Records from 1993 to 2004. Most recent: inspection, 19 February 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 40
19 February 2004
Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2024861
16 October 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 179821
8 December 1995
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1407588
30 November 1995
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1186453
2 November 1995
Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 880856
31 October 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 66956
6 October 1995
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1430119
14 September 1995
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 883276
22 June 1995
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1371152
6 June 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 59709
16 April 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 118093
11 April 1995
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1160485
11 April 1995
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1417791
31 March 1995
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1145470
22 March 1995
Damage Survey · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1135933
21 March 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 5319
21 February 1995
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1158379
11 January 1995
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1396251
4 January 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 118966
28 December 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 697649
15 December 1994
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 838607
14 December 1994
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 866372
13 December 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 55609
23 November 1994
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1466384
11 October 1994
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 854374
11 August 1994
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1414337
11 July 1994
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1173519
2 May 1994
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1389841
9 April 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 149109
23 March 1994
Damage Survey · Examination of Repairs
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1382733
17 March 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 118323
14 March 1994
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1166919
21 February 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 137503
12 January 1994
Initial Certification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1377120
27 December 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1358244
17 December 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1162942
14 December 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 179870
14 December 1993
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428294
10 December 1993
Initial Construction-Excluding Oversight · Hull Examination · Deadweight Survey · Deficiency Check · Permit to Proceed
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354520
8 April 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1146238
Accommodation/Occupational Safety
Issued 2 November 1995
Resolved
Maintain passenger control and warning tape to prevent passengers from occupying damage railing on refuge deck; also provide permanent repairs notthan 16NOV95. _x001C_
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Electrical
Issued 6 October 1995
Resolved
Complete the following general wiring requirements: a. remove deadend 30 ftblack coiled wire in Cellular Communication Room, b. replace orange extension cord with hard/permanent wiring in Cell Comm Rm, & c. hard wire air compressor in main deck aft liquor locker.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Fire Fighting
Issued 6 October 1995
Resolved
Mount dry chemical portable fire extinguisher no. D6 in computer room.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Documentation
Issued 6 October 1995
Resolved
Provide documentation that pressure vsl (air compressor) in main deck aft liquor locker meets ASME construction standards or replace with P/V that does meet ASME stds or remove from vsl._x001C_ _x001C_
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Accommodation/Occupational Safety
Issued 6 October 1995
Resolved
Remove all waste paper baskets that do not have solid sides and are of non-combustable material constuction; 46 CFR 72.05-55.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Electrical
Issued 6 October 1995
Resolved
Install protective cover on STBD side PCU cabinet cooling fan._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Navigation
Issued 6 October 1995
Resolved
Prove proper operation of sound powered phone call from aft steering to pilothouse.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Electrical
Issued 22 June 1995
Resolved
Properly repair wall outlet and install cover on junction in overhead in State surveillance office.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Construction/Loadline
Issued 22 June 1995
Resolved
Prove proper operation of #6 Class 3 sliding Watertight Door._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 June 1995
Resolved 2 August 1995
Construction/Loadline
Issued 22 June 1995
Resolved
Complete repairs on solenoid control valve and prove proper operation of #3Class 3 sliding Watertight door._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 June 1995
Resolved 2 August 1995
Lifesaving
Issued 22 June 1995
Resolved
Prove proper operation of navigation panel alarms.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Engineering
Issued 22 March 1995
Resolved
Determine cause of stern thruster drive shaft failure and extent of damage to stern thruster unit. Make permanent repairs to stern thruster to the satisfaction of [name withheld], IL.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Fire Fighting
Issued 21 February 1995
Resolved
CHANGE RING CHARACTER (BELL SOUND) OF 3RD DECK SLOT MACHINE JACKPOT BELL TOBE DISTINGUISHABLE FROM THE GENERAL ALARM BELL, NOT LATER THAN 21 MARCH 1995.
Condition: Unknown
Due 21 February 1995
Resolved 21 February 1995
Fire Fighting
Issued 11 January 1995
Resolved
Install correct size and classification of portable fire extinguishers in accordance with 46 CFR Table 76.50-10(a).
Condition: Unknown
Due 25 January 1995
Resolved 23 February 1995
Documentation
Issued 11 January 1995
Resolved
Amend Fire & Safety Plan to show accurate location of required (and extra) portable fire extinguishers.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Construction/Loadline
Issued 11 January 1995
Resolved
Recharge accumulator tanks for #2 & #3 sliding Watertight Door.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Electrical
Issued 11 January 1995
Resolved
Make proper wiring connections in elevator control cabinets using UL approved compression type terminals. Provide proper closure to cabinet doors.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Accommodation/Occupational Safety
Issued 11 January 1995
Resolved
Remove employee embarkation stairway in way of 2nd deck, port side, egress doorway; or provide amended emergency evacuation plan approved by USCG Marine Safety Center.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Fire Fighting
Issued 11 January 1995
Resolved
Make necessary piping, valve, pressure tank and pump changes on auto sprinkler system to coincide with (CG) approved plans. In interim, isolatesystem's pressure reserve tank.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Electrical
Issued 11 January 1995
Resolved
Provide affidavit of tests of MAW and emergency generator alarms and shutdowns.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Electrical
Issued 11 January 1995
Resolved
Prove proper setting of ship's service generator overspeed trips.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Documentation
Issued 11 January 1995
Resolved
Provide most recent annual certificate of inspection for all 3 elevators.
Condition: Unknown
Due 25 January 1995
Resolved 23 February 1995
Accommodation/Occupational Safety
Issued 23 November 1994
Resolved
Properly repair fractured threshhold and properly adjust door closure devices on main deck STBD amidships doorway.
Condition: Unknown
Due 14 December 1994
Resolved 6 January 1995
Construction/Loadline
Issued 23 November 1994
Resolved
Demonstrate proper operation of #3 Water Tight Door (sliding) in Engineering Office (inadequate nitrogen charge).
Condition: Unknown
Due 17 January 1995
Resolved 18 January 1995
Electrical
Issued 23 November 1994
Resolved
Demonstrate proper operation of #1 ship's generator reverse power relay.
Condition: Unknown
Due 14 December 1994
Resolved 6 January 1995
Construction/Loadline
Issued 23 November 1994
Resolved
Properly install wiring and stuffing tube over #2 sliding Watertight Door.
Condition: Unknown
Due 14 December 1994
Resolved 6 January 1995
Lifesaving
Issued 11 October 1994
Resolved
Until vessel has full compliment of liferafts onboard, number of persons isnot to exceed 1250.
Condition: Unknown
Due 23 November 1994
Resolved 6 January 1995
Navigation
Issued 2 May 1994
Resolved
Prove proper operation of permanent navigation lights on stern mast.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Navigation
Issued 2 May 1994
Resolved
Calibrate rudder angle indicator in after steering.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Navigation
Issued 2 May 1994
Resolved
Prove satisfactory operation of navigation lighting panel audible alarm.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Navigation
Issued 2 May 1994
Resolved
Prove proper operation of radar.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Electrical
Issued 12 January 1994
Resolved
Provide acceptable means, and prove proper installation of motor control cabinet temperature alarms and indicators.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Engineering
Issued 12 January 1994
Resolved
Provide proper illumination for moter RPM indicators.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Engineering
Issued 12 January 1994
Resolved
Prove proper calibration of all control station ammeters.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Engineering
Issued 12 January 1994
Resolved
Prove proper adjustment of set points and time delay for current knockdown device.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Electrical
Issued 12 January 1994
Resolved
Properly secure all discrete components in all PMSCU cabinets.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Accommodation/Occupational Safety
Issued 12 January 1994
Resolved
Eliminate large gap in starboard elevator threshold.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Accommodation/Occupational Safety
Issued 12 January 1994
Resolved
Properly secure handrails in stairtower.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Electrical
Issued 12 January 1994
Resolved
Prove paddle wheel motor covers to be watertight
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Fire Fighting
Issued 12 January 1994
Resolved
Properly modify AEVAD system to comply with NVIC 8-93 in regard to operation and sounding of general alarms and recording and time delay.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Electrical
Issued 12 January 1994
Resolved
Relocate general alarm fuse panel 2nd deck fwde/ovhd in accordance with 46 CFR 113.25-8(c) and (e)
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Construction/Loadline
Issued 12 January 1994
Resolved
Provide continuous seal around engine control room escape scuttle.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Lifesaving
Issued 12 January 1994
Resolved
Properly install and prove operation of general alarm and PA system on fwd exterior decks.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Electrical
Issued 12 January 1994
Resolved
Provide temperature detectors for ships service generators #1 through #4 for obtaining sttionary winding temps. per ABS Rules for Building and Classing of Steel Vessels, Section 35.25.7
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Construction/Loadline
Issued 12 January 1994
Resolved
Provide mapping of locations of all power driven fasteners on the vessel, and remove power driven fasteners and repair damage to framing to provide compliance with MSM Vol II.18.0. Until all repair complete monitor all locations for propagation of cracks on weekly basis.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Fire Fighting
Issued 12 January 1994
Resolved
Provide fire extinguishing system for ships service generators #1 through #4, suitable for extinguishing fires in electrical equipment per ABS Rules for Building and Classing of Steel Vessels, Section 35.25.8.(b)
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Engineering
Issued 12 January 1994
Resolved
Provide over speed protection for each of the main propulsion motors as perattached ABS letter.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Unknown
Issued 12 January 1994
Resolved
Provide approved incombustible trashcans.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Electrical
Issued 12 January 1994
Resolved
Prove adequacy of electric cable under pilot house or replace with approvedflexible cable per 46 CFR Subchapter J.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Fire Fighting
Issued 12 January 1994
Resolved
Properly install recessed sprinkler heads in all locations with low overheads.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Electrical
Issued 12 January 1994
Resolved
Provide resistor distance of 12 inches to insulation in all motor control cabinets.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Electrical
Issued 12 January 1994
Resolved
Properly support cable conduit for elevator hydraulic pump motors in thruster rooms forward and aft.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Accommodation/Occupational Safety
Issued 12 January 1994
Resolved
Provide test certificates for 3ea. elevators
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Engineering
Issued 12 January 1994
Resolved
Prove proper operation of paddle wheel RPM indicators.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Navigation
Issued 10 December 1993
Resolved
PROVIDE TO THE SATISFACTION OF THE COGNIZANT [name withheld]_x001C_ MSC COMMENT LETTER M-30558 DATED 21 SEPTEMBER 1993, ITEM 1.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Accommodation/Occupational Safety
Issued 10 December 1993
Resolved
TIGHTLY PACK OPEN END OF BEVERAGE CONDUIT AND SEAL WITH APPROVED FIRE STOP AT TERMINATION POINT INSIDE CENTER CABINET, IN-WAY OF MAIN DECK BAR.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Accommodation/Occupational Safety
Issued 10 December 1993
Resolved
PROVE INSTALLATION OF FUSIBLE LINKS IN DAMPNER CONTROL OF BOTH OUTBOARD VENTILATORS, MAIN DECK LEVEL AFT TO THE SATIFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Electrical
Issued 10 December 1993
Resolved
INSTALL APPROPRIATE COVERS OVER ALL RECEPTACLES AND SWITCH BOXES.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Accommodation/Occupational Safety
Issued 10 December 1993
Resolved
INSULATE BACK AT LEAST 12 INCHES THE BEVERAGE CONDUIT WHERE IT PENETRATES THE FORWARD BULKHEAD OF THE BEVERAGE ROOM.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Electrical
Issued 10 December 1993
Resolved
PROVIDE ADEQUATE ARRANGEMENTS INWAY OF THE HYDRAULIC MACHINERY SPACE BELOW_x001C_THE PILOT HOUSE TO KEEP THE ELECTRICAL WIRING FROM FALLING ON AND AROUND_x001C_ THE PILOT HOUSE HYDRAULIC PUMP/MOTOR SO AS NOT TO CAUSE CHAFING OF THE _x001C_ WIRING.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Electrical
Issued 10 December 1993
Resolved
PROVIDE ELECTRIC GRADE DECK COVERINGS MEETING MIL-M-15562 AT LEAST 36 INCHES WIDE IN FRONT OF THE SWITCHBOARD.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Documentation
Issued 10 December 1993
Resolved
PRIOR TO OPERATION AS PASSENGER CARRYING VESSEL PRESENT TO THE COGNIZANT_x001C_ OCMI A STABILITY LETTER ISSUED BY THE MARINE SAFETY CENTER.
Condition: Unknown
Due 24 December 1993
Resolved 24 December 1993
Documentation
Issued 10 December 1993
Resolved
OBTAIN FOR TRANSMITTAL TO [name withheld] (MSC) HEIGHT OF FINSISHED CEILING_x001C_ ABOVE DOOR IN CREW LOUNGE IN PRESENCE OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Documentation
Issued 10 December 1993
Resolved
SUBMIT FOR APPROVAL TO THE COGNIZANT [name withheld].
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Lifesaving
Issued 10 December 1993
Resolved
PROVE PROPER OPERATION OF ALL GENERAL ALARM BELLS.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Accommodation/Occupational Safety
Issued 10 December 1993
Resolved
INSTALLATION OF THE VAULT ROLL-UP DOOR SHALL BE TO THE SATISFACTION OF THE_x001C_COGNIZANT OCMI.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Documentation
Issued 10 December 1993
Resolved
UPON COMPLETION TO SATISFACTION OF THE COGNIZANT OCMI OF UNDER-WAY TRIALS_x001C_ PRESENT FOR APPROVAL VESSELS PERIODIC TEST PROCEDURE.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Electrical
Issued 10 December 1993
Resolved
CLEAN CONTACT BREAKER FOR PORT #1 CHILLER UNIT.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Engineering
Issued 10 December 1993
Resolved
INSTALL ONBOARD IN THE WHEELHOUSE A ILLUMINATED INDICATOR THAT SHOWS WHEEL_x001C_SPEED AND DIRECTION OF ROTATION._x001C_ (46CFR113.37-5&-10)
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Navigation
Issued 10 December 1993
Resolved
REPAIR TWO (02) LEAKING FITTINGS IN-WAY OF THE HYDRAULIC STEERING PIPING.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Electrical
Issued 10 December 1993
Resolved
INSTALL LIGHT BULBS IN ALL FIXTURES CONTAINED WITHIN THE COLUMNS CONNECTED TO THE UPS EMERGENCY POWER SYSTEM.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Deck/Cargo
Issued 10 December 1993
Resolved
INSTALL PEAR LINK TO MAKE ANCHOR CONNECTION VICE TWO (02) SHACKELS.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Lifesaving
Issued 10 December 1993
Resolved
PROVE OPERATION OF TRAINABLE EMBARKATION LIGHTS FOR LIFERAFTS IAW 46 CFR _x001C_ 75.50-15.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Accommodation/Occupational Safety
Issued 10 December 1993
Resolved
PROVE OPERATION OF THE THREE (03) ELEVATORS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Lifesaving
Issued 10 December 1993
Resolved
REPLACE WINCH'S ON BOTH RESCUE BOAT DAVITS WITH THOSE DESIGNED FOR LIFTING.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Lifesaving
Issued 10 December 1993
Resolved
PROVE OPERATIONAL INTERFACE BETWEEN THE AUTOMATIC EMERGENCY VOICE ALARM ANDDIRECTIONS SYSTEM (AEVADS), PUBLIC ADDRESS SYSTEM, SOUND SYSTEM AND SATISFYTHE G-MTH-2 COMMENT LETTER 16715/AEVADS DATED 09 DECEMBER.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Fire Fighting
Issued 10 December 1993
Resolved
PROVE HEADROOM CLEARANCE TO THE SPRINKLER HEADS, TO THE SATISFACTION OF THECOGNIZANT OCMI.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Lifesaving
Issued 10 December 1993
Resolved
REPLACE ALL NONMETALLIC FLEXIBLE HOSES NOT LISTED IN SAE J-1942 PER 46CFR 56.65-1(c). AN AFFIDAVIT OF CONSTRUCTION PROVING COMPLIANCE WITH SAE J-1942STANDARDS MUST BE PROVIDED FOR ANY NON-LISTED HOSES._x001C_
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Electrical
Issued 10 December 1993
Resolved
INSTALL CURRENT LIMITING DEVICES IN EACH PROPULSION POWER SEMICONDUCTOR RECTIFIER SYSTEM PER 46 CFR 111.33-11.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Engineering
Issued 10 December 1993
Resolved
INSTALL ADEQUATE LIGHTING FOR THE AMPERAGE GAUGES AND SHAFT TACH INDICATOR THAT THEY MAY READ DURING PERIOD OF DARKNESS AND REDUCED VISIBILITY TO THE SATISFACTION OF THE COGNIZANT OCMI._x001C_
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Fire Fighting
Issued 10 December 1993
Resolved
RESUBMIT FOR APPROVAL SERVICE MARINE INDUSTRIES, INC. DWG. 167/06280A WITH_x001C_REVISIONS TO SATISFY MSC COMMENT LETTER M-30746 DATED 06 DECEMBER 1993,_x001C_ PARAGRAPH 2.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993