MAURY USCG vessel records Sign in
← All vessels

REF STAR

REF STAR is a 1984 freight ship. The Coast Guard has recorded 26 inspections since 1996, most recently in January 2010, along with 29 deficiencies and 1 operational control.

Records from 1996 to 2010. Most recent: operational control imposed, 27 January 2010.

Built
1984
Last inspected
27 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8415550 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
385705
Flag
RUSSIA
—
Maury page id
psix-385705

Inspections, by type

…with no type recorded14
Years with a record 13 calendar years (1996–2010)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it12383 - Convention (Subpart B), Gross Ton
4780 - Convention (Subpart B), Net Ton
11871 - Dead Weight, Ton
19111 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

27 January 2010 Ballast Water Examination · MARPOL Annex VI Survey · PII Safety Exam · Deficiency Check · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3668036
9 February 2009 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3411754
3 June 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3226197
1 April 2008 MARPOL Annex V Examination · ISPS III Exam · Deficiency Check · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3172102
23 January 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3131298
26 July 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2725447
2 March 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2594600
11 August 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2459861
8 August 2005 NPV Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2455462
20 May 2005 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2363066
14 February 2005 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2291942
10 August 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2162328
26 March 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1763359
7 February 2002 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1482223
27 November 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 295827
3 May 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 289580
30 January 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 286347
10 November 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 434520
21 August 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 419588
18 February 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 516641
11 August 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 406555
4 November 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 396754
30 April 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 390592
22 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 200522
22 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 760048
21 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 388132

Deficiency record · 29

Communications › Internal Communications System › Sound-powered Telephone
Issued 27 January 2010 Resolved
0674 - Emergency equip. for 2-way commun. - PSCO was unable to establish communication with the bridge from the steering gear room for over 30 minutes. Chief Engineer stated sound powered phone was inoperable. Engineers must be able to maintain communication with the bridge from the steering gear room - SOLAS 74/78 II-1 Reg 29
Action required: 705 - Other - as specified
Due 28 January 2010
Resolved 3 February 2010
Resolution: Received, reviewed and accepted class report from, Russian Maritime Register of Shipping, stating the deficiency was rectified. PSC team went back to vessel, conducted test of the comms between the steering room and the navigation bridge, all test sat.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 27 January 2010 Resolved
0750 - Fire Prevention - PSCO observed numerous fuel oil leaks on the high pressure supply and low pressure return lines on all four ship service generators. Also noted all generators leaking fuel from canister filters. Generator number four has an excessive lube oil leak from the cylinder head. All leaks noted present a substantial fire hazard - 74 SOLAS II-2 Reg 15
Action required: 705 - Other - as specified
Due 28 January 2010
Resolved 3 February 2010
Resolution: Received, reviewed and accepted class report from, Russian Maritime Register of Shipping, stating the deficiency was rectified. PSC team went back to vessel, tested all generators, observed no more significant leaks, the area was clean and free of oil.
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 27 January 2010 Resolved
1420 - Cleanliness of engine room - PSCO found stripping valves on the MDE lube oil tank and boiler fuel oil supply tank do not operate as designed. Neither valve will secure. Crew utilizes wooden handle and rag to slow the leaking liquids. Inability to secure these valves presents a serious fire hazard - 74 SOLAS II-2 Reg 15
Action required: 705 - Other - as specified
Due 28 January 2010
Resolved 3 February 2010
Resolution: Received, reviewed and accepted class report from, Russian Maritime Register of Shipping, stating the deficiency was rectified. PSC team went back to vessel, observed both stripping valves to be operating as designed.
Engineering › Bilge Water Management System › Not Operational
Issued 27 January 2010 Resolved
1420 - Cleanliness of engine room - PSCO found as a result of the numerous leaks and lack of containment that the engine room bilges are coated with petroleum and water and are not being maintained. This condition presents a serious fire hazard - SOLAS 74 II-2 Reg 15
Action required: 705 - Other - as specified
Due 28 January 2010
Resolved 3 February 2010
Resolution: Received, reviewed and accepted class report from, Russian Maritime Register of Shipping, stating the deficiency was rectified. PSC team went back to vessel, observed clean bilges and no existing significant leaks.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 9 February 2009 Resolved
Double jacketing for high pressure fuel line on main engine is tattered. This presents a fire hazard in the engine room.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 February 2009
Resolution: Double jacketing for high pressure fuel line was replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 February 2009 Resolved
Salt water cooling outlet for main engine has numerous temorary patches. Vessel is to make repairs during next drydock in June 2009.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2010
Resolved 27 January 2010
Resolution: Repairs made in dry-dock
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 1 April 2008 Resolved
The fuel oil piping on the main deck is cracked and has a soft patch. A requirement was issued for permanent repairs and a hydrostatic tested of the piping prior to conducting bunkering operations in U.S waters.
Action required: 703 - Prior to bunkering operations
Due 1 April 2008
Resolved 3 June 2008
Resolution: Received a class report from Russian Maritime Register of Shipping stating that the piping has been repaired, tested, and found to be satisfactory.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 1 April 2008 Resolved
Vessel has not conducted hydrostatic test of the fuel and lube oil piping in accordance with U.S. regulations. A requirement was issued for a test of the piping at one and half times the working pressure prior to conducting bunkering operations in U.S waters.
Action required: 703 - Prior to bunkering operations
Due 1 April 2008
Resolved 3 June 2008
Resolution: Received a class report from Russian Maritime Register of Shipping stating that the fuel and lube oil piping has been hydrostatically tested in accordance with U.S. regulations and found satisfactory.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 23 January 2008 Resolved
Vessel SOPEP is out of date. Emergency contact list has not been updated since June 2007.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2008
Resolution: Verified that the SOPEP is current and has been updated.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 23 January 2008 Resolved
Vessel's line throwing apparatus are expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2008
Resolution: New line throwing devices were purchased.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 23 January 2008 Resolved
Aft bulkhead for the engine control room was cracked in two locations.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2008
Resolution: Received a class report from Russian Maritime stating that the bulkhead has been repaired and is in satisfactory condition.
Fire Fighting › Means of Escape › Blocked
Issued 23 January 2008 Resolved
Engine parts and equipment are blocking walkways in the engine room, preventing clear means of escape from the engine room.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2008
Resolution: Confirmed during the exam that the walkways are no longer blocked, and there is now clear means of escape from the engine room.
Construction/Loadline › Structures › Deck Plating
Issued 26 July 2006 Resolved
Secound landing entering emergency fire pump area, is wasted. repair or replace to the satisfaction of attending U.S Coast Guard Inspectors.
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 23 January 2008
Resolution: Coast Guard Inspector witnessed satisfactory repair of secondary landing.
Engineering › Freshwater System (injector cooling) › Piping
Issued 14 February 2005 Resolved
MDE #2 L/O cooler is wasted and weeping at the end cap. Excessive wastage was observed on cooler as well. Class Surveyor to make recommendation for permanent repairs and to FAX report to COTP Baltimore.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 20 May 2005
Resolution: Received Class report attesting to the satisfactory permanent repair of the L/O Cooler.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 14 February 2005 Resolved
Leaking pump observed on MSD system. Pump is leaking liquid onto interior of the vessel. Repair as original to the satisfaction of Administration.
Action required: 705 - Other - as specified
Due 31 March 2005
Resolved 20 May 2005
Resolution: Recieved class report attesting to repair of pump.
Stability › Weathertight Integrity › General
Issued 26 March 2003 Resolved
Noted hatch cover over emergency generator room was wasted. Once repaired have class/flag attest to repairs prior to next U.S. port. Send servicing report by fax to U.S.C.G. LEGACY COMPONENT DESC: Hatch cover
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 10 August 2004
Resolution: Item cleared during AEF.
Electrical › Electric Generation Source (emergency)
Issued 26 March 2003 Resolved
Noted emergency generator was out for service. Once repaired have class/flag attest to repairs. Send servicing report by fax U.S.C.G. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2003
Deck/Cargo
Issued 30 January 2001 Resolved
REPLACE/RENEW AS ORIGINAL THE 2 & 1/2 FOOT LONG PIPE FOR THE DECK WASH SYSTEM THAT IS LOCATED ABOVE THE #2 & #3 FIRE PUMPS. CORRECT NLT 13FEB01. SOLAS 74(UNAMEND) I/11
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Fire Fighting
Issued 30 January 2001 Resolved
REPAIR AS ORIGINAL THE #2 FIRE PUMP WHICH CURRENTLY OPERATES WITH A BURNINGSMELL AND SMOKES. CORRECT NLT 13FEB01. SOLAS 74(UNAMEND) I/11
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Fire Fighting
Issued 30 January 2001 Resolved
REPAIR AS ORIGINAL VENTILATION DAMPNERS IN ENGINE ROOM AS NECESSARY. CORRECT NLT 13FEB01. SOLAS 74(UNAMEND) 1/11
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Engineering
Issued 30 January 2001 Resolved
REPAIR AS ORIGINAL THE EMERGENCY GENERATOR FUEL OIL EMERGENCY SHUTDOWN. CORRECT NLT 13FEB01. SOLAS 74(UNAMEND) II-2/54(b)
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Documentation
Issued 30 January 2001 Resolved
CLASS TO APPROVE CARGO SECURING MANUAL. CORRECT NLT 13FEB01. _x001C_ SOLAS(UNAMEND) VI/5.6
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Lifesaving
Issued 21 August 1998 Resolved
HAVE CLASS TO EXAMINE FOREPEAK ROOM STARBOARD SIDE CONTAINING WINDLASS GEARTO MAKE DETERMINATION OF SOURCE OF F/O EMITTANCE OF HEAVY FUMES.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Lifesaving
Issued 21 August 1998 Resolved
SECURE ALL RUGS/MATS IN ALL PASSAGEWAYS.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Lifesaving
Issued 21 August 1998 Resolved
REPLACE/DISCARD THE FOOD RATIONS THAT DO HAVE AN AIR TIGHT SEAL AS PER SOLAS 74(AMENDED) REG III/41.8.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Lifesaving
Issued 21 February 1996 Resolved
PROVIDE AND POST MUSTER LIST ON NAVIGATION BRIDGE AND IN ENGINE ROOM. SOLAS 74 (AMENDED) III/8
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Fire Fighting
Issued 21 February 1996 Resolved
PROVIDE COPY OF SERVICING REPORT FOR ALL ON BOARD PORTABLE FIRE EXTINGUISHERS TO INCLUDE RECEIPTS FOR NEW PORTABLE FIRE EXTINGUISHERS. SOLAS 74 (UNAMENDED) II-2/7(e)
Condition: Unknown
Due 24 February 1996
Resolved 26 February 1996
Accommodation/Occupational Safety
Issued 21 February 1996 Resolved
REPAIR, RENEW RAILING ON STARBOARD SIDE LADDER NEXT TO PILOT HOUSE AND ON WALKWAY FORWARD OF PILOT HOUSE.
Condition: Unknown
Due 1 May 1996
Resolved 1 May 1996
Lifesaving
Issued 21 February 1996 Resolved
RENEW RETRO-REFLECTIVE MATERIAL WHERE DETERIORATED AND WORN ON VARIOUS LIFERING BUOYS. SOLAS 74(AMENDED) III/30.2.7
Condition: Unknown
Due 24 February 1996
Resolved 26 February 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.