GRAND LADY

GRAND LADY is a 1993 passenger vessel (inspected). The Coast Guard has recorded 56 inspections since 1993, most recently in June 2026, along with 106 deficiencies and 1 casualty investigation in 2026.

Records from 1993 to 2026. Most recent: inspection, 13 June 2026.

Built
1993
Last inspected
13 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY9938
385380
Flag
UNITED STATES
368094770
Maury page id
psix-385380

Inspections, by type

…with no type recorded6
Years with a record 30 calendar years (1993–2026)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)72.6 ft × 20.0 ft × 5.4 ft
Registered tonnagegross 51 / net 34
ITC dimensions (L × B × D)72.6 ft × 20.0 ft × 5.4 ft
ITC tonnageNot recorded
BuilderSKIPPERLINER IND INC · LACROSSE WI, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGRAND ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
53 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK8501MMSI 368094770 · active · compulsorily equipped · granted 22 May 2019, expires 22 May 2029
WCY9938MMSI 367399930 · expired · compulsorily equipped · granted 18 March 2009, cancelled 15 June 2019
WCW6777MMSI not assigned · expired · compulsorily equipped · granted 18 June 1996, cancelled 19 August 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 56

13 June 2026 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8413701
20 May 2026 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8381890
29 May 2025 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8148223
23 April 2025 Examination of Repairs · Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8117539
21 May 2024 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7916448
17 May 2023 Administrative Inspection · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7690737
19 October 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7580415
25 May 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7420823
26 May 2021 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7158790
27 March 2020 Annual Inspection · Examination of Repairs · DAPI Audit · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6932198
11 April 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6660367
21 March 2018 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6375854
2 October 2017 Drydock Exam · Administrative Inspection · Plan Review "T" Boat · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6279522
22 March 2017 Administrative Inspection · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6109574
24 May 2016 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5885617
30 March 2016 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5843754
9 May 2012 COI Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4302189
8 December 2011 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4204446
12 May 2009 DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3472661
14 May 2008 DAPI Audit · Re-Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3206113
22 October 2007 Hull Examination
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3085464
2 May 2007 COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2920017
6 September 2006 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2770381
23 May 2006 Re-Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2657045
17 May 2005 Annual Inspection · Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2434298
20 May 2004 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2071489
16 April 2003 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1774769
15 November 2002 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1705846
31 August 2002 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1674542
22 April 2002 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1607707
21 May 2001 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1370201
1 May 2000 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1446971
3 June 1999 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1082424
28 April 1999 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1388803
8 April 1999 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 787021
11 March 1999 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 809580
27 October 1998 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 804780
6 October 1998 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 801409
4 June 1998 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1467059
14 April 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424598
21 January 1998 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1364542
17 December 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1119012
30 May 1997 Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1468412
16 April 1997 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1099159
21 February 1997 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424337
11 June 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1441076
2 May 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1430198
1 September 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1181376
3 May 1995 COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 872871
10 January 1995 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 859615
5 May 1994 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1172138
23 November 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 848393
27 September 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1160210
6 August 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1152454
4 August 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1152453
5 May 1993 Plan Review "T" Boat · Initial Certification · Hull Examination · Inclining Experiment · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1145022

Deficiency record · 106

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2025 Resolved
Battery failed to provide enough power to start starboard main engine. Replace battery as required.
Action required: 10 - Deficiency Rectified
Resolved 29 May 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 21 May 2024 Resolved
Corrosion was found on the forward engine room bulkhead. Make temporary repair to engine room bulkhead before carriage of passengers. Make permanent repairs prior to the start of the 2025 operating season.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2024
Resolved 21 May 2024
Resolution: fiberglass patch
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2023 Resolved
Vessel Owner/Operator shall conduct drills in the presence of a marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2023
Resolved 1 September 2023
Resolution: Drills were performed in the presence of a Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 October 2022 Resolved
Make permanent repairs to hull in areas found to be wasted beyond allowable percentage from guage report.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2023
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 25 May 2022 Resolved
Great Lakes radio inspection report was not available.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 26 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 26 May 2021 Resolved
A suitable, properly illuminated magnetic compass is required. The magnetic compass was not illuminate and the binnacle dome glass was cloudy. Replace or repair the magnetic compass to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 9 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 26 May 2021 Resolved
There are to be no obstructions to overboard drainage as required by 178.410. Found wasted drainage hose from deck combing drain on starboard side to overboard discharge. Make permanent repairs to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 9 June 2021
Lifesaving › Lifebuoys › Serviceable
Issued 10 May 2018 Resolved
Vessel is required to carry three 24 inch life buoys. Life buoy located on the starboard bridge wing was found to be torn an not serviceable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2018
Resolved 15 May 2018
Resolution: A new life ring was purchased. Def Cleared.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2018 Resolved
Suitable covers or guards shall be installed in way of all exposed and hazardous places such as gears and machinery. The auxiliary bilge pump that is ran off of the port engine does not currently have a guard.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2018
Resolved 15 May 2018
Resolution: A guard has been added to the aux bilge pump. Def cleared.
Engineering › Fuel Oil Service System › Hose
Issued 10 May 2018 Resolved
Fuel return line on the port engine was found leaking. Hose needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2018
Resolved 15 May 2018
Resolution: The fuel line was replaced clearing this deficiency.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 May 2017 Resolved
Found 92 adult lifejackets with severely deteriorated internal foam. Limited to 47 passengers until appropriate number is provided.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 May 2017
Resolved 12 May 2017
Resolution: Vessel owner purchased 100 new life jackets to replace the condemned jackets. Deficiency cleared.
Lifesaving › Hand Flares › Quantity
Issued 3 May 2017 Resolved
Vessel is required to have 6 red hand flares and 6 orange smoke signals. Vessel current has 4 red and 3 orange.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2017
Resolved 12 May 2017
Resolution: Vessel purchased additional flares to met the required amount.
Lifesaving › Lifebuoys › Serviceable
Issued 24 May 2016 Resolved
Replace retro on starboard aft ring buoy with type II reflective tape.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 9 June 2016
Resolution: Photo of new ring buoy received shall be verified during in-service inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 May 2016 Resolved
Provide approved water light with lanyard secured around the body of the ring buoy prior to night time operation.
Due 24 May 2016
Resolved 9 June 2016
Resolution: Received email from o/o that new light received and installed. Shall be verified during in-service inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 May 2016 Resolved
Properly secure all loose connections on battery terminal.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2016
Resolved 24 May 2016
Resolution: Corrected prior to MI's departure.
Lifesaving › Lifebuoys › Serviceable
Issued 24 May 2016 Resolved
Repair or replace starboard forward ring buoy - torn coating.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 24 May 2016
Resolution: Corrected prior to MI's departure.
Engineering › Lubricating Oil Service System › Filter
Issued 24 May 2016 Resolved
Properly secure loose oil filter on generator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2016
Resolved 24 May 2016
Resolution: Corrected prior to MI's departure.
Engineering › Bilge Water Management System › Pump
Issued 24 May 2016 Resolved
Properly secure electric bilge pumps.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 9 June 2016
Resolution: Photo received showing mounting brackets attached to framing. Shall be verified during in-service inspection.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 24 May 2016 Resolved
Provide on board or have access to the Navigation Rules Handbook.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 9 June 2016
Resolution: O/o provided emailed statement that copy of NR Handbook provided on board to be verified during in-service inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2016 Resolved
Provide required first aid kit items found expired.
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 9 June 2016
Resolution: Emailed statement from o/o provided current items provided on board. To be verified during in-service inspection.
Engineering › Freshwater System (jacketwater cooling) › Suction Strainer
Issued 24 May 2016 Resolved
Secure mount of clear bowl strainer to bracket in fuel tank space.
Due 3 June 2016
Resolved 9 June 2016
Resolution: Email statement from o/o provided that securing bolt replaced and assembly properly secured. To be verified during in-service inspection.
Operations/Management › Passenger Operations › Safety Orientation
Issued 24 May 2016 Resolved
Provide passenger count ashore. List of number of passengers to be provided
Due 24 May 2016
Resolved 24 May 2016
Resolution: Plan completed to provide to o/o and emergency contact number.
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 May 2012 Resolved
Perform underway drills to the satisfaction of Marine Inspector with emergency procedures applicable for vessel and gear available.
Action required: 705 - Other - as specified
Due 23 May 2012
Resolved 17 May 2012
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 May 2012 Resolved
Apply Type II retro-reflective tape to new life ring on upper deck.
Due 23 May 2012
Resolved 17 May 2012
Engineering › Bilge Water Management System › Manifold
Issued 9 May 2012 Resolved
Bilge piping valve numbers in engine room need to match pilot house alarm panel and schematic posted in engine room
Due 23 May 2012
Resolved 17 May 2012
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 May 2012 Resolved
Secure 2 BII fire extinguishers at bar & engine room forward bulkhead.
Due 23 May 2012
Resolved 17 May 2012
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 9 May 2012 Resolved
Clean sludge from air compressor UPV.
Due 9 May 2012
Resolved 17 May 2012
Engineering › Bilge Water Management System › Interface Detector
Issued 9 May 2012 Resolved
Mount engine room bilge pump junction box on stbd side and float switch port side engine room.
Due 23 May 2012
Resolved 17 May 2012
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 May 2012 Resolved
Stow life jackets on upper deck in manner to be readily accessible.
Due 23 May 2012
Resolved 17 May 2012
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 May 2009 Resolved
Secure and waterproof electrical outlet on FWD weatherdeck.
Condition: Improper/Lack of Maintenance
Due 26 May 2009
Resolved 10 June 2009
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 May 2009 Resolved
Perform emergency drills underway in the presence of Marine Inspector.
Action required: 705 - Other - as specified
Due 12 June 2009
Resolved 10 June 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 May 2009 Resolved
Repair upper deck PORT forward handrail.
Due 26 May 2009
Resolved 10 June 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 May 2009 Resolved
Protect main engine control box wiring from chafing on both engines.
Due 26 May 2009
Resolved 10 June 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2008 Resolved
Properly wire outlet within void number 2, present arrangement does not meet code.
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 2 June 2008
Resolution: Received notification from o/o that appropriate boat cable installed.
Fire Fighting › Fire Pumps › Bushes
Issued 14 May 2008 Resolved
Repair leaking fire pump seal prior to commercial passenger operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2008
Resolved 15 May 2008
Resolution: Received notification that seal had been replaced with satisfactory test completed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 May 2008 Resolved
Replace retro-reflective tape on one adult life jacket (extra) until replacement completed jacket to be removed from vessel.
Due 14 May 2008
Resolved 2 June 2008
Resolution: Retro-reflective tape replaced on single jacket.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 May 2008 Resolved
Replace missing items from first aid kit, provided list.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2008
Resolved 15 May 2008
Resolution: Received notification of replacement items provided on board.
Construction/Loadline › Structures › Scuttle
Issued 14 May 2008 Resolved
In accordance with 46 CFR 179.360 install lanyard for forward hatch cover.
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 2 June 2008
Resolution: Received notification from o/o that chain lanyard has been installed.
Fire Fighting › Fire Pumps › Bushes
Issued 14 May 2008 Resolved
Repair leaking fire pump. System operable with adequate water supplied to all hydrants.
Action required: 705 - Other - as specified
Due 2 July 2008
Resolved 9 June 2008
Resolution: Rcvd call from owner that pump seal replaced and tested sat.
Electrical › Electric Generation Source (service) › Generator
Issued 2 May 2007 Resolved
Specifications for new generator installation were not provided to Sector Buffalo Inspections Division for approval.
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 31 May 2007
Resolution: Specifications were sent to the satisfaction of the Sector Buffalo Marine Inspections Office. Visual inspection revealed generator, cabeling, and overcurrent protection met the required standard.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 2 May 2007 Resolved
Missing machinery guard on the port engine alternator.
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 31 May 2007
Resolution: Machinery guard placed on the port engine alternator.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 23 May 2006 Resolved
provide documentation of eap and supervisor training
Due 24 June 2006
Resolved 6 September 2006
Resolution: Phone conversation with O/O w/follow-up fax find that EAP w/appropriate training and placarding complete however no notification completed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 23 May 2006 Resolved
replace retro material on 2 life preservers
Due 24 June 2006
Resolved 6 September 2006
Resolution: Replaced retro material on 2 life preservers.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 May 2006 Resolved
eliminate extension cord usage in fwd hold underneath bar area, also eliminate dead end wires
Due 24 June 2006
Resolved 6 September 2006
Resolution: Phone conversation w/follow-up fax from o/o present that extension cords and deadened wires removed from forward hold leading to galley area.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 23 May 2006 Resolved
eliminate engine oil leaks on all machinery in engine room
Due 24 June 2006
Resolved 6 September 2006
Resolution: Phone conversation w/ o/o with follow-up fax attesting to satisfactory completion of on going maintenance with Detroit engines.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 May 2006 Resolved
install guards on exposed gears, belts on generator
Due 24 June 2006
Resolved 6 September 2006
Resolution: Phone conversation w/ follow-up fax w/pic of guard on genset.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 May 2005 Resolved
Provide servicing documentation for 2 cylinders found over due for hydrostatic test.
Due 17 May 2005
Resolved 20 May 2005
Resolution: Received fax attesting to servicing of 2 units.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 17 May 2005 Resolved
Provide documentation attesting to self inspection of installed portable extinguishers.
Due 17 May 2005
Resolved 20 May 2005
Resolution: Record sheet provided listing identification numbering, location, hydro date and date serviced.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 17 May 2005 Resolved
Replace retrorelflective tape on 1 jacket identified during exam.
Due 17 May 2005
Resolved 20 May 2005
Resolution: Received fax attesting to the satisfactory replacement of retro tape.
Electrical › Electric Supply System (service) › Cable
Issued 17 May 2005 Resolved
Remove extension cords utilized throughout vessel.
Action required: 705 - Other - as specified
Due 17 May 2005
Resolved 17 May 2005
Resolution: Witnessed cords removal.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2005 Resolved
Provide additional wire supports and protection for installation IWO lazarette and engine space.
Due 17 May 2005
Resolved 20 May 2005
Resolution: Received fax attesting to satisfactory installation.
Construction/Loadline › Hull
Issued 15 November 2002 Resolved
Repair crack in bow skirting on starboard side.
Due 15 November 2002
Resolved 15 November 2002
Construction/Loadline › Penetrations
Issued 15 November 2002 Resolved
Remove port side shaft and inspect for wear. Recondition if necessary.
Due 15 November 2002
Resolved 15 November 2002
Construction/Loadline › Hull
Issued 15 November 2002 Resolved
Remove and renew wasted hull plating below chine on port side.
Due 15 November 2002
Resolved 15 November 2002
Lifesaving › Line-Throwing Appliances
Issued 22 April 2002 Resolved
Vessels crew needs to perform drills underway in presence of Coast Guard Marine Inspector; (man overboard & firefighting) (SPV decal to be issued at that time).
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 28 May 2002
Engineering
Issued 21 May 2001 Resolved
Generator, raw water cooling hose found to be damaged, corrected on scene prior to completion of inspection.
Condition: Unknown
Due 26 May 2001
Resolved 26 May 2001
Lifesaving
Issued 1 May 2000 Resolved
conduct drills and properly log drills in training log 185420
Condition: Unknown
Due 25 August 2000
Resolved 29 August 2000
Lifesaving
Issued 1 May 2000 Resolved
Replace expired red distress signal flares (night) and store in container as per 180.614
Condition: Unknown
Due 25 August 2000
Resolved 29 August 2000
Lifesaving
Issued 1 May 2000 Resolved
MARK UPPER DECK WITH MAXIMUM CAPACITY AS PER 185.602g
Condition: Unknown
Due 25 August 2000
Resolved 29 August 2000
Lifesaving
Issued 1 May 2000 Resolved
replace 4 approved 22 passenger life floats as per 180.200
Condition: Unknown
Due 25 August 2000
Resolved 29 August 2000
Accommodation/Occupational Safety
Issued 1 May 2000 Resolved
replace broken window glass at port side forward end of main deck in bar area
Condition: Unknown
Due 25 August 2000
Resolved 29 August 2000
Electrical
Issued 1 May 2000 Resolved
install weatherproof cover on 110 vac outlet on top deck aft. 183.210(3)(b)
Condition: Unknown
Due 25 August 2000
Resolved 29 August 2000
Lifesaving
Issued 1 May 2000 Resolved
First aid kit (2) not in compliance with 160.041
Condition: Unknown
Due 25 August 2000
Resolved 29 August 2000
Deck/Cargo
Issued 1 May 2000 Resolved
Insufficient anchor line, not of proper length. Install 5 - 7 times depth of operational area.
Condition: Unknown
Due 25 August 2000
Resolved 29 August 2000
Fire Fighting
Issued 28 April 1999 Resolved
STENCIL VESSEL NAME ON FIRE AXE.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Lifesaving
Issued 28 April 1999 Resolved
PROVIDE LIFE JACKET DONNING PLACKARD, MAIN DECK, UPPERDECK
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Unknown
Issued 28 April 1999 Resolved
PROVIDE 3/4 HIGH LEVEL ALARM FOR MSD HOLDING TANK.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Lifesaving
Issued 28 April 1999 Resolved
REMOUNT LIGHTS FOR LIFE FLOATS
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Lifesaving
Issued 28 April 1999 Resolved
REPLACE PAINTER LINES FOR ALL LIFE FLOATS
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Construction/Loadline
Issued 11 March 1999 Resolved
VESSEL CAN NOT OPERATE WITH PASSENGERS UNTIL IT IS IN COMPLIANCE WITH THE NEW BILGE SYSTEM REQUIREMENTS.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Fire Fighting
Issued 4 June 1998 Resolved
PROVIDE DOCUMENTATION OF SERVICING OF PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Engineering
Issued 4 June 1998 Resolved
DOUBLE CLAMP HOSE-TO-PIPING FITTING ON STBD ENGINE SEA WATER SUCTION FROM SEA CHEST
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Lifesaving
Issued 4 June 1998 Resolved
MARK STOWAGE AREAS FOR CHILD AND ADULT LIFE PRESERVERS.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Construction/Loadline
Issued 4 June 1998 Resolved
MAKE FORE PAEK ACCESSIBLE BY MAINTENANCING SCUTTLE.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Electrical
Issued 4 June 1998 Resolved
REMOVE DEAD-END CABLE (THREE CONDUCTOR, PREVIOUS SUPPLY TO HEAD HAND DRYERS) IN DECK IN GALLEY ELECTRICAL CLOSET.
Condition: Unknown
Due 4 June 1998
Resolved 4 June 1998
Fire Fighting
Issued 4 June 1998 Resolved
PROVIDE ADEQUATE PRESSURE TO FIRE MAIN SYSTEM WITH ELECTRICAL FIRE PUMP.
Condition: Unknown
Due 4 June 1998
Resolved 10 July 1998
Lifesaving
Issued 4 June 1998 Resolved
PROVIDE UPDATED FIRST AID KIT.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Navigation
Issued 4 June 1998 Resolved
OBTAIN UPDATED "RULES OF THE ROAD" AND "LIGHT LIST".
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Construction/Loadline
Issued 4 June 1998 Resolved
MAKE SEWAGE PUMP-OUT PIPING PENETRATION IN THE FORWARD STEERING SPACE BULKHEAD, PORT SIDE, WATERTIGHT.
Condition: Unknown
Due 4 June 1998
Resolved 4 June 1998
Lifesaving
Issued 4 June 1998 Resolved
ATTACH PAINTER TO LIFE RING BUOY AT BRIDGE.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Documentation
Issued 4 June 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Lifesaving
Issued 30 May 1997 Resolved
REPAINT ALL RING BUOYS INT'L ORANGE, INSTALL RETRO TAPE IN 4 LOCATIONS, RELABEL W/VESSEL NAME._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1997
Resolved 23 July 1997
Lifesaving
Issued 30 May 1997 Resolved
RENEW 3 RED FLARES PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1997
Resolved 23 July 1997
Lifesaving
Issued 30 May 1997 Resolved
RENEW PADDLES IN ALL LIFEFLOATS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1997
Resolved 23 July 1997
Lifesaving
Issued 2 May 1996 Resolved
LABEL LIFEFLOAT PADDLES WITH VESSEL NAME.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 2 May 1996 Resolved
LABEL FLARE BOX "DISTRESS SIGNALS"._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 2 May 1996 Resolved
RENEW 60' OF LINE ON RING BUOY.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 2 May 1996 Resolved
LABEL CAPACITY OF EACH LIFEFLOAT.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 2 May 1996 Resolved
RELABEL CHILD PFD STOWAGE.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Fire Fighting
Issued 2 May 1996 Resolved
CHANGE VESSEL NAME ON FIRE AXE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Documentation
Issued 2 May 1996 Resolved
CHANGE VESSEL NAME ON FCC STATION LICENSE AND FCC SAFETY CERT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Lifesaving
Issued 3 May 1995 Resolved
Provide 6 red hand held flares.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Lifesaving
Issued 3 May 1995 Resolved
Repaint 4 lifefloats International Orange and relabel with passenger capacity and vessels name.
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Lifesaving
Issued 3 May 1995 Resolved
Provide suitable water tight containers for all flares.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Construction/Loadline
Issued 5 May 1994 Resolved
Permanently affix draft marks to hull at next drydock.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Lifesaving
Issued 5 May 1994 Resolved
Provide primary L/S equipment for 50% of total persons prior to operating in Coastwise service.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Documentation
Issued 5 May 1994 Resolved
Provide FCC certifcate prior to operating more than 1000' from shore.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Documentation
Issued 23 November 1993 Resolved
The stability letter issued on 04 May 93 has incorrect data on the number of upper deck passengers allowed and references maximum drafts which are not marked. Provide corrected stability letter and provide hull freeboard markings and upper deck passenger limiting signs per 46 CFR 185.30-3.
Condition: Unknown
Due 23 November 1993
Resolved 23 November 1993
Lifesaving
Issued 4 August 1993 Resolved
Provide a licensed mate or second master during carriage of passengers. The licensed individual shall be capable of operating all emergency_x001C_ systems. This item remains in effect until emergency drills are satisfactorily conducted, but must be corrected by the compliance date.
Condition: Unknown
Due 4 August 1993
Resolved 4 August 1993
Documentation
Issued 4 August 1993 Resolved
Provide onboard the original stability letter not later than the compliancedate.
Condition: Unknown
Due 4 August 1993
Resolved 4 August 1993
Electrical
Issued 4 August 1993 Resolved
Provide correctly sized generator circuit breaker per MSC letter of 03 June1993 not later than the compliance date.
Condition: Unknown
Due 4 August 1993
Resolved 4 August 1993
Deck/Cargo
Issued 5 May 1993 Resolved
Provide suitable sized anchor line or prove the 3/4 inch line is adequate for a 90 pound anchor not later than the compliance date.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Lifesaving
Issued 5 May 1993 Resolved
Provide means for the master to communicate with the crew while on the main deck during retreival of persons in the water not later than the compliance date.
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Unknown
Issued 5 May 1993 Resolved
Complete vessel plan approval not later than the compliance date.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Lifesaving
Issued 5 May 1993 Resolved
Conduct emergency drills with the assigned vessel crew not later than the compliance date.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Lifesaving
Issued 5 May 1993 Resolved
Provide one additional deckhand to assist in emergencies until drills are conducted to prove standard crew is sufficient.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993

Casualty record · 1

13 June 2026Routine · role: Involved in a Marine Casualty · activity 8413701
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.