13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2026
Resolved
An excessive amount of hydraulic fluid discovered pooled below the elevator motor. Make repairs within 7 Days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2026
Resolved 20 April 2026
Resolution: Confirmed cleaned and system integrity intact by MI
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 July 2025
Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who:(1) Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection...Marine employers will randomly select a sufficient number of covered crewmembers for testing during each calendar year to equal an annual rate not less than the minimum annual percentage rate for random drug testing determined by the Commandant.
Vessel does not maintain current DAPI list. Last random chemical test was performed in March 2024.
Update DAPI crew list and perform random chemical test.
46 CFR 16.230 (a-g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2025
Resolved 18 September 2025
Resolution: Received updated DAPI list. Verified with medical center, current list on file and last Random Drug Test performed on 6 AUG 2025
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 28 July 2025
Resolved
All crew spaces are to be constructed and arranged in a manner suitable to the purpose for which they are intended and so that they can be kept in a clean, workable, and sanitary condition.
Observed broken glass on mirrors on 2nd deck dance floor.
46 CFR 72.20-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 12 August 2025
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 28 July 2025
Resolved
Electric installations on vessels must ensure... Protection of passengers, crew, other persons, and the vessel from electrical hazards.
Observed missing panel with exposed electrical wires at the 3rd deck bar.
46 CFR 71.15-1
46 CFR 111.01-1(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 12 August 2025
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 28 July 2025
Resolved
Electric installations on vessels must ensure... Protection of passengers, crew, other persons, and the vessel from electrical hazards.
Observed electrical receptacle unsecured, hanging from bulkhead in the 2nd deck forward dining room on the port side and 2nd deck dance floor.
46 CFR 71.15-1
46 CFR 111.01-1(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 17 September 2025
Resolution: Received photographic evidence.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2025
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable.
Observed missing overhead panels on the 3rd deck, located forward on the starboard side.
46 CFR 72.03-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 17 September 2025
Resolution: Received photographic evidence.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 28 July 2025
Resolved
Electric installations on vessels must ensure... Protection of passengers, crew, other persons, and the vessel from electrical hazards.
Observed emergency light socket hanging from the soffit and missing bulb in the forward stairwell between 2nd and 3rd deck.
46 CFR 71.15-1
46 CFR 111.01(a) (2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2025
Resolved 17 September 2025
Resolution: Received photographic evidence.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 31 March 2025
Resolved
At each annual inspection, the inspector must ensure that the following tests and inspections of fire detection and extinguishing equipment have been conducted. Vsl did not have all fire extinguishers on board and galley fire suppression system was under maintenance. Provide maintenance servicing report attesting to all fire extinguishers and fire suppression system serviced and in working condition.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2025
Resolution: Received objective evidence via tech servicing report, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 March 2025
Resolved
All doors shall be capable of operation from either side by 1 person. The forward door leading to the anchor does not latch. Make repairs to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 28 July 2025
Resolution: MIs verified door is operable.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 31 March 2025
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Various lifebouy markings and retro tape were deteriorated. Ensure all lifebouys are ready for immediate use in accordance with 46 CFR 199.70(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 12 May 2025
Resolution: Vsl submitted objective evidenance via pictures for the lifebouy markings, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2025
Resolved
Each vessel must carry a lifejacket for each person on board, and in addition a number of lifejackets suitable for children equal to at least 10 percent of the total number of passengers on board. Vessel was missing 15 children lifejackets. Reduce the number of children carried until lifejackets are replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2025
Resolved 12 May 2025
Resolution: Vsl submitted objective evidenance via pictures for the correct amount of childerens lifejackets, sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 March 2025
Resolved
The annual inspection shall include an inspection of the structure, boilers, and other pressure vessels, machinery and equipment. Noticed damaged to the following areas:
1. Rub rail and lower handrail on transom near the port quarter were damaged
2. Bow handrail near anchor winch was damaged
Submit repair proposal to the local OCMI for approval. Prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 22 April 2026
Resolution: Verified as complete.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 February 2025
Resolved
At least three reinspections shall be made on each vessel within one year. These reinspections will be made at approximately equal intervals between annual inspection. Vessel has canceled the third quarter reinspection and requires a new COI inspection to carry passengers.
46 CFR 71.30-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2025
Resolution: Conducted COI inspection on 31MAR2025
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 October 2024
Resolved
Licenses for ship stations in the maritime services will normally be issued for a term of ten years from the date of original issuance, or renewal. Vessel FCC license certificate was expired.
47 CFR 80.25(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2024
Resolved 15 November 2024
Resolution: Vsl rep submitted new FCC Radio Station Cert, sat
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 25 October 2024
Resolved
Each vessel must have posters or signs displayed in the vicinity of each survival craft and the survival craft's launching controls. Vessel did not have posters or signs illustrating how to deploy liferafts onboard.
46 CFR 199.90
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2024
Resolved 27 November 2024
Resolution: Received photograph of launching instructions post, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 October 2024
Resolved
Nonmetallic expansion joints must conform to the standards listed in table 2 to 56.60-1. Nonmetallic expansion joints may be used within their specified pressure and temperature rating in vital and nonvital machinery sea connections inboard of the skin valve. Raw water system expansion joint on the #3 SSDG has reach the end of its service life.
46 CFR 56.35-10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2024
Resolved 1 April 2025
Resolution: Inspected newely installed expansion joints.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 October 2024
Resolved
Reverse-power and reverse-current trips. Each generator arranged for parallel operation must have reverse-power or reverse-current trips. Reverse power relay on #3 SSDG inop.
46 CFR 111.12-11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2024
Resolved 1 April 2025
Resolution: Tested newely installed reverse power relay during COI inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 July 2024
Resolved
Each inflatable life saving appliance must be serviced within 12 months of each subsequent servicing. 4(50 person) life rafts are a month past their servicing date. Vessel pax count will be reduced by 200 until servicing is complete.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 July 2024
Resolution: Owner provided proof of servicing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2024
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. The port bridge wing ring buoy grab lines are damaged and in need of replacement.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2024
Resolved 31 July 2024
Resolution: The owner provided proof of replacement.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 16 July 2024
Resolved
Deck wiring or schematic plans of power systems and lighting systems must be approve. Vessel had temporary power leads wired into a distribution panel for DJ equipment in the accommodation space on the 3rd deck stbd side aft. Remove.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 July 2024
Resolution: Wiring was removed prior to conclusion of the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 July 2024
Resolved
Each generator must be protected by a Circuit Breaker meeting the requirements of Subpart 11.12.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2024
Resolved 1 April 2025
Resolution: Tested newely installed breaker during COI inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 March 2024
Resolved
Bilge system deemed inoperable during inspection. System shall be capable of pumping from and draining water from required spaces. Demonstate proper operation per the above from multiple spaces prior to acceptance of current arrangement. 46 CFR 71.25-35(a), 46 CFR 56.50-50(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 March 2024
Resolved
Fire Station #4 & Fire Station #2 did not have their hose nor spanner wrench on station during the exam. Outfit each of the respective fire stations as required.
Action required: 705 - Other - as specified
Due 8 April 2024
Resolved 1 April 2024
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 20 July 2023
Resolved
Vessel's sprinkler system flow indicator alarms (zone M-2 main deck casino stbd 7 high limit room stbd, zone 2-2 second deck stbd side main casino, and main deck port zone m-1) did not operate as designed plus one had an allen wrench shoved into it to trick the system; the vessel is restricted from operating with passengers until system is working and verified by a CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2023
Resolved 24 July 2023
Resolution: 21July2023: Received and accepted video and statement from vessel rep [name withheld], of the sprinkler alarm system being in good order.
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 20 July 2023
Resolved
Vessel has two CO2 bottles used for soda dispersement in the bars which is not mounted and could cause a safety hazard, must properly mount CO2 bottles when in use and storage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2023
Resolved 17 October 2023
Resolution: It was sttaed by operator thathey will no longer be using tap soda and will only be suring bottled soada so CO2 bottles have been removed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 July 2023
Resolved
Two fire stations (upper deck fwd & 2nd deck IWO anchor station) that were missing the required spanner wrenches; must provide one spanner wrench as per regulations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2023
Resolved 17 October 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 27 April 2023
Resolved
VESSEL SHALL OFFLOAD ALL EFFECTED HAZARDOUS MATERIAL WASTE TO A CERTIFIED FACILITY. VESSEL SHALL CLEAN & GAS-FREE ALL EFFECTED TANKS/PIPING. PRIOR TO CLEARING DEFICIENCY, CG MI SHALL CONDUCT VISUAL INSPECTION OF EFFECTED TANKS/PIPING. VESSEL SHALL ISOLATE EFFECTED TANKL/PIPING AND NOT PERMITTED TO CONTINUE OPERATIONS OF EFFECTED TANK/PIPING UNTIL CG CONDUCTS VISUAL INSPECTION.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 6 June 2023
Resolution: Visited the vessel at Pert Amboy for sewage tank inspection. Reviewed Chemist certificate for both tanks prior to entering, and inspected both tank for cleanliness; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 April 2023
Resolved
WHILE CONDUCTING A STEERING TEST, THE #1 STEERING PUMP MOTOR CAUGHT FIRE MAKING THE PUMP INOPERABLE. MI CONDUCTED NUMEROUS SATISFACTORY STEERING TESTS ON THE #2 EMERGENCY STEERING PUMP. VESSEL IS PERMITTED A ONE TIME [name withheld] TO OPERATE IN THE VICINITY OF THE STATUE OF LIBERTY ONLY, WITH A TUG ASSIST. VESSEL OPERATOR IS REQUIRED TO SUBMIT A SATISFACTROY TUG ASSIST PLAN THROUGH SECNY VTS. FOR PASSENGER OPERATIONS BEYOND 04/22/2023, VESSEL MUST SUBMIT SATISFACTORY REPAIR PLANS, CONDUCT SATISFACTORY REPAIRS, CONDUCT A SATISFACTORY OPERATIONAL TEST, AND CONDUCT A SATISFACTORY MAN OVERBOARD DRILL FOR CG REVIEW/APPROVAL.
Action required: 705 - Other - as specified
Resolved 27 April 2023
Resolution: Conducted operational tests of newly installed steering pump motor. Conducted satisfactory man overboard drill.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 April 2023
Resolved
A receptacle outlet must not have any exposed live parts with the plug opening uncovered, outlet in way of the #6 fire extinguisher is broken and needs to be replaced.
46CFR111.79-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 21 April 2023
Resolution: MI witnessed satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 April 2023
Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space (other than a paint locker). Nothing in this subpart shall be construed as limiting the inspector from making inspections as necessary to be assured of the safety of the vessel. Remove the wastes oil and the containers from under ladder port side in the storeroom off of crew lounge.
46CFR71.25.50
46CFR147.45
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 21 April 2023
Resolution: Vessel removed all containers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 April 2023
Resolved
Nothing in this subpart shall be construed as limiting the inspector from making inspections as necessary to be assured of the safety of the vessel. Clean behind the passenger elevator controls outside just aft of galley clean the oil and trash so not to cause a fire.
46CFR71.25-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2023
Resolved 21 April 2023
Resolution: MI inspected behnd the elevator controls, all clean/sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 April 2023
Resolved
Doors leading from engine room are not properly closing or latching, doors and are not self-closing and remain open. Demonstrate that the doors can close properly. Doors, other than those which are normally locked, such as from staterooms, fan rooms, lockers, etc., shall be of the self-closing. (Cleared)
46CFR72.05-25(b)(9)(i)
Action required: 10 - Deficiency Rectified
Due 17 April 2023
Resolved 17 April 2023
Resolution: Def clear while MI conducted COI exam
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 April 2023
Resolved
Prior to movement demonstrate proper operation of sprinkler system and demonstrate in the presence of an attending Marine Inspector that various heads and zones are not clogged, and water flows freely through the pipe through the heads. In addition, demonstrate that alarms and that the system operates as designed.
46CFR76.01-2
NFPA 13 CH25
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2023
Resolution: Conducted satisfactory inspection for vessel's sprinkler system.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage comminuting and disinfecting system
Issued 17 April 2023
Resolved
Vessel has a Type III Marine Sanitation Device which is considered certified provided sole use is storage of sewage and flush water. Marine Inspector discover oil water in toilet in the “Marine Operations Managers Head” port side IWO frame 74-77 engine room deck. Thus, making the MSD tank not certified. The complete sewage system must be freed of all oil traces, prior to going back in operation. All oily water, contaminated water, to include sewage, must be properly contained on board the vessel. If the containment to include holding tanks for sewage and waste oil are exceeded, the vessel must coordinate the off load with USCG
33CFR159.12a
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2023
Resolution: MI inspected toiler. No found oily water inside. Sewage system has been freed of all oil traces.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 March 2023
Resolved
In general, at least three re-inspections shall be made on each vessel within one year. These re-inspections will be made at approximately equal intervals between annual inspections. Vessel operator has not requested or made vessel available for re-inspection, last inspection was completed 14NOV2022. Operator shall make vessel available to USCG Marine Inspector prior to operating with passengers. You must submit your application CG–3752 for the inspection at least 30 days in advance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2023
Resolution: Vessel conducted COI inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 August 2022
Resolved
An individual may not be engaged or employed, including self employment, on a vessel in a position as master, operator, or person in charge for which a credential is required by law or regulation unless all crewmembers covered by this regulation are subject to the random testing requirements of this section. Provide up to date list of persons enrolled in random chemical testing program. 46 CFR 16.230(k)
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 August 2022
Resolved 14 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 August 2022
Resolved
Where extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation must meet the requirements of this part. Fire control panel was displaying a trouble alarm. Provide servicing report attesting to a satisfactory working detection system. 46 CFR 76.01-5(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 August 2022
Resolved 6 September 2022
Resolution: provided report
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 August 2022
Resolved
The lifejackets stowage position must be marked with the words "LIFEJACKETS" or "CHILD LIFEJACKETS" as appropriate. Starboard bow sundeck lifejacket stowage locker was not labeled. 46 CFR 199.70(b)(2)(iii)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2022
Resolved 6 September 2022
Resolution: sent pictures
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 April 2022
Resolved
The intent of the annual inspections to insure that the vessel and other equipment is in satisfactory condition and fit for the service for which it is intended:
(a)On the Sundeck, the bar is in needed of repair as there are sharp areas, nail sticking out and broken glass. Before the bar can be used the bar needs to be serviced/repaired prior to use.
(b)Found 2 half tables that can easily fall over. Ensure the half tables are secured to the bulkheads as they inherently top heavy and easily fall over.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 April 2022
Resolved
At each annual inspection, the inspector shall test automatic fire dampers to determine that they are in an operable condition. The fire dampers on main deck pantry is blocked by dishes/glasses, clear the area to make access to dampeners and demonstrate the operation of the dampers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 April 2022
Resolved
Remove the top row of boxes stored in the passageway leading to the CO2 station, so in the event of a fire the sprinkler system will reach behind the boxes/shelves, as there shall be 18” of clearance between the top of storage and ceiling sprinklers. (NFPA 13)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2022
Resolved
Before the vessel leaves port each lifesaving appliance must be ready for immediate use:
(a) The ring buoy line, for the aft port side iwo e-gen, is being used to tie the door open. Properly mount life ring and make for immediate use.
(b)Remove and replace the 02 un-serviceable life ring buoys identified on the 2nd deck bow and 2nd deck aft.
(c)Replace ring buoy light line on 2nd deck to be between 3-6feet in length, UV resistant and be attached around the body of the life ring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 14 November 2022
Resolution: Verified items corrected
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2022
Resolved
In engine room store rooms/ offices, remove the flammables from the rooms. As no flammable or combustible liquids may be stowed in any accommodation, control, or service space (other than a paint locker).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 April 2022
Resolved
All piping, valves, and fittings of ferrous materials shall be protected inside and outside against corrosion. Currently installed piping unions used in the fixed CO2 system are not galvanized to protect against corrosion and shall be replaced as identified and reported by SEA SAFETY technician in their inspection certificate dated 18APR2022.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 15 November 2022
Resolution: provided tech report on 5/20/22
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 April 2022
Resolved
Each carbon dioxide extinguishing system altered after July 9, 2013, must have an approved odorizing unit to produce the scent of wintergreen. “Altered” means modified or refurbished beyond the maintenance required by the manufacturer's design, installation, operation and maintenance manual. Consequently from above
deficiency number 09, when the pipe unions in the fixed CO2 system are replaced this would be considered an alteration beyond the regular maintenance required by manufacturer. Thus warranting the installation of an approved odorizing unit as required by 46 CFR 76.15-60.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 15 November 2022
Resolution: provided tech report on 5/20/22
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2022
Resolved
Correct the identified cracked or stuck grounding prong
electrical outlets to minimize electrical hazards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 April 2022
Resolved
The intent of the annual inspections to insure that the vessel, and other equipment is in satisfactory condition and fit for the service for which it is intended. Presently and over the past several inspections the vessels elevators have been taken out of service due to various failures. Due to theses failures, before all the elevators onboard the vessel can be used to carry any person (crew or passenger), provide proof from an Elevator Inspection Contractor licensed by the state of New Jersey or New York that the elevators meet ASME A17.1-2019: Safety Code for Elevators and Escalators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 14 November 2022
Resolution: Elveators runing somothly
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 April 2021
Resolved
Remove SSI lock combinations from ship's log.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 April 2021
Resolved
Provide records for security equipment maintenance.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 April 2021
Resolved
Provide list of crew members enrolled in DAPI.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 April 2021
Resolved
Post EAP information for crew.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2021
Resolved
Replace dry rotted plug on bridge wing port side ring buoy.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 April 2021
Resolved
Provide documentation for weekly lifesaving inspections.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 April 2021
Resolved
Provide documentation for general alarm tests.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 19 April 2021
Resolved
Demonstrate proper operation of flanking rudder angle indicator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2021
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 19 April 2021
Resolved
Conduct fire drill.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 April 2021
Resolved
Replace emergency lighting on sun deck, port side, aft that is burned out.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
09 - Working and Living Conditions › 091 - Living Conditions › Dirty, parasites
Issued 19 April 2021
Resolved
Provide invoice from exterminator for rodent control.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 April 2021
Resolved
Portable fire extinguishers must be numerically labeled to correspond with their numeric location on the fire control plan.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 19 April 2021
Resolved
Tighten railing corner at the turn of the stairway from the 3rd deck to the sun deck.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 April 2021
Resolved
Repair inop flood lights for liferafts at the second deck.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 April 2021
Resolved
Sprinklers that are pushed up into the ceiling on the 3rd deck must be repaired to allow for proper diffuser functionality.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 April 2021
Resolved
Provide elevator servicing certificate.
Action required: 705 - Other - as specified
Due 2 June 2021
Resolved 26 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 August 2020
Resolved
46 CFR 199.190(g) Liferaft annual servicing overdue.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2020
Resolution: Deferred until further notice; vessel not in service.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 August 2020
Resolved
33 CFR 64.11 (r) the (steering gear) equipment is maintained in operable condition. Follow-up control (primary means of steering) is inoperable from the main conning position on the navigation bridge. Vessel is required to make permanent repairs and conduct sea trials under the observation of a Coast Guaard Marine Inspectorprior prior to passenger service.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2020
Resolution: See tech report
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 August 2020
Resolved
46 CFR 199.180(c) Drills - general.
(1) Drills must, as far as practicable, be conducted as if there were an actual emergency.
(2) Every crewmember must participate in at least one abandon-ship drill and one fire drill every month. The drills of the crew must take place within 24 hours of the vessel leaving a port if more than 25 percent of the crew have not participated in abandon-ship and fire drills on board that particular vessel in the previous month.
NO DRILLS HAVE BEEN CONDUCTED. PRIOR TO PAX, VESSEL MUST CONDUCT MOB, FIRE AND SECURITY DRILLS WITH CREW.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2020
Resolution: Drills deferred; no crew to perform drills
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 August 2020
Resolved
§ 104.410 Submission and approval
(c) The Commanding Officer, Marine Safety Center (MSC), will examine each submission for compliance with this part, and either -
(1) Approve it and specify any conditions of approval, returning to the submitter a letter stating its acceptance and any conditions;
VESSEL OWNER COULD NOT PROVIDE PROOF OF ASP ACCEPTANCE LETTER. LETTER MUST BE KEPT ON BOARD FOR INSPECTOR REVIEW.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2020
Resolution: Provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2020
Resolved
78.33-5 Accidents to machinery.
(a) In the event of an accident to machinery tending to render the further use of the item unsafe until repairs are made, or if by ordinary wear such items become unsafe, a report shall be made immediately to the Officer in Charge, Marine Inspection, or if at sea, immediately upon arrival at port.
#1 MDE outboard crankcase cover leaking oil. Repair immediately (deficiency carried over from COI inspection).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2020
Resolution: Repaired by local contractor
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 August 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 February 2020
Resolved
Fire Pump has a weld that is leaking, make permanent and proper repairs to the leak on the pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2020
Resolved 5 March 2020
Resolution: Received picture and receipt showing the new pipe section.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2019
Resolved
46 CFR 4.06-3 - Missing alcohol testing devices. Must have enough for entire crew following a SMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 20 November 2019
Resolution: Verified enough onboard for entire crew following an SMI
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2019
Resolved
46 CFR 16.230a.1 - Update eligible crew list for DAPI program
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 20 November 2019
Resolution: Provided documentation
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 21 October 2019
Resolved
46 CFR 199.40.f.1 - Install guard on outbaord motor
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 20 November 2019
Resolution: Installed guard
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 October 2019
Resolved
46 CFR 199.60 - Replace and ensure correct amount available to crew during an emergency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 20 November 2019
Resolution: Not required on River route; if onbaord must be non-expired and serviceable
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 October 2019
Resolved
46 CFR 76.60-10 - replace bracket and remount axe on upper deck bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 20 November 2019
Resolution: Due to inherent risk of having an axe accessible to passengers, operators authorized to keep axe in the piothouse.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 October 2019
Resolved
33 CFR 104.265.f.4 - watchstander did not check our IDs before boarding vessel
Action required: 10 - Deficiency Rectified
Due 21 October 2019
Resolved 21 October 2019
Resolution: Educated watchstander on protocol regardless of uniformed service members boarding vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 21 October 2019
Resolved
46 CFR 71.45 - Excess grease found on galley floor
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 20 November 2019
Resolution: Galley cleaned to the satisfaction of teh attending MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2019
Resolved
46 CFR 111.01-1a.2 - live wires found above dance floor
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 20 November 2019
Resolution: Wires removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2019
Resolved
46 CFR 111.01-1a.1 - Fix broken light fixture in closet on 3rd deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 20 November 2019
Resolution: Fixture repaired
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 October 2019
Resolved
56.20-9 - Replace valve handle in E/R
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 20 November 2019
Resolution: Handle replaced
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 October 2019
Resolved
46 CFR 76.25-15 - Sprinkler pump leaking, requires packing to rectify
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 20 November 2019
Resolution: Leak secured
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 July 2019
Resolved
Each liferaft must be arranged to permit it to drop directly into the water from the deck on which it is stowed. Aft liferafts on the port and starboard sides of the deck are impeded from dropping directly into the water by the passenger railing. Remove railing that would impede liferaft from direct drop overboard without compromising passenger safety and the intent of the railing to prevent MOB situations.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 August 2019
Resolved 19 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2019
Resolved
Lifebouys on vessel with light must be self-igniting. Replace/repair light on port side bridge wing of vessel.
Action required: 705 - Other - as specified
Due 19 August 2019
Resolved 19 August 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 April 2019
Resolved
Replace burned out bulbs for e-lighting between second and third deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 15 May 2019
Resolution: Loose bulb
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 April 2019
Resolved
Fire boundaries around area of safe refuge must be a class 'A' boundary. Replace plastic window separating accomodation space and area of safe refuge with proper class 'A' window IAW fire control plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2019
Resolved 15 May 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 November 2018
Resolved
Ventilation system was spot checked and several areas were dirty and filters were clogged. Clean out ventilation areas as discussed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 November 2018
Resolution: Attended vessel, verified ventilation system was cleaned.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 November 2018
Resolved
Pressure gauging on topping off tank gauge is not working and needs to be replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2018
Resolution: Attended vessel, verified replacment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2018
Resolved
A vessel that has automatically or remotely controlled or monitored vital systems addressed by part 46 CFR 62 must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. The vessel has no test or inspection procedures (Periodic Safety Test Procedure) ***Provide copy by 15 December 2018***
Action required: 705 - Other - as specified
Due 15 December 2018
Resolved 11 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 October 2018
Resolved
Vessels # 3 ship service generator is not operational, once repairs have been made and then prior to carrying passengers, the vessel must go through a survey such as to insure that the necessary repairs or renewals have been effectively made.
*** After repairs, before carrying passengers***
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 20 July 2018
Resolved
Pipe, tubing, pipe joining fittings, and piping system components shall meet material and standard requirements of subpart 56.60 and shall meet the certification requirements of part 50 of this sub-chapter. The vessel has a pinhole leak its its jacket water pipe for the No. 2 SSDG. Prove proper repairs to the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2018
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 20 July 2018
Resolved
Fire pumps shall be fitted with a pressure gauge on the discharge side of the fire pump. Pressure gauge is inconsistent and unable to read. Demonstrate proper operation of pressure gauge for fire pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2018
Resolved 25 July 2018
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 July 2018
Resolved
Sufficient illumination must be provided by the emergency lighting source under emergency conditions to provide safe egress. Emergency lighting in stairway from engine room flickers. Demonstrate proper operation of emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2018
Resolved 25 July 2018
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 20 July 2018
Resolved
All water tight doors (WTD) shall be kept closed during navigation except when necessary for working on the vessel, and in such cases they shall always be ready to be immediately closed. Replace missing cotter pin in WTD leading into engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2018
Resolved 25 July 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 July 2018
Resolved
For all types of stairways, sufficient handrails shall be fitted. Tighten handrail leading from the hurricane deck to the O-3 deck forward.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2018
Resolved 25 July 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2018
Resolved
The frame or support of each fire extinguisher must be welded or otherwise permanently attached to a bulkhead or deck. Fire bracket on O-1 deck, starboard quarter, is broken. Replace broken fire bracket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2018
Resolved 25 July 2018
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 July 2018
Resolved
The inspector shall examine the tank tons and bilges in the machinery spaces to see that there is no accumulation of oil which might create a fire hazard. Oil was identified in void space between engine room and lazarette. Remove oil in bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2018
Resolved 25 July 2018
Accommodation/Occupational Safety › Ventilation › General
Issued 4 May 2018
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. Vessel reported that a damper shut on the #2 generator, causing the generator to overheat and produce sparks and smoke. Prior to carrying passengers, vessel shall clean and/or replace exhaust piping and make available for inspection by a Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2018
Resolved 25 July 2018
Electrical › Electric Generation Source (service) › Generator
Issued 4 May 2018
Resolved
A survey, eith general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered. The Captain of the Port is allowing this vessel to board passengers at the pier, stay pier-side while the passengers are on board the vessel for an event on the evening of 06May2018. In the event that the ship's service generator malfunctions and the ship's emergency generator takes the loas, all passengers shall be disembarked, and the Coast Guard shall be notified. The previous 02 CG-835V's are still in effect.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 July 2018
Resolution: Load test and safety shutdowns were witnessed.
Electrical › Electric Generation Source (service) › Generator
Issued 9 April 2018
Resolved
SSDG#3 is not operational and being repaired. Make repairs and perform operational test prior to being placed back in service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2018
Resolution: This was re-issued
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 February 2018
Resolved
Vessel has missed the 2nd and 3rd re-inspections (quarterlies). Prior to carrying passengers must have a credit COI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2018
Resolution: Completed COI
Personnel › Training › Passenger Safety
Issued 17 October 2017
Resolved
Vessel did n ot have the proper number of crew to conduct drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2017
Resolved 20 October 2017
Resolution: CG MIs attended vessel and conducted a satisfactory fire and man overboard drills.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 25 July 2017
Resolved
Bar on second deck has a drain problem causing flooding of grey water on 1st deck & enlisted dining room which is an un-sanitary condition, must clean and repair pipe.
Due 1 August 2017
Resolved 17 August 2017
Resolution: Wasted pipe was replaced with new.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 July 2017
Resolved
Passenger elevator doors are off track and broke plus this elevator overheats causing it to shut down, must repair/replace all parts to original design. Must not use with passengers until cleared by CGMI
Due 25 August 2017
Resolved 25 July 2018
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 July 2017
Resolved
Remove items IWO port storage room in the Star room electrical panel.
Due 8 August 2017
Resolved 17 August 2017
Resolution: Area was cleared.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 25 July 2017
Resolved
Repair/replace closure to the 2nd deck fire door #5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2017
Construction/Loadline › Structures › Door
Issued 25 July 2017
Resolved
Repair/replace main deck aft stbd door latch and handle.
Due 8 August 2017
Resolved 17 August 2017
Resolution: Door latch replaced.
Accommodation/Occupational Safety › Potable Water System › General
Issued 25 July 2017
Resolved
Re-install hydro-pneumatic head tank relief valve.
Due 8 August 2017
Resolved 17 August 2017
Resolution: Relief valve replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 25 July 2017
Resolved
Identify and repair oil leak on starboard main engine (left hand bank).
Due 8 August 2017
Resolved 17 August 2017
Resolution: Oil leak repaired by replacment of two gaskets.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 April 2017
Resolved
All Fire Doors shall be of a type which are capable of release from the control station and from a position at the door (remote and locally) 46 CFR 72.05-25(b)(8)(ii).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2017
Resolution: Verified proper release and closure of all FSD from control station release.
Engineering › Bilge Water Management System › Not Operational
Issued 10 April 2017
Resolved
Vessel required to conduct suction test prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2017
Resolution: Verified suction of bilge system.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 10 February 2017
Resolved
Condition: Improper Installation
Due 14 April 2017
Resolved 10 April 2017
Resolution: Vessel installed loss of power alarm for fire detection system. Operationally test and sat.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 25 October 2016
Resolved
Vessel does not have secondary power supply for their fire detection panel
Condition: Improper Installation
Due 28 November 2016
Resolved 24 March 2017
Resolution: emergency generator will serve as the back up power as long as the power failure alarm is functioning.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 24 October 2016
Resolved
Vessel does not have approved test procedures
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 November 2017
Resolved 15 October 2018
Resolution: This was re-issued
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 27 July 2016
Resolved
No proof of annual elevator servicing certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 30 July 2016
Resolution: Provided proof of annual servicing.
Lifesaving › Rescue Boat › Construction
Issued 27 July 2016
Resolved
Rescue boat cradle is not secured and freely rolls about the deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 27 August 2016
Resolution: Wire secured to rails/deck.
Lifesaving › Inflatable Liferafts › Servicing
Issued 22 July 2016
Resolved
Liferaft servicing for #6 raft is past due.
Condition: Improper/Lack of Maintenance
Due 3 August 2016
Resolved 27 July 2016
Resolution: Provided new servicing certificate and photos of installation.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 July 2016
Resolved
Vessel has an unauthorized repair on the saltwater cooling line for the A/C system. Vessel must submit a repair proposal for approval prior to making repairs. 46CFR71.55-1
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 20 September 2016
Resolution: Vessel replaced pipe with new sch 40 ASTM A53 pipe using existing flanges with is a repalcement "in kind".
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 14 April 2016
Resolved
#3 gen did not trip while conducting the over speed test.46CFR111.12-1(b) "old J"(1982-1996)
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 22 July 2016
Resolution: Tested satisfacory during the first quarterly exam.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 April 2016
Resolved
Motor controller for steering gear system does not have an elementary wiring diagram
46CFR111.70-3(h)(2) "old J" 1982-1996
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 11 May 2016
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 14 April 2016
Resolved
Vessel has 05 emergency exit lights that do not illuminate correctly during emergency power
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2016
Resolved 16 April 2016
Resolution: Owner provided documentation of proepr illumination of emergency exit signs during all modes of power.
Navigation › Piloting/Steering › Marine Charts
Issued 14 April 2016
Resolved
Vessel does not have corrected and updated charts for intended areas of operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2016
Resolved 16 April 2016
Resolution: Owner provided documentation of corrected and updated charts on the vessel.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 14 April 2016
Resolved
Rudder angle indicator for vessel's flanking rudders is inoperable.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 11 May 2016
Resolution: Witnessed in operation by attending Marine Inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 14 April 2016
Resolved
Vessel did not have annual servcing report for portable fire extinguishers onboard.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 24 October 2016
Construction/Loadline › Hull › Side Shell
Issued 28 January 2016
Resolved
Vessel is going through extensive repairs to the port side shell in way of the main engine exhaust system. In addition the vessel has plans to go through its required dry docking. Prior to the vessel retuning to passenger service. The vessel must complete a full Certificate of Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2016