved
A VESSEL MUST BE OPERATED IN ACCORDANCE WITH APPLICABLE LAWS AND REGULATIONS AND IN SUCH A MANNER AS TO AFFORD ADEQUATE PRECAUTION AGAINST HAZARDS THAT MIGHT ENDANGER THE VESSEL AND THE PERSONS BEING TRANSPORTED. DISCOVERED ROTTED WOOD ON 03 STRUCTURAL MEMBERS SUPPORTING APPROXIMATELY 15' OF FREE STANDING PORTION OF THIRD DECK. CONDUCT DAMAGE ASSESSMENT AND PROVIDE SATISFACTORY REPAIR PROPOSAL.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 7 August 2019
Resolution: Repairs effected to satisfaction of attending Coast Guard Marine Inspector.
Communications › Audible Communications › Bell
Issued 15 September 2016
Resolved
Install bell of at least 300 mm in diameter.
Action required: 705 - Other - as specified
Due 16 October 2016
Resolved 3 May 2017
Resolution: Vessel had secondary means of sound signal.
Construction/Loadline › Hull › Hull Plating
Issued 11 April 2016
Resolved
Replace hull planking on port quarter; as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 14 April 2016
Resolution: (01) plank was renewed as indicated.
Construction/Loadline › Hull › Side Shell
Issued 11 April 2016
Resolved
Sand/grind 2 areas of hull planing on the port quarter; as indicated, to enable inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 14 April 2016
Resolution: (02) area on the port quarter identified were removed as they were on the same plank and the plank was renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 8 April 2016
Resolved
Replace frame on stbd side in hot water tank space; as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 14 April 2016
Resolution: Frame was renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 8 April 2016
Resolved
Replace frame on stbd side fwd in day tank space; as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 14 April 2016
Resolution: Frame was renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 8 April 2016
Resolved
Replace frames (05) total stbd side laz; as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 14 April 2016
Resolution: (05) frames on the stbd side laz renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 8 April 2016
Resolved
Replace planking on transom; as indicated ensuring proper spacing & location of butts; as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 18 April 2016
Resolution: Vessel completed all required work to the transom of the vessel.
Construction/Loadline › Hull › Transverse Frame
Issued 8 April 2016
Resolved
Crop to good wood frame & planking stbd side aft engine room; as indicated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 14 April 2016
Resolution: Vessel cropped to good wood, renewed and treated area.
Construction/Loadline › Hull › Bottom Plating
Issued 8 April 2016
Resolved
Crop, renew & treat areas of delignification &/or wood rot in the following areas; as indicated. chain locker port side, bow thruster fwd stbd side, bow thruster aft stbd side, hot water tank space stbd side, dish washer space stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 18 April 2016
Resolution: Vessel completed work to the areas identified.
Construction/Loadline › Hull › Bottom Plating
Issued 8 April 2016
Resolved
Sand/grind on external of hull to good wood as indicated, in order to identify rotted planking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 14 April 2016
Resolution: areas indentified were taken to good wood & inspected, sat.
Construction/Loadline › Hull › Bottom Plating
Issued 8 April 2016
Resolved
Remove epoxy and filled hull planking in order to make identified areas on external of hull available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 14 April 2016
Resolution: areas were made available for inspection.
Construction/Loadline › Hull › Keel
Issued 8 April 2016
Resolved
Provide USCG a list of sea valves, size, types & locations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 18 April 2016
Resolution: Vessel provided well documented list of valves inspected with location.
Construction/Loadline › Hull › Transverse Frame
Issued 8 April 2016
Resolved
Provide USCG with a list of all frames renewed or repaired, with location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 18 April 2016
Resolution: Vessel supplied drawings and detailed list of work completed in yard.