← All vessels
ODYSSEY LAKE MICHIGAN
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Great Lakes District (CGD-GL) · Other hulls named ODYSSEY LAKE MICHIGAN
ODYSSEY LAKE MICHIGAN is a 1993 passenger vessel (inspected). The Coast Guard has recorded 145 inspections since 1993, most recently in June 2026, along with 153 deficiencies and 8 casualty investigations between 2007 and 2019.
Records from 1993 to 2026. Most recent: inspection, 5 June 2026.
- Built
- 1993
- Last inspected
- 5 June 2026
- Documentation
- Case Pending · documentation file of 10 September 2026
- Inspections
- 145
- Deficiencies
- 153 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 8 investigations · 2007–2019
Identity
991413
WBU4276
386006
Flag
UNITED STATES
367360260
Maury page id
psix-386006
Inspections, by type
…with no type recorded17
Years with a record
32 calendar years (1993–2026)
The 145 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)162.5 ft × 40.0 ft × 13.5 ft
Registered tonnagegross 88 / net 60
ITC dimensions (L × B × D)162.5 ft × 40.0 ft × 13.5 ft
ITC tonnagegross 1,611 / net 500
BuilderSERVICE MARINE INDUSTRIES INC · MORGAN CITY, LA, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1611 - Convention (Subpart B), Gross Ton
88 - Regulatory (Subpart C or D), Gross Ton
500 - Convention (Subpart B), Net Ton
60 - Regulatory (Subpart C or D), Net Ton
88 - Regulatory (Subpart C or D), Gross Ton
500 - Convention (Subpart B), Net Ton
60 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WBU4276MMSI 367360260 · active · compulsorily equipped · granted 3 July 2018, expires 3 June 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 145
5 June 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8401085
13 May 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8372615
7 April 2026
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8343991
28 October 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8260117
12 August 2025
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8208943
28 May 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8148064
5 April 2025
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8109297
10 March 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8094952
8 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8060028
23 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8039380
14 November 2024
Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8034774
19 July 2024
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7963870
26 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7947985
27 March 2024
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7885596
24 May 2023
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7689159
5 May 2023
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7681851
14 April 2023
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7668857
4 April 2023
Deficiency Check · Excursion Permit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7662885
9 March 2023
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7641358
29 November 2022
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7601401
17 October 2022
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7580452
3 October 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7570930
22 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7416574
16 March 2022
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7412682
3 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7405267
30 August 2021
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7300616
10 August 2021
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7282375
1 April 2021
MTSA Verification · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7166719
7 October 2020
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7073447
1 October 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7096640
8 April 2020
Administrative Inspection · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7038605
20 January 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6894793
15 December 2019
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6874603
10 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6832276
16 September 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6838738
10 September 2019
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6876417
19 August 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6789474
28 March 2019
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6651876
11 March 2019
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6639978
7 March 2019
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6639897
11 September 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6574819
1 August 2018
Administrative Inspection · Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6499687
6 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6469425
11 June 2018
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6441000
23 May 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6421712
20 April 2018
Excursion Permit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6395420
12 March 2018
COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6370051
2 October 2017
Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6285855
29 May 2017
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6161066
29 May 2017
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6168656
18 May 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6149624
28 March 2017
Excursion Permit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6112875
6 March 2017
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6100262
22 October 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6033916
25 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5861935
17 March 2016
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5841833
21 October 2015
Excursion Permit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5748100
16 May 2012
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4313268
8 May 2012
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4305287
3 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4301882
23 February 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4250503
22 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4248682
7 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4239823
22 August 2011
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4123642
26 July 2011
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4095060
24 January 2011
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3931743
14 January 2011
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3926692
19 February 2010
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3682401
17 April 2009
Excursion Permit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3454621
8 April 2009
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3448843
23 March 2009
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3434930
8 December 2008
Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3376060
23 October 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3350140
9 June 2008
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3231673
6 June 2008
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3229044
21 May 2008
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3213354
14 April 2008
Excursion Permit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3184133
27 March 2008
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3159015
24 January 2008
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3135830
3 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3124023
30 October 2007
Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3089970
13 September 2007
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3056596
20 July 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3035343
18 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2934201
12 May 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2947507
10 May 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2946267
3 May 2007
Excursion Permit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2921426
21 February 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2876471
9 February 2007
Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2869486
8 February 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2870997
1 February 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2865631
25 January 2007
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2861800
23 January 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2864687
3 May 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2639848
10 April 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2620793
4 April 2006
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2616795
23 February 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2591057
23 February 2006
Inclining Experiment
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2598893
24 January 2006
Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2572569
15 August 2005
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2464205
21 July 2005
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2455712
7 July 2005
Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2410421
11 April 2005
Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2331087
27 August 2004
Deficiency Check · MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2178467
23 June 2004
MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2088796
10 May 2004
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2063671
28 April 2004
Excursion Permit
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2054564
14 April 2004
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2042315
10 March 2004
In-Service Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2023347
16 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971015
28 January 2003
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1736312
18 November 2002
Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1706872
27 February 2002
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1481858
14 August 2001
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1069451
26 March 2001
Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1426560
2 February 2001
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1468624
30 April 2000
Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1423362
28 January 2000
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1391208
14 September 1999
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 109634
24 June 1999
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1190697
24 June 1999
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1471200
17 May 1999
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 796113
29 March 1999
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1113938
5 March 1999
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 801012
27 August 1998
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 141738
11 August 1998
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 105177
23 March 1998
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1402646
12 November 1997
Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 786115
15 September 1997
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1122196
28 January 1997
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1469478
2 February 1996
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1078134
2 February 1996
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1405852
23 March 1995
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1162878
7 February 1995
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1425552
11 May 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 133845
29 March 1994
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 857412
7 February 1994
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1442100
18 June 1993
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1134008
11 June 1993
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 692385
24 May 1993
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 828266
19 May 1993
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 157281
13 May 1993
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 102347
3 May 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1142834
7 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1142833
7 April 1993
Initial Certification · Initial Construction-Excluding Oversight · Inclining Experiment · Plan Review "T" Boat · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420741
Deficiency record · 153
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2026
Resolved
All electrical installations shall be made to the satisfaction of the OCMI. The battery cables in way of the main engines and generator start batteries is welding cable. Replace the same or prove compliance with the cable requirements in Part 183. Cite: 46 CFR 183.01-15
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2026
Resolved
All electrical installations shall be made to the satisfaction of the [name withheld] "B" is showing a ground on the first LED; Bus "C" is showing a ground on the third LED of Bus "C". Trace grounds and make repairs. Cite: 46 CFR 183.01-15
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 March 2024
Resolved
Vessel Class 3 watertight doors are in need of adjustment as they are not sealing properly and are allowing daylight through, questioning their watertight integrity. Make adjustments to doors and test to OCMI satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 March 2024
Resolved
The lifefloat float-free link and painter assembly was found installed so that the breaking strength operation is hindered. Install the float-free assembly system so that breaking operation is not obstructed, to OCMI satisfaction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 May 2023
Resolved
Vessel was underway with passengers and noticed their starboard generator start to bog down, troubleshoot issues with the generator to prove full operation prior to getting underway with passengers.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 1 April 2021
Resolved
02 Emergency lighting fixtures in the "Up/Down" stairs near galley are extinguished. Repair both lights to the satisfaction of the attending Marine Inspector. 46 CFR 120.432
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2020
Resolved
Must complete in person inspection and drills within 90 days. Delayed due to COVID-19 and lack of availble crew.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 April 2020
Resolved
Adjust WTD to ensure proper closure and perform Chalk Testing.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 September 2019
Resolved
Return the vessels forward Main Vertical Zone 3rd deck port side to it's original Coast Guard approved plans SFP drawing number 07000-2 MSC approved September 25, 1992 and D & L Dwg 92-402-3510 Alt O, and MSC letter Serial Number H2-1803044 dated August 6, 2018
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 August 2019
Resolved
Remove all Fire Load from the third deck port forward life jacket storage locker, and insulate underside of stairs to A-60 as a temporary measure for the forward main vertical zone(MVZ)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 March 2019
Resolved
Complete but simple instructions with a schematic diagram must be included for protected spces that store CO2 cylinders in a different space. At or near each pull box and stop valve control. Engine Room and Bowthruster Room CO2 cylinder system pull boxes and stop valve controls do not have schematic diagrams present. Install schematic diagram and controll stations to the satisfaction of attending Marine Inspector
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 7 March 2019
Resolved
Special rules pertaining to vessels carrying passengers for stability. The starboard side forward goose neck vent for the potable water system is missing its ball check and could affect stability of vessel. Repair/replace goose neck vent ball check to the satisfaction of attending Marine Inspector.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 11 June 2018
Resolved
Coolant seeping out from keel cooler. Provide repair plan and conduct repairs: 46 CFR 2.02
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 12 March 2018
Resolved
Re-Installl missing and damaged structural fire protection insulation (A-60) in the following areas per Coast Guard approved plan dated Jul 11, 1992/MSC letter serial number H2-20851: 1. Aft bulkhead 3rd deck. 2. Underside of stairs 3rd deck starboard aft. 3. Port forward stair underside, and life jacket storage locker 3rd deck port forward. 4. Stair tower leading to hold from main deck including underside of stairs per 46 CFR 177.10-1, 46 CFR 116.415 and 46 CFR 116.438
Lifesaving › Inflatable Liferafts › Not on Board
Issued 3 May 2012
Resolved
Vessel is limited to carrying no more than 644 total persons until an additional 100 person IBA or liferaft is placed on board. Vessel is restricted to within 3 miles from shore.
Engineering › Diesel Engine (propulsion-direct drive) › Air Silencer
Issued 23 February 2012
Resolved
Fwd clamp for air cleaner on port eng is missing and needs replaced.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 23 February 2012
Resolved
Handle for walk in produce cooler missing and required to be replaced.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 February 2012
Resolved
Epirb is being serviced and not on board. reduced to 404 person o/b and route inside chicago breakwall.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 26 July 2011
Resolved
Post approved fire control plans
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 March 2009
Resolved
Properly maintain all wiring with metal supports per 46 CFR 120.340 (a)(4) (Every 24")
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 March 2009
Resolved
Replace (E) light installation on 02 deck above bar (service station) per 46CFR115.830.
Communications › Radio Communications › EPIRB
Issued 23 March 2009
Resolved
Replace EPIRB hydrastic release per 46 CFR 117.64 by 23 APR 09
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 6 June 2008
Resolved
Prior to operating all cooking appliances service by th Ansul system in the galley provide proof of servicing and recharging per 46 CFR 118.400.
Engineering › Lubricating Oil Service System › Gauge
Issued 27 March 2008
Resolved
Repair/replace guage at op station indicating bow thruster gear oil pressure.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 March 2008
Resolved
Provide/install plugs for bulkhead, aft of galley, Topaz deck iwo threaded holes above doorway.
Stability › Watertight Integrity › General
Issued 27 March 2008
Resolved
Assess rudder post packing nuts and ensure they are properly placed in service iaw 46 CFR 115.610.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 March 2008
Resolved
Clear egress route to bow mooring/lifesaving station iaw 46 cfr 116.510.
Stability › Unintentional Flooding › General
Issued 27 March 2008
Resolved
Replace bilge strainer, chiller space void. Demonstrate proper operations (speed of dewatering questionable).
Engineering › Bilge Water Management System › Interface Detector
Issued 5 November 2007
Resolved
Install a high-level bilge alarm in the transducer space void. alarm shall include a visual and audible indicator at the operating station. 46 CFR 119.530
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 8 February 2007
Resolved
Renew all broken outlet covers located throughout vessel
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 February 2007
Resolved
Properly terminate dead-end wires located in the galley under the scullery and in the second deck aft bus station.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 February 2007
Resolved
Renew junction boxes located behind the scullery and behind the grill. The junction box behind the scullery was coated in silicone to prevent water intrusion. Recommended that the junction box be moved to a dryer location.
Electrical › Electrical Distribution System (service) › Switch
Issued 8 February 2007
Resolved
Ensure all motor controllers are properly marked IAW 46CFR120.220(d).
Operations/Management › Equipment Service/Testing › EPIRB
Issued 8 February 2007
Resolved
Provide proof of properly installed 406 Epirb IAW 46CFR117.205(d) prior to carrying passengers more than 3nm from shore.
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 8 February 2007
Resolved
Prove proper operation of installed sprinkler system.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 8 February 2007
Resolved
Renew engine room ventilation closure device as required by 46CFR119.465(h).
Lifesaving › Liferaft Equipment › Paddle
Issued 8 February 2007
Resolved
Mark paddles with vessel name IAW 46CFR122.604(g) and lash to the life float IAW 46CFR117.175(f)(2)
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 February 2007
Resolved
Ensure all circuit breaker panels are properly marked IAW 46CFR120.220(d)
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 February 2007
Resolved
Prior to carrying passengers underway, conduct sea trials to the satisfaction of an attending CG Marine inspector.
Stability › Weathertight Integrity › General
Issued 8 February 2007
Resolved
Renew missing gasket material in starboard cargo door.
Stability › Watertight Integrity › General
Issued 8 February 2007
Resolved
Reinstall watertight door closing hardware for hatch located in the male crew locker room.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 February 2007
Resolved
Reinstall galley door that had been removed IAW approved plans.
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 8 February 2007
Resolved
Remove shower and lockers from bow thruster room.
Accommodation/Occupational Safety › Messroom › Size
Issued 8 February 2007
Resolved
Ensure galley and other food preparation areas are maintained in a sanitary condition.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 8 February 2007
Resolved
Ensure penetrations in class A fire control boundaries are insulated IAW 46CFR116.415(2)(ii).
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 8 February 2007
Resolved
Replace missing insulation in overhead of enginroom.
Lifesaving › Buoyant Apparatus › Not on Board
Issued 16 May 2006
Resolved
This vessel is restricted to carrying 710 passengers and 808 total persons during the cold water period of 01 Oct - 14 Jun due to only having 3 inflatable IBA's on board, not meeting the full capacity of lifesaving equipment in 46 CFR 117.206.
Lifesaving › Buoyant Apparatus › Not on Board
Issued 14 April 2006
Resolved
This vessel is restricted to carry 502 passengers and 600 total persons during cold water period of 01 Oct - 14 June due to only having 3 inflatable buoyant apparatus (IBA's) on board, not meeting the full capacity of lifesaving equipment in 46 CFR 117.206.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 7 April 2006
Resolved
This vessel is restricted to carry 301 passengers and 399 total persons during cold water period of 01 Oct-14 June due to not meeting the lifesaving equipment requirements for small passenger vessels in accordance with 46 CFR 117.206.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 March 2006
Resolved
The visual bilge high level alarms are working but the audible alarm is not functioning. Properly repair audible alarm no later than 06 April 06.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 30 March 2006
Resolved
Properly repair and replace missing structural fire protection insulation in bow thruster room, bow thruster room exhaust, around watertight door #18, in overhead of compressor cage, in overhead by sewage pumps in accordance with 46 CFR 116.415.
Lifesaving › Lifebuoys › Serviceable
Issued 30 March 2006
Resolved
Properly replace cracked ring lifebuoy on bow second deck in accordance with 46 CFR 117.70.
Accommodation/Occupational Safety › Messroom › Location
Issued 30 March 2006
Resolved
Found galley preparation area unsanitary, properly clean and make galley preparation are sanitary in accordance with 115.818.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 30 March 2006
Resolved
Properly label both escape hatches on main deck.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 30 March 2006
Resolved
Remove or provide flammable locker for aerosol cans located in engine room.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 30 March 2006
Resolved
Properly adjust fire screen doors located; second deck stbd forward, main deck, and up stairwell door, in accordance with 46 CFR 116.435.
Electrical › Electric Generation Source (service) › Switch
Issued 30 March 2006
Resolved
Label motor controller port side of the galley forward.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 March 2006
Resolved
33U.S.C.1321(j)(D)(ii)-The NTVRP does not discuss the qualified individual's responsibilities for immediate communication with the NRC and notification of the oil spill removal organization.
Stability › Incline Test › General
Issued 20 January 2006
Resolved
Conduct a deadweight survey or inclining experiment of the vessel which is required by the Marine Safety Centers letter dated 24 March 2005.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 20 January 2006
Resolved
Ground detection reveled a one amp ground on Gen #2 and the middle bulb was out on Gen # 1. Remove grounds on the ground detection for Generator # 1 and # 2 in accordance with 46 CFR 120.318.
Electrical › Electric Generation Source (service) › Generator
Issued 20 January 2006
Resolved
Vessel has installed two new generators. Submit plans to Marine Safety Center for new generator installation and load analysis for review in accordance with 46 CFR 116.202.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 7 July 2005
Resolved
Replace all waste recepticles with fire resistant containers IAW 46 CFR 116.405(i)
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 7 July 2005
Resolved
Renew SFP Insullation at Frame 20, aft bulkhead, thruster space.
Fire Fighting › Fire Hoses › Material
Issued 7 July 2005
Resolved
Repalce all non U:-19 Fire Hoses and replace IAW 46 CFR 118.320(b)(1)
Fire Fighting › Structural - Main Vertical Zones › General
Issued 7 July 2005
Resolved
Ensure all FSD properly latch when remotley operated.
Fire Fighting › Fire Hydrants › Number
Issued 7 July 2005
Resolved
Properly label all fire stations.
Stability › Watertight Integrity › General
Issued 7 July 2005
Resolved
Replace gasket on stbd side loading door.
Stability › Watertight Integrity › General
Issued 7 July 2005
Resolved
Renew all rotted WTD gaskets.
Stability › Watertight Integrity › General
Issued 7 July 2005
Resolved
Both Class 3 WTDs needs to be serviced by an authorized Walz and Frenzel Service Tech. Unitl complete both WTD shall remain closed when u/w.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 7 July 2005
Resolved
Eng room vent closure inop, prove proper operation.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 July 2005
Resolved
Repair opr replace lights in steering gear space.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 July 2005
Resolved
Properly label all motor controllers, circuit breakers, and circuit breaker boxes.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 July 2005
Resolved
Cover light swithches and junction box in bar, main deck aft.
Communications › Visual Communication › Warning Sign (gangway)
Issued 7 July 2005
Resolved
Mount Emergency instructions IAW 46 CFR 122.510
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 7 July 2005
Resolved
Replace all life jacket donning placards with placard reflecting style of lifejacket onboard.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 7 July 2005
Resolved
Label lifejacket locker below benches on the saphire deck.
Electrical › Electrical Distribution System (service)
Issued 14 April 2004
Resolved
8 AMPS TO GROUND ON MAIN BUS. TRACE GROUND AND PROVE PROPER OPERATION OF METER. LEGACY COMPONENT DESC: Ground Detection
Engineering › Bilge Water Management System
Issued 14 April 2004
Resolved
PROVE PROPER OPERATION OF BILGE AUDIBLE ALARM AT OPERATING STATION. LEGACY COMPONENT DESC: Interface Detector
Operations/Management › Navigation Safety
Issued 14 April 2004
Resolved
REPLACE RULES TO THE ROAD WITH UPDATED VERSION D LEGACY COMPONENT DESC: Carriage of Charts and Publications
Fire Fighting › Combustible Materials
Issued 10 March 2004
Resolved
Submit to the OCMI for approval a list of Modifications made to the vessel, including manufacture data, and wieghts added and removed. LEGACY COMPONENT DESC: Primary Deck Coverings
Engineering › Bilge Water Management System
Issued 28 January 2003
Resolved
INDICATOR LIGHTS AT BRIDGE STOPPED WORKING AFTER NEW REMOTE ALARM SYSTEM WAS INSTALLED. LEGACY COMPONENT DESC: Interface Detector
Engineering › Freshwater System (cylinder head cooling)
Issued 28 January 2003
Resolved
PROVIDE VALVE HANDLE ON RAW WATER H2O INTAKE FOR STBD MAIN LEGACY COMPONENT DESC: Valve
Engineering › Bilge Water Management System
Issued 28 January 2003
Resolved
RE-LABEL ENGINE ROOM BILGE SUCTION LEGACY COMPONENT DESC: Piping
Fire Fighting › Fire Pumps
Issued 28 January 2003
Resolved
REPLACE FIRE PUMP PRESSURE GAUGE LEGACY COMPONENT DESC: Pressure
Engineering › Compressed Air System (start air)
Issued 28 January 2003
Resolved
PROVIDE RELIEF VALVE INSTALLATIONS FOR BOTH SS AIR COMPRESSOR DISCHARGE BEFORE AIR RECEIVER ISOLATION VALVE. LEGACY COMPONENT DESC: Valve
Electrical › Electrical Distribution System (service)
Issued 28 January 2003
Resolved
PROVIDE EXPLANATION FOR BLUE TAPE IN ELECTRICAL PANEL IN CHILLER COMPARTMENT LEGACY COMPONENT DESC: Distribution Panel Bus
Stability › Watertight Integrity
Issued 28 January 2003
Resolved
VERIFY AFT WTD FUNCTION IAW MANUFACTURES SPECIFICATIONS LEGACY COMPONENT DESC: Watertight Door
Engineering › Thrusters › Motor
Issued 26 November 2002
Resolved
Oil in bilge under thruster motor/engine.
Engineering › Bilge Water Management System › Strainer
Issued 26 November 2002
Resolved
Suction strainer for bilge suction under crew lounge clogged. Clean strainer.
Fire Fighting › Ventilation Systems
Issued 27 February 2002
Resolved
PROVIDE MEANS TO REMOTELY CLOSE PORT SIDE ENGINE ROOM VENT DAMPER. LEGACY COMPONENT DESC: Duct Hatches
Engineering
Issued 27 February 2002
Resolved
REPAIR ALL AUDIBLE ALARMS ON BRIDGE AND STARBOARD ENGINE VISUAL ALARMS.
Construction/Loadline
Issued 26 March 2001
Resolved
Conduct temporary repairs in accordance with approved proposal submitted toOCMI, in way of holed side plating around port side exhaust ports in lazar-ette, to the satisfaction of attending marine inspector and cognizant OCMI.
Engineering
Issued 26 March 2001
Resolved
Reinstall and prove proper operation of both MDE and both SSG raw water ex-hust cooling systems, to the satisfaction of the attending marine inspectorand the cognizant OCMI.
Construction/Loadline
Issued 26 March 2001
Resolved
Provide set of hull gaugings in way of holed side plating around port side exhaust ports in lazerette and proposal for temporary repairs of the same, prior to the loading of passengers and to the satisfaction of the attendingmarine inspector and the cognizant OCMI.
Construction/Loadline
Issued 2 February 2001
Resolved
CALIBRATE OR REPLACE PRESSURE GAUGE ON BILGE PUMP.
Lifesaving
Issued 2 February 2001
Resolved
REPLACE ESCAPE HANDLE, LIGHTING GLOBE & THERMOMETER COVER IN REFER.
Engineering
Issued 2 February 2001
Resolved
INSTALL LAGGING ON PORT MDE TURBO.
Construction/Loadline
Issued 30 April 2000
Resolved
Provide proposal & make permanent repairs to aft port corner in way of the main deck - deck knuckle & aft bulwark/railing system. Vessel restricted to the inside harbor breakwall until permanent repairs are affected and to the satisfaction of the attending marine inspector and the cognizant OCMI.
Construction/Loadline
Issued 30 April 2000
Resolved
Prior to the carriage of passengers, propose and make temporary repairs to the aft port corner in way of the main deck - deck knuckle. Vessel is re- stricted to the inside harbor breakwall until permanent repairs are affect-ed and completed to the satisfaction of the attending marine inspector.
Unknown
Issued 28 January 2000
Resolved
Properly mark upper deck passenger capacity.
Fire Fighting
Issued 28 January 2000
Resolved
Correct fire plan to requirements of 46 CFR 116.530. Post in positions "accessible and visible" to passengers.
Engineering
Issued 28 January 2000
Resolved
Perform MDE and SSGEN control tests in presence of Marine Inspector.
Engineering
Issued 28 January 2000
Resolved
Replace missing exhaust lagging on both SSGENs and bow thruster.
Electrical
Issued 28 January 2000
Resolved
Prove proper operation of engine room emergency light over entrance door.
Electrical
Issued 28 January 2000
Resolved
Clean dust from space heaters in DC locker and lower galley.
Accommodation/Occupational Safety
Issued 28 January 2000
Resolved
Clean hydraulic locker of oil and debris.
Electrical
Issued 28 January 2000
Resolved
Replace missing switch cover for aft "Sapphire" bus station flourescent light switch cover.
Accommodation/Occupational Safety
Issued 28 January 2000
Resolved
Clean all bus stations and galley areas. Remove and dispose of perishable food left uncovered.
Construction/Loadline
Issued 28 January 2000
Resolved
Replace gasket for stbd cargo door.
Documentation
Issued 28 January 2000
Resolved
Correspond with MSC to get stability letter corrected to include ALL w/t doors (one is not addressed in letter).
Lifesaving
Issued 29 March 1999
Resolved
Install proper type and size retro-reflective tape to all life rings to satisfaction of attending marine inspector.
Fire Fighting
Issued 29 March 1999
Resolved
Provide location signs for fire stations #2, 4, and main deck galley to thesatisfaction of attending marine inspector.
Documentation
Issued 29 March 1999
Resolved
Prior to carrying passengers, provide proof of valid Certificate of Documentation to satisfaction of attending Marine Inspector.
Engineering
Issued 29 March 1999
Resolved
Prove operation of low lube oil alarm and shutdown for both main diesel engines to satisfaction of marine inspector.
Engineering
Issued 29 March 1999
Resolved
Prove operation of high jacket water alarms on both main diesel engines andboth ship's service generators to satisfaction of attending marine inspector.
Unknown
Issued 23 March 1998
Resolved
REPAINT DRAFT MARKS.
Electrical
Issued 23 March 1998
Resolved
INSTALL MISSING FLAME IMPINGEMENT BULB.
Electrical
Issued 23 March 1998
Resolved
REMOVE STANDING WATER FROM BATTERY BOX IN PILOT HOUSE.
Accommodation/Occupational Safety
Issued 23 March 1998
Resolved
REMOVE PAINT FROM GASKET ON EMERGENCY ESCAPE HATCH IN ENGINE ROOM.
Electrical
Issued 23 March 1998
Resolved
INSTALL A BLANK IN OPEN CIRCUIT BREAKER PANELS IN THE GALLEY, ALL BARS AND PASSENGER SPACES.
Documentation
Issued 23 March 1998
Resolved
VESSEL IS RESTRICTED TO OPERATION NOT MORE THAN 1000 FT. FROM SHORE UNTIL GREAT LAKES RADIO CERTIFICATE IS RENEWED.
Lifesaving
Issued 23 March 1998
Resolved
PROVE PROPER OPERATION OF BILGE ALARMS.
Lifesaving
Issued 23 March 1998
Resolved
REPLACE MISSING CAP ON LUBE OIL FILL PIPE.
Engineering
Issued 28 January 1997
Resolved
Overspeed and emergency shutdown tests of ships service generator not tetsted per operators request. defered till 28 MAR 97_x001C_ _x001C_ _x001C_
Lifesaving
Issued 28 January 1997
Resolved
Man overboard drills to be conducted when weather allows. NLT 28MAR97
Fire Fighting
Issued 2 February 1996
Resolved
Conduct pressure testing of all firehoses in the presence of a Coast Guard inspector.
Fire Fighting
Issued 2 February 1996
Resolved
Conduct operational test of firemain system. Operate bilge and sprinkler system to satisfaction of Marine Inspector.
Lifesaving
Issued 2 February 1996
Resolved
Provide bracket for safe stowage of helium cylinder presently located in coat room on Saphire deck.
Construction/Loadline
Issued 2 February 1996
Resolved
Prove satisfactory operation of Class III sliding watertight door panel on bridge.
Lifesaving
Issued 2 February 1996
Resolved
Conduct abandon ship, man-overboard, fire and flooding drills prior to underway operation of vessel.
Lifesaving
Issued 7 February 1995
Resolved
Perform drills consisting of fire, man overboard, abandon ship, flooding and anchoring to the satisfaction of attending marine inspector.
Accommodation/Occupational Safety
Issued 7 February 1995
Resolved
Securely anchor galley deep fat fryer.
Construction/Loadline
Issued 7 February 1995
Resolved
Clean knife edges, adjust dogs, grease dogs, and clean/repair gaskets on all quick acting watertight doors.
Engineering
Issued 7 February 1995
Resolved
Repair exhaust leak on #1 ship service generator in way of turbo-charger outlet.
Fire Fighting
Issued 7 February 1995
Resolved
Demonstrate operation of CO2 system pulls, sirens, pressure switch and timedelays.
Construction/Loadline
Issued 7 February 1995
Resolved
Demonstrate proper operation of FWD hydraulic watertight door handpump (failed to close door).
Fire Fighting
Issued 7 February 1995
Resolved
Conduct satisfactory hydrostatic test of fire hoses in presence of inspector.
Construction/Loadline
Issued 7 February 1995
Resolved
Repair bolt holes drilled through bow thruster room quick acting watertightdoor.
Lifesaving
Issued 7 February 1995
Resolved
Adjust door alarm switch for watertight door between chiller space and crews locker.
Lifesaving
Issued 7 February 1995
Resolved
Provide names or numbers on all watertight doors to match bridge (indicatorpanel).
Fire Fighting
Issued 7 February 1994
Resolved
Demonstrate required drills: Fire and Man Overboard.
Electrical
Issued 7 February 1994
Resolved
Properly fasten overhead wire and pipeing runs with metalic devices.
Construction/Loadline
Issued 7 February 1994
Resolved
Provide gasketed insulated escape scuttles compatible with surrounding structural fire boundary.
Electrical
Issued 7 February 1994
Resolved
Block batteries in boxes to prevent movement.
Electrical
Issued 7 February 1994
Resolved
Properly secure fathometer wire in #2 void.
Engineering
Issued 7 February 1994
Resolved
Replace missig bolts on both S/S Gen. connection covers.
Fire Fighting
Issued 7 February 1994
Resolved
Renew fire and bilge pump gages with appropriate sized glass.
Construction/Loadline
Issued 7 February 1994
Resolved
Provide repairs as neccessary to ensure remote operating station for #2 Class 3 WTD cannot be used to open door.
Construction/Loadline
Issued 7 February 1994
Resolved
Prove satisfactory operation of bridge Class 3 WTD indicator lights.
Fire Fighting
Issued 7 February 1994
Resolved
Demonstrate satisfasctory test of all fire pumps and hydro test of all firehoses.
Lifesaving
Issued 7 April 1993
Resolved
VESSEL IS RESTRICTED TO A ROUTE NOT MORE THAN 20 MILES FROM A HARBOR OF_x001C_ SAFE REFUGE DURING TRANSIT.
Documentation
Issued 7 April 1993
Resolved
PROVIDE TO THE COGNIZANT COAST GUARD OFFICE A COPY OF THE COAST GUARD STABILITY LETTER UPON RECEIPT FROM THE COAST GUARD MARINE SAFERTY CENTER.
Documentation
Issued 7 April 1993
Resolved
PRESENT VESSEL FOR FCC SURVEY/EXAMINATION PURSUANT TO ISSUANCE OF_x001C_ RADIOTELEPHONY SAFETY CERTIFICATE.
Casualty record · 8
23 January 2007Routine · role: Acknowledged Pollution Source · activity 2864687
10 May 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 2946267
12 May 2007Routine · role: Involved in a Marine Casualty · activity 2947507
20 July 2007Routine · role: Involved in a Marine Casualty · activity 3035343
11 August 2007Routine · role: Involved in a Marine Casualty · activity 3050936
14 August 2007Routine · role: Involved in a Marine Casualty · activity 3109855
13 April 2013Routine · role: Involved in a Marine Casualty · activity 4798630
15 December 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6874603
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
ODYSSEY II (2007–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.