← All vessels
REGAL BAY
REGAL BAY is a 1993 freight ship. The Coast Guard has recorded 29 inspections since 2016, most recently in July 2026, along with 12 deficiencies and 5 operational controls.
Records from 2016 to 2026. Most recent: inspection, 21 July 2026.
- Built
- 1993
- Last inspected
- 21 July 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9053658
C6UG6
385838
Flag
BAHAMAS, THE
Maury page id
psix-385838
Inspections, by type
…with no type recorded9
Years with a record
11 calendar years (2016–2026)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it11323 - Convention (Subpart B), Gross Ton
8653 - Convention (Subpart B), Net Ton
16958 - Displacement, Metric Ton
10520 - Dead Weight, Metric Ton
8653 - Convention (Subpart B), Net Ton
16958 - Displacement, Metric Ton
10520 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 29
21 July 2026
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8443456
17 March 2026
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8327467
27 February 2026
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8314542
24 June 2025
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8152260
14 August 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7980102
12 August 2024
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7979985
18 September 2023
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7791582
12 September 2023
PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7787532
14 March 2023
PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7650477
12 September 2022
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7555351
28 April 2022
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7439708
28 April 2022
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7439823
20 April 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7434138
10 February 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7394212
23 November 2021
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7351104
14 September 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7312483
10 September 2021
PSC B · COE-Offshore
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7309408
27 February 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7146140
27 February 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7147217
2 October 2020
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7069864
6 March 2020
Administrative Inspection · COE-Administrative
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6921878
25 June 2019
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6721100
20 December 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6600631
2 November 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6299318
26 October 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6295749
25 October 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6294673
25 July 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6219966
26 October 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam · COE-Dockside
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6028420
25 October 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6032590
Deficiency record · 12
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 27 February 2026
Resolved
Plans and booklets shall be kept up to date, any alterations being recorded thereon as soon as practicable.
PSCO observed that the fire control plan for the engine room in way of the purifier flat was inaccurate for these reasons: The fixed foam discharge nozzle located above the purifiers is not connected to a foam firefighting system. It is connected a sea water system. There is no foam tanks for the purifiers but the fire control plan lists one. The CO2 discharge nozzle located on the starboard outboard area of the purifier flat is not marked on the fire control plan.
74SOLAS(97) II-2/20.1
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 September 2023
Resolved
11129 -Operational Readiness of Lifesaving Appliances- Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed port and starboard bridge wing quick release life buoys were not attached to the self illuminating light and smoke. Additionally the quick release mechanism was seized in the closed position.
74SOLAS(97)CONS.III/19.2
10c
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 12 September 2023
Resolved
04114 - Each generator sr shall be capable of automatic starting. PSCO observed emergency diesel generator unable to start under auto mode nor manual mode for approximately 30 minutes. 74 SOLAS (04) II-1/44.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 September 2023
Resolved
07105 - Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed 01 self-closing door fitted with a hold-back hook leading into the steering gear room. 74 SOLAS (01) II-2/47.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 September 2023
Resolved
07105 - Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. PSCO observed broken door frame plate cracked preventing the door to be reasonably gastight. 74 SOLAS (01) II-2/47.1
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 September 2023
Resolved
07101 - The use of cylindrical gauge glasses is prohibited. PSCO observed sight glasses of cylindrical type installed onto 03 isolated day tanks. 74 SOLAS (01) II-2/15.2.6.2.2
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 September 2023
Resolved
07101 - The termination of sounding pipes are fitted with self-closing blanking devices and with a small diameter self-closing control cock located below the blanking device for the purpose of ascertaining before the blanking device is opened that the fuel oil is not present. PSCO observed 04 self-closing blanks leading to sight glasses seizewd or failing in the open position. 74 SOLAS (01) II-2/15.2.6.1.3
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 12 September 2023
Resolved
01309 - Plans shall be kept up to date. PSCO observed a B-15 door listed in the plan beingblocked by a permanently fixed desk preventing use of the door. 74 SOLAS (01) II-2/20.1
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 14 March 2023
Resolved
The steering gear compartment shall include gratings or other nonslip surfaces to ensure the suitable working conditions in the event of hydraulic fluid leakage.
PSCO observed no grating or other nonslip surface around steering gear.
-74SOLAS(04)II-1/29.13.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2022
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. VESSEL REPORTED A REDUCTION IN PROPULSION WHILE TRANSITING. VESSEL MUST PROVIDE A CLASS REPORT WITH A CAUSAL ANALYSIS OF THE ISSUE AND COMPLETION OF REPAIRS PRIOR TO MOVEMENT.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 September 2021
Resolved
For the stowage and care of cylinders. 46 CFR 147.60(b)92)
Lockers or housings must be vented to the open air near the top and bottom for poitive ventillation of vapors.
Cylinder lockers have been sealed and do not provide adequate ventillation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 June 2019
Resolved
The condition of the ship's equipment shall be maintained to conform with the provisons of the present regulations. The starboard side lifeboat showed signs of minor damage as shown by an approximate 30 centimeter crack located at the bottom side of the hull, prot side amidships. SOLAS(2014)I/11.a - 16ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.