MAURY USCG vessel records Sign in
← All vessels

SHELL KAT

SHELL KAT is a 1993 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 1993, most recently in March 2024, along with 72 deficiencies.

Records from 1993 to 2024. Most recent: inspection, 12 March 2024.

Built
1993
Last inspected
12 March 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK7403
385724
Flag
UNITED STATES
—
Maury page id
psix-385724

Inspections, by type

…with no type recorded1
Years with a record 28 calendar years (1993–2024)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 45

12 March 2024 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7877958
22 February 2023 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7640453
6 April 2022 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7426280
18 March 2021 Internal Structural Exam · Drydock Exam · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7235582
15 July 2019 COI Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6732307
3 April 2019 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6651860
25 September 2018 Internal Structural Exam · Drydock Exam · In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6547528
2 March 2018 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6364076
15 December 2016 DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6058393
29 September 2016 Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6012157
19 May 2016 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5870250
14 October 2015 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5750606
9 October 2015 Type not recorded
No type recorded · Station Fort Myers Beach · USCG Southeast District (CGD-SE) · Activity 5740512
14 May 2014 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4852515
21 February 2012 Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4248264
7 December 2010 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3893318
19 February 2009 Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3411525
15 May 2008 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3201781
7 May 2007 In-Service Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2925066
26 February 2007 Hull Examination · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2877567
23 May 2006 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2656463
8 April 2005 Hull Examination · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2245735
25 May 2004 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2064910
19 February 2003 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1745901
22 November 2002 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1706859
9 January 2002 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1478448
13 September 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1071527
31 July 2001 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1069573
14 May 2001 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1063060
27 March 2001 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1060745
31 January 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1058765
3 January 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1057447
2 March 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 815798
22 December 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1403077
11 January 1999 Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1416832
15 January 1998 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1398849
25 July 1997 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1116461
6 May 1997 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1097983
15 January 1997 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1449998
11 January 1996 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1079450
12 July 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 880411
13 January 1995 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 832521
8 March 1994 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1164640
27 April 1993 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1143300
15 January 1993 Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 842080

Deficiency record · 72

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2021 Resolved
Provide fuel tank ventilation blower/engine start interlock in accordance with 46 CFR 182.15-45. To be completed within 14 days. Crew must operate blowers for two minutes prior to starting engines and log.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 6 April 2022
Resolution: Satisfactory interlock installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 December 2019 Resolved
Life float missing required paddles, floating water light, and required markings. Restricted vessel to no more than 3NM from land. 46CFR180.175 46CFR185.604
Action required: 705 - Other - as specified
Resolved 6 December 2019
Resolution: Verified vessel rep installed correct paddles, floating water light, and applied required markings to life float.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 January 2017 Resolved
Lifejacket missing Type I approval label. (46 CFR 180.71)
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 11 January 2017
Resolution: Purchased new Type I PFD.
Construction/Loadline › Hull › Side Shell
Issued 19 May 2014 Resolved
Crop and insert a 18" x 18" area of the sideshell around pit wasted through in the port head IAW 46 CFR 176.802.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2014
Navigation › Piloting/Steering › Magnetic Compass
Issued 19 May 2014 Resolved
Repair magnetic comppas light IAW 46 CFR 184.402.
Due 23 May 2014
Resolved 19 May 2014
Lifesaving › Hand Flares › Quantity
Issued 19 May 2014 Resolved
Provide the proper amount of flares IAW 46 CFR 180.68.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2014
Lifesaving › Buoyant Apparatus › Approval
Issued 19 May 2014 Resolved
Provide a survival craft or EPIRB for the vessels route IAW 46 CFR 180.200 & 185.728.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 May 2014 Resolved
Provide proper amount of asprin for first aid kit IAW 46 CFR 184.710.
Due 23 May 2014
Resolved 19 May 2014
Fire Fighting › Ventilation Systems › Operating Controls
Issued 19 May 2014 Resolved
Prove proper operation of the fixed fire fighting system IAW 46 CFR 176.810.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2014
Engineering › Bilge Water Management System › Pump
Issued 19 May 2014 Resolved
Replace forward bilge pump stbd side in the #2 void IAW 46 CFR 176.804.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2014
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 19 May 2014 Resolved
Provide updated list of employees in the drug consortium & proof of EAP Training IAW 46 CFR Part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2014
Communications › Radio Communications › VHF Radiotelephone
Issued 21 February 2012 Resolved
Provide a radio telephony safety certificate and marine radio operator permit IAW 46 CFR 184.502.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2012
Navigation › Piloting/Steering › Magnetic Compass
Issued 21 February 2012 Resolved
Prove proper operation of magnetic compass light IAW 46 CFR 184.402. Vsl restricted to daytime operations until corrected.
Action required: 705 - Other - as specified
Due 28 February 2012
Resolved 23 February 2012
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 February 2012 Resolved
Make thru bulkhead connection water tight between stbd compartments 4 and 5 IAW 46 CFR 179.320(c).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 February 2012 Resolved
Provide ammonia inhalants in first aid kit IAW 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 28 February 2012
Resolved 23 February 2012
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 21 February 2012 Resolved
[name withheld] stowage with accurate quantity IAW 46 CFR 185.604(f).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2012
Engineering › Bilge Water Management System › Pump
Issued 21 February 2012 Resolved
Prove proper operation of aft/port bilge pump IAW 46 CFR 182.520(e).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2012
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 21 February 2012 Resolved
Provide EAP supervisor and employee training, display hotline number, and a copy of latest MIS report IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 28 February 2012
Resolved 28 February 2012
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 7 December 2010 Resolved
Provide an additional B-II portable fire extinguisher for the accomadation area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2010
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 December 2010 Resolved
Seal cable penetrations in the #4 void and insure they are watertight IAW 46 CFR 183.10-20 (e). The cite is not available in MISLE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2010
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 May 2008 Resolved
Repair ring lifebuoy light.
Due 20 May 2008
Resolved 15 May 2008
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 15 May 2008 Resolved
Place 1 portable light on vessel
Due 20 May 2008
Resolved 16 May 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 7 May 2007 Resolved
Install all same type of fix fire extinguishing cylinder and must CG approval.
Due 14 May 2007
Resolved 16 May 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 February 2007 Resolved
Properly secure bow ladders
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 February 2007 Resolved
Replace expired items in first aid kit.
Due 5 March 2007
Resolved 28 February 2007
Communications › Audible Communications › Horn/Whistle
Issued 26 February 2007 Resolved
Repair horn
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2007
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 26 February 2007 Resolved
Post emergency instructions
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 26 February 2007 Resolved
Post emergency broadcast card
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2007
Lifesaving › Lifejacket/PFD (Type V) › Condition
Issued 26 February 2007 Resolved
Repair ring life buoy light
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2007
Electrical › Electric Supply System (service) › Cable
Issued 26 February 2007 Resolved
Removed dead end wiring from vessel
Due 5 March 2007
Resolved 28 February 2007
Electrical › Electric Generation Source (service) › Power Requirement
Issued 26 February 2007 Resolved
Removed wing nut forward compartment on the batteries and install a cover on the batteries.
Due 5 March 2007
Resolved 28 February 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 26 February 2007 Resolved
Store fire extinguisher in a bracket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2007
Lifesaving › Lifefloat › Serviceable
Issued 23 May 2006 Resolved
Make repairs to life float in way of gashes. Also place number of person capacity on both sides of the life float. Refresh the lettering of vsl's name on both sides.
Action required: 705 - Other - as specified
Due 30 May 2006
Resolved 31 May 2006
Resolution: Rcvd notification that requirements have been met.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 23 May 2006 Resolved
Provide annual servicing report for fixed fire extinguishing system prior to the carriage of passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2006
Resolution: Rcvd a copy of report
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 8 April 2005 Resolved
PROVIDE CURRENT SAFETY RADIO CERTIFICATE FOR VESSEL.
Due 5 May 2005
Resolved 11 April 2005
Construction/Loadline › Structures › Manhole
Issued 8 April 2005 Resolved
RENEW BOW HATCH GASKETS OR RENEW COMPLETE HATCHES PORT AND STARBOARD SIDES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 11 April 2005
Construction/Loadline › Structures › Manhole
Issued 8 April 2005 Resolved
RENEW AFT SEAT GASKETS.
Due 5 May 2005
Resolved 11 April 2005
Construction/Loadline › Penetrations › Gasket
Issued 8 April 2005 Resolved
SEAL UP STERN CONTROL CABLE PENETRATIONS PORT AND STARBOARD SIDE OR STERN SHEET.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 11 April 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 April 2005 Resolved
UPDATE/RENEW FIRST AID KIT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 11 April 2005
Electrical › Electrical Distribution System (service) › Switch
Issued 8 April 2005 Resolved
LABEL ALL CONSOLE ELECTRICAL SWITCHES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 11 April 2005
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 8 April 2005 Resolved
APPLY PROPER AMOUNT OF RETROREFLECTIVE TAPE TO BOTH BOUYANT APPARATUS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2005
Resolved 11 April 2005
Construction/Loadline › Hull › Bottom Plating
Issued 3 February 2005 Resolved
PRESSURE WASH AND PUMP OUT #1 VOIDS, PORT AND STARBOARD FOR FURTHER INSPECTION.
Due 3 March 2005
Resolved 4 March 2005
Construction/Loadline › Hull › Bottom Plating
Issued 3 February 2005 Resolved
GRIND OUT AND CLAD WELD THE IDENTIFIED DEEP PITS IN WAY OF #2 STARBOARD VOID.
Due 3 March 2005
Resolved 4 March 2005
Construction/Loadline › Hull › Bottom Plating
Issued 3 February 2005 Resolved
RENEW BOTTOM PLATING WHERE PITTED AT KEEL IN WAY OF #2 PORT VOID.
Due 3 March 2005
Resolved 4 March 2005
Construction/Loadline › Hull › Bottom Plating
Issued 3 February 2005 Resolved
CLEAN #4 STARBOARD VOID FOR FURTHER INSPECTION.
Due 3 March 2005
Resolved 4 March 2005
Construction/Loadline › Hull › Bottom Plating
Issued 3 February 2005 Resolved
REMOVE OLD WATER TANK AND OPEN UP HEAD DECK FOR FURTHER EXAMINATION IN WAY OF 4 PORT HEAD SPACE.
Due 3 March 2005
Resolved 4 March 2005
Construction/Loadline › Hull › Bottom Plating
Issued 22 November 2004 Resolved
SCRUB ALL PITTED AREAS OF ALL BILGES FOR FURTHER INSPECTION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2004
Resolved 3 February 2005
Construction/Loadline › Hull › Bottom Plating
Issued 22 November 2004 Resolved
PROVIDE REPAIR PROPOSAL FOR PITTED AREAS OF BOTTOM PLATE IN WAY OF #2 AND #3 STARBOARD VOIDS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2004
Resolved 3 February 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 November 2004 Resolved
REPAIR FRACTURE IN WAY OF BOW LADDER MOUNTING BRACKET.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2004
Resolved 4 March 2005
Construction/Loadline › Hull › Bottom Plating
Issued 22 November 2004 Resolved
CLEAN #3 PORT VOID FOR FURTHER INSPECTION.
Due 3 March 2005
Resolved 4 March 2005
Construction/Loadline › Hull › Bottom Plating
Issued 22 November 2004 Resolved
REMOVE FUEL TANK FROM #3 STARBOARD VOID AND RENEW BOTTOM PLATING WHERE PITTED NEAR KEEL.
Due 3 March 2005
Resolved 4 March 2005
Lifesaving › Buoyant Apparatus
Issued 25 May 2004 Resolved
RENEW PENNANTS ON BOUYANT APPARATUS.
Due 15 June 2004
Resolved 28 May 2004
Electrical › Electric Generation Source (service)
Issued 19 November 2002 Resolved
PROVIDE COVERS FOR PORT AND STARBOARD BATTERIES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2002
Resolved 22 November 2002
Construction/Loadline › Hull
Issued 19 November 2002 Resolved
REMOVE WORN BEACHING GUARD ON PORT HULL FORWARD AND PROPERLY CROP AND RENEW INSERT WHERE HULL IS WORN. LEGACY COMPONENT DESC: Bottom Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2002
Resolved 22 November 2002
Engineering › Fuel Oil Service System
Issued 19 November 2002 Resolved
PROVIDE ACCEPTABLE MEANS TO OPERATE FUEL OIL SHUT-OFF VALVE AT PORT AND STARBOARD TANKS. LEGACY COMPONENT DESC: Valve, Control
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2002
Resolved 22 November 2002
Electrical › Electrical Distribution System (service)
Issued 19 November 2002 Resolved
REPAIR WIRING TO BILGE PUMP IN WAY OF STARBOARD FUEL TANK COMPARTMENT. LEGACY COMPONENT DESC: Wiring
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2002
Resolved 22 November 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 19 November 2002 Resolved
SECURE FIXED FIREFIGHTING SYSTEM BOTTLE TO BULKHEAD IN STARBOARD FUEL TANK COMPARTMENT. LEGACY COMPONENT DESC: Tanks
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2002
Resolved 22 November 2002
Electrical › Electric Supply System (service)
Issued 19 November 2002 Resolved
REPLACE WINGNUTS ON BATTERY TERMINALS WITH PERMANENT TYPE FASTENERS. LEGACY COMPONENT DESC: Battery Conductor
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2002
Resolved 22 November 2002
Lifesaving
Issued 22 December 1999 Resolved
UPDATE FIRST AID KIT WITH 10 AMMONIA INHALENTS.
Condition: Unknown
Due 13 March 2000
Resolved 13 March 2000
Navigation
Issued 22 December 1999 Resolved
PROVIDE LIGHT FOR MAGNETIC COMPASS. VESSEL RESTRICTED TO DAYLIGHT OPS UNTILCORRECTED.
Condition: Unknown
Due 13 March 2000
Resolved 13 March 2000
Accommodation/Occupational Safety
Issued 15 January 1998 Resolved
RAISE PASSENGER RAILS TO 39 1/2"._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Documentation
Issued 15 January 1998 Resolved
RENEW FCC SAFETY RADIOTELEPHONY CERTIFICATE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Electrical
Issued 15 January 1998 Resolved
PROVIDE SUITABLE FLASHLIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 January 1998
Resolved 4 March 1998
Lifesaving
Issued 15 January 1998 Resolved
INSTALL INTERNATIONAL ORANGE 24" RING BUOY W/RETRO TAPE, LABELED W/VESSEL NAME._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 January 1998
Resolved 4 March 1998
Accommodation/Occupational Safety
Issued 15 January 1997 Resolved
RAISE PASSENGER RAILS TO 39 1/2"_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Lifesaving
Issued 11 January 1996 Resolved
REPAINT AND RELABEL BUOYANT APPARATUS.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Navigation
Issued 11 January 1996 Resolved
PRIOR TO OPERATING REPAIR OR RENEW MASTHEAD/ANCHOR LIGHT.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Navigation
Issued 13 January 1995 Resolved
Repair starboard navigation light prior to sailing.
Condition: Unknown
Due 13 January 1995
Resolved 13 January 1995
Lifesaving
Issued 13 January 1995 Resolved
Repair buoyant appratus waterlight prior to sailing.
Condition: Unknown
Due 13 January 1995
Resolved 13 January 1995
Engineering
Issued 8 March 1994 Resolved
Repair emergency fuel shutoffs.
Condition: Unknown
Due 21 March 1994
Resolved 21 March 1994
Fire Fighting
Issued 8 March 1994 Resolved
Perform annual service on fixed halon system.
Condition: Unknown
Due 21 March 1994
Resolved 21 March 1994
Documentation
Issued 15 January 1993 Resolved
Provide FCC certificate. Vessel limited to not more than 1000 feet from shore until complete.
Condition: Unknown
Due 15 January 1993
Resolved 15 January 1993

Ownership record