Records from 1994 to 2010. Most recent: inspection, 10 February 2010.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 14 November 2008
Resolved
Relocate flame failure device for LPG system IAW 46 CFR 184.240, so that the flame failure operates in a reasonable amount of time IAW MFG recommendations for installation on vessel.
Action required: 705 - Other - as specified
Due 14 December 2008
Resolved 24 February 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 November 2008
Resolved
Replace raw water discharge pipe on MDEs port and STBD side.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 14 November 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 November 2008
Resolved
Repair/replace heat exchanger tank on STBD engine.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 14 November 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 November 2008
Resolved
Secure guard on FWD side of MDE (STBD).
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 14 November 2008
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 12 November 2008
Resolved
Secure pilot house chiller pump in STBD E/R FWD.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 14 November 2008
Engineering › Lubricating Oil Service System › Cooler
Issued 12 November 2008
Resolved
Make permanent repairs to port engine oil cooler leak.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 14 November 2008
Documentation › Markings/Placards › Warning Signs
Issued 12 November 2008
Resolved
Provide exit signs in passageway port side Coral Deck, showing proper path of egress.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 14 November 2008
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 12 November 2008
Resolved
Remove multi outlet plug on outlet in STBD generator space.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 14 November 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2008
Resolved
Remove wires from fwd, stbd crew cabin #5.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 14 November 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 November 2008
Resolved
Complete fire and security drills in the presents of a USCG marine inspector.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 14 November 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 12 October 2007
Resolved
Properly mount selector switch on STBD main alternator.
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 22 October 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 12 October 2007
Resolved
Properly mount potable water tank port/STBD side.
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 22 October 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 October 2007
Resolved
Properly condition framing bottom of the ladder in STBD pump room.
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 22 October 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 October 2007
Resolved
Properly run power line to hot water tank STBD side.
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 22 October 2007
Construction/Loadline › Hull › Hull Plating
Issued 20 September 2007
Resolved
Repair as original, waste area approximately 6' by 3' iwo starboard aft strut (forward and inboard).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Resolution: Witnessed "SAT" hose test.
Deck/Cargo › Cargo Stowage › General
Issued 20 September 2007
Resolved
Replace (4) stainless cables to aft dive deck, noted to be worn and fishhooking.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 20 September 2007
Resolved
Secure wire runs in port/starboard thruster rooms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2007
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 20 September 2007
Resolved
Support PVC generator cooling piping overhead in engine rooms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2007
Construction/Loadline › Hull › Hull Plating
Issued 20 September 2007
Resolved
Repair as original wasted area identified iwo port aft inboard strut.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Resolution: Witnessed "SAT" hose testing.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 16 October 2006
Resolved
Multiple corroded side longitudinal stiffeners Port side Pump room.
Due 13 October 2007
Resolved 12 October 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 16 October 2006
Resolved
Door missing on Electrical Box in Port side engine room.
Due 12 December 2006
Resolved 12 December 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 16 October 2006
Resolved
Repair or Replace Electrical lights machinery spaces.
Due 23 October 2006
Resolved 12 December 2006
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 16 October 2006
Resolved
Straps on Life Raft need replacing and Shackle screw Pins need locking Safety Wire.
Due 23 October 2006
Resolved 12 December 2006
Fire Fighting › Grease Extraction Hood › General
Issued 16 October 2006
Resolved
Clean Broiler unit, provide Grease Filters at Range Hood and non-combustible Trash cans.
Due 23 October 2006
Resolved 12 December 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 16 October 2006
Resolved
Repair/replace Propane Leak detector.
Action required: 705 - Other - as specified
Due 23 October 2006
Resolved 16 October 2006
Navigation › Piloting/Steering › Marine Charts
Issued 16 October 2006
Resolved
Navigation Charts for local area outdated.
Due 20 October 2006
Resolved 12 December 2006
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 16 October 2006
Resolved
Compass deviation Table missing.
Due 20 October 2006
Resolved 12 December 2006
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 16 October 2006
Resolved
Chemical test program missing employee assistance program.
Due 20 October 2006
Resolved 23 May 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 October 2006
Resolved
Hydrostatic Release on EPIRB missing clip.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2006
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 18 September 2006
Resolved
Replace wasted/broken fuel shut-off handle in starboard engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 September 2006
Resolved
Replace completely wasted J-box for bilge pump located in starboard engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2006
Construction/Loadline › Hull › Side Shell
Issued 18 September 2006
Resolved
Submit repair proposal for approximately 36" x 24" area of wasted hull plate and associated stiffners iwo outboard shell, aft starboard strut.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2006
Construction/Loadline › Hull › Side Shell
Issued 18 September 2006
Resolved
Provide repair proposal iwo 18" x 18" area marked at fwd/port/inboard hull plate on strut.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2006
Construction/Loadline › Hull › Hull Plating
Issued 18 September 2006
Resolved
Provide repair proposal for wasted hull plate approx. 18" x 18" aft/port/inboard strut.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 September 2006
Resolved
Noted (4) wasted longitudinal stringers in engine room, portside. Repair as original.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2006
Construction/Loadline › Hull › Side Shell
Issued 18 September 2006
Resolved
Found aft strut, port sponson, inboard side wasted and holed approximately 4 feet aft of leading edge. Crop effected area and insert 18X18" repair plate.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2006
Resolved 26 September 2006
Construction/Loadline › Hull › Side Shell
Issued 18 September 2006
Resolved
Found fwd strut, port sponson, inboard side wasted and holed approximately 2 feet fwd of ltrailingedge. Crop effected area and insert 18X18" repair plate.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2006
Resolved 26 September 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 September 2006
Resolved
Found numerous longitudinal frames wasted forward of port propulsion engine beneath starting batteries. Crop and re-new as originally fitted.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2006
Resolved 26 September 2006
Construction/Loadline › Hull › Strut/Cross Tie
Issued 18 September 2006
Resolved
Found two wasted corner bracket clips wasted in port machinery space trunk. Crop and renew as original.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2006
Resolved 26 September 2006
Construction/Loadline › Hull › Stiffener
Issued 18 September 2006
Resolved
Found several wasted longitudinal stiffeners. port machinery space, outboard side, in way of raw water distribution manifold. Crop and renew as original.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2006
Resolved 26 September 2006
Engineering › Bilge Water Management System › Valve
Issued 18 September 2006
Resolved
Replace all fixed bilge piping system check valves.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2006
Resolved 26 September 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 October 2005
Resolved
Provide clear means of access to Remote Fuel Shutoff valve.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2005
Resolved 26 September 2006
Construction/Loadline › Hull › Side Shell
Issued 4 October 2005
Resolved
Obtain thickness measurements of hull plate and internal structural members and transverse bulkheads in way of port and starboard exhaust trunks and provide findings in a written report for evaluation. (46 CFR 176.610)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 13 October 2005
Resolution: Area of concern de-scaled, measured via ultrasonic sounding and deemed to be within acceptable wastage limits. See document list for a copy of written report.
Engineering › Bilge Water Management System › Piping
Issued 4 October 2005
Resolved
Demonstrate proper operation of fixed bilge piping system as directed by the attending marine inspector. (46 CFR 182.500)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 26 September 2006
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 4 October 2005
Resolved
All fuel/hydraulic oil piping systems altered or repaired shall be subject to leak/tightness testing acceptable to the attending marine inspector. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 13 October 2005
Resolution: Witnessed satisfactory air test at approximately 80 psi.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 4 October 2005
Resolved
Found auxiliary black water pump and motor assembly in port machinery space not serviceable and not properly supported. Repair or replace and properly secure. (46 CFR 176.800)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 13 October 2005
Resolution: Pump/motor assembly replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 October 2005
Resolved
Mechanically de-scale, clean and inspect propulsion engine saltwater cooling piping from sea chest connection to flex hose assy, service all sea water strainers and properly mount/secure salt water cooling piping and flex hose assemblies in port and starboard machinery spaces. (46 CFR 176.800)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 13 October 2005
Stability › Watertight Integrity › General
Issued 4 October 2005
Resolved
Re-new all man hole cover assess gaskets disturbed during the course of inspection. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 13 October 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 4 October 2005
Resolved
Install suitable junction box for bilge high level alarm condcutor butt connections in port thruster room. (46 CFR 183.340).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 13 October 2005
Construction/Loadline › Hull › Weld
Issued 4 October 2005
Resolved
Noted several exterior butt and seam welds on hull plate below the water line with eroded weld re-enforcement. Re-weld re-enforcement where measured less than 1/32". (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 13 October 2005
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 26 September 2005
Resolved
Renew both port and starboard main engine shaft packing cooling hoses. Rig hose to route off and away from shafts to prevent chafing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 25 October 2005
Resolution: Noted new hoses installed and fastened, to prevent slippage onto rotating shaft.
Engineering › Fuel Oil Service System › Hose
Issued 26 September 2005
Resolved
Replace or provide cross reference number to show acceptance of main engine fuel oil supply non-metallic flexible hose for both port and Starboard main engines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 25 October 2005
Resolution: Observed new supply and return line fuel hoses installed meeting SAE J 1942.
Lifesaving › Lifejacket/PFD (Type IV) › Retroreflective Material
Issued 26 September 2005
Resolved
Renew reflective tape on all ring bouys/type IV throwable devices.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 25 October 2005
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 26 September 2005
Resolved
Renew line on all ring bouys/Type IV throwable devices with approved bouyant line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 25 October 2005
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 26 September 2005
Resolved
Clean grease build-up from galley hood and develop routine cleaning schedule.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 25 October 2005
Resolution: Observed clean Galley Hood and Check list this date.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 September 2005
Resolved
Install new reflective tape on the two life jackets noted during inspection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 25 October 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 September 2005
Resolved
Properly mark location and method of operation of aft deck emergency fuel pulls for port generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 25 October 2005
Resolution: Noted location and operation properly marked. However, observed that Emer. Shutdowns require moving gangway and lifting carpet for access. Cleared this def. and issued new def. to correct access.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 26 September 2005
Resolved
Renew flexile coupleing on turbo oil return line on both main engines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 25 October 2005
Resolution: Noted new installation.
Construction/Loadline › Hull › Hull Plating
Issued 26 September 2005
Resolved
Submit repair procedures and show attending U.S. Coast Guard Marine Inspector crack/ hole found in port side hull approximetly one frame forward of ladder outboard side IWO where strut meets pontoon.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2005
Resolved 13 October 2005
Resolution: Further investigation of area revealed that the moisture present was a result of internal piping leaks and condensation. The hull plate and associated welds were found to be intact.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 26 September 2005
Resolved
Submit repair procedures for repair of port black water tank and show to attending U.S. Coast Guard Marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2005
Resolved 13 October 2005
Resolution: Tank and piping leaks repaired.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 September 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 23 May 2007
Communications › Radio Communications › EPIRB
Issued 26 September 2005
Resolved
Provide proof of registration for EPIRB from NOAA.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 26 September 2005
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 September 2005
Resolved
Repair aft galley door to close and latch properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 25 October 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 September 2005
Resolved
Post emergency instructions to show proper method and sequence of operation for galley fixed fire suprsssion system. Including ventilation shutdowns.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2005
Resolved 25 October 2005
Electrical › Electric Generation Source (service) › Panelboard
Issued 24 September 2004
Resolved
Missing Breaker in main Breaker Panel. Ensure all breaker slots are properly filled with a breaker or blanked off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electric Generation Source (service) › Panelboard
Issued 24 September 2004
Resolved
Tools and equipment mounted or hanging on electrical panels throughout the machinery spaces. Remove all brackets and repair holes in panels.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 September 2004
Resolved
Improper hoses and plastic piping on cooling system to both port & stbd generator. Hose should be kept to a minimum with double clamps. When hose is use must be in accordance with (IAW) 46CFR182.720. Make permanent and proper repairs.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 September 2004
Resolved
Make proper repairs to electrical outlet outboard starboard main diesel engine (MDE).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electric Generation Source (service) › Panelboard
Issued 24 September 2004
Resolved
Provide proper blanks for the electrical panel forward of the galley.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 24 September 2004
Resolved
Replace fire extinguisher bracket outboard starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 24 September 2004
Resolved
Excessive use of hoses in port & stbd generator exhaust system from apparent past temporary repairs.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Construction/Loadline › Hull › Bottom Plating
Issued 24 September 2004
Resolved
Holes in the deck under Port & Stbd generators, no holes from the machinery space should lead directly to the sea.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 24 September 2004
Resolved
Excessive and improper hoses on fuel oil transfer line to generator day tank. All fuel oil hoses must be no more than 30" and be J-1942 with proper fittings IAW 46CFR182.720.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 September 2004
Resolved
Improper splicing of wire and use of surge protector in storage room fwd of port & stbd generator.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 24 September 2004
Resolved
Black water piping, strainer and hoses not properly mounted or bracketed in port & stbd main machinery space.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Lighting (service) › Lighting Feeder
Issued 24 September 2004
Resolved
Properly mount or remove ballast UV light on the forward starboard generator.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 24 September 2004
Resolved
Prove proper installation of all propane systems IAW American Boat and Yacht Council.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 September 2004
Resolved
Belt Guard stbd & port main wasted and loose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 September 2004
Resolved
Cover to stbd & port stabilizer loose and wires exposed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Construction/Loadline › Hull › Stiffener
Issued 24 September 2004
Resolved
Suspected doublers on port main salt water piping.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Deck/Cargo › Ballast › Piping
Issued 24 September 2004
Resolved
Ballast hoses in port & stbd main machinery spaces laying in bilge and on framing. Properly support and protect from chaffing.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 September 2004
Resolved
Improper hoses to cooling system on port & stbd mains from main to reduction gear. When hose is use must be in accordance with 46CFR182.720.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 24 September 2004
Accommodation/Occupational Safety › Potable Water System › General
Issued 24 September 2004
Resolved
Potable water tanks fwd in stbd & port main machinery space, not properly piped and not secured in place.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 24 September 2004
Resolved
Remove incandescent light forward starboard generator by RO motors.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 24 September 2004
Resolved
Hose between breather and turbo charge on port main not doubled clamped and coated with oil. Fittings and piping to port main turbo charger wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 24 September 2004
Resolved
Hoses and piping to black water tank in port & stbd trunk not properly installed or bracketed. Wire ties cannot be used to support piping or equipment.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Engineering › Bilge Water Management System › Pump
Issued 24 September 2004
Resolved
All aux bilge pumps in trunk, not mounted properly,
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 September 2004
Resolved
Missing Breaker in breaker panel mounted in trunk to port pump room. Ensure all breaker slots are properly filled with a breaker or blanked off.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Engineering › Bilge Water Management System › Valve
Issued 24 September 2004
Resolved
Handles to fire and bilge system in both pump rooms wasted and/or broken.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Engineering › Bilge Water Management System › Pump
Issued 24 September 2004
Resolved
Bilge pump in port pump room not properly mounted, loose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 September 2004
Resolved
Install drip shield as required on all switchboards.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Fire Fighting › Fire Pumps › Arrangement
Issued 24 September 2004
Resolved
Remove hoses from both fire mains and hard properly hard pipe; ensure fire pump is properly mounted.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 24 September 2004
Resolved
Properly label all life saving equipment including SARTS, EPRIB, Life jackets, etc.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 September 2004
Resolved
Repair electrical box cover above sink and galley.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 September 2004
Resolved
Electrical box in generator space loose and not properly mounted.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 September 2004
Resolved
Provide proper cover for electrical panel in galley.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 September 2004
Resolved
Provide locks to power panels accessible to passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 24 September 2004
Resolved
Properly mount and wire sewage transfer pump starboard trunk
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 24 September 2004
Resolved
Prove proper operation of stbd draft indicator system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 24 September 2004
Resolved
Replace corroded fire extinguisher outboard stbd Main Diesel Engine (MDE).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 September 2004
Resolved
Properly mount electrical box and replace box cover pilothouse AC pump.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 September 2004
Resolved
Identify breakers in the electrical panel starboard pump room.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Engineering › Fuel Oil Service System › Tank
Issued 24 September 2004
Resolved
Make proper repairs to broken valve on stbd outboard fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 September 2004
Resolved
Line becketed to life rings with wire ties, properly splice line or replace rings.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 September 2004
Resolved
Replace throw line on port and starboard life ring aft sundeck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 24 September 2004
Resolved
Numerous life jackets failed inspection. Provide proper number of approved adult and children life jackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 September 2004
Resolved
Separate children's life jackets from adults in the sundeck lifejacket locker
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 24 September 2004
Resolved
Mouse all shackles on boat deck.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Navigation › Piloting/Steering › Compass Deviation Table
Issued 24 September 2004
Resolved
Provide compass deviation table.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 September 2004
Resolved
Prove proper operation of second radar.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 24 September 2004
Resolved
Prove proper operation of marine searchlight
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 September 2004
Resolved
Provide proper first aid kit
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 24 September 2004
Documentation › Logs/Records › Logbook (official)
Issued 24 September 2004
Resolved
Provide proper logbook in accordance with 46CFR185.280
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Engineering › Bilge Water Management System › Pump
Issued 24 September 2004
Resolved
Repair and prove proper operation of stbd bilge pump
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2004
Resolved 2 November 2004
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 6 October 2003
Resolved
Properly repair laundry room door to enable closure
Due 10 October 2003
Resolved 6 October 2003
Fire Fighting › Fire Hoses › Material
Issued 6 October 2003
Resolved
Provide approved firefighting hoses to comply with requirements listed in 46 CFR 181.320
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2003
Fire Fighting › Fire Hoses › Connections
Issued 6 October 2003
Resolved
Provide appropriate spanner wrenches for all firefighting hoses
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2003
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 October 2003
Resolved
Replace life ring and lifeline on second deck, port side
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2003
Fire Fighting › Means of Escape
Issued 6 October 2003
Resolved
Ensure all means of escape are readilly apparant
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2003
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 6 October 2003
Resolved
Provide STCW 95 Crowd Management training prior to international voyage.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2003
Construction/Loadline › Structures › Manhole
Issued 6 October 2003
Resolved
Provide adequate closing device and gaskets for forward weathertight hatches
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2003
Engineering › Fuel Oil Service System › Gauge
Issued 6 October 2003
Resolved
Replace broken F/O sight glass on starboard F/O service tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2003
Operations/Management › Dedicated Clean Ballast Tanks › Flushing Pump/Piping System
Issued 6 October 2003
Resolved
Provide properly working ballast control valves
Due 6 October 2003
Resolved 6 October 2003
Personnel › Certificates/Documents/Licenses
Issued 6 October 2003
Resolved
Provide a valid FCC radio certificate
Due 10 October 2003
Resolved 6 October 2003
Engineering › Bilge Water Management System › Pump
Issued 6 October 2003
Resolved
Provide suitible portable bilge pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2003
Communications › Radio Communications
Issued 6 October 2003
Resolved
Provide current FCC operators permit for member of crew LEGACY COMPONENT DESC: FCC operators permit
Due 18 October 2003
Resolved 10 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 6 October 2003
Resolved
Repair rail stantion on stbd midships sundeck
Due 18 October 2003
Resolved 10 October 2003
Accommodation/Occupational Safety › Ventilation
Issued 6 October 2003
Resolved
Provide adequate ventilation for cabin # 18
Condition: Improper Installation
Due 15 November 2003
Resolved 18 November 2003
Fire Fighting › Fire Hoses
Issued 6 October 2003
Resolved
Provide fire hoses that comply with 46CFR 181.320
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2003
Resolved 6 October 2003
Fire Fighting › Fire Hoses › Connections
Issued 6 October 2003
Resolved
Provide properly sized spanner wrench for each fire hose installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2003
Resolved 6 October 2003
Stability
Issued 6 October 2003
Resolved
Provide properly operating draft and ballast tank level gauges I.A.W. stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2003
Lifesaving › Lifebuoys
Issued 6 October 2003
Resolved
Replace life-ring on port sundeck
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2003
Fire Fighting › Fire Main › Pressure
Issued 6 October 2003
Resolved
Demonstrate 60psi F/M pressure at the pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2003
Electrical › Electrical Distribution System (service) › Panelboard
Issued 6 October 2003
Resolved
Provide planks in all electical panels for unused breaker connections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 6 October 2003
Resolved
Provide adequate protection for all light fixtures
Due 18 October 2003
Resolved 18 October 2003
Stability › Weathertight Integrity
Issued 6 October 2003
Resolved
Provide locking device and gaskets for fwd main deck weatherdeck hatches
Due 13 October 2003
Resolved 13 October 2003
Stability
Issued 6 October 2003
Resolved
Provide properly working ballast control valves LEGACY COMPONENT DESC: Ballast control system
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2003
Resolved 7 October 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 6 October 2003
Resolved
Ensure all means of escape are readily apparent
Due 10 October 2003
Resolved 10 October 2003
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 6 October 2003
Resolved
Provide to carriage of passengers on international voyage, provide STCW 95 Croud Management training
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2003
Construction/Loadline › Hull
Issued 28 October 2002
Resolved
Mechanically clean under potable water tanks in port and stbd engine rooms to facilitate inspection. LEGACY COMPONENT DESC: Bottom Plating
Due 1 November 2002
Resolved 31 October 2002
Resolution: Area cleaned and inspected port engine room 2 stiffeners are to be renewed.
Engineering › Bilge Water Management System
Issued 28 October 2002
Resolved
Renew bilge ballast/fire crossover valves in port and stbd pump rooms. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 November 2002
Resolved 31 October 2002
Resolution: Owner renewed bilge ballast/fire crossover valves in port and stbd pump rooms.
Accommodation/Occupational Safety › Potable Water System
Issued 28 October 2002
Resolved
Install correct relief valves in hotwater heaters port and stbd. <100 psi. LEGACY COMPONENT DESC: Relief valves
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 November 2002
Resolved 31 October 2002
Resolution: Correct relief valves installed.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 28 October 2002
Resolved
Make repairs to port and stbd SSDG exhaust piping as identified by Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2002
Resolved 31 October 2002
Resolution: Owner made repairs to port and stbd SSDG exhaust piping as identified by Marine Inspector.
Construction/Loadline › Hull
Issued 28 October 2002
Resolved
Renew stiffener port E/R fwd of engine centerline and 3rd inboard of centerline. LEGACY COMPONENT DESC: Stiffener
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 November 2002
Resolved 31 October 2002
Resolution: Stiffener renewed.
Engineering › Fuel Oil Service System
Issued 2 October 2002
Resolved
Adjust and conduct maintenance of fuel shut off valves and wires. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 8 November 2002
Resolution: Operationally tested remote fuel shut offs. Vsl''s crew installed new cable & pulley system that operated satisfactorily at time of inspection. Inspector cautioned crew on functionality of system if not properly maintained. (greased & exercised)
Engineering › Bilge Water Management System
Issued 2 October 2002
Resolved
Properly secure all auxilliary bilge pumps. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 3 October 2002
Resolved 8 November 2002
Resolution: Witnessed that auxiliary bilge pumps were secured to longitudinal frames located in the ladder wells by one bolt. Though the correction met regulations, workmanship was marginal.
Electrical › Electric Generation Source (service)
Issued 2 October 2002
Resolved
Renew stbd side junction box for fire main pump. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 8 November 2002
Resolution: Witnessed repair of rusted spot on topside of junction box. Plastic patch was secured using 5200 caulking. Though repair met regulations and was functional, it however was of poor quality. Recommended rerouting of piping above box.
Stability › Watertight Integrity
Issued 2 October 2002
Resolved
Renew/provide gaskets for watertight hatches leading to stbd fwd pump room and stbd engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2002
Resolution: Witnessed that gaskets for both hatches had been replaced.
Electrical › Electrical Distribution System (service)
Issued 2 October 2002
Resolved
Remove dead-end cable for old stbd bow thruster. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 8 November 2002
Resolution: Witnessed that removal of old bow thruster dead-end cable had been completed
Engineering › Bilge Water Management System
Issued 2 October 2002
Resolved
Renew or remove bilge pump in stbd bow thruster room. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 16 October 2003
Fire Fighting › Fire Pumps
Issued 2 October 2002
Resolved
Service firepump overboard discharge valve.
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 31 October 2002
Resolution: Item renewed.
Fire Fighting › Structural Fire Protection - General
Issued 2 October 2002
Resolved
Renew structural fire protection (insulation) in overhead in laundry room and machinery space. LEGACY COMPONENT DESC: Structural Bulkhead Construction
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 31 October 2002
Resolution: Insulation installed.
Fire Fighting › Fire Main
Issued 2 October 2002
Resolved
Renew gasket in flange for fire main in port pump room. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 31 October 2002
Resolution: Gasket renewed.
Electrical › Lighting (service)
Issued 2 October 2002
Resolved
Provide guard on globe (light fixture) in ladder trunk leading to port pump room. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 8 November 2002
Resolution: Witnessed that guard had been installed on lighting fixture.
Stability › Watertight Integrity
Issued 2 October 2002
Resolved
Provide packing for wires running through watertight bulkhead deck leading to port pump room and bow thruster space IWO scuttles.
Condition: Improper Installation
Due 3 November 2002
Resolved 8 November 2002
Resolution: Approved fire-stop caulking was used for packing. Determined that packing marginally met requirement and workmanship was below average. Crew was instructed to apply additional coats of packing in thin areas and especially underneath.
Electrical › Electrical Distribution System (service)
Issued 2 October 2002
Resolved
Properly deadend cmmunications cable in port bow thruster room. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 8 November 2002
Resolution: All wiring which was required to be deadended was observed to be removed.
Electrical › Electrical Distribution System (service)
Issued 2 October 2002
Resolved
Repair wiring to hot water heater at junction box. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 16 October 2003
Electrical › Electrical Distribution System (service)
Issued 2 October 2002
Resolved
Remove extension-cord and replace with approved permenant cable and fixtures in stbd generator space. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 3 November 2002
Resolved 8 November 2002
Resolution: Observed that new wiring had been installed and extension cord had been removed.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 October 2002
Resolved
Renew lagging on stbd generator, port engine. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 8 November 2002
Resolution: Observed that new lagging had been installed on both starboard generator and port engine exhaust.
Electrical › Electrical Distribution System (service)
Issued 2 October 2002
Resolved
Provide cover for junction box on stbd vent fan.
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 8 November 2002
Resolution: New cover was installed for starboard-side vent fan junction box.
Electrical › Electrical Distribution System (service)
Issued 2 October 2002
Resolved
Remove wireties (plastic) and replace with metal clips throughout vessel.
Condition: Improper Installation
Due 3 November 2002
Resolved 16 October 2003
Engineering › Shafting/Propeller Arrangements
Issued 2 October 2002
Resolved
Replace cooling hose going to both port and stbd stuffing box. LEGACY COMPONENT DESC: Stern Tube Bearing
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 8 November 2002
Resolution: Witnessed replacment of cooling hoses for both stuffing boxes. However crew was advised of the benefits in shortening the length of
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 2 October 2002
Resolved
Repair exhaust leak on stbd engine. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 8 November 2002
Resolution: Replaced exhaust riser. No further leaking was observed.
Construction/Loadline › Penetrations
Issued 2 October 2002
Resolved
Repair hole IWO scuttle leading to stbd engine room.
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 8 November 2002
Resolution: Hole which was drilled in order to allow water to drain from beneath the stbd generator was marginally repaired by the use of caulk for plugging.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 2 October 2002
Resolved
Provide proper mount for fire extinghuishers in laudry room and engine control room. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Due 3 November 2002
Resolved 8 November 2002
Resolution: All fire extingushers were observed to be properly mounted.
Electrical › Electrical Distribution System (service)
Issued 2 October 2002
Resolved
Provide non-conductive matting IWO main switchboard. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Due 3 November 2002
Resolved 8 November 2002
Resolution: Observed non-conductive mat at main switchboard.
Electrical › Electrical Distribution System (service)
Issued 2 October 2002
Resolved
Provide blanks for open slots in main switchoard. LEGACY COMPONENT DESC: Switchboard
Condition: Improper Installation
Due 3 November 2002
Resolved 16 October 2003
Fire Fighting › Combustible Materials
Issued 2 October 2002
Resolved
Remove oil from underneath port generator.
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 31 October 2002
Resolution: oil removed.
Engineering
Issued 2 October 2002
Resolved
Secure both port and stbd sanitation pumps.
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 16 October 2003
Electrical › Electrical Distribution System (service)
Issued 2 October 2002
Resolved
Provide switchcover for aux bilge pump in port engine room. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 16 October 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 2 October 2002
Resolved
Renew fire extinguisher bracket in port engine room. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Due 3 November 2002
Resolved 8 November 2002
Resolution: New fire extinguisher bracket for port engineroom was observed.
Electrical › Electrical Distribution System (service)
Issued 2 October 2002
Resolved
Secure junction boxes IWO both port and starboard shafts.
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 8 November 2002
Resolution: Junction boxes were observed to be secured by means of plastic zip tie. Though the boxes were secure, the means by which this was accomplished is only temporary. Crew was advised that a more permanent fastener should be provided.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 2 October 2002
Resolved
Renew raw water pipe IWO exhaust on port engine. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 16 October 2003
Engineering › Lubricating Oil Service System
Issued 2 October 2002
Resolved
Secure lube oil transfer pump. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 16 October 2003
Electrical › Lighting (service)
Issued 2 October 2002
Resolved
Provide light fixture cover over port engine. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 16 October 2003
Engineering › Fuel Oil Service System
Issued 2 October 2002
Resolved
Renew fuel lines port and stbd generator with approved hose. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 3 November 2002
Resolved 16 October 2003
Communications › Internal Communications System
Issued 2 October 2002
Resolved
Ensure the PA system is operating properly.
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 31 October 2002
Resolution: Item repaired
Electrical › Lighting (emergency)
Issued 2 October 2002
Resolved
Repair emergency lighting system.
Condition: Improper/Lack of Maintenance
Due 3 November 2002
Resolved 16 October 2003
Engineering
Issued 25 October 2001
Resolved
Properly clean and stow gear in engine room spaces to allow for proper inspection.
Condition: Unknown
Due 29 October 2001
Resolved 29 October 2001
Electrical
Issued 25 October 2001
Resolved
Repair/Replace necessary fuel hoses for ship.
Condition: Unknown
Due 29 January 2002
Resolved 29 January 2002
Accommodation/Occupational Safety
Issued 25 October 2001
Resolved
Label escape hatch on stbd. side.
Condition: Unknown
Due 4 November 2001
Resolved 29 January 2002
Engineering
Issued 25 October 2001
Resolved
Provide Machinery guards for M/E Alternators.
Condition: Unknown
Due 9 November 2001
Resolved 29 October 2001
Electrical
Issued 25 October 2001
Resolved
Repair/Replace STBD generator governor.
Condition: Unknown
Due 4 November 2001
Resolved 29 October 2001
Electrical
Issued 25 October 2001
Resolved
Investigate and repair oil leak on starboard generator.
Condition: Unknown
Due 18 December 2001
Resolved 29 October 2001
Engineering
Issued 25 October 2001
Resolved
Install lagging on all exhaust systems.
Condition: Unknown
Due 4 November 2001
Resolved 29 October 2001
Engineering
Issued 25 October 2001
Resolved
Locate and repair water leak over port main exhaust.
Condition: Unknown
Due 18 December 2001
Resolved 29 October 2001
Engineering
Issued 25 October 2001
Resolved
Repair/Replace fuel transfer control valves stbd. engine room & pumps.
Condition: Unknown
Due 4 November 2001
Resolved 29 October 2001
Deck/Cargo
Issued 25 October 2001
Resolved
Replace capstan handle and demostrate capstan function.
Condition: Unknown
Due 4 November 2001
Resolved 29 October 2001
Electrical
Issued 25 October 2001
Resolved
Provide light cover for light in photolab/E6 room.
Condition: Unknown
Due 4 November 2001
Resolved 29 October 2001
Accommodation/Occupational Safety
Issued 25 October 2001
Resolved
Demonstrate proper operation of propane shutoff for galley stove prior to departure.
Condition: Unknown
Due 29 January 2002
Resolved 29 January 2002
Construction/Loadline
Issued 25 October 2001
Resolved
Provide latches/securing device for both forward hatches.
Condition: Unknown
Due 4 November 2001
Resolved 29 January 2002
Accommodation/Occupational Safety
Issued 25 October 2001
Resolved
Provide and secure guard rail on forward deck.
Condition: Unknown
Due 4 November 2001
Resolved 29 January 2002
Engineering
Issued 25 October 2001
Resolved
Repair/Replace DAHL valves filters.
Condition: Unknown
Due 4 November 2001
Resolved 29 October 2001
Accommodation/Occupational Safety
Issued 25 October 2001
Resolved
Provide netting for 2 dive deck beams.
Condition: Unknown
Due 4 November 2001
Resolved 29 January 2002
Engineering
Issued 25 October 2001
Resolved
Replace/Clean engine room exhaust screens & clean all electric motors.
Condition: Unknown
Due 4 November 2001
Resolved 29 October 2001
Engineering
Issued 25 October 2001
Resolved
Repair fuel leak on port engine main return line.
Condition: Unknown
Due 4 November 2001
Resolved 29 October 2001
Engineering
Issued 25 October 2001
Resolved
Repair leak on stuffing box for port shaft.
Condition: Unknown
Due 4 November 2001
Resolved 29 October 2001
Engineering
Issued 25 October 2001
Resolved
Provide means for emergency shut off valve for stbd tank.
Condition: Unknown
Due 4 November 2001
Resolved 29 October 2001
Electrical
Issued 25 October 2001
Resolved
Investigate and repair port generator hunting condition.
Condition: Unknown
Due 4 November 2001
Resolved 29 October 2001
Construction/Loadline
Issued 25 October 2001
Resolved
Demonstrate proper operation of bilge system and label valves prior to departure.
Condition: Unknown
Due 18 January 2002
Resolved 18 January 2002
Lifesaving
Issued 25 October 2001
Resolved
Conduct man overboard and fire drills prior to departure.
Condition: Unknown
Due 29 October 2001
Resolved 29 October 2001
Construction/Loadline
Issued 25 October 2001
Resolved
Test vessel's high level alarms for bilge.
Condition: Unknown
Due 18 January 2002
Resolved 18 January 2002
Documentation
Issued 25 October 2001
Resolved
Within 90 days provide documentation of implementation of SMS system onboard the vessel and company.
Condition: Unknown
Due 11 December 2001
Resolved 11 December 2001
Resolution: Received and accepted SMS audit and correction of non conformities.
Lifesaving
Issued 23 October 2000
Resolved
Provide emergency escape placards on the inside of all passenger cabins
Condition: Unknown
Due 26 October 2000
Resolved 2 November 2000
Engineering
Issued 23 October 2000
Resolved
Renew damaged exhaust insulation on port MDE
Condition: Unknown
Due 26 October 2000
Resolved 2 November 2000
Lifesaving
Issued 23 October 2000
Resolved
Provide Solas Training Manual
Condition: Unknown
Due 26 October 2009
Resolved 2 November 2000
Navigation
Issued 23 October 2000
Resolved
Compass diviation table outdated
Condition: Unknown
Due 26 October 2000
Resolved 2 November 2000
Documentation
Issued 8 January 1998
Resolved
Comply with 46 CFR Part 16 Drug Testing Program.
Condition: Unknown
Due 8 February 1998
Resolved 5 February 1998
Fire Fighting
Issued 17 January 1997
Resolved
PROPERLY SERVICE FIXED EXTINGUISHING SYSTEM FOR THE GALLEY RANGE HOOD; PROVIDE SERVICING CERTIFICATE.
Condition: Unknown
Due 22 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 12 January 1996
Resolved
SERVICE ONE B-II FIRE EXT.
Condition: Unknown
Due 19 January 1996
Resolved 7 February 1996
Construction/Loadline
Issued 8 January 1996
Resolved
Provide new handle for port e/r #1 a/c chiller valve.
Condition: Unknown
Due 12 January 1996
Resolved 18 January 1996
Fire Fighting
Issued 8 January 1996
Resolved
Replace fire extinguishers located in port & stbd e/r.
Condition: Unknown
Due 12 January 1996
Resolved 18 January 1996
Fire Fighting
Issued 11 March 1994
Resolved
PROVIDE PROPER FIRESTATION BOX IN 02 DECK CORRIDOR.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Electrical
Issued 11 March 1994
Resolved
PROVIDE MISSING INTERIOR SAFETY PANELS IN LARGE ELECTRICAL DISTRIBUTION PANELS IN PUMPROOM TRUNKS.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Electrical
Issued 11 March 1994
Resolved
RAISE UP DIESEL START BATTERIES FROM LOCATION IN BILGE.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Accommodation/Occupational Safety
Issued 11 March 1994
Resolved
INCREASE RAILING HEIGHT TO 42 INCHES FWD OF THE LIFERAFTS.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Accommodation/Occupational Safety
Issued 11 March 1994
Resolved
SECURE HOT TUB TO DECK
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Lifesaving
Issued 11 March 1994
Resolved
PROVIDE ONE ADDITIONAL CHILD SIZE LIFEJACKET. VESSEL RESTRICTED TO 5 CHILDREN UNTIL COMPLIANCE.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Documentation
Issued 11 March 1994
Resolved
PROVIDE ORIGIONAL STABILITY LTR ABOARD VESSEL AND POST ON BRIDGE.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Accommodation/Occupational Safety
Issued 5 March 1994
Resolved
DEMONSTRATE PROPER OPERATION OF HIGH PRESSURE SCBA FILL COMPRESSORS.
Condition: Unknown
Due 5 March 1994
Resolved 5 March 1994
Construction/Loadline
Issued 5 March 1994
Resolved
DEMONSTRATE PROPER OPERATION OF 4 POINT FATHOMETER SYSTEM (FORE & AFT EACH PONTOON).
Condition: Unknown
Due 5 March 1994
Resolved 5 March 1994
Lifesaving
Issued 5 March 1994
Resolved
STENCIL PFD STOWAGE IN ACCORDANCE WITH 46 CFR 185.30-10.
Condition: Unknown
Due 5 March 1994
Resolved 5 March 1994
Accommodation/Occupational Safety
Issued 5 March 1994
Resolved
INSTALL GUARDS ON ENGINEROOM VENT SUPPLY FAN PULLEYS, PORT & STBD.
Condition: Unknown
Due 5 March 1994
Resolved 5 March 1994
Documentation
Issued 5 March 1994
Resolved
PROVIDE VALID STABILITY LETTER ON BOARD PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 March 1994
Resolved 5 March 1994
Documentation
Issued 5 March 1994
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION ON BOARD PRIOR TO CARRYING PASSENGERS. (VERIFIED PENDING ISSUANCE WITH MIAVD, DOC NOT ONBOARD).
Condition: Unknown
Due 5 March 1994
Resolved 5 March 1994
Documentation
Issued 5 March 1994
Resolved
PROVIDE VALID FCC CERTIFICATES ON BOARD PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 5 March 1994
Resolved 5 March 1994
Navigation
Issued 5 March 1994
Resolved
PROVIDE COMPASS DEVIATION TABLE FOR 2 MAGNETIC COMPASSES.
Condition: Unknown
Due 5 March 1994
Resolved 5 March 1994