Records in 1994. Most recent: inspection, 31 August 1994.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Construction/Loadline
Issued 31 August 1994
Resolved
REPAIR/REPLACE GASKETS ON WEATHER TIGHT DOORS ON MAIN DECK TO THE_x001C_ SATISFACTION OF CLASS SOCIETY AND SHOW REPAIRS TO LOCAL U.S.C.G. OMCI DURING NEXT U.S. VOYAGE.
Condition: Unknown
Due 1 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 31 August 1994
Resolved
PLACE ON BOARD CHART 11324 OR FOREIGN EQUIVALENT PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 September 1994
Resolved 6 September 1994
Construction/Loadline
Issued 31 August 1994
Resolved
REPAIR/REPLACE GASKETS ON WEATHER TIGHT DOORS ON 01 LEVEL OF SUPERSTRUCTURETO THE SATISFACTION OF CLASS SOCETY AND SHOW REPAIRS TO LOCAL U.S.C.G. DURING NEXT U.S. VOYAGE.
Condition: Unknown
Due 1 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 31 August 1994
Resolved
REPLACE LEAKING 2.5 INCH FIREHOSE LOCATED AGAINST FORWARD BULKHEAD JUST BEFORE THE BOW.
Condition: Unknown
Due 1 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 31 August 1994
Resolved
REPAIR LEAKING FIRE HYDRANT LOCATED JUST AFT OF THE WHEELHOUSE/NAV. BRIDGE
Condition: Unknown
Due 1 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 31 August 1994
Resolved
PLACE LIGHT COVERS OVER ALL LIGHT FIXTURES. FIXTURES NOTED IN GALLEY, HOSPITAL, CLINIC, PASSEGEWAY, & ENGINEROOM.
Condition: Unknown
Due 1 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 31 August 1994
Resolved
REPAIR BULKHEAD IN PASSEGEWAY LEADING TO COOLER/FREEZER TO THE SATISFACTIONOF CLASS SOCIETY & SUBMIT REPORT TO LOCAL U.S.C.G. [name withheld] U.S. VOYAGE.
Condition: Unknown
Due 1 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 31 August 1994
Resolved
REPAIR COLLASPING OVERHEAD IN PASSEGEWAY LOCATED IN LOWER LEVEL BY BERTHINGAND STORAGE AREAS IN SUPERSTRUCTURE TO THE SATISFACTION OF CLASS SOIETY, AND SUBMIT REPORT TO LOCAL U.S.C.G. [name withheld] U.S. VOYAGE.
Condition: Unknown
Due 1 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 31 August 1994
Resolved
PLACE HANDLE ON INSIDE DOOR ENTRANCE TO FREEZER. SOMEONE MUST BE OUTSIDE OF DOOR WHENEVER SOMEONE GOES INTO FREEZER UNTIL DOOR IS REPAIRED.
Condition: Unknown
Due 1 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 31 August 1994
Resolved
REPAIR/REPLACE NAVIGATION DAY SHAPES.
Condition: Unknown
Due 1 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 31 August 1994
Resolved
TEMPORARILY REPAIR FACE SHIELD ON ENGINE ROOM AIR BREATHING APPARATUS PRIORTO DEPARTURE AND REPLACE FACE SHIELD BY 01DEC94.
Condition: Unknown
Due 1 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 31 August 1994
Resolved
PLACE ON BOARD UPDATED OIL TRANSFER PROCEDURES, PRIOR TO BUNKERING IN U.S. WATERS.
Condition: Unknown
Due 1 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past