Records from 1992 to 2016. Most recent: inspection, 7 January 2016.
Inspection history · 25
7 January 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5793078
6 January 2011
PII Safety Exam · Ballast Water Examination · Administrative Inspection · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3768651
22 December 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3653901
17 March 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3444461
15 January 2009
Ballast Water Examination · Random ISPS/MTSA/PSC · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3394773
3 October 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3337755
24 October 2007
Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3086256
5 April 2007
PII Safety Exam · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2903059
11 January 2006
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2565196
17 December 2004
ISPS II Exam · PII Safety Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2269900
25 July 2003
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1924704
11 June 2003
Periodic Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1813971
11 June 2003
Security Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1815082
23 September 2002
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1680794
24 July 2001
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 292214
14 April 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 172274
2 February 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 19499
26 May 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 278308
3 August 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 431436
3 August 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 431437
19 December 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 423790
13 August 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 419284
22 January 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 503632
20 November 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 410260
14 October 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 129744
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 6 January 2011
No resolution recorded
2120 Every ship of 400 Gross tons and above shall carry a Garbage Management Plan which the crew shall follow. The vessel does not have a Garbage Management Plan. Marpol Annex V Reg 9 (2)
Action required: 15 - Rectify deficiencies by next port
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 6 January 2011
No resolution recorded
0150 The Condition of the ship and its equipment shall be maintained to conform with the provisions of the convention. In accordance with the IOPP the vessel has an incinerator on board. The incinerator is not working. Marpol Annex I reg 6 (4.1) 70ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 22 December 2009
Resolved
Vessel did not log pre-arrival test in vessel log book.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 10 May 2010
Resolution: Pre-arrival test was logged in log book.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 22 December 2009
Resolved
Garbage Rocord Book has not been signed by the Master after each compleated page.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 10 May 2010
Resolution: Master''s signature was on each completed page.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 22 December 2009
Resolved
Vessel has not submitted a Ballast Water Report. Master has been counseled on proper ballast water practices.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 10 May 2010
Resolution: Documentation was produced to verify Ballast Water Reports were being submitted.
Fire Fighting › Fire Pumps › Casing
Issued 5 April 2007
Resolved
Main fire pump inoperable due to cracked pump casing on fire pump (17A)
Correct to the satisfaction of class
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2007
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 5 April 2007
Resolved
Emergency fire pump is unable to take proper suction due to blocked sea chest. (17a)
Correct to the satisfaction of class
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2007
Lifesaving › Launching Appliances › Winch
Issued 5 April 2007
Resolved
Port rescue boat is unable to be properly launched due to inoperable hydraulic control block in that the control block will not hold the load of the boat. (17a)
Correct to the satisfaction of class
Stbd davit rigged to deploy rescue boat until parts are received. Approved by flag & class. Date extended until 11 June 2007.
Action required: 705 - Other - as specified
Due 11 June 2007
Resolved 24 October 2007
Resolution: Recieved class report.
Engineering › Fuel Oil Service System › Piping
Issued 5 April 2007
Resolved
#2 Generator & bow thruster prime mover fuel system between fuel pump and injectors is not protected with a jacketed piping system to contain fuel during line failure. (50a)
Correct to the satisfaction of class
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 11 April 2007
Engineering › Fuel Oil Service System › Piping
Issued 5 April 2007
Resolved
Engine room fuel system piping lacks shielding at flanges & joints in the vicinety of ignition sources (electrical switchboards & panal boards). (17a)
Correct to the satisfaction of class
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 April 2007
Resolved
IOPP certificate, Form A particulars do not match installed equipment . OWS & sensor equipment manufacture & throughput do not match listed equipment. Installed OWS has been modified (oil sensor on top of heli-sep coalescer wiring harness not approved wiring). Bypass hose also in place between re-circulation piping & overboard discharge piping. (17a)
Correct to satisfaction of class
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2007
Resolution: New IOPP issued to reflect valid equipment. Equipment restored to CG approval status.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 11 January 2006
Resolved
Rescue boat engine will not start.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2006
Resolution: Rescue boat engine was repaired & operates satisfactorily.
Navigation › Piloting/Steering
Issued 26 September 2002
Resolved
Provide a Maneuvering Facts sheet with Warning Statement on bridge.
33 CFR 164.35(g) LEGACY COMPONENT DESC: Maneuvering Information Fact Sheet
Action required: 705 - Other - as specified
Due 23 October 2002
Resolved 25 July 2003
Resolution: Manuevering diagram provided on the bridge.
Accommodation/Occupational Safety
Issued 24 July 2001
Resolved
Vessel needs to adjust and approve operation of fire doors to galley and base of stair tower._x001C_ SOLAS 74/78 11-2/47
Condition: Unknown
Due 17 December 2001
Resolved 23 October 2002
Resolution: Vessel has adjusted and approved of fire door operation for the galley and bas of stair doors.
Lifesaving
Issued 24 July 2001
Resolved
Vessel had to remove all combustible material underneath stairway next to galley prior to getting underway.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001