Records from 2007 to 2026. Most recent: inspection, 5 June 2026.
Inspection history · 56
5 June 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8401085
13 May 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8372615
7 April 2026
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8343991
28 October 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8260117
12 August 2025
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8208943
28 May 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8148064
5 April 2025
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8109297
10 March 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8094952
8 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8060028
23 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8039380
14 November 2024
Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8034774
19 July 2024
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7963870
26 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7947985
27 March 2024
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7885596
24 May 2023
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7689159
5 May 2023
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7681851
14 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7668857
4 April 2023
Deficiency Check · Excursion Permit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7662885
9 March 2023
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7641358
29 November 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7601401
17 October 2022
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7580452
3 October 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7570930
22 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7416574
16 March 2022
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7412682
3 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7405267
30 August 2021
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7300616
10 August 2021
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7282375
1 April 2021
MTSA Verification · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7166719
7 October 2020
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7073447
1 October 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7096640
8 April 2020
Administrative Inspection · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7038605
20 January 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6894793
15 December 2019
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6874603
10 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6832276
16 September 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6838738
10 September 2019
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6876417
19 August 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6789474
28 March 2019
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6651876
11 March 2019
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6639978
7 March 2019
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6639897
11 September 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6574819
1 August 2018
Administrative Inspection · Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6499687
6 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6469425
11 June 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6441000
23 May 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6421712
20 April 2018
Excursion Permit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6395420
12 March 2018
COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6370051
2 October 2017
Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6285855
29 May 2017
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6161066
29 May 2017
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6168656
18 May 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6149624
28 March 2017
Excursion Permit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6112875
6 March 2017
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6100262
22 October 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6033916
25 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5861935
17 March 2016
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5841833
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2026
Resolved
All electrical installations shall be made to the satisfaction of the OCMI. The battery cables in way of the main engines and generator start batteries is welding cable. Replace the same or prove compliance with the cable requirements in Part 183. Cite: 46 CFR 183.01-15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2026
Resolved 13 May 2026
Resolution: POC attested to replacement of all welding cable on start batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2026
Resolved
All electrical installations shall be made to the satisfaction of the [name withheld] "B" is showing a ground on the first LED; Bus "C" is showing a ground on the third LED of Bus "C". Trace grounds and make repairs. Cite: 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2026
Resolved 29 June 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 March 2024
Resolved
Vessel Class 3 watertight doors are in need of adjustment as they are not sealing properly and are allowing daylight through, questioning their watertight integrity. Make adjustments to doors and test to OCMI satisfaction.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 March 2024
Resolution: Crew made adjustments and tested to OCMI satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 March 2024
Resolved
The lifefloat float-free link and painter assembly was found installed so that the breaking strength operation is hindered. Install the float-free assembly system so that breaking operation is not obstructed, to OCMI satisfaction.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 March 2024
Resolution: Crew installed properly to not obstruct break-free operation of lifefloat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 May 2023
Resolved
Vessel was underway with passengers and noticed their starboard generator start to bog down, troubleshoot issues with the generator to prove full operation prior to getting underway with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2023
Resolved 5 May 2023
Resolution: Dirty fuel filter was removed, sea trials conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 1 April 2021
Resolved
02 Emergency lighting fixtures in the "Up/Down" stairs near galley are extinguished. Repair both lights to the satisfaction of the attending Marine Inspector. 46 CFR 120.432
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2021
Resolution: Replaced batteries in both units, test all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2020
Resolved
Must complete in person inspection and drills within 90 days. Delayed due to COVID-19 and lack of availble crew.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 July 2020
Resolved 24 September 2020
Resolution: Completed Annual Inspection
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 April 2020
Resolved
Adjust WTD to ensure proper closure and perform Chalk Testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2020
Resolved 29 October 2020
Resolution: adjusted WTD, Chalk tested for verification. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 September 2019
Resolved
Return the vessels forward Main Vertical Zone 3rd deck port side to it's original Coast Guard approved plans SFP drawing number 07000-2 MSC approved September 25, 1992 and D & L Dwg 92-402-3510 Alt O, and MSC letter Serial Number H2-1803044 dated August 6, 2018
Action required: 705 - Other - as specified
Due 17 January 2020
Resolved 1 July 2020
Resolution: door constructed to meet new plans/drawing, Serial: H2-2001785.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 August 2019
Resolved
Remove all Fire Load from the third deck port forward life jacket storage locker, and insulate underside of stairs to A-60 as a temporary measure for the forward main vertical zone(MVZ)
Action required: 705 - Other - as specified
Due 16 September 2019
Resolved 16 September 2019
Resolution: Installed insulation and removed fire load from space. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 March 2019
Resolved
Complete but simple instructions with a schematic diagram must be included for protected spces that store CO2 cylinders in a different space. At or near each pull box and stop valve control. Engine Room and Bowthruster Room CO2 cylinder system pull boxes and stop valve controls do not have schematic diagrams present. Install schematic diagram and controll stations to the satisfaction of attending Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 28 March 2019
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 7 March 2019
Resolved
Special rules pertaining to vessels carrying passengers for stability. The starboard side forward goose neck vent for the potable water system is missing its ball check and could affect stability of vessel. Repair/replace goose neck vent ball check to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2019
Resolved 28 March 2019
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 11 June 2018
Resolved
Coolant seeping out from keel cooler. Provide repair plan and conduct repairs: 46 CFR 2.02
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2018
Resolved 13 June 2018
Resolution: Welded fractured. no leaks
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 12 March 2018
Resolved
Re-Installl missing and damaged structural fire protection insulation (A-60) in the following areas per Coast Guard approved plan dated Jul 11, 1992/MSC letter serial number H2-20851: 1. Aft bulkhead 3rd deck. 2. Underside of stairs 3rd deck starboard aft. 3. Port forward stair underside, and life jacket storage locker 3rd deck port forward. 4. Stair tower leading to hold from main deck including underside of stairs per 46 CFR 177.10-1, 46 CFR 116.415 and 46 CFR 116.438
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 10 October 2019
Resolution: Converted to new CG-835 see MISLE act.6789474