Records in 1996. Most recent: inspection, 6 November 1996.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 12 September 1996
Resolved
Vessel's #2 and #3 generators could not be tested. Solas 60 CH I Reg 10
Condition: Unknown
Due 25 September 1996
Resolved 26 September 1996
Electrical
Issued 12 September 1996
Resolved
Vessel's #1 Generator exhaust piping leaking. Solas 60 CH I Reg 10
Condition: Unknown
Due 25 September 1996
Resolved 26 September 1996
Electrical
Issued 12 September 1996
Resolved
Vessel to ensure permanent repairs are made to electrical equipment throughout vessel to prevent shock hazards. (After SOLAS intervention, vessel ensured temporary repairs were made.) Solas 60 CH II Reg 27.
Condition: Unknown
Due 27 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 12 September 1996
Resolved
Vessel's weathertight doors and port lights do not properly seal. New gaskets and missing dogs to be installed.
Condition: Unknown
Due 25 September 1996
Resolved 26 September 1996
Lifesaving
Issued 12 September 1996
Resolved
Excessive oil in engineroom bilges. Solas 60 CH I REG 10.
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Fire Fighting
Issued 12 September 1996
Resolved
Thirteen spanner wrenches missing throughout vessel. _x001C_ Solas 60 CH II Reg 56(f)
Condition: Unknown
Due 20 September 1996
Resolved 26 September 1996
Navigation
Issued 12 September 1996
Resolved
Rudder angle indicator for bridge does not coincide with reading at steering gear. (10 degrees off) IAW Solas 60 CH II Reg 29.
Condition: Unknown
Due 20 September 1996
Resolved 26 September 1996
Navigation
Issued 12 September 1996
Resolved
Echo depth sounder inoperable iaw 33 CFR 164.11(r).
Condition: Unknown
Due 20 September 1996
Resolved 26 September 1996
Lifesaving
Issued 12 September 1996
Resolved
Repair oil leaks and clean entire engineroom. Excessive oil throughout engineroom creates fire hazard. SOLAS 60 CH I REG 10
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996
Navigation
Issued 12 September 1996
Resolved
Various radio apparatuses are not working properly iaw ship's station liscense. Main transmitter, VHF Radio, radio beacon antenna broken and EKVradio receiver signal to noise ratio excessive. Solas 60 CH IV Reg 9
Condition: Unknown
Due 25 September 1996
Resolved 26 September 1996
Electrical
Issued 12 September 1996
Resolved
Vessel missing light covers throughout vessel. ILO 147
Condition: Unknown
Due 27 September 1996
Resolved 27 September 1996