MAURY USCG vessel records
← All vessels

LIBERTY

LIBERTY is a 1993 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in September 2025, along with 47 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2016.

Records from 2016 to 2025. Most recent: inspection, 9 September 2025.

Built
1993
Last inspected
9 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDK9119
386203
Flag
UNITED STATES
Maury page id
psix-386203

Inspections, by type

…with no type recorded1
…past their stated due date1
Years with a record 10 calendar years (2016–2025)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)70.0 ft × 24.0 ft × 4.0 ft
Registered tonnagegross 56 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCARANO BOAT BUILDING INC · ALBANY, NY, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portALEXANDRIA BAY, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Simplified, Gross Ton
45 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 20

9 September 2025 Annual Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8230907
17 June 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7934846
20 July 2023 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7740384
21 June 2023 Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7720079
22 May 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7694206
7 June 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7466046
19 May 2022 Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7473609
27 October 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7341416
29 June 2021 DAPI Audit
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7239025
3 June 2021 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7199316
3 June 2021 Drydock Extension
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7221315
21 July 2020 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7008005
18 June 2019 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6716336
1 November 2018 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6572781
20 September 2018 Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6574921
24 July 2018 COI Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6472687
25 July 2017 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6219952
17 July 2016 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5955005
17 July 2016 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5955629
1 June 2016 Hull Examination · Annual Inspection · DAPI Audit · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5894437

Deficiency record · 47

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 September 2025 Resolved
Remote fuel oil valve on the stbd side did not close all the way when operated. F/o shutoff valves installed so as to close against the fuel flow, must be fitted in the fuel supply lines. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2025
Resolved 10 September 2025
Resolution: Vessel rep adjusted the remote cable and the stb remote f/o valve closes completely.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 September 2025 Resolved
Bilge high water level alarms were found not working in any compartment. A visual and audible alarm must be provided at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2025
Resolved 9 September 2025
Resolution: Vessel rep took apart alarm control panel in the pilot house and tightened wire connections. All bilge high water alarms are operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2025 No resolution recorded
Life buoys near the pilot house were found to have dry rotted grab lines. Grab lines were starting to deteriorate with broken strands.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Dirty, parasites
Issued 9 September 2025 Resolved
Found the galley area floor dirty with debris and food. Spaces shall be kept in sanitary conditions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2025
Resolved 12 November 2025
Resolution: Cleaned
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 July 2023 Resolved
(b) Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. The point and uniform loads do not need to be applied simultaneously. Starboard aft entry gate is not closing and securing properly. Gate must be able to open and close appropriately.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 14 August 2023
Resolution: Crew modified gate closure to properly close.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 July 2023 Resolved
(a) At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: (1) Inspection of each portable fire extinguisher, semiportable fire extinguisher, and fixed gas fire extinguishing system to check for excessive corrosion and general condition. Engine room fixed firefighting system is past due for servicing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 10 August 2023
Resolution: Vessel rep had third party fire inspection service inspect fix extinguishing system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2023 Resolved
(a) At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Port MDE starting battery has excessive build up of corrosion on terminals. Clean battery terminals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 14 August 2023
Resolution: Battery terminals were cleaned
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 July 2023 Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List Vessel currently has out dated publications onboard. Order or print new Coast Pilot [name withheld], and Navigation Rules of the Road publications.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2023
Resolved 14 August 2023
Resolution: Operator printed and placed required navigation publications onboard
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2023 Resolved
(b) The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: (1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 Provide proof of maintaining monthly inspections of portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 August 2023
Resolution: fire extinguishers were found to have monthly inspections
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 July 2023 Resolved
(f) The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Life jacket stowage boxes shall be labeled appropriately with how many life jackets are located inside of box.
Action required: 10 - Deficiency Rectified
Resolved 20 July 2023
Resolution: Crew placed appropriate labels on each box. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 20 July 2023 Resolved
(b) At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Bilges were discovered to have debris, oily rags, and tools. Crew cleaned all bilges.
Action required: 10 - Deficiency Rectified
Resolved 20 July 2023
Resolution: Bilges were cleaned before MI departure.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 7 June 2022 Resolved
Cooler vent in bar space full of dust. Clean cooler vent to provide required air flow to the machinery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Received email with picture correcting deficiency
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 June 2022 Resolved
Through deck penetration for on/off switch in galley area is required to be watertight. Bow thruster cable through bulkhead penetration is required to be watertight. Port aft engine room bulkhead penetration is not watertight. make penetration watertight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022 Resolved
On/off switch in galley area not labeled. Label switch for intended service.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 June 2022 Resolved
Painted water hose on stbd main engine (outboard side of engine) appears to be dry-rotted. Replace with new hose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 June 2022 Resolved
Fire pump raw water strainer found leaking. Repair leak.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022 Resolved
Generator battery box missing cover. Install cover for battery.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022 Resolved
Generator #2 fuel nozzle fitting weeping. Ensure fitting is tight and does not leak.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 June 2022 Resolved
Various raw water hoses did not have double hose clamps. Ensure all raw water hoses are double clamped.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2022 Resolved
Port main engine battery found with corrosion covering the terminal. Clean terminal and ensure corrosion is mitigated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 June 2022 Resolved
Port main engine fuel hose to lift pump is dry rotted. Renew hose with same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 June 2022 Resolved
Install guard to front of generator to protect personnel from rotating machinery.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 June 2022 Resolved
Found oil soaked sorbent in the engine room. Ensure oil soaked sorbent rags are removed from engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 7 June 2022 Resolved
FCC Great Lakes 13 month radio inspection not present on board vessel at time of inspection. Place Great Lakes radio inspection report on board vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 16 September 2022
Resolution: MI verified deficiency correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 August 2020 Resolved
Lifejacket placards were not posted in conspicuous places and accessible and visible to passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2020
Resolved 17 September 2020
Resolution: Vessel rep installed life jacket donning placards.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 August 2020 Resolved
Batteries in engine room found not to have covers and boxes broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2020
Resolved 17 September 2020
Resolution: New battery box was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 18 August 2020 Resolved
Debris, tools, and equipment found throughout the bilge areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2020
Resolved 17 September 2020
Resolution: Bilges were found to be cleaned and bebris free.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 June 2019 Resolved
Found dry-rotted fresh water cooling hose. Replace fresh water cooling hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Cooling water hose has been replaced with new hose.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 June 2019 Resolved
FCC station license was expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 June 2019
Resolved 25 June 2019
Resolution: Owner obtained new FCC Station License. New call sign.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 July 2018 Resolved
Pre-engineered fixed fire extinguishing system was not tested by 3rd party prior to inspection. Vessel rep to research testing procedures and test in the presence of the MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 20 September 2018
Resolution: Tested pre-engineered fixed fire extinguishing system iaw manufacturers instructions. Test was satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 July 2018 Resolved
Vessel name not visable on bow of vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 1 August 2018
Resolution: Vsl rep installed vessels name on the port and stbd bow of the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 July 2018 Resolved
Updated Coast Pilot not on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 1 August 2018
Resolution: Vsl rep placed updated coast pilot on board.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 July 2018 Resolved
Updated Light List not on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 1 August 2018
Resolution: Vsl rep placed updated light list on board.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 July 2018 Resolved
Updated charts of the area of operation not on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 1 August 2018
Resolution: Vsl rep placed new charts on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 July 2018 Resolved
Lifejacket donning placards were not posted in all lifejacket storage areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 1 August 2018
Resolution: Vsl rep installed life jacket donning placards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2018 Resolved
Float light bracket was not installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2018
Resolved 9 August 2018
Resolution: Float light bracket installed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 25 July 2017 Resolved
Exhaust piping in the lazarette is not supported by hangers or supports. Pipe is approximately 10ft long and has a sag in the middle of the pipe. Vessel will install piping supports during the winter lay-up.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 20 September 2018
Resolution: Vessel rep installed pipe hangers for the exhaust pipe for support.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 25 July 2017 Resolved
Life jacket storage on the stbd side second deck is not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 21 August 2017
Resolution: Lifejacket storage has been properly marked.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 July 2017 Resolved
Water light did not work and the light seperated from the body. Vessel restriced to daylight operations until water light has been corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 21 August 2017
Resolution: Vessel rep purchased new waterlight and installed.
Lifesaving › Lifebuoys › Serviceable
Issued 25 July 2017 Resolved
Two life buoys were found with missing plugs and life lines wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 21 August 2017
Resolution: Lifebuoys have been replaced.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 25 July 2017 Resolved
Broken windows on main deck, stbd side head window and stbd side stern window.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 21 August 2017
Resolution: Local glass company removed broken glass and installed new glass.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 July 2017 Resolved
Port navigation light was not working. Found bad bulb. Vessel rep replaced bulb.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 25 July 2017
Resolution: Vessel rep replace port navigation light bulb.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 17 July 2016 Resolved
Make permanent repairs to port marine gear.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2016
Resolved 27 July 2016
Resolution: Both marine gears renewed in kind.
Construction/Loadline › Hull › Hull Plating
Issued 1 June 2016 Resolved
Clean and weld pits (as marked) on port and starboard hulls.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 7 June 2016
Resolution: Pits ground to sound metal and welded. Bottom coating applied after inspection of repair
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 1 June 2016 Resolved
Install 30/30 mesh flame screen on fuel oil tank vents.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 7 June 2016
Resolution: flame screen installed on fuel tank vents.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 June 2016 Resolved
Remove deadend wires located on the port side of the steering room compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 7 June 2016
Resolution: Wires removed from vessel.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 1 June 2016 Resolved
Install new stern tube cutless bearings at the through hull point.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 7 June 2016
Resolution: Bearings, shafts and propellers renewed.

Casualty record · 1

17 July 2016Routine · role: Involved in a Marine Investigation (non-casualty) · activity 5955629
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record