MAURY USCG vessel records Sign in
← All vessels

FALCON TRADER

FALCON TRADER is a 1993 freight ship. The Coast Guard has recorded 27 inspections since 1993, most recently in June 2014, along with 12 deficiencies and 4 operational controls.

Records from 1993 to 2014. Most recent: inspection, 28 June 2014.

Built
1993
Last inspected
28 June 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9047001 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
386182
Flag
LIBERIA
—
Maury page id
psix-386182

Inspections, by type

…with no type recorded20
Years with a record 14 calendar years (1993–2014)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it15884 - Regulatory (Subpart C or D), Gross Ton
8922 - Regulatory (Subpart C or D), Net Ton
32206 - Displacement, Ton
26446 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

28 June 2014 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4898072
17 March 2014 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4817287
13 December 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4207538
24 February 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3951680
10 May 2009 Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3472169
5 May 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3195858
5 May 2008 ISPS I Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3201155
5 May 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3201230
6 December 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3110369
3 December 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3104718
8 June 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2253075
10 May 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2063827
19 March 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 288195
25 January 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 286231
6 June 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 278639
27 January 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 273840
21 October 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 421821
30 July 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 406286
29 June 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 392644
11 March 1996 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 388963
22 January 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 387009
27 November 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 385190
7 March 1995 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 376138
24 January 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 374481
23 June 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 367945
18 January 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 363855
11 March 1993 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 356921

Deficiency record · 12

Fire Fighting › Fixed Fire Detection System › Alarms
Issued 13 December 2011 Resolved
Any required fixed fire detection and fire alarm system shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. The fire alarm system is inoperable and gives false alarms. SOLAS 1997 Cons. II-2/12.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2011
Resolution: Received a classification society surveyor’s report attesting to the repairs.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 13 December 2011 Resolved
The ship shall be maintained in the condition of the last survey, so as to ensure that the ship remains fit to proceed to sea without danger to the vessel or persons onboard. The #3 ships service diesel generator is leaking oil from the mechanical seal and from the #'s 1 and 4 cylinders; all three ships service generators are leaking oil from the shaft, between the diesel engine and the generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2011
Resolution: Received a classification society surveyor’s report attesting to the repairs.
Fire Fighting › Portable Foam Applicators › General
Issued 13 December 2011 Resolved
All fire extinguishing appliances shall be readily available for use. There are multiple fire extinguishers with dry rotted/cracked hoses, and the portable foam applicator hose is cracked through. SOLAS 1997 Cons. II-2/2.2.7; ISM Code 10.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2011
Resolution: Received a classification society surveyor’s report attesting to the repairs.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 13 December 2011 Resolved
Fire fighting protective clothing shall be constructed of material to protect the skin from heat radiation and burns. One of the ships fire suits has sections of damaged reflective material and is ripped at the seams under the arms. FSS Code 3/2.1.1.1; ISM Code 10.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2011
Resolution: Received a classification society surveyor’s report attesting to the repairs.
Lifesaving › Launching Appliances › Lines
Issued 10 May 2004 Resolved
LIMIT SWITCH INOPERABLE ON STARBOARD SIDE LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 December 2007
Resolution: Rcvd report from TECHO FIBRE clearing deficiency.
Fire Fighting
Issued 25 January 2001 Resolved
Make all Fire Doors in stair tower self-closing. SOLAS 74 amd II-2/37. Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 25 January 2001
Resolved 25 January 2001
Documentation
Issued 25 January 2001 Resolved
Provide updated Oil Transfer Procedures to include all required elements. 33 CFR 155.750. Correct prior to any internal or external transfers.
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Lifesaving
Issued 25 January 2001 Resolved
Renew Stbd lifeboat brake cable for lifeboat manual release where parted. SOLAS 74 amd III/19. Correct prior to departure.
Condition: Unknown
Due 29 January 2001
Resolved 29 January 2001
Navigation
Issued 25 January 2001 Resolved
Make Echo Depth Sounder operable. SOLAS 74 amd V/12(k). Correct prior to departure.
Condition: Unknown
Due 29 January 2001
Resolved 29 January 2001
Documentation
Issued 11 March 1996 Resolved
OIL TRANSFER PROCEDURE NOT IN CORRECT ORDER.
Condition: Unknown
Due 1 July 1996
Resolved 1 July 1996
Lifesaving
Issued 27 November 1995 Resolved
Replace expired medical supplies and provide instructions/descriptions in alanguage understood by the crew.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995
Fire Fighting
Issued 27 November 1995 Resolved
Remove tie back devices from fire doors to engine room and emergency fire pump/steering compartment. Re-install automatic closure devices as necessary.
Condition: Unknown
Due 27 November 1995
Resolved 27 November 1995

Ownership record