Records from 1993 to 1998. Most recent: inspection, 14 January 1998.
Electrical
Issued 13 January 1998
No resolution recorded
MISSING LIGHT COVERS IN ENGINEROOM._x001C_ _x001C_ SOLAS 60 REG II/27(a)_x001C_
Condition: Unknown
Due 13 February 1998 — due date passed with no resolution recorded
Navigation
Issued 3 August 1996
Resolved
DEMONSTRATE PROPER OPERATION OF STEERING GEAR SYSTEM. PORT UPPER RAM IS PRESENTLY LEAKING EXCESSIVELY.
Condition: Unknown
Due 4 August 1996
Resolved 8 August 1996
Navigation
Issued 3 August 1996
Resolved
PROVE THAT CURRENT RADAR IS IN COMPLIANCE WITH IMO PERFORMANCE STANDARDS FOR AUTOMATIC RADAR PLOTTING AIDS (ARPA) PRIOR TO NEXT U.S PORT._x001C_ _x001C_ 33CFR164.38
Condition: Unknown
Due 14 January 1998
Resolved 14 January 1998
Construction/Loadline
Issued 6 December 1995
Resolved
DOGS MISSING AND GASKETS DETERIORATED ON CARGO HOLD ENTRANCE HATCHES. MAKE REPAIRS PRIOR TO DEPARTURE. ILLC II REG 18.2
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Lifesaving
Issued 6 December 1995
Resolved
PROVIDE PROVISIONS, EQUIPMENT, CANOPY AND FRAMING FOR PORT AND STARBOARD LIFEBOATS AND PROPERLY STOW PRIOR TO DEPARTURE. SOLAS 60 III.11
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Navigation
Issued 6 December 1995
Resolved
PROVIDE BLOCK DIAGRAM OPERATING INSTRUCTIONS FOR STEERING GEAR CHANGE OVER IN STEERING COMPARTMENT. COMPLETE PRIOR TO DEPARTURE. 33 CFR 164.35(k)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Fire Fighting
Issued 6 December 1995
Resolved
FIRE HOSE STATIONS; DOORS WIRED SHUT, NOZZLES AND SPANNER WRENCHES MISSING THROUGHOUT VESSEL. CORRECT PRIOR TO DEPARTURE. SOLAS 60 II.56
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Fire Fighting
Issued 6 December 1995
Resolved
REPAIR EXHAUST LEAK AND LAGGING FOR EMERGENCY FIRE PUMP AND PROVE PROPER OPERATION PRIOR TO DEPARTURE. SOLAS 60 II.65_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Electrical
Issued 6 December 1995
Resolved
REPAIR LIGHTING IN FOSCLE ENTRANCE TO EMERGENCY FIRE PUMP COMPARTMENT. COMPLETE PRIOR TO DEPARTURE. SOLAS 60 II.23
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Deck/Cargo
Issued 6 December 1995
Resolved
REPAIR HYDRAULIC LEAKS TO CARGO HOLD HYDRAULIC SYSTEM AND MOORING EQUIPMENT. PRIOR TO DEPARTURE. 33 CFR 151.10
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Navigation
Issued 6 December 1995
Resolved
Excessive leakage of steering gear hydraulic piping/pumps. make permanent repairs prior to departure. SOLAS 60 II.29
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Construction/Loadline
Issued 6 December 1995
Resolved
PORT AFT SEACHEST VENT LINE LEAKING AFTER SKIN VALVE. MAKE PERMANENT REPAIRS PRIOR TO DEPARTURE. ILLC II REG 22_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Engineering
Issued 6 December 1995
Resolved
MAIN ENGINE CYLINDER COOLERS PIPING HAVE PIN HOLE LEAKS. MAKE PERMANENT REPAIRS PRIOR TO DEPARTURE. SOLAS 60 II.28
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Accommodation/Occupational Safety
Issued 6 December 1995
Resolved
SEWAGE TANK PORT SIDE AFT AND ASSOCIATED PIPING WASTED AND LEAKING. MAKE PERMANENT REPAIRS PRIOR TO DEPARTURE. 33 CFR 159
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Electrical
Issued 6 December 1995
Resolved
SHIP SERVICE GENERATORS; COOLING SUPPLY LINE TO TURBO CHARGER OF STBD GEN LEAKING, ALSO THE F/O RETURN LINES NEED TO BE RECONNECTED AND EXHAUST LAGGING REINSTALLED. MAKE REPAIRS PRIOR TO DEPARTURE. SOLAS 60 II.23
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Lifesaving
Issued 6 December 1995
Resolved
REMOVE EXCESSIVE OIL FROM ENGINEROOM BILGES PRIOR TO DEPARTURE._x001C_ 33 CFR 155_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Deck/Cargo
Issued 6 December 1995
Resolved
CARGO HOLD HATCH COVER DOGGING POINTS DAMAGED. MAKE REPAIRS PRIOR TO DEPARTURE. ILLC II REGS 15 & 16
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Construction/Loadline
Issued 6 December 1995
Resolved
FOSCLE WTD MISSING DOGS. REPAIR PRIOR TO DEPARTURE. ILLC II REG 18.2
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Construction/Loadline
Issued 6 December 1995
Resolved
BALLAST TANKS IN #3 & 4 CARGO HOLDS ARE LEAKING INTO HOLDS STBD SIDE. COMPLETE REPAIRS PRIOR TO DEPARTURE. ILLC II REG 14.1
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Engineering
Issued 6 December 1995
Resolved
RENEW CONTAINMENT AT BUNKERING STATION PORT SIDE AND INSTALL CONTAINMENT AROUND L/O TANK VENTS. COMPLETE PRIOR TO DEPARTURE. 33 CFR 155.310_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Engineering
Issued 6 December 1995
Resolved
MAIN ENGINE COOLING AND BALLAST PUMPS EXCESSIVE LEAKAGE AT PACKING GLANDS. MAKE PERMANENT REPAIRS PRIOR TO DEPARTURE. SOLAS 60 II.28
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Construction/Loadline
Issued 6 December 1995
Resolved
REPAIR WARPED HATCH COVER LEADING FROM MAIN DECK TO ENGINEERING SPACE BELOW, PORT SIDE. COMPLETE PRIOR TO DEPARTURE. ILLC II REG 18.2
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Lifesaving
Issued 6 December 1995
Resolved
STOW ALL OIL DRUMS LOCATED ON EXPOSED MAIN DECK AREAS. COMPLETE PRIOR TO DEPARTURE. SOLAS 60 II.29
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Accommodation/Occupational Safety
Issued 6 December 1995
Resolved
REPAIR MUSHROOM VENT CLOSURES ON FANTAIL PORT AND STBD, VENTS WASTED AND NOT OPERATIVE. COMPLETED PRIOR TO DEPARTURE. ILLC II REG 19.1
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Accommodation/Occupational Safety
Issued 6 December 1995
Resolved
SUPERSTRUCTURE EXTERIOR BLKHDS WASTED AND HOLED THROUGHOUT SUPERSTRUCTURE._x001C_COMPLETE REPAIRS PRIOR TO DEPARTURE. ILLC II REG 11
Condition: Unknown
Due 4 January 1996
Resolved 4 January 1996
Navigation
Issued 19 February 1993
Resolved
US COAST GUARD LIGHT LIST OR FOREIGN EQUIVALENT NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Navigation
Issued 19 February 1993
Resolved
BLOCK DIAGRAM OPERATING INSTRUCTIONS FOR STEERING GEAR CHANGE OVER NOT DISPLAYED ON BRIDGE AND STEERING GEAR COMPARTMENT.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Unknown
Issued 19 February 1993
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Engineering
Issued 19 February 1993
Resolved
POLLUTION PLACARD NOT POSTED.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Navigation
Issued 19 February 1993
Resolved
US COAST PILOT OR FOREIGN EQUIVALENT NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995