Inspection history · 23
24 October 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8258454
26 March 2025
Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8100176
9 October 2024
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8016513
19 December 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7840471
14 December 2022
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7609137
1 December 2022
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7602657
13 October 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7576801
14 October 2021
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7332298
14 October 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7368023
15 December 2020
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7111891
16 November 2020
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7094949
30 December 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6880814
1 November 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6847282
4 October 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6828371
11 January 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6609274
26 November 2018
Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6593924
7 November 2018
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6577019
26 January 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6344495
19 January 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6340683
10 January 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6336670
2 December 2016
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6051715
31 October 2016
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6051698
26 September 2016
Drydock Extension
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6009852
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 October 2025
Resolved
Each portable fire extinguisher on a vessel must be of an approved type.... Vessel is required per COI (01) 10BC and (01) 40BC extinguisher. Vessel must replace the missing required (01) 40BC extinguisher. Vessel POC replaced (01) 40BC extinguisher during the inspection. 46 CFR 181.500(a)
Action required: 10 - Deficiency Rectified
Due 29 October 2025
Resolved 29 October 2025
Resolution: Vessel POC replaced (01) 40BC extinguisher during the inspection
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2024
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2024
Resolved 14 October 2024
Resolution: New FCC station certificate received.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 19 December 2023
Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Vessel's EPIRB battery was past its expiration date. Replace battery to satisfaction of attending Coast Guard Marine Inspector. Vessel restricted to within three mile of shore.
46 CFR 185.728
Action required: 705 - Other - as specified
Resolved 12 January 2024
Resolution: New EPIRB provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 December 2023
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temp, and lube oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Gauge not operational. Make all gauges operational.
46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2024
Resolved 6 February 2024
Resolution: Gauges operational.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 October 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Aluminum frame cracked on starboard side first stringer in mid ship void. Multiple areas of pitting over 25% threshold to hull in mid ship void, storage locker starboard side, and storage locker port side. Submit repair proposal Coast Guard office where you intend to conduct drydock and make appropriate permanent repairs to hull. Submit proposal and make repairs at 30 Nov 2022 drydock prior to receiving credit drydock.
46 CFR 177.100
Action required: 705 - Other - as specified
Resolved 7 March 2023
Resolution: Satisfactory repairs made to hull. See inspection #7609137.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 October 2021
Resolved
The EPIRB must be tested and logged monthly. EPIRB test is not being logged monthly. Provide monthly EPIRB test log.
46 CFR 185.728
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 10 November 2021
Resolution: Log book entry provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 October 2021
Resolved
The construction of a vessel must allow the safe operation of the vessel. Cracks port and starboard side on Bimini structure at bulwarks connection at second post from bow. Submit repair proposal and make repairs to cracking Bimini structure.
46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 10 November 2021
Resolution: Weld repairs made to bimini.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 October 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 10 November 2021
Resolution: EAP training conducted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 October 2021
Resolved
Employers Policy regarding drug and alcohol use in the workplace must be displayed. There was not a copy of the company drug and alcohol policy on the vessel. Provide a copy of company drug and alcohol policy on vessel.
46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 10 November 2021
Resolution: Policy provided on vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 November 2020
Resolved
The space containing propulsion machinery must be equipped with a fixed gas fire extinguishing system. When the vessel's fixed gas fire extinguishing system is in override the engines will not energize. Repair or replace the override portion of the fixed gas fire extinguishing system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2020
Resolution: Fire Boy override operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2019
Resolved
PFD interior material is beginning to deteriorate at edges due to heat/age. Renew PFDs in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2019
Resolved 1 November 2019
Resolution: New PFDs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 October 2019
Resolved
Life float outer coverings were damaged and in need of renewal. Renew in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 December 2019
Resolution: New lifefloats provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 October 2019
Resolved
Fireboy visual and audible alarm at the operating station were inoperable. Prove correct operation in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2019
Resolved 1 November 2019
Resolution: Fireboy audible and visual alarm satisfactory.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 October 2019
Resolved
VHF DSC radio function was not programmed. Prove operation of DSC function in accordance with 46 CFR 184.502.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2019
Resolved 7 January 2020
Resolution: DSC VHF radio programmed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 October 2019
Resolved
Record of emergency drills and monthly e-pirb test were not provided. Provide current records in accordance with 46 CFR 185.420 and 46 CFR 185.728.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2019
Resolved 30 December 2019
Resolution: Current logs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2019
Resolved
PFDs are stored in the overhead with no means of quick release. Provide means of quick release for distribution in accordance with 46 CFR 180.78(a)(3) by completion of 2020 drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 December 2019
Resolution: Lifejackets stowed in overhead with bungie chords allowing for quick release.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 November 2018
Resolved
40-B:C portable fire extinguisher was not mounted. Mount in accordance with 46CFR 181.520.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 January 2019
Resolution: Extinguisher mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 November 2018
Resolved
Ring bouy markings were unsatisfactory. Retro material was degraded. Vessel name was not clearly legible. Mark in accordance with 46CFR 185.604.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 January 2019
Resolution: Ringbuoy markings satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 November 2018
Resolved
Life float grab lines and painter lines were deteriorated. Renew in accordance with 46CFR 180.175.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 January 2019
Resolution: Life float lines renewed.
Communications › Radio Communications › EPIRB
Issued 10 January 2018
Resolved
Battery is expired. Renew in accordance with 46 CFR 180.64. Vessel limited to within 3 miles of shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 January 2018
Resolution: New e-pirb provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 January 2018
Resolved
Certificate missing. Provide in accordance with 47 CFR.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 January 2018
Resolved 26 January 2018
Resolution: Certificate renewed.