Records from 1993 to 2026. Most recent: inspection, 9 July 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 60
9 July 2026
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8345146
12 May 2025
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8133305
4 November 2024
Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8029128
11 July 2024
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7861539
4 May 2023
COI Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7665752
26 October 2022
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7584186
11 October 2022
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7570315
8 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7509719
27 September 2021
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7321470
29 July 2021
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7271852
30 October 2020
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7075999
6 August 2020
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7025257
13 September 2019
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6810804
6 August 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6762984
17 August 2018
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6515249
4 May 2018
COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6405768
12 July 2017
Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6206245
28 April 2017
Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6134360
25 May 2016
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5886334
20 May 2014
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4952208
7 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4203622
21 July 2009
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3547444
17 June 2008
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3242522
26 July 2007
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3010585
30 March 2007
Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2905966
17 May 2006
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2651287
25 February 2005
Hull Examination · COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2354832
9 December 2004
Drydock Extension
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2256421
4 June 2004
Periodic Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2088337
23 April 2003
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1777809
8 January 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1727598
9 December 2002
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1716383
13 March 2002
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1493283
30 October 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1649994
8 March 2001
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1391486
9 January 2001
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1426512
12 April 2000
COI Inspection · Plan Review "T" Boat
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1464276
2 September 1999
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1131932
22 June 1999
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1191096
19 May 1999
Deficiency Check · Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1469268
12 January 1999
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1384003
9 July 1998
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 794030
13 May 1998
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 791413
12 May 1997
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1102759
16 April 1997
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1424382
28 January 1997
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1433150
14 June 1996
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1089987
24 April 1996
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1363587
15 May 1995
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1427060
24 April 1995
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1400165
7 July 1994
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1172037
23 June 1994
Damage Survey
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1429904
22 June 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 121894
8 June 1994
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1015571
11 May 1994
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1419256
9 February 1994
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1163753
24 January 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 851635
28 May 1993
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1362782
14 May 1993
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 847858
10 May 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1141803
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2025
Resolved
§ 184.710 First-aid kits.
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 25 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2024
Resolved
Make proper repairs to leaking Port Rudder Post. Rudder post was leaking excesive water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 18 July 2024
Resolution: tightened packing / seal on rudder post.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2024
Resolved
Make proper repairs to port and starboard shaft packing to repair leaking water into bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 18 July 2024
Resolution: tightened packing / seals on shafts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 July 2024
Resolved
Provide 12 additional adult lifejackets to meet minimum of Total Persons allowed on Vessel - 117. Vessel was found to have 22 Adult lifejackets that were unsatisfactory for flotation due to age.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 18 July 2024
Resolution: new lifejackets provided / stenciled and onboard.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 11 July 2024
Resolved
Vessel needs to provide Valid list of current crew showing proof they are enrolled in Drug Testing Program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 18 July 2024
Resolution: Employees are members of state drug test program - documention of enrolled employees added to vessel.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 26 October 2022
Resolved
A vessel with more than one passenger deck must have the public address system operable from the operating station. First deck public address system not operable. The vessel will be restricted from carrying passengers after November 30, 2022 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2022
Resolved 5 December 2022
Resolution: MI verified completion of repairs.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 26 October 2022
Resolved
The master of a vessel, except a vessel listed in §185.502(a) of this part, shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel’s normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Passenger count not made available to the Coast Guard upon request. The vessel will be restricted from carrying passengers after November 30, 2022 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2022
Resolved 5 December 2022
Resolution: MI verified completion of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 October 2022
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space bilge. Visual alarm not working for the machinery space. The vessel will be restricted from carrying passengers after November 30, 2022 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2022
Resolved 5 December 2022
Resolution: MI verified completion of repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 October 2022
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Ring life buoy’s are missing Type II retroreflective material. The vessel will be restricted from carrying passengers after November 30, 2022 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2022
Resolution: MI verified completion of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 October 2022
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a).”S” vessels carrying more than 49 passengers, 65 feet or less shall carry 1 portable hand pump with minimum required capacity of 5 gallons per minute. Portable hand pump is not working properly. The vessel will be restricted from carrying passengers after November 30, 2022 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2022
Resolved 5 December 2022
Resolution: MI verified completion of repairs.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 26 October 2022
Resolved
Provide basic first aid and CPR training and certification in accordance with the guidelines for deckhand training found in NVIC 1-91. At least 50% members of the crew must be current in their certifications. The vessel will be restricted from carrying passengers after November 30, 2022 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Condition: Invalid
Due 30 November 2022
Resolved 5 December 2022
Resolution: MI verified completion of repairs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 August 2022
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date.Vessel failed to undergo an annual inspection by 8AUG2022 which is past the 3 month anniversary date of 8MAY2018 as required by 46CFR176.500(b)(1). Vessel must rectify deficiency prior to departure to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2022
Resolved 2 November 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 July 2021
Resolved
Mast stern light bezel is hazed reducing visibility.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2021
Resolved 27 September 2021
Resolution: Recieved report of repairs from [name withheld].
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2021
Resolved
Stern lifebuoy float light attachment line is deteriorated.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2021
Resolved 27 September 2021
Resolution: Received report of repairs from vessel master [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 July 2021
Resolved
FWD second deck lifebuoy has water intrusion and needs to be renewed.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2021
Resolved 27 September 2021
Resolution: Received report of repairs from vessel master [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 29 July 2021
Resolved
Port side removable handrail for boarding has two cracks reducing the load carrying strength.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2021
Resolved 27 September 2021
Resolution: Received report of repairs from vessel master [name withheld]
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 6 August 2019
Resolved
Provide first aid kit, current one is expired and does not meet
46CFR184.710/160.041. The vessel will be restricted from carrying passengers
after September 6, 2019 if the deficiency has not been corrected to the
satisfaction of an attending Coast Guard Marine Inspector
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2019
Resolved 13 September 2019
Resolution: A new first aid kit was provided onboard with expiration date of January 2021.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 August 2019
Resolved
Provide a Communications Act, Safety Radiotelephony Certificate in
accordance with 47 CFR 80.411 to the satisfaction of an attending Coast
Guard Marine Inspector. The vessel will be restricted from carrying
passengers after September 6, 2019 if the deficiency has not been corrected
to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2019
Resolved 13 September 2019
Resolution: A new Communications Act Safety Radio Certificate was issued to the vessel but exceeded the five year statutory expiration. The radio equipment was surveyed on September 6, 2019 and the Certificate will expire on March 10, 2028. Spoke with the FCC surve
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 August 2019
Resolved
Provide proof of pre-employment drug testing and enrollment in the
Company's random drug testing pool in accordance with 46 CFR 16.210. Any
crew are not authorized to fill any safety sensitive position on the vessel
until the necessary proof of pre-employment and enrollment in the random
program are received and reviewed by this office.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2019
Resolved 4 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2019
Resolved
Vessels Fuel shutoff valves are not marked and does not meet the minimum
standard of Remote fuel shutoff stations must be marked in clearly legible
letters at least 25 millimeters (1 inch) high indicating purpose of the
valve and direction of operation. The vessel will be restricted from
carrying passengers after September 6, 2019 if the deficiency has not been
corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2019
Resolved 13 September 2019
Resolution: Marking was made on the back of the seat where the fuel shut offs are located on the deck.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 August 2019
Resolved
Vessels public address system in the main deck space is not working and
needs to be replaced. The vessel will be restricted from carrying passengers
after September 6, 2019 if the deficiency has not been corrected to the
satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2019
Resolved 13 September 2019
Resolution: Tested the Public Address System and found it satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 August 2019
Resolved
Vessel second deck loud hailer is utilizing twist on wire nuts were not being correctly used per 46CFR183.340(i) and pressure type connectors that did not meet UL 486(A) (IE. Not heat shrink connections) per 46CFR183.340(b). The vessel will be restricted from carrying passengers
after September 6, 2019 if the deficiency has not been corrected to the
satisfaction of an attending Coast Guard Marine Inspector
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2019
Resolved 13 September 2019
Resolution: Compression type connections were made and properly sealed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 August 2019
Resolved
Vessel has dead end wiring second deck aft light does not meet minimum standard of protecting crew, other and the vessel from electrical hazards as required by 46CFR183.200(b). The vessel will be restricted from carrying passengers after September 6, 2019 if the deficiency has not been corrected to the
satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2019
Resolved 13 September 2019
Resolution: Unable to locate the dead end wiring as per the original written requirement. No dead wiring was observed on the second deck and the requirement is cleared.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 May 2018
Resolved
Replace retro or remove from service 27 adult life jackets and 14 children life jackets identified by the CG Vessel still has enough life jackets as indicated on the COI without above lifejacket.
Action required: 10 - Deficiency Rectified
Due 25 May 2018
Resolved 25 May 2018
Resolution: Vessel removed from service
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 8 May 2018
Resolved
Passenger count was not maintained ashore. Show proof that it is maintained within 7 days.
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 15 May 2018
Resolution: Picture, Sat
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 8 May 2018
Resolved
Electrical distribution panel not marked in pilot house panel circuits to identify service. Vessel has 7 days to complete
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 15 May 2018
Resolution: Picture, SAT
Engineering › Bilge Water Management System › Piping
Issued 8 May 2018
Resolved
Install hose clamp on electrical submersible pump in engine room and bilge piping system in lazzerette. Vessel has 7 days to complete.
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 15 May 2018
Resolution: Picture, SAT
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2018
Resolved
Repair dead end wiring in forward compartment. Vessel has 7 days to complete.
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 15 May 2018
Resolution: Picture, SAT
Construction/Loadline › Penetrations › Valve Flange
Issued 8 May 2018
Resolved
Cap off unused penetration in forward compartment. Vessel has 7 days to complete.
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 15 May 2018
Resolution: Picture, SAT
Electrical › Electrical Distribution System (service) › Cable
Issued 8 May 2018
Resolved
Engine room starboard side grounding wire is broke and needs to be replaced. Vessel has 7 days to complete.
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 15 May 2018
Resolution: Picture, Sat
Communications › Public Address System › Loudspeaker
Issued 8 May 2018
Resolved
Vessels public address system in the main deck space is not working and needs to be replaced in 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 5 June 2018
Lifesaving › Lifebuoys › Stowage
Issued 18 July 2017
Resolved
Properly arrange one life ring bouy with 60 feet of life line and attach a floating water light with a lanyard that is secured around the body of the ring buoy to the satisfation of an attending Coast Guard marine inspector in accordance with 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 24 July 2017
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 July 2017
Resolved
Provide a current and corrected Coast Guard Light List, Volume III or an abstract of the same for the area of operation in accordance with 46 CFR 184.420(a)(3)
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 24 July 2017
Resolution: Picture Verification
Engineering › Fuel Oil Service System › Valve
Issued 18 July 2017
Resolved
Demonstrate proper operation of the emergency fuel shut off in way of the starboard fuel tank to the satisfaction of an attending Coast Guard marine inspector in accordance with 46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 24 July 2017
Construction/Loadline › Hull › Side Shell
Issued 28 April 2017
Resolved
Submit repair proposal for the dull due to numerous blisters indentified on the port and starboard sides. Prior to hull repair to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 May 2017
Resolution: Rcvd repair proposal.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 28 April 2017
Resolved
Extensive porocity identified along the port and starboard side bearing house. porocity is greater than 1/4 in.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 July 2017
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 28 April 2017
Resolved
Replace port and starboard rubber bearings. prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 July 2017
Engineering › Steering Gear System › Bracket/Clamp
Issued 28 April 2017
Resolved
Replace port and starboard shaft boot clamps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 July 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 July 2016
Resolved
Replace the serviceable floating water light in way of the Life Ring Buoy on the second deck aft. The Floating water light must be approved under 46 CFR 161.010.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 8 August 2016
Resolution: Onsite verification, Satisfactory
Electrical › Electric Generation Source (service) › Panelboard
Issued 7 July 2016
Resolved
Properly label the breaker panel located in the engine room on the forward bulkhead for the service for each breaker.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 8 August 2016
Resolution: Onsite verification, Satisfactory
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 July 2016
Resolved
Properly affix retro-reflective tape on the body of the Life Ring Buoy Buoy located on the second deck aft in accordance with 46 CFR 185.604(i). 46 CFR 180.70 and 46 CFR 185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 8 August 2016
Resolution: Onsite verification, Satisfactory
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 7 July 2016
Resolved
Generator exhaust pipe between the cooling water and engine manifold is showing signs of scaling. Evaluate the condition of the pipe and submit results to the OCMI to include repair proposal if repairs are to be completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 8 August 2016
Resolution: Onsite verification, Satisfactory
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 May 2016
Resolved
Properly replace expired medication on the First Aid kit and ensure contents meet meet the requirements found in Table 46CFR 160.041-4(B)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 8 August 2016
Resolution: Onsite verification, Satisfactory
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 25 May 2016
Resolved
Properly repair lagging on the generator exhaust pipe to provide insulation and protection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 8 August 2016
Resolution: Onsite verification, Satisfactory
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 May 2016
Resolved
Ensure drills are conducted every three (03) months or prior to the vessel carrying passengers whichever occurs first & document the information. 46 CFR 185.420(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 8 August 2016
Resolution: Onsite verification, Satisfactory
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 May 2014
Resolved
Replace line on the lifebuoys
Action required: 705 - Other - as specified
Resolved 27 May 2014
Resolution: Operator replaced lines on the lifebuoys.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 21 July 2009
Resolved
One bottle had a greater than 10% loss of medium.
Due 31 July 2009
Resolved 28 July 2009
Resolution: Bottle removed hysdrostatically tested and refilled.
Documentation › Certificates/Documents › FCC SSL
Issued 21 July 2009
Resolved
FCC SSL missing on board. SSL is current Provide original to be posted on vessel.
Action required: 705 - Other - as specified
Due 21 May 2010
Resolved 29 April 2011
Electrical › Electric Supply System (service) › Battery Charger
Issued 17 June 2008
Resolved
The pig tail that plugs the battery charger into the outlet had a spliced cord that needs to be replaced.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 21 July 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 June 2008
Resolved
Several items in the first-aid kit were past their expiration dates.
Action required: 705 - Other - as specified
Due 17 July 2008
Resolved 21 July 2009
Fire Fighting › Fire Pumps › Capacity
Issued 26 July 2007
Resolved
Fire pump did not have a capacity rating marked on it, required to provide manufacturer infomation attesting to rated capacity of pump.
Due 26 August 2007
Resolved 2 August 2007
Resolution: Received fax of pump specs. Foncon w/ operator confirmed renewal in kind.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 July 2007
Resolved
Audible alarm for lazarette bilge pump did not work, visual alarm did work.
Due 10 August 2007
Resolved 10 August 2007
Resolution: Audible alarm replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 May 2006
Resolved
Three fixed CO2 bottles have not been hydro tested since 1998.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 30 June 2006
Resolution: All 3 bottles renewed. Originals failed Hydrostatic test.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 May 2006
Resolved
Vessel has rub rails bolts to hull around waterline belt. Rub rails have been renewed/moved and old bolt holes are open to the sea.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 30 June 2006
Resolution: All holes plugged with epoxy and micro balloons.
Communications › Internal Communications System › Portable Radios
Issued 11 May 2005
Resolved
Renew/Repair the aft upper deck PA speaker.
Condition: Improper/Lack of Maintenance
Due 30 May 2005
Resolved 11 May 2005
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 11 May 2005
Resolved
Provide an effective means for retrieving an unconscious person from the water.
Condition: Unknown
Due 30 October 2005
Resolved 30 October 2005
Resolution: Corrected to satisfaction of attending Marine Inspector.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 February 2005
Resolved
Reinstall bilge lazarette bilge alarm float switch.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2005
Resolved 11 May 2005
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 23 April 2003
Resolved
PMDE exhaust pipe was weeping as a result of a previously failed r/w pump impeller, pipe was re-glassed.
Condition: Damaged By Earlier Event
Due 23 April 2003
Resolved 23 April 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 April 2003
Resolved
S/SDG would not shutdown when CO2 system was energized, found a broken wire connection, repaired same.
Condition: Unknown
Due 23 April 2003
Resolved 23 April 2003
Engineering
Issued 19 May 1999
Resolved
INSTALL MACHINERY GUARDS ON MAIN DIESEL ENGINES.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Documentation
Issued 19 May 1999
Resolved
THIS IS AN ADMINISTRATIVE REQUIREMENT TO GEORGIA DNR (HQ), SOCIAL CIRCLE, GA: PROVIDE ALL APPLICABLE DRUG TESTING PROGRAM DETAILS FOR COAST GUARD REVIEW PER 46CFR16.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Lifesaving
Issued 19 May 1999
Resolved
ATTACH RETROREFLECTIVE TAPE TO 30 IDENTIFIED LIFEJACKETS._x001C_
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Fire Fighting
Issued 19 May 1999
Resolved
PROVIDE PLANS FOR THE INSTALLED FIXED CO2 SYSTEM. PLANS MUST INCLUDE VOLUMETRIC CALCULATIONS IN A PROFILE VIEW FORMAT, LIST OF MATERIALS, PIPINGARRANGEMENT INCLUDING MATERIAL, SIZE AND SCHEDULE AND SYSTEM DESIGN CALCULATIONS AND FORMULAS USED.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Lifesaving
Issued 19 May 1999
Resolved
PROVIDE THREE (3) ORANGE AND THREE (3) RED DISTRESS SIGNALS.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Fire Fighting
Issued 19 May 1999
Resolved
MOUNT PORTABLE (BI) FIRE EXTINGUISHER IN WAY OF THE PILOT HOUSE.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Construction/Loadline
Issued 12 January 1999
Resolved
Repair or replace over board valve for fire main. Prior to operating.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Construction/Loadline
Issued 12 January 1999
Resolved
Make area below stb bit amidship open for inspection to evaluate installation and repair of bit mount. Bit was torn from boat during severestorm.
Condition: Unknown
Due 12 January 1999
Resolved 12 January 1999
Lifesaving
Issued 13 May 1998
Resolved
Provide upper deck markings for maximum passengers allowed as per 46 CFR 185.602.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Construction/Loadline
Issued 13 May 1998
Resolved
Replace bracket for lazerete bilge line support.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Lifesaving
Issued 13 May 1998
Resolved
Provide proper stowage box for distress signals as per 46 CFR 185.614.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Lifesaving
Issued 13 May 1998
Resolved
Provide first aid kit as required by 46 CFR 185.710.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Lifesaving
Issued 13 May 1998
Resolved
Provide emergency drills and log same as required by 46 CFR 185.520.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Lifesaving
Issued 16 April 1997
Resolved
Provide emergency broadcast placard.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Construction/Loadline
Issued 16 April 1997
Resolved
Provide door handle on main deck door aft.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Construction/Loadline
Issued 28 January 1997
Resolved
MAKE PERMANANT REPAIRS TO FOREPEAK MAIN DECK BEAM (FR 3) LOCATED APPROXIMATELY 3 FT FROM THE BOW.
Condition: Unknown
Due 28 January 1997
Resolved 28 January 1997
Unknown
Issued 24 April 1996
Resolved
Repair or replace leaking windows on Port and Stbd maindeck. Evidence of leakage was found in lifejacket storage areas located under windows.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Fire Fighting
Issued 24 April 1996
Resolved
Provide test and certification on the Fixed Firefighting System in the presence of a USCG Marine Inspector.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Electrical
Issued 24 April 1996
Resolved
Repair or replace all deck lights on main deck exterior. All overhead lights on main deck were found severely corroded, cracked or missing parts.
Condition: Unknown
Due 24 April 1996
Resolved 24 April 1996
Engineering
Issued 23 June 1994
Resolved
Made repairs to port main engien starter and electrical system. Replace daamaged fuel oil line stbd side and replace all burnt electrical wiring asneeded. Provide test of main engine after overhauled.
Condition: Unknown
Due 23 July 1994
Resolved 7 July 1994
Lifesaving
Issued 11 May 1994
Resolved
Provide 3 additional orange hand held flares. Vessels runs are limited to 30 minutes until provided.
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Fire Fighting
Issued 11 May 1994
Resolved
Service fixed CO2 system for engine room and have ready for tests in present of Coast Guard Marine Inspector
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Lifesaving
Issued 11 May 1994
Resolved
Provide 10 additional adult life jackets, Total Persons allowed limited to 143 until provided.
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Lifesaving
Issued 11 May 1994
Resolved
Provide means to prevent passengers from going into forward below deck area. (chain and sign)
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Fire Fighting
Issued 28 May 1993
Resolved
PROVIDE OPERATING INSTRUCTIONS FOR FIXED CO2 SYSTEM FOR ENGINE ROOM AS REQUIRED BY 46 CFR 181.20-15.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Engineering
Issued 28 May 1993
Resolved
PROVIDE REMOTE SHUTDOWNS FOR FUEL SHUTOFF FOR FUEL TANKS OUTSIDE THE ENGINEROOM AS REQUIRED BY 46 CFR 182.20-40.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Fire Fighting
Issued 14 May 1993
Resolved
PROVIDE APPROVED PLANS FOR THE INSTALLATION OF CO2 FIRE SUPPRESSION SYSTEM.CONDUCT INSTALLATION TESTING IN ACCORDANCE WITH 46 CFR 181.20 AND NVIC 6-72TO DETERMINE FINAL ACCEPTANCE OF SYSTEM. TWO B-II FIRE EXTINGUISHERS ARE REQUIRED FOR ENGINE ROOM UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 14 May 1993
Resolved 14 May 1993