MAURY USCG vessel records
← All vessels

REGAL BAY

REGAL BAY is a 1993 freight ship. The Coast Guard has recorded 29 inspections since 2016, most recently in July 2026, along with 12 deficiencies and 5 operational controls.

Records from 2016 to 2026. Most recent: inspection, 21 July 2026.

Built
1993
Last inspected
21 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9053658
385838
Flag
BAHAMAS, THE
Maury page id
psix-385838

Inspections, by type

…with no type recorded9
Years with a record 11 calendar years (2016–2026)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it11323 - Convention (Subpart B), Gross Ton
8653 - Convention (Subpart B), Net Ton
16958 - Displacement, Metric Ton
10520 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 29

21 July 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8443456
17 March 2026 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8327467
27 February 2026 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8314542
24 June 2025 PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8152260
14 August 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7980102
12 August 2024 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7979985
18 September 2023 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7791582
12 September 2023 PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7787532
14 March 2023 PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7650477
12 September 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7555351
28 April 2022 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7439708
28 April 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7439823
20 April 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7434138
10 February 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7394212
23 November 2021 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7351104
14 September 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7312483
10 September 2021 PSC B · COE-Offshore
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7309408
27 February 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7146140
27 February 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7147217
2 October 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7069864
6 March 2020 Administrative Inspection · COE-Administrative
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6921878
25 June 2019 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6721100
20 December 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6600631
2 November 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6299318
26 October 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6295749
25 October 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6294673
25 July 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6219966
26 October 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam · COE-Dockside
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6028420
25 October 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6032590

Deficiency record · 12

07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 27 February 2026 Resolved
Plans and booklets shall be kept up to date, any alterations being recorded thereon as soon as practicable. PSCO observed that the fire control plan for the engine room in way of the purifier flat was inaccurate for these reasons: The fixed foam discharge nozzle located above the purifiers is not connected to a foam firefighting system. It is connected a sea water system. There is no foam tanks for the purifiers but the fire control plan lists one. The CO2 discharge nozzle located on the starboard outboard area of the purifier flat is not marked on the fire control plan. 74SOLAS(97) II-2/20.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 March 2026
Resolution: Received class report attesting to the correction of the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 September 2023 Resolved
11129 -Operational Readiness of Lifesaving Appliances- Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed port and starboard bridge wing quick release life buoys were not attached to the self illuminating light and smoke. Additionally the quick release mechanism was seized in the closed position. 74SOLAS(97)CONS.III/19.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 September 2023
Resolved 18 September 2023
Resolution: PSCO observed quick release pin correctly installed on vessel, vessel has been cleared of the deficiency.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 12 September 2023 Resolved
04114 - Each generator sr shall be capable of automatic starting. PSCO observed emergency diesel generator unable to start under auto mode nor manual mode for approximately 30 minutes. 74 SOLAS (04) II-1/44.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2023
Resolved 14 September 2023
Resolution: Class reported that the Emergency Diesel Generator was tested multiple times and found operable. Class report also states that at the time of inspection the crew did not reset the quick-closing fuel valve before starting the engine, causing false starts.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 September 2023 Resolved
07105 - Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed 01 self-closing door fitted with a hold-back hook leading into the steering gear room. 74 SOLAS (01) II-2/47.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 12 September 2023
Resolved 12 September 2023
Resolution: Vessel removed hold-back arrangement.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 September 2023 Resolved
07105 - Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. PSCO observed broken door frame plate cracked preventing the door to be reasonably gastight. 74 SOLAS (01) II-2/47.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 September 2023
Resolved 12 September 2023
Resolution: Vessel repaired cracked plate allowing the Class A door to close properly.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 September 2023 Resolved
07101 - The use of cylindrical gauge glasses is prohibited. PSCO observed sight glasses of cylindrical type installed onto 03 isolated day tanks. 74 SOLAS (01) II-2/15.2.6.2.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2023
Resolved 14 September 2023
Resolution: Class report submitted, states that the gauges were installed with protective sleeves to prevent any damages.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 September 2023 Resolved
07101 - The termination of sounding pipes are fitted with self-closing blanking devices and with a small diameter self-closing control cock located below the blanking device for the purpose of ascertaining before the blanking device is opened that the fuel oil is not present. PSCO observed 04 self-closing blanks leading to sight glasses seizewd or failing in the open position. 74 SOLAS (01) II-2/15.2.6.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2023
Resolved 14 September 2023
Resolution: Class report stated that the vessel replaced the valve in the Steering gear room and verified operations of valves. all otehrs were verified operational before departing the vessel.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 12 September 2023 Resolved
01309 - Plans shall be kept up to date. PSCO observed a B-15 door listed in the plan beingblocked by a permanently fixed desk preventing use of the door. 74 SOLAS (01) II-2/20.1
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2023
Resolved 14 September 2023
Resolution: Class report stated that the desk was removed and the fire door was no longer being blocked.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 14 March 2023 Resolved
The steering gear compartment shall include gratings or other nonslip surfaces to ensure the suitable working conditions in the event of hydraulic fluid leakage. PSCO observed no grating or other nonslip surface around steering gear. -74SOLAS(04)II-1/29.13.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 September 2023
Resolution: Vessel satisfied requirements during the last PSC Exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2022 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. VESSEL REPORTED A REDUCTION IN PROPULSION WHILE TRANSITING. VESSEL MUST PROVIDE A CLASS REPORT WITH A CAUSAL ANALYSIS OF THE ISSUE AND COMPLETION OF REPAIRS PRIOR TO MOVEMENT.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 28 April 2022
Resolved 28 April 2022
Resolution: Class report recieved stating deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 September 2021 Resolved
For the stowage and care of cylinders. 46 CFR 147.60(b)92) Lockers or housings must be vented to the open air near the top and bottom for poitive ventillation of vapors. Cylinder lockers have been sealed and do not provide adequate ventillation.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 November 2021
Resolution: PSCO's attended vessel, vessel crew removed the welded on steel plating of the door that was covering the ventilation mesh. There is now adequate ventilation to the cylinder locker.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 June 2019 Resolved
The condition of the ship's equipment shall be maintained to conform with the provisons of the present regulations. The starboard side lifeboat showed signs of minor damage as shown by an approximate 30 centimeter crack located at the bottom side of the hull, prot side amidships. SOLAS(2014)I/11.a - 16ac
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 6 March 2020
Resolution: Received satisfactory class report atttesting to repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.