MAURY USCG vessel records Sign in
← All vessels

WM. MARKET

WM. MARKET is a 1993 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1993, most recently in April 2026, along with 41 deficiencies.

Records from 1993 to 2026. Most recent: inspection, 27 April 2026.

Built
1993
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBR2330
386268
Flag
UNITED STATES
—
Maury page id
psix-386268

Inspections, by type

…with no type recorded1
Years with a record 28 calendar years (1993–2026)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)95.5 ft × 38.0 ft × 8.8 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)95.5 ft × 38.0 ft × 8.8 ft
ITC tonnageNot recorded
BuilderPETERSON BUILDERS, INC. · STURGEON BAY WI, UNITED STATES · built 1993
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPUT-IN-BAY, OH
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 54

27 April 2026 Annual Inspection · MTSA Verification · Vessel Attendance · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8356379
5 December 2025 Examination of Repairs · Deadweight Survey · Internal Structural Exam · Hull Examination · Vessel Attendance
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8278084
17 November 2025 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8269832
22 July 2025 Plan Review (Other than "T")
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8191723
27 August 2024 In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7990510
1 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7905382
29 November 2023 In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7836708
26 April 2023 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7676085
21 April 2022 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7435203
31 August 2021 In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7302117
8 May 2021 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7192121
27 April 2021 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7185428
29 October 2020 Examination of Repairs · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7086595
7 July 2020 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6999640
25 April 2019 MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6670827
10 May 2018 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6411184
24 March 2017 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6108705
1 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6050794
2 November 2016 MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6033785
18 October 2016 In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6029380
7 June 2016 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5906201
3 February 2016 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5808866
29 April 2009 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3453938
21 May 2008 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3212717
15 April 2008 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3168157
30 May 2007 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2946035
16 May 2007 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2932161
11 April 2007 MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2905701
24 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2657771
19 April 2006 Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2628400
1 October 2005 Hull Examination
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2541709
18 May 2005 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2361281
20 April 2005 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2339054
26 July 2004 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2145939
27 April 2004 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2053577
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1969267
16 April 2003 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1774861
10 March 2003 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1755112
17 April 2002 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1605551
3 May 2001 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1459700
1 June 2000 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 128290
12 May 2000 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1361742
20 April 2000 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1448102
21 April 1999 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1124345
6 May 1998 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 791275
23 April 1997 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 790089
22 April 1996 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1079888
30 May 1995 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 874278
5 May 1995 Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1374276
21 April 1995 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1412785
2 May 1994 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1171889
21 April 1994 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1398049
30 April 1993 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 837841
23 April 1993 Initial Certification · Hull Examination
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 840315

Deficiency record · 41

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 April 2026 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board an FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's EPIRB battery was found to be out of date. Vessel cannot operate beyond 3 miles from coastline of Great Lakes. 46 CFR 117.64
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 May 2026
Resolution: New hydro and battery
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. On the bridge of the vessel, there are multiple power strips “daisy chained” together, creating an electrical hazard. 46 CFR 120.200(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 21 May 2026
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 May 2021 Resolved
Based on gauging report and reported cooler leak, vessel is to submit repair plan for review to local [name withheld] repair plan is reviewed, a CG MI will attend to verify repair plan is adequate and to ascertain any additional gauging requirements. Please note after CG MI review of repair plan and further on-site inspection the CG may require the vessel to proceed to dry-dock for permanent repairs if temporary repairs are determined to be inadequate or extensive. 46CFR176.20-1(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2021
Resolution: MI attended vessel and are requiring permanent repairs based on unsatisfactory hull condition. New 835v issued.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 May 2021 Resolved
Based on damage survey conducted, gauging report from CCSR, and active main engine cooling leak, vessel is to make permanent repairs to bottom plate in way of MDE/Gen keel coolers from frame 40-60 port and stbd sides. Crop and renew bottom plate and cooler channels port side approx 20ft by 8ft (entire length of space) and STBD side 10x6 ft in aft section and 18x18 insert fwd toward centerline. Crop and renew wasted bilge piping/foot/strainer in same location. Dimensions are approximate and will be determined by bottom inspection and condition of hull while cropping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2021
Resolution: Satisfactory repairs to bottom plates completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 27 April 2021 Resolved
Area surrounding the Sewage tank (19' in length and 5' in width) was found to have areas of wastage in the HULL plate. Vessel Owner shall have the area Gauged within 30Days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 14 May 2021
Resolution: MI attended vessel after receipt of gauging report as required above. MI is requiring permanent repairs based on unsatisfactory hull condition. New 835v issued.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 October 2020 Resolved
Multiple deck hatches have gasket material that are faulty (improperly sized, not seated, etc.) and must be reattached and prove that the closure is watertight, prior to departure. Captive chains must be reattached to prevent loss, prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2020
Resolved 23 November 2020
Resolution: After adjusting the dogs on the hatches, all seals were watertight. Deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 October 2020 Resolved
#1 port void has an inset that is approximately 3" deep and 6" x 10" on the forward bulkhead of the compartment where the hull meets the overhead (main deck). Crop & renew hull plating as well as the tripped web frame.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2020
Resolved 11 November 2020
Resolution: Welds were visually inspected and found to be satisfactory. Deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 October 2020 Resolved
In the #2 port void there is an insert that is only welded from the outside. properly seal the insert.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 11 November 2020
Resolution: All welds were visually inspected and found to be satisfactory. Deficiency is cleared.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 October 2020 Resolved
Where the forward ramp connects to the vessel, there are cracks at the base of that point. Properly prepare and weld those cracks, to the satisfaction of the Coast Guard Marine Inspector within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2020
Resolved 11 November 2020
Resolution: The welds were visually inspected and found to be satisfactory. The deficiency is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 July 2020 Resolved
Painters attaching three sets of life floats (3) were deteriorated and in need of replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 16 July 2020
Resolution: Received objective evidence (pictures and painter line specs) that the above has been completed.
Communications › Radio Communications › EPIRB
Issued 7 June 2016 Resolved
The HRU (hydrostatic release unit) for the EPIRB indicated an expired date (10/2015). Replace HRU or re-mark with proper date (2yrs after installation) if intitially marked incorrectly. (46 CFR 185.740).
Due 21 June 2016
Resolved 9 June 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 15 April 2008 Resolved
By next drydock (Oct 2010) renew battery cables from generator batteries and batery charger (welding cable) and renew w/ approved cable.
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 19 April 2011
Lifesaving › Lifefloat › Paddle
Issued 15 April 2008 Resolved
Replace (02) lifefloat paddles by 15 May 2008
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 20 May 2008
Lifesaving › Lifefloat › Serviceable
Issued 15 April 2008 Resolved
Replace two (02) 22 person lifefloats by 15 July 2008.
Action required: 705 - Other - as specified
Due 15 July 2008
Resolved 20 May 2008
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 15 April 2008 Resolved
Make first aid kit in compliance with 46 CFR 160.41 (renew expired items). Not lifeboat equipment.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 20 May 2008
Lifesaving › Buoyant Apparatus › Serviceable
Issued 11 April 2007 Resolved
Replace two (2) BA's due to wear. Passenger count is reduced by 44 until this requirement is completed.
Condition: Improper/Lack of Maintenance
Due 16 May 2007
Resolved 10 May 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 April 2007 Resolved
Change PFD count on storage locket to reflect current number of jackets.
Condition: Unknown
Due 16 May 2007
Resolved 10 May 2007
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 11 April 2007 Resolved
Replace sprinkler head on car deck, port side.
Condition: Damaged By Earlier Event
Due 16 May 2007
Resolved 11 April 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 April 2007 Resolved
Provide proof of servicing for both portable extinguishers and fixed system.
Condition: Unknown
Due 30 April 2007
Resolved 10 May 2007
Engineering › Pressure Vessel › Pressure Gauge
Issued 11 April 2007 Resolved
Replace broken 0 - 200 psi pressure gauge on bottom air receiver.
Condition: Damaged By Earlier Event
Due 16 May 2007
Resolved 10 May 2007
Engineering › Bilge Water Management System › Strainer
Issued 11 April 2007 Resolved
Clean bilge area around strainer basket, aft void.
Condition: Improper/Lack of Maintenance
Due 16 May 2007
Resolved 10 May 2007
Lifesaving › Lifefloat › Serviceable
Issued 19 April 2006 Resolved
Replace starboard outboard life float and repair middle life float grab lines on stern. Passenger count reduced to 456 until repaired.
Due 2 May 2006
Resolved 24 May 2006
Resolution: Vessles rep''s replaced damaged lifefloat, and replaced line, all sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 April 2006 Resolved
Ensure that all the life floats have individual float light attached as per 46 CFR 180.15-1 and 46 CFR 180-15-5.
Due 4 May 2006
Resolved 24 May 2006
Resolution: Vessels rep''s added new lights to each float, tested all the lights with sat results.
Electrical › Electric Generation Source (service) › Neutral Bus
Issued 20 April 2005 Resolved
Install rubber mats at distribution panels in engine room (for generators).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 17 May 2005
Resolution: Millers crew installed a rubber mat at the distrubution panel. (all sat)
Lifesaving › Thermal Protective Aids › General
Issued 20 April 2005 Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 17 May 2005
Resolution: Millers crew relaced all expired items in the 1st aid kit.
Communications › Audible Communications › SPD (Other)
Issued 20 April 2005 Resolved
Repair or replace fwd port public announcement speaker.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 15 July 2005
Engineering › Fuel Oil Service System › Hose
Issued 27 April 2004 Resolved
Replace supply and return fuel lines on both generators
Condition: Improper/Lack of Maintenance
Due 29 May 2004
Resolved 26 July 2004
Engineering › Steering Gear System › Hydraulic Hose
Issued 27 April 2004 Resolved
Replace starboard side outter most steering hydraulic hose.
Condition: Improper/Lack of Maintenance
Due 29 May 2004
Resolved 26 July 2004
Engineering › Bilge Water Management System › Piping
Issued 27 April 2004 Resolved
Replace port forward ballast reach rod cap. LEGACY COMPONENT DESC: Ballast System
Condition: Damaged By Earlier Event
Due 29 May 2004
Resolved 26 July 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 16 April 2003 Resolved
Repair or replace the stbd engine oil pressure gauge at the operating station. LEGACY COMPONENT DESC: Oil Gauge
Condition: Unknown
Due 16 April 2003
Resolved 16 April 2003
Fire Fighting › Automatic Sprinkler System
Issued 17 April 2002 Resolved
01 Car Deck sprinkler head was replaced. LEGACY COMPONENT DESC: Spare Sprinkler Heads
Due 17 April 2002
Resolved 17 April 2002
Operations/Management › Passenger Operations › Safety Orientation
Issued 17 April 2002 Resolved
Passenger safety orientations were not being completed.
Due 17 April 2002
Resolved 17 April 2002
Electrical
Issued 6 May 1998 Resolved
HARDWIRE MSD PUMP AND FLOAT SWITCH
Condition: Unknown
Due 15 May 1998
Resolved 21 May 1998
Lifesaving
Issued 21 April 1995 Resolved
PASSENGER CAPACITY REDUCED BY 36 DUE TO THE REDUCED NUMBER OF LIFE JACKETS WHICH FAILED INSPECTION. PASSENGER CAPACITY IS 464 UNTIL NEW LIFE JACKETS ARE PROCURED.
Condition: Unknown
Due 21 April 1995
Resolved 21 April 1995
Lifesaving
Issued 21 April 1994 Resolved
JACKETS MANUFACTURED ON 25 NOVEMBER 1992. MATERIAL DETERIORATED DUE TO SUNLIGHT. COVERING RIPPED WHEN PULLED. JACKETS HAVE BEEN IN SERVICE SINCE 21APR 93 WHEN VESSEL ENTERED SERVICE. ONLY JACKETS EXPOSED TO SUN LIGHT WEREAFFECTED. Q#160.055/126/0 LOT 1920028 PASSENGERS LIMITED TO 429.
Condition: Unknown
Due 21 May 1994
Resolved 20 July 1994
Lifesaving
Issued 30 April 1993 Resolved
MARK AND PLACE EMERGENCY RELEASE FOR BOUYANT APPARATUS IN VIEW OF PASSENGERS
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Documentation
Issued 23 April 1993 Resolved
Post the original stability letter on board the vessel prior to carrying passengers for hire and not later than the compliance date.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Lifesaving
Issued 23 April 1993 Resolved
Affix the Category 1 EPIRB in a position to permit it to float free as required by 46CFR180.40-1(c) prior to carrying passengers for hire and not later than the compliance date.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Lifesaving
Issued 23 April 1993 Resolved
Mark the vessel's name on the emergency position indicating radiobeacon (EPIRB) as required by 46CFR185.30-30 prior to carrying passengers for hireand not later than the compliance date.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Lifesaving
Issued 23 April 1993 Resolved
Outfit each life float on board the vessel with two paddles, a water light,and a painter as required by 46CFR180.15-1(a) prior to carrying passengers for hire and not later than the compliance date.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Lifesaving
Issued 23 April 1993 Resolved
Conduct drills of the regular crew as required by 46CFR185.25-10 prior to carrying passengers for hire and not later than the compliance date.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993

Ownership record