Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it6 - Regulatory (Subpart C or D), Gross Ton 4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 20 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 November 2024Resolved
The master of a vessel, except a vessel listed in § 185.502(a) of this part, shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Vessel needs to implement a passenger count system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2024
Resolved 20 November 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 November 2024Resolved
At least one ring life buoy must be fitted with a lifeline. Each lifeline on a ring life buoy must:
(1) Be buoyant;
(2) Be of at least 18.3 meters (60 feet) in length;
(3) Be non-kinking;
(4) Have a diameter of at least 7.9 millimeters (5/16 inch);
(5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and
(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light.
During manoverboard drills, vessel fouled both props with LRB lifeline and required cutting. LRB needs lifeline prior to operating commercially.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2024
Resolved 20 November 2024
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 14 October 2021Resolved
A penetration in a watertight bulkhead must be made water/gas tight. A pre-engineered fire extinguishing system is installed in the machinery space. Cabling runs through the forward bulkhead in an opening that is not water/gas tight. Marine grade foam must be applied to meet this requirement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 18 October 2021
Resolution: Access hole in watertight bulkhead was filled with approved marine grade foam.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 October 2019Resolved
Provide copy of written company Drug and Alcohol Policy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 31 October 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 October 2019Resolved
Provide evidence of Supervisor and Employee training for Drug and Alocohol Program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 31 October 2019
Engineering › Fuel Oil Service System › Hose
Issued 7 September 2016Resolved
Replace all fuel lines with approved Type as per 46 CFR 182.700(e)
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 10 January 2017
Resolution: Replaced all fuel lines with approved type.