MAURY USCG vessel records Sign in
← All vessels

SALONTA

SALONTA is a 1979 freight ship. The Coast Guard has recorded 3 inspections in 1997, along with 25 deficiencies and 1 operational control.

Records in 1997. Most recent: inspection, 5 September 1997.

Built
1979
Last inspected
5 September 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7906198 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
385203
Flag
ROMANIA
—
Maury page id
psix-385203

Inspections, by type

…with no type recorded3
Years with a record 1 calendar year (1997)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3516 - Regulatory (Subpart C or D), Gross Ton
1822 - Regulatory (Subpart C or D), Net Ton
4693 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

5 September 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 724483
18 August 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 406826
12 August 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 406691

Deficiency record · 25

Lifesaving
Issued 18 August 1997 Resolved
PROVIDE ON BOARD TWO 2-WAY VHF RADIO TELEPHONES FOR USE IN EACH LIFEBOAT._x001C_ PER SOLAS 74 (AMENDED)III/6.2.1
Condition: Unknown
Due 22 August 1997
Resolved 25 August 1997
Engineering
Issued 18 August 1997 Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR, ALARM, INDICATOR AND AUTOMATIC VALVE._x001C_ PER MARPOL 73/78 ANNEX I/16(7)
Condition: Unknown
Due 22 August 1997
Resolved 25 August 1997
Documentation
Issued 12 August 1997 Resolved
Required publications for U.S. waters not on board (Coast Pilot [name withheld], Tide Tables). Provide the proper publications onboard prior to departure from Houston, TX. NLT 13AUG97 IAW 33CFR164.33.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 12 August 1997 Resolved
Replace indicator lights on panelboard for steering pumps 1 & 2. Replace NLT 26Aug97 IAW SOLAS 60 II/30.
Condition: Unknown
Due 26 August 1997
Resolved 8 November 2006
Fire Fighting
Issued 12 August 1997 Resolved
Emergency fire pump not generating adequate pressure. Emergency fire pump to provide adequate pressure prior to departure from Houston, TX IAW SOLAS 60 Reg. II/56(c).
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 August 1997 Resolved
Bilge pump missing protective guards by moving parts. Provide protective guards for bilge pump NLT 26Aug97 IAW SOLAS 74 (amended) II-1/26.1.
Condition: Unknown
Due 26 August 1997
Resolved 8 November 2006
Construction/Loadline › Hull › Bottom Plating
Issued 12 August 1997 Resolved
Excessive leaking in overboard ballast discharge valve. Repair leak in valve NLT 26AUG97 IAW ILCC66 I/15.
Condition: Unknown
Due 26 August 1997
Resolved 8 November 2006
Navigation
Issued 12 August 1997 Resolved
Gyro repeater in aft steering space not aligned with bridge. Repair gyro_x001C_ repeater NLT 26 Aug 97.
Condition: Unknown
Due 14 August 1997
Resolved 14 August 1997
Construction/Loadline › Hull › Bottom Plating
Issued 12 August 1997 Resolved
Sounding tube for water tank on portside fantail has deteriorated (moderatesize hole). Repair sounding tube NLT 12Sep97 IAW ILCC66 Annex I/18.
Condition: Unknown
Due 12 September 1997
Resolved 8 November 2006
Construction/Loadline › Hull › Bottom Plating
Issued 12 August 1997 Resolved
Weatherdeck fire station covers, missing latches. Repair/Replace latches for fire station covers NLT 26Aug97 IAW SOLAS 74 (amended) II-2/21.
Condition: Unknown
Due 26 August 1997
Resolved 8 November 2006
Lifesaving › Buoyant Apparatus › Approval
Issued 12 August 1997 Resolved
Lifebuoy deteriorated on foc'sle. Replace lifebuoy NLT 12Sep97 IAW IAW SOLAS 60 Reg. III/21.
Condition: Unknown
Due 12 September 1997
Resolved 8 November 2006
Unknown
Issued 12 August 1997 Resolved
Hospital space has excessive loose wires and no water pressure. Correct_x001C_ loose wires and water pressure NLT 15Aug97 IAW ILO 147.
Condition: Unknown
Due 8 September 1997
Resolved 8 September 1997
Navigation
Issued 12 August 1997 Resolved
Navigational chart #3185 for Houston transit not corrected within 4 months.Correct chart #3185 up-to-date prior to departure from Houston, TX IAW SOLAS 74 (amended) Reg. V/20._x001C_
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Unknown
Issued 12 August 1997 Resolved
Ship's logbook missing entries for arrival tests prior to entering port of Houston. Prior to next U.S. port, conduct proper tests with appropriate logbook entries IAW 33CFR164.25._x001C_ _x001C_
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Lifesaving
Issued 12 August 1997 Resolved
Fire and boat drills not logged (monthly). Prior to next U.S. port, conduct fire and drill with appropriate logbook entries IAW SOLAS 74 (amended) Reg. III/18.5._x001C_
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Construction/Loadline
Issued 12 August 1997 Resolved
Oily water separator indicator panel not giving accurate PPM readings._x001C_ Correct OWS indicator panel NLT 15Aug97 IAW Marpol I/16.
Condition: Unknown
Due 8 September 1997
Resolved 8 September 1997
Navigation
Issued 12 August 1997 Resolved
Emergency steering drills not logged (quarterly). Prior to next U.S. port,conduct steering drills with appropriate logbook entries IAW SOLAS 74 (amended) Reg. V/19.2 (d).
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Lifesaving
Issued 12 August 1997 Resolved
Missing training manual for lifesaving. Provide training manual onboard, NLT 19AUG97, IAW SOLAS 74 (amended) Reg III/18 & 51.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Lifesaving
Issued 12 August 1997 Resolved
Missing maintenance manual (of lifesaving appliance) entries for last 5 months. Prior to next U.S. port, conduct inspection of lifesaving appliances with appropriate entries made IAW SOLAS 74 (amended) Reg III/19.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Engineering
Issued 12 August 1997 Resolved
Oil transfer procedures not present. Provide satisfactory oil transfer procedures onboard prior to commencing bunkering operations IAW 33CFR155.720.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Engineering
Issued 12 August 1997 Resolved
Person-In-Charge designation for oil transfer. Document on transfer procedures, designated person-in-charge prior to bunkering operations IAW_x001C_ 33CFR155.700.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Fire Fighting
Issued 12 August 1997 Resolved
Emergency fire pump generates excessive smoke while operating at full capacity. Repair fire pump NLT 19Aug97 IAW SOLAS 74 (amended) II-2/21._x001C_
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Unknown
Issued 12 August 1997 Resolved
Missing placard that states Discharge of Oil Prohibited in machinery space.Correct prior to next U.S. port NLT 15Aug97 IAW 33CFR155.450. _x001C_
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Electrical
Issued 12 August 1997 Resolved
Main control board in engine control room missing backpanels. Correct _x001C_ NLT 15Aug97 IAW SOLAS 60 Reg. II/27.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Electrical
Issued 12 August 1997 Resolved
Excessive lights in passageway of house and in CO2 room not operable. Correct lighting deficiency NLT 19Aug97 IAW SOLAS 74 (amended) II-1/41.2.1.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.